J.. -

c g

n a

p q m ' ~.:

q

~

40 December 18, 1981 gCM

<DISTRIBUIION:TWambach '

$WL Docket No. 50-10 Docket PO'Connd 9 DECN I

LS05 12-053 f;RC PDR HSmith ('

s LPDR RDiggs wr.

Mr. Byron Lee TERA DELD V

Executive Vice President NSIC Ol&E (5)

,a \\ p Commonwealth Edison Company ORB #5 RF ACRS (10)

Post Office Box 767 HDenton BScharf (10)

Chicago, Illinois 60690 ECase GDeegan (4)

JCarter Xtra Cy (3)

Dear Mr. Lee:

DEisenhut GCwalina Glainas DCrutchfield In accordance with the Nuclear Regulatory Corrmission's Memorandum and Order (CLI-81-25) in the Matter of Commonwealth Edison Company (Dresden Nuclear Power Station Unit 1) Docket No. 50-10, September 28, 1981, I have determined that the activities authorized by Amendment No. 35 to Facility Operating License No. DPR-2 present no significant hazards consideration. Supporting documentation is provided in the enclosed

" Safety Evaluation by the Office of Nuclear Reactor Regulation Supporting Amendment No. 35 to Facility Operating License No. DPR-2, Commonwealth Edison Company, Dresden Unit No.1, Docket No. 50-10",

dated December 18, 1981, and the materials referenced therein.

Accordingly, the Division of Licensing has issued, by a separate transmittal lettcr, Amendment No. 35 to License No. DPR-2.

The amendment authorizes the chemical decontamination of the primary cooling system, revises the Technical Specifications.to permit decon-tamination without requiring containment integrity since there is no fuel in the reactor and the primary cooling system is depressurized.

The amendment also authorizes the exclusion of the radioactive liquid storage tanks in the seismically designed chemical cleaning building from the above grade storage curie limitations.

The amendment does not authorize operation of Unit 1 subsequent to the clemical cleaning. Such authorization will be the subject of a separate licensing action.

A copy of the Federal Register Notice is also enclosed.

Sincerely, p u d to w by 8201200070 811218

" % 3. Der,tJrt PDR ADOCK 05000010 Harold R. Denton, Director P

PDR Office of Nuclear Reactor Regulation

Enclosures:

1.

Safety Evaluation Supporting Amendment No. 35 to DPR-2 2.

Fedcral Register Notice

  • SEE ATTACMCO FOR PREVIOUS CONCURRENCE

,f IT

.DL:0,RB#h, DLj0IlB#5/LA DLj0RBf5/AC DL:AD/SA DL :g,_

fk: ecd [

HDen,f})n ffRR:

omen P0'Connor:rj HSmith TWambach Glainas DEisenhut t

"iEldlii '

"Ii[6/5II "If/fE/5fI "i lE5/5iT 5'1"

\\"

Ijfl5i'

~

g/}i emcmnu.m m mNacu m OFFICI AL R ECO5'D COPY oua om m m

/

/>

@9 EIGeq Y-0, UNITED STATES

')

[,g NUCLEAR REGULATORY COMMISSION 5 :*

' /; C W ASHING TON. D. C. 20555

~

o\\... /

DISTRIBUTION Docket P0'Connor Docket No. 50-10 NRC PDR HSmith (2) 6 LS05 LPDR RDiggs TERA OELD NSIC OI&E (5)

Mr. Byron Lee ORB #5 RF ACRS (10)

Executive Vice President HDenton BScharf (10)

Commonwealth Edison Company ECase GDeegan (4)

Post Office Box 767 JCarter Xtra Cy (3)

Chicago, Illinois 60690 DEisenhut GCwalina Glainas DCrutchfield

Dear Mr. Lee:

TWambach In accordance with the Nuclear Regulatory Comission's Memorandum and Order (CLI-81-25) in the Matter of Commonwealth Edison Company (Dresden Nuclear Power Station Unit 1) Docket No. 50-10, September 28, 1981 I

have determined that the activities authorized by Amendment No.

to Facility Operating License No. DPR-2 present no significant hazards consideration. Supporting documentation is provided in the enclosed

" Safety Evaluation by the Office of Nuclear Reactor Regulation Supporting Amendment No.

to Facility Operating License No. DPR-2, Commonwealth Edison Company, Dresden Unit No.1, Docket No. 50-10",

dated December

, 1981, and the materials referenced therein.

