ML20039G631

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info Re FSAR Sections 13.1,13.2.2, 13.4 & 13.5.1
ML20039G631
Person / Time
Site: Seabrook  NextEra Energy icon.png
Issue date: 12/22/1981
From: Miraglia F
Office of Nuclear Reactor Regulation
To: Tallman W
PUBLIC SERVICE CO. OF NEW HAMPSHIRE
References
NUDOCS 8201180535
Download: ML20039G631 (8)


Text

_ _. _ _

g,--

w n

-c j

u o

DEC 2 2 BB1 g

A o

c.

Docket Nos.:

50-443/444 b

O

&cpp% ;

Dgg William C. Tallman

/Sg7

'/

~I j

Chairman and Chief Executive Officer e

Ed,4 x Public Service Company of New Hampshire 1!,

P. O. Box 330 l' '

Manchester, New Hampshire 03105 s

Dear Mr. Tallman:

Subject FSAR Chapter 13 Review

Reference:

NRC Letter dated December 17, 1981,

Subject:

FSAR Section 13.1 Review The reference letter forwarded requests for information to support the NRC staff review of FSAR Section 13.1 and indicated that applicant representatives should be prepared to describe responses at a meeting on January 4-6, 1982.

Further review of Section 13.1 and a preliminary review of Sections 13.2.2, 13.4 and 13.5.1 identified additional areas for which more information'1s' required. Enciosed is a descr ption of these additional concerns.

As with the previously forwarded Chapter 13 cnncerns, applicant representatives she ld be preparM to discuss responses at the January 4-6, 1982 meeting.

There will be no additional requests for infonnation prior to that meeting.

Sincerely, Original signed by Freuik J. Miraglia Frank J. Miraglia, Chief Licensing Br ch No. 3 Division of Licensing

Enclosure:

As stated cc: See next page.

l DISTRIBUTI0fi:

l Docket File 50-443/444 LLWheeler LPDR TERA PDR LB#3 Files NSIC FMiraglia omce >l DL :LB#}

DL:L 8201180535 811222

.' l i a

$DRADOCK 05000443 T

uc.aw,> i.'LWhteler:jl PDR u....

ocu p.

12/Jh81 12

/81 y....

nac eow mmo smuscu ono.

OFFICIAL RECORD COPY

' " 'o * =

x

SEABROOK William C. Tallman Chairman and Chief Executive Of ficer Public Service Company of New Hanpshire P. O. Box 330 Manchester, New Hampshire 03105 E. Tupper Kinder, Esq.

John A. Ri tscher, Esq.

Assistant Attorney General Rap;s and Gray Office of Attorney General 225 Franklin Street 208 State House Annex

~

Boston, Massachusetts 02110 Concord, New Hampshire 03301 Mr. B'ruce B. Beckley, Project Manager The Honorable Arnold Wight e

Public Service Company of New Hampshire New Hanpshire House of Representatives P. O. Box 330 Science, Technology and Energy Committee Manchester, New Hampshire 03105 State House Concord, New Hanpshire 03301 G. Sanborn U. 5. NRC - Region I Resident Inspector' 631 Park Avenue Seabrook Nuclear Power Station 19406 King of Prussia, Pennsylvania c/o U. S. Nuclear Regulatory Commission P. O. Box 1149 Ms. Elizabeth H. Weinhold S' abrook, New Hampshire 03874 e

3 Godfrey' Avenue Haupton, New Hampshire 03842 x

Mr. John DeVincentis, Project Manager Yankee Atomic Electric Canpany Robert A. Backus, Esq.

1671 Worcester Road O'Neill, Backus and Spielman Farmingham, Massachusetts 01701 116 Lowell Street Manchester, New Hampshire 03105 Mr. G. F. Cole, Project Manager United Engineers and Constructors Norman Ross, Esq.

30 South 17t2 Street

~~

30 Francis Street Post Office Box 8223 Brookline, Massachusetts 02146 Philadelphia, Pennsylvania 19101 Karin P. Sheldon, Esq.

Mr. W. Wright, Project Manager Sheldon, Harmon & Weiss Westinghouse Electric Corporation 1725 1 Street, N. W.

Post Office Box 355 s' Washington, D. C.

20006 Pittsburg, Pennsylvania 15230 Laurie Burt, Esq.

Thomas Dignan, Esq.

Office of the Assistant Attorney General Ropes and Gray Environmental Protection Division 2E5 Franklin Street One Ashburton Place Boston, Massachusetts 02110 Boston, Massachusetts 02108 D. Pierre G. Cameron, Jr., Esq.

