LIKERICK GENERATING STATION j

UNITS 1 and 2 I

i Docket Nos. 50-352 50-353 4

i License Nos. WPF-39 l

NPP-85 i

I TECHNICAL SPECIFICATION CRANGE REQUEST I

i No.

89-14

[

I 1

l t

i t

a.

List of Attached Pages 3/4 0-2 Unit I I

B 3/4 0-4 Unit 1 i

3/4 0-2 Unit 2 i

B 3/4 0-4 Unit 2 l

i 1

?

l l

,oo4too433 900323 P,DR ADoCKc5 cog ((g2 F

r i

APPLICABILITY

,$URVEILLANCE REQUIREMENTS 4.0.1 Survei11cnce Requirements tha11 be met during the OPERATIONAL CONDITIONS or other conditions specified fcr individual Limiting Conditions for Operation unless otherwise stated in an indivioual Surveillance Requirement.

4.0.2 Each Surveillance Requirement shall be performed within the specified surveillance interval with a maximum allowable extension not to exceed 25% of the surveillance interval.

4.0.3 Failure to perform a Surveillance Requirement within the allowed surveillance interval defined by Specification 4.0.2. shall constitute noncompliance with the OPERABILITY requirements for a Limiting Condition for Operation. The time limits of the ACTION requirements are applicable at the time it is identified that a Surveillance Requirement has not been performed. The ACTION requirements may be delayed for up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to permit the Completion of the surveillance when the allowable outage time limits of the ACTION requirements are less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Surveillance requirements do not have to be performed on inoperable equipment.

4.0.4 Entry into an OPEP,ATIONAL CONDITION or other specified applicable condition shall not be made unless the Surveillance Requirement (s) associated with the Limiting condition for Operation have been performed witnin the appitcable surveillance interval or as otherwise specified. This provision shall not prevent passage through or to OPERATIONAL CONDITIONS as required to comply with ACTION requirements.

4.0.5 Surveillance Requiremerts for inservice inspection and testing of ASME Code Class 1. 2, & 3 components shall be applicable as followst Inservice inspection of ASME Code Class 1. 2. and 3 components and a.

inservice testing of ASME Code Class 1. 2. and 3 pumps and valves shall be performed in accordance with Section XI of the ASME Boiler and Pressure vessel Code and applicable Addenda as required by 10 CFR Part

50. Section 50.55a(g), except where specific written relief has been granted by the Commission pursuant to 10 CFR Part 50. Section 50.55a(g)

(6) (i).

b.

Surveillance intervals specified in Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda for the inservice inspection

  • and testing activities requ ked by the ASME Boiler and Pressure Vessel Code and applicable Addenda shall be applicable as follows in these Technical Specifications:

(

LIMERICK - UNIT 1 3/4 0-2

___------.-----J

1/U.0 RULICAB!t !W

~

~~

~

~

BA$l$

j I

operational status of systems and components and that parameters are within specified limits to ensure safe operation of the facility when the plant is in an i

OPERATIONAL CONDITION or other specified condition for which the individual Limiting Conditions for Operation are applicable. Surveillance Requirements do I

not have to be performed when the f acility is in an OPERATIONAL CONDITION for which the requirements of the associated Limiting Condition for Operation do not apply unless otherwise specified.

The Surveillance Requirements associated with a

~

$pecial Test Exception are only applicable when the Special Test Exception is used as an allowable exception to the requirements of a specification.

Specification 4.0.2 establishes the limit for which the specified time interval i

for Surveillance Requirements may be extended.

It permits an allowable extension i

of the normal surveillance interval to facilitate surveillance scheduling and consideration of plant operating conditions that may not be suitable for conducting the surveillance; e.g., transient conditions or other ongoing surveillance or maintenance activities.

It also provides flexibility to accommodate the length of a fuel cycle for surveillances that are performed at each refueling outage and are specified with an 18. month surveillance interval.

it is not intended that this provision be used repeatedly as a Convenience to i

extend the surveillance intervals beyond that specified for surveillance $ that are L

not performed during refueling outages.

The limitation of Specification 4.0.2 is l

based on engineering judgment and the recognition that the most probable result of i

any particular surveillance being performed is the verification of conformance with the Surveillance Requirements. This provision is sufficient to ensure that l

the reliability ensured through a surveillance activities is not significantly i

degraded beyond that obtained from the specified surveillance interval.

l Specification 4.0.3 establishes the failure to perform a Surveillance Requirement I

within the allowed surveillance interval, defined by the provisions of specification 4.0.2, as a condition that constitutes a f ailure to meet the f

OPERABILITY requirements for a Limiting Condition for Operation.

Under the i

provisions of this specification, systems and components are assumed to be OPERABLE when Surveillance Requirements have been satisfactorily performed within

[

the specified time interval. However, nothing in this provision is to be construed as implying that systems or components are OPERABLE when they are found

[

or known to be inoperable although still meeting the Surveillance Requirements.

l This specification also clarifies that the ACTION requirements are applicable when Surveillance Requirements have not been completed within the allowed surveillance i

interval and that the time limits of the ACTION requirements apply from the point -

i in time it is identified that a surveillance has not been performed and not at the time that the allowed surveillance interval was exceeded.

Completion of the Surveillance Requirement within the allowable outage time limits of the ACTION

[

requirements restores compliance with the requ, aments of Specification 4.0.3.

l However, this does not negate the fact that the failure to have performed the surveillance within the allowed surveillance interval, defined by the provisions of Specification 4.0.2, was violation of the OPERABILITY requirements of a Limiting Condition for Operation that is subject to enforcement action.

Further, t

the failure to perform a surveillance within the provisions of Specification 4.0.2 constitutes a failure to meet the OPERABILITY requirements for a Limiting Condition for Operation and any reports required by 10 CFR 50.73 shall be determined based on the length of time the surveillance interval has been exceeded, and the corresponding Limiting Conditions for Operation ACTION time

[

requirements.

i l

LIMERICK - UNIT 1 B 3/4 0-4

fPDLICABIL19y

.SURVE!LL.ANCE REQUIREMENTS 4.