Accordingly, the Division of Licensing has issued, by a separate transmittal letter, Amendment No.

to License No. DPR-2.

The amendme6t authorizes the chemical decontamination of the primary cooling system, revises the Technical Specifications to permit decon-tamination without requiring containment integrity since there is no fuel in the reactor and the primary cooling system is depressurized.

The amendment also authorizes the exclusion of the radioactive liquid storage tanks in the seismically designed chemical cleaning building from the above grade storage curie limitations.

The amendment does not authorize operation of Unit I subse@ ent to the clemical cleaning. Such authorization will be the subject of a separate licensing action.which will be pre-noticed in the Federal Register.

A copy of the Federal Register Notice is also enclosed.

Sincerely, Harold R. Denton, Director

~

Office of Nuclear Reactor Regulation

Enclosures:

1.

Safety Evaluation Supporting Amendment No, to DPR-2 2.

Federal Register Notice

u. ts w
  • SEE ATTACHED FOR PREVIOUS CONCURRENCE DL : 0R.B.'#.5..I..Pl.1 D..L. :.0..RB....#. 5../..L. /

DL.:0RB #5/.AC DL:AD/..SA DL:DIR NRR:D/DIR NRR:DIR omce >

sun M P0,' C,o,r,1n,o r,: rj,H S,m i,,t!3,,,,,,,,,,

,,T,Wa,mb a cl1,,,,,

GCLainas HDenton DEisenhut ECase

.....l.h.L326.1.....ll.d/Bl*.......1.1./.1.2/81*

.11./,2.3 /.g 1 +

.,L,./g1

..L../81

..L,,/.81 om>

me ronu au em nncu ma OFFICIAL RECORD COPY usce mi_um L

.[

UNHrED STATES 6..F y

[ ),

NUCLEAR REGULATORY COMMISSION

'e WASHING TON. D. C. 20555 f

y

%.....y DISTRIBUTI0ft.

Docket RDiggs flRC PDR OELD Docket fio. 50-10 LPDR OI&E (5)

L505 TERA ACRS (10) f1 SIC BScharf (10)

ORB #5 RF GDeegan (4)

Mr. Byron Lee HDenton HSmith (2)

Executive Vice President ECase GCwalina Commonwealth Edison Company JCarter Xtra Cy (3)

Post Office Box 767 DEisenhut Chicago, Illinois 60690 Glainas TWambach

Dear Mr. Lee:

P0'Connor In accordance with the fluclear Regulatory Commission's Memorandum and Order (CLI-81-25) in the M uter of Commonwealth Edison Company (Dresden fluclear Power Station Unit 1) Docket tio. 50-10, September 28, 1981, I have determined that the activities authorized by Amendment flo.

to Facility Operating License flo. DPR-2 present no significant hazards consideration. Supporting documentation is provided in the enclosed

" Safety Evaluation by the Office of fluclear Reactor Regulation Supporting Amendment flo, to Facility Operating License fio. DPR-2, Comonwealth Edison Company, Dresden Unit flo.1, Docket fio. 50-10",

dated December

, 1981, and the materials referenced therein.

Accordingly, the Division of Licensing has issued, by a separate transmittal letter, Amendment flo.

to License flo. DPR-2.

The amendnent authorizes the chemical decontamination of the primary cooling system, revises the Technical Specifications to permit decon-tamination without requiring containment integrity since there is no fuel in the reactor and the primary cooling system is depressurized.

The amendment also authorizes the exclusion of the radioactive liquid storage tanks in the seismically designed chemical cleaning building from the above grade storage curie iimitations.

This amendment does not authorize operations of Unit I subsequent to the chemical cleaning. The Commission will separately consider license modifications which may be required for resumption of operation at a later time.

A copy of the Federal Register flotice is also enclosed.

Sincerely, i

g b M9

\\d Harold R. Denton, Director 4[1 f C

E M

Office of fluclear Reactor Regulation 0

Enclosures:

y

/

1.

