TABLE 3.2-1 (continued)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Number of Samples Exposure Pathway and Sampling and Type and Frequency and/or sample Sample Locations **

Collection Frequency of Analysis

4. INGESTION a.

Milk A minimum of' 4 locations At least once per 15 days Gamma isotopic and e-from Table 5 of the ODCM.

when animals are on pasture; I-131 analysis "G

at least once per 31 days of each sample.

g at other times.

Sr 90 analysis by composites ao for each location shall be 9@

conducted at least once per o

92 days.

uto 8C b.

Fish and o88 Invertebrates A minimum of 2 locations One sample in season, or at Gamma isotopic analysis crow from Table 6 of the ODCM.

least once per 184 days if on edible portions.

not seasonal One sample of each of the following species:

1.

Preditor (channel catfish or Bluegill or Pumkinseed).

2.

Prey c.

Food Products A minimum of 4 locations At time of harvest. One Gamma isotopic analysis from 1able 7 of the ODCM sample of each of the fol-on edible portion.

(when available).

lowing classes of food products:

1.

Fruits 2.

Vegetables Indicator Location and At time of harvest. One I-131 analysis.

I Control Location sample of broad leaf vegetation i

    • Sample locations are shown on the figure in the ODCM.

j 3.2-5 k