ML20039B813
| ML20039B813 | |
| Person / Time | |
|---|---|
| Site: | San Onofre |
| Issue date: | 12/04/1981 |
| From: | Papay L SOUTHERN CALIFORNIA EDISON CO. |
| To: | Engelken R NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| 10CFR-050.55E, 10CFR-50.55E, NUDOCS 8112230587 | |
| Download: ML20039B813 (3) | |
Text
-_
Docket No. 50-361 50 55(o) Report
.)
Southem California Edison Company h5 RO. BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD, CAUFORNIA 98770
- n. m...~
m..n.,n.
December 4, 1981
/J D
Mr. R. H. Enge lke n, Director g
lg i
U. S. - Nuclear Regulatory Commission D
k gC'p~')
Of fice of Inspection and Enforcement
~/
C Cg8/gglA -
, 10 Region V tD %
- Z Rf
%.,g,f4Q%
1450 Maria Lane, Suite 210 4
8 Walnut Creek, California 94596-5368
- e. >
s
Dear Mr. Engelken:
' #k$7,-[pN Subj ec t:
Docke t No. 50-362 San Onofre Nuclear Generating Station, Unit 3 In a letter to your. office dated October 26,1981 we identified a condition which we consider reportable in accordance with 10CFR50.5 5 (e).
The condition involves reflector indications noted during ultrasonic testing performed for Preservice Examination (PSE) of the Unit 3 Reactor Pressure Vessel.
Enclosed in accordance with 10CFR50.55(e) a~re twenty-five (25) copies of a Final-Report entitled, " FINAL REPORT ON PRESERVICE ELAMINATION INDICATIONS DISCOVERED IN UNIT 3 RFACTOR PRESSURE VESSEL."
If you have any questions regarding this report, we would be pleased to discuss this matter with you at your convenience.
1 Very truly yours,
/
7P Enclosure s 1AE3103 cc:
Victor Stello (NRC, Director I&E)
A. E. Chaffee (NRC, San Onofre Units 2 and 3) g q) g; 6-23 O
\\E%7 Ota 8112230587 811264 QMBON yDRADOCK 05000362 2 f,
~ PDR.
bI-2ik j
L..
F 1
s %
Final Report on the Preservice Exmaination Indications Discovered in.thit 3 Reactor Pressure Vessel San Onofre Nuclear Generating Station, Units 2 & 3 INTRODUCTION This report is submitted pursuant to 10CFR50.55(e) (b).
It 3
describes a. condition involving reflector indications obtained by ultrasonic testing during preservice examination of the Reactor Pressure Vessel for Unit 3 in accordance with ASME BPVC,Section XI.
This report includes a description of the condition, an analysis of the safety implications, and a summary of corrective action taken.
By letter dated October 26, 1981, Edison confirmed notification to the NRC of this condition.
By letter dated November 20, 1981, Edison requested an extension on the time to December 7,1981, for submission of a final report in accordance with 10C FR5 0. 55(e) (3).
BACKGROUND '
During the Preservice Examinar. ions (PSE) of the Unit 3 Reactor Vessel, six reflector indications were noted by Ultrasonic Te stin g.
These indications were rejectable under the PSE criteria which is used for establishing a baseline for inservice inspections.
The indications were located in the lower part of the three long seams in the intermediate shell course, near the outside surface.
DISCUSSION The following discussion is responsive to 10CFR50.55(e)(3).
Description of Deficiency The ultrasonic preservice examination indications were found in the longitudinal weld seams at 3300, 2100 and 900 near the bottom of the internediate shell girth weld.
They appeared to be aligned in parallel to the longitudinal weld centerline at the weld fusion line.
The actual extent of the indications could not be accurately determined due to their proximity to the outer surface.
These six indications were evaluated for size from the outer surface by means of Distance Amplitude Curve (DAC) technique.
All of the indications except those in weld at 3300 were of spot size in length.
Those at 3300 showed some lateral width of less than 3/4 inch.
All three welds were found unacceptable based on ASME BPVC Section XI.
Analysis of Safety Implications The six indications in the long seam welds were just above the lower-to intermediate shell girth seam and very close to the outside surface.
There is extra stock on the vessel wall
ig e
over minimum required thickness at this point.
If the vessel wall is ground to minimum wall thickness (8.448")
the allowable indication for baseline inspection under ASME BPVC, l
Section XI is 0.035 x 8.448=0.30".
Indications of less than this depth can remain.
An evaluation of the expected growth of a 0.3" deep x 0.6" long surface flaw in an 8.535" thick vessel wall has been performed using all of the San Onofre 3 design transients.
It is predicted that the flaw depth will increase by 0.0027 inches in the 40 years life.
This evaluation is consistent with other analysis of similar situations.
In addition, the plant operating limits are based on assumed flaws of much greater size than the evaluated indications.
Therefore, these indications would not place a restriction on operation. -
CORRECTIVE ACTION A repair procedure, C-E Procedure No. 72170-4, Revision 1, was generated for the repair work.
The procedure essentially called for grinding to remove or to reduce the size of the indications to make them acceptable in accordance with ASME BPVC,Section XI.
To complete the repair in accordance with the Code, the excavated area will be blended into the surrounding material.
The final acceptability of the indication will be determined following blending and repeating the preservice examination.
l
.