Safety Evaluation Supporting

  • SEE ATTACHED FOR PREVIOUS C0f1CURREtlCE

(, f

2.,Fe e a R is r flot ce DL:0RB' m, L:0RB #5/LA DL:0RB#5/AC DL:AD/SA DL:DIR f1RR:D/DIR flRR:DIR T57Pt

" * ' ' NT6556FIFj ll5ififG"" ~ '

"lT G iliHEh ~ ' Cl"ali"as"".. "..DUTieiiii"I"..'.E6si"~""""" UUEdIEd"" ~"

suo - o

..... ~. - ~ ~ ~

..............4...

11/9/81*

13/$/81

-. -.~./81

~ ~ -. ~. -.1

/

...../12/81

  • 11/.23. /81..*..~...... / /81 11

/ /8 oucy

~

OFFICIAL RECORD COPY usom mi-a.co unc ronu m oa.an uncu om

-l

I j

O' L

f C

= c.

o 3

I DISTRIBUTION:

l i

Docket RDiggs NRCPDR OELD j

LPDR OI&E (5)

Docket No. 50-10 TERA ACRS (10)

LS05 i NSIC BScharf (10)

ORB #5 RF GDeegan (4) l HDenton Xtra Cy (3)

ECase HSmith (2)

Mr. Byron Lee JCarter GCwalina Executive Vice President DEisenhut l

Commonwealth Edison Company Glainas Post Office Box 767 i

Chicago, Illinois 60690 TWambach P0'Connor

Dear Mr. Lee:

I

SUBJECT:

DECONTAMINATION OF DRESDEN STATI0fl UNIT 1 1,

{

In accordance with the Nuclear Regulatory Commission's Memorandum and Order (CLI-81-25) in the Matter of Commonwealth Edison Company (Dresden l

Nuclear Power Station Unit 1) Docket 50-10, September 28, 1981, I have determined that the activities authorized by Amendment No.

to Facility Operating License No. DPR-2 present no significant hazards consideration. Supporting documentation is provided in the enclosed 1

I

" Safety Evaluation by the Office of Nuclear Reactor Regulation Supporting Amendment No, to Facility Operating License No. DPR-2, Commonwealth Edison Company, Dresden ^ nit No. 1, Docket No. 50-10",

J j

dated November

, 1981, and the materials referenced therein.

J Accordingly, the Division of Licensing has issued, by a separate trans-mittal letter, Amendment No.

to License DPR-2.

e j

The amendment authorizes the chemical decontamination of the primary J

cooling system, revises the Technical Specifications to permit decon-j tamination without requiring containment integrity since there is no fuel in the reactor and the primary cooling system is depressurized.

q i

The amendment also authorizes the exclusion of the radioactive liquid storage tanks in the seismically designed chemical cleaning building

l from the above grade storage curie limitations.

A copy of the Federal Register Notice is also enclosed.

i l

Sincerely, 2

t i

Harold R. Denton, Director t

Office of Nuclear Reactor Regulation l

Enclosures:

l 1.

Safety Evaluation l

Supporting Amendment No.

to DPR-2 I

7.

Federal Reaister Notice

  • SEE ATTACHED FOR PREVIOUS CONCURRENCE 9.L,:gR,B,.,# 5/,Pt.,Q,L,:gRB,(p/LA p,L:,9,RB,,# 5/,AC,,h,[SA,,

o, na,

DL:DIR NRR:D/DIR NRR:DIR,,

i

.P0 '.C.o..n.n..o.r..:..r.jH S..m i t h..........

TW a..mb...a..c..h.......

..G..L..d....n. a.s....

DE.i se.nh.u..t..

.C as e.......

.HDe..n ton.......

E sumuo 7

....../..../81,,,,,),1,f9,/81*,,

,,,.,)J[,1,2/81*,

,,h,,/y,48,1.,

,,1,,18L,

,/,,,/81.,,,

,, /,,,,/81,,,,,,

om>

) NaC FOnu 318 00-80) MCM om OFFIClAL RECORD COPY uscea

_ m m

~

ht *Lo ft vy'9

,j UNITED STATES

,p 3

g NUCLEAR REGULATORY COMMISSION O

E W ASHINGTON. D. C. 20555 DISTRIBUTION:

Docket P0'Connor j

Docket No. 50-10 NRC POR RDiggs i

L505-81 LPOR OELD 1

TERA Ol&E (5)