General Counsel t

Public Service Company of New Hampshire l

i P. O. Box 330 Manchester, New Hampshire 03105 l

l

.n

v

. _ _ _.._._.r -

ENCLOSUR,E 1.________

l

~.

s s

.z-

'0u3stions For'FSAR Section 13.1.2

(

630.6 Regarding th(Operations ' organization described in' FSAR Sections

.13.1.2' 1 and 13.1.2.2.b:

_ Commit.to a five shift crew rotation or demonstrate.that re-

_ (a) maining in four operating crews will not result in excessive overtime situ 6tions for your staff.

. (b) Clarify the position of the Assistant Operatio'ns Manager in#

the line of succession to the Station Manager's authority.

i630.7.- Regarding the Technical Services organization described in FSAR Section 13.1.2.2.c:

(a) D'e'stfib'e the ' duties,' responsibilities and authority of the

~ Assistant Technical Services Manager.

(b) Describe the extect.of involvement of the, Technical Services organization in the Initial Test Program.

630.8 Regarding FSAR Section'13.1.2.2.d, describe the Training staf f's capability to conduct general employee, radiation protection and..

non-licensed personnel technical training.

Include a discussion of the number of people assigned to the Training staff ar.d describe their qualifications.

630.9 Regarding Shift Staf fing as described in FSAR Section 13.1.'2.3 and in Proposed Technical Specification 6.2.

(a) Commit 'to having a rad / chem technician er. site at ali 't' ices

-hen a unit is in Medes 1-c or justify nc-doing so.

(b) Commit to having a Shif t Technical Advisor who meets the requirements and qualifications discussed in Item I. A.1.1 of t:UREG-0737 onsite at a.11 times wnen a unit is in Mcce; l-4.

d e

e

.a

o

-~-----* *- 7 -~~~'

~ ^ ~ ~ ' ^

' ~ '

  • 7

_r r.

.l

}

3.

I j

> - Cuestions For FSAR Section 13.1.3 r

I

'.e,630.10 Regarding the ' qualifications of plant personnel described in FSAR Section 13.1.3:

(a) -Neither the Station Manager nor the Assistant Station Manager-h.a i t. i *;

appears to have indepth experience in the overall management

~.

I

- of an operating commercial nuclear power plant.

Describe.

the steps you are taking to provide this experiende for the senior plant staff.

e.

(b) for the Technical Services organization:

(i.)

. Describe, in detail,. the experience of the incumbent Maintenance Depa,rtm.en.t Supervisor in.the electrical,

maintenance area and d'iscuss his knowledge of applicable

. electrical codes.

(ii.) Describe, in deta.il, the qualification and experience of the Electrical Supervisor.

(iii.) Describe the steps you have taken to ensure an adequate level of electrical experience within the' Maintenance Department.

(iv.)

Explain why the designated level of cualification listed in this section for the Instrumentation and.

~~

Control Department Supervisor is " Prof f essional-Technical" instead of " Supervisor Not Requiring an NRC License."

(c)

Although the incur. bent Trair.ing Manager has an extensive background in the field of education, he appears to lack specific experience in the area of nuclear power plant training.

Describe the steps ycu have taten to provide th.is specific experience within the Training Organt:ation.

O e

t O

,~,,~ ",

^

- - - + - -

~.

~,

q 9.

,,.J

' (d). Describe'the Ad:ninistrative Procedures governing the Initial

?'

T

,'*, e

~ Test Program...Your discussions should include details of.

a * '.. i. '

the procedures that control:

" ? % I ] l{

q.: 4:,.. ' d,.. b. 1., Thei development of ' individual test procedures. 3,6.-

11..The conduct of the various phases of the test program.

I 111. The review, evaluation and approval ofr test 'results,.

  • i i. ; e.'

and i.?

  • l i...

....i v.

The selection of individual:to perform the tests.

c. -

~-.,

(e) Describe the Administrative Procedures implemented to:

l

{.

Substantially relieve the Shif t Supervisor of routine administrative duties.

11.

Establish the overtime policy for members of the plant 1

staff.

t lii. Establish the organizational lines of succession; and provide for the delegation of the Station Manager's i

authority including his authority to issue Special and Standing Orders.

b.

e I

e e

e an.

.e e

e

~ ~ ~ ~ ~ ~~

~

' 4:-

~

7 4

\\

.. ~

,_ l t,.

Questions For FSAR Section 13.2,jsER 13.2.2},

,. - - i '

7

~

630.11 s 4 Describe, in detail, your Shif t Technical Advisor (STA) training i

0' program.

Include in your description:

.u...,;,.;

~

3 a.

