ML20037B068

From kanterella
Jump to navigation Jump to search
Notice of Deviation from Insp on 771107-11
ML20037B068
Person / Time
Site: Dresden  
Issue date: 12/13/1977
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20037B065 List:
References
50-010-77-34, 50-10-77-34, 50-237-77-31, 50-249-77-29, NUDOCS 8009030771
Download: ML20037B068 (1)


Text

.

)

Appendix A NOTICE OF DEVIATION Commonwealth Edison Docket No. 50-10 Company Docket No. 50-237 Docket No. 50-249 Based on the inspection-conducted on November 7-11,1977, it appears that certain of your activities were not in accordance with commitments, codes, standards, guides, or acceptable practices, as noted below.

Contrary to Section 9.1, Paragraph 7, of the Generating Stations Emergency Plan.(GSEP), the licensee failed to conduct an annual review of the emergency plan implementing procedures for'the Directors of the following GSEP groups: command center; intelligence, medical, information; manpcwer and logistics, communications, aerial logistics, accounting; legal; engineering; system power supply load dispatcher; and the six division group directors.