NSIC ACRS (10)

ORB #5 RF BScharf (10)

Mr. Byron Lee HDenton GDeegan (4)

Executive Vice President ECase Xtra Cy (3)

Commonwealth Edison Company JCarter HSmith (2)

Post Office Box 767 DEisenhut y{

Chicago, Illinois 60690 Glainas j

DCrutchfield

Dear Mr. Lee:

TWambach M

SUBJECT:

DECONTAMINATION OF DRESDEN STATION UNIT 1 In accordance with the Nuclear Regulatory Comission's tiemorandum and Order (CLI-81-25) in the Matter of Commonwealth Edison Company (Dresden Nuclear Power Station Unit 1) Docket 50-10, September 28, 1981, I have determined that the activities authorized by Amendment No.

to Facility Operating License No. DPR-2 present no significant hazards consideration. Supporting documentation is provided in the enclosed

" Safety Evaluation by the Office of Nuclear Reactor Regulation Supporting Amendment No.

to facility Operating License No. DPR-2, p

Commonwealth Edison Company, Dresden Unit No. 1, Docket No. 50-10",

dated November

, 1981, and the materials referenced therein.

Accordingly, the Division of Licensing has issued, by a separate trans-mittal letter, Amendment No.

to License DPR-2.

The amendment authorizes the chemical decontamination of the primary cooling system, revises the Technical Specifications to allow deletion of requirements for primary containment integrity during the decontami-nation, and exclusion of the radioactive liquid storage tanks in the seismically designed chemical cleaning building from the above grade storage curie limitations.

A copy of the Federal Register Notice is also enclosed.

Sincerely, Harold R. Denton, Director Office of Nuclear Reactor Regulation

Enclosures:

1.

Safety Evaluation NRR:DIR' Supporting Amendment No, to DPR-2 HDenton FederalRegisterNoticep@Of

.4e 2.

g

/ /81 a

eg

..D.MO.R.D.g/.F.". 9L.19M..(5.l.V v

<n

...... '......P0 Connor:r, HSrf.i th~

L. T.Lp,.....

DLg,R,B,,,@,/A/A,0,(,: AD/M, D(; D I R,,,,,,,,

BRR:D/DIR.,,

.f.5 omce>

TWambach GClainas DEisenhut EGCase sua m e>

.O....\\............

l.l..............

.....l.....

om>

Nac ronu m now sacu om OFF1ClAL RECORD COPY usa m ini_ w,,e

Mr. Byron Lee December 18, 1981 cc w/ enclosures:

Isham, Lincoln & Seale Daniel Mintz, Esquire Counselors at Law Counsel for Petitioners

~

One First National Pliza, 42nd Floor (Citizens for a Better Environment)

Chicago, Illinois 50603 Suite 1600, 59 E. Van Buren Street Chicago, Illinois 60605 Mr. Doug Scott Plant Superintendent Mr. David L. Hetrick Rural Route #1 Professor of tiuclear Engineering Morris, Illinois 50450 University of Arizona Tucson, Arizona 85721 U. S. Nuclear Regulatory Commission Resident Inspectors Office Dr. Robert L. Holton i

Dresden Station School of Oceanography RR #1 Oregon State University

-l Morris, Illinois 60450 Corvallis, Oregon 97331 Mary Jo Murray Mr. L. De1 George Assistant Attorney General Director of fluclear Licensing Environmental Control Division Comonwealth Edison Company 188 W. Randolph Street Post Office Box 767 Suite 2315 Chicago, Illinois 60690 Chicago, Illinois 60601 Morris Public Library 604 Liberty Street Morris, Illinois 60451

~~

Chairman Board of Supervisors of Grundy County Grundy County Courthouse Morris, Illinois 60450 Illinois Department of Nuclear Safety 1035 Outer Park Drive, 5th Floor Springfield, Illinois 62704 U. S. Environmental Protection Agency i

Federal Activities Branch l

Region V Office ATTN:

Regional Radiation Representative

'l 230 South Dearborn Street Chicago, Illinois 60604 i

The Honorable Tom Corcoran United States House of Representatives Washington, D. C.

20515 John H. Frye, III, Chairtlan Atomic Safety and Licensing Board U. S. Nuclear Regulatory Commission

~t Washington, D. C.

20555

_