.The approximate duration in' weeks. for each segment of the program.

b.

The number of STA's being trained and the chrrent position i

.J!

titles for these STA's.

~ 5-A comparison of the STA training program to the program c.

v 1

described.in Appendix C of NUREG-0737..

~

d.

Mileston~e date, in months prior to Fuel Load, for completion of your initial STA training program.

A discussion of the STA retraining and replacement training e.

~

~

program.

l f.

A discussion of the remedial training requirements for an ~

STA who has been absent from STA duties for a period of 30 days or longer.

630.12 Describe your plans for conducting the Position Task Analysis program di scus sed in Item 1. A.2.2 of NUREG-0660.

I 630.13 Figure 13.2-1 shows the training milestone dates -for Licensed 3

Operator Training. Provide a chart similar to Figure 13.2-1 which shows the training milestones for each of the other major crpr.ni ational units discussed in FSAR Section 13.1.2.

' 630.14 Frevida information showing the extent of completion of each of i

l your training programs as of January 1.1982 and discussing your u,

1 centingency plans for these programs if the Fuel Load date is

?-

Significantly delayed.

53C.15 Explain the methuds you will use to evaluate the ef fectivsness of, the STA and non-licensed training programs and to provide an evaluation of each employee involved.

l 630.16 Regarding the non-licensed personnel training program described in FSAR Section 13.2.1.1.d:

a.

Elaborate on the training you will give to supervisors and technical personnel.

]nclude in your discussion, the courne cor. tent, duration in weeks for each major segment, the teaching organization and the nu-ber and pcsition titles of the expected trainees.

-1

c.

.. ~;. -

~

~

~

~

t

. p :! -

b.

Similarly, describe ~ the training which you will give to the j

.. techniciansi and.craf tsmen' in your Technical. Services organizatiori. :.

, ;. i.

i c.

. '. Describe the Auxiliary Operator training prog ~ ram.

3 l l..

630'.17. ~ DDescribe your. training given [n response to Item II.B.4 'of NUREG ' - h. I'i -

3.i ~..

e;-.-

. ' 0737 " Training For Mitigating Core Damage" include:

' ' a. : A syllabus or description of course content,.

- i.

b.

' The number. and position titles of the trainees.

. p -

'c.

Identification of the teaching organization.

-d.

A differentiation between the classiccm and on-the-job training aspects of the t.cogram.

The retraining and replacement training provi:; ions for the e.

program.

f.

A description of the program evaluation mechanism.

O so l e

p

-e=.

I i

l l

I

J

,, - l.

,_7_-

o

.. l -

~

r.

,. 3

~

.f

- }

...l-

,Quastions For FSAR' Section 13.4 v

In regard to the description of the facility's Revi'ew and Audit -

P i 630.18. Program presented in Section 13.4 provide the details pertaining c.,:,..; > a, to the: Review and Audit Program developed in accordance with the Ii

' guidelines of ANSI N18.7-1976 as endor. sed by Regulatory Guide '

g

- 1.33.. :

s.

. In regard to the discussions of the On Site Revi'ew Committee in

'.630.19.

- ~

Section 13.4,.1, provide the following:

,;...~.

(a')# A description of the Coxnittee's charter.

Discuss Committee review responsibilities regarding the (b)

Initial Test Program.

('c) A description of the provisions for maintaining Committee eP meeting minutes.

~

In regard to the description of the Nuclear -Safety Audit and 63D.20 Review Committee in Section 13.4.2 provide:

i (a) A description of the committee's charter.

(b) Resumes or cther qualification details of its members.

A description how the qualifications of the members := set the (c) requirements of Section 4.7 of ANS 3.1-1978.

630.21' Your discussions in Chapter 13, did not address the f acility's Safety Engineering Grou:.

Please previde your plar.s Independent to establish the Independent Saf ety Engineering Group in a.ccordance with the cuidelines furnished in Item 1.B.l.2 of NUREG-06ED and i NU'EG-0737.

4 4

C estions For FSAR_Section 13.5.1 vith reference to the discussions of Administrative Procecures 4

630.22 presented in Section 13.5.1:

FSAR Section 1,8 references Revision 3 of Regulatory Guide (a) l.33 vhile. FSAR Section 13.5.1 references Revision 2 of this

(

Regulatory Guide.

Resolve this Discrepancy.

Describe how the Administrative Procedures will comply with (b) the requirements of ANSI N18.7-1976.

Identify the persons (by position) res'ponsible for the (c) dev el o p-e r.t, 4.plementatica and cer. trol of the Ad.-ieistrative proceduros.

h

'I l

.