ML20037D255

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info Re Util Responses to NRC Review of Application for Authorization for Receipt, Possession,Storage,Insp & Preparation of Transport of SNM
ML20037D255
Person / Time
Site: Comanche Peak, 07002932  
Issue date: 05/21/1981
From: Ketzlach W
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Gary R
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
References
NUDOCS 8106010691
Download: ML20037D255 (2)


Text

_

Q, ;,,,L G ?.t Distribution:

M9 p-Docket File 70-29331 (---

50-445 1

50-446 PDR.

i MAY ? 11981 LPDR

-,=-

FCUP:NK gg33 pff 70-2932 FCUF r/f FCUP r/f NKetzlach LTyson WTCrow IE HQ (2)

Texas Utilities Generating Company RGPage ATTN: Mr. R. J. Gary DJKasun Executive Vice President and JBBurwell General Manager MURothschild 2001 Bryan Towers RGTaylor Dallas, Texas 75201 Service List Gentlemea:

I ha<e discussed with your Mr. B. W. Coss your coments (dated April 3,1981) on our review of your application requesting authorization for the receipt, possession, storage, inspection and preparation for transport of special nuclear material required for the operation of the Comanche Peak Steam Electric Station Unit 1.

Your responses to all our coments were not complete. The additional infomation needed to complete our review (see enclosure) was--

discussed with Mr. Coss on April 28 and May 12, 1981. Although he had satis-factory answers _to our coments, he infomed me you would not formally respond to them until you had dur c~omments on your earTier response in writirig. He also requested authorizat1Dn ~for several inspection st~ations at your facility.

The additional time you are requesting to respond to our comments could extend our schedule to complete the review of your application by about one month, depending on the time of receipt.of your responses.

If there are any questions concerning this matter, please call me at 301-427-4510.

Sincerely, Original Signed by N. Ketzlach Nonnan Ketzlach Uranium Process Licensing Section Uranium Fuel Licensing Branch Division of Fuel Cycle.and Material Safety

Enclosure:

Coments to License Application for Fuel Storage Only

. 7,..... FCUP. 4.(.

c.. c M,.. F....'. s/ ! FCUF A

.. q.

~ +..Nxe iach:ratT u n wrCrsw..

~

"" t

. 5/1.9/al.

..s/.40.8),,,

,.5/.71.g1.,,

1

[<

OFFICIAL RECORD COPY

" *-3:n nac reau ais oo seisacu cao m a m n c. c n

f. ~.

~

[.

Connents on Texas Utilities Generating Company

~r-Supplement (Dated April 3,1981) to License Application For Fuel Storage Only at Unit 1 Comanche Peak Steam Electric Station (Dated July 10, 1980) 1.

Section 1.2.1 Since you plan to temporarily store fuel assemblies in their shipping containers, include the request in your application and specify the location and minimum distance (>20 feet from the fuel storage racks and

>12 feet from the fuel inspection stations) the shipping container array of assemblies will be fran other fuel.

2.

Sectior 2.2 Provide administrative controls to ensure each assembly is loaded into the spent fuel pool racks in a checkerboard pattern.

" Periodic" loading verification is too vague.

3.

Section 2.2 a.

If desirable to have more than one inspection station, specify the

' minimum distance between stations and between stations and storage arrays (>12 feet is satisfactory).

b.

Confirm the plastic covering around each fuel assembly in the new fuel storage rack is open at the bottom to allow water drainage from the assemblies in the event of flooding and subsequent drainage of the storage area.

c.

Confirm a metal cover is positioned over each section of the new fuel storage racks after each storage rack section is loaded.

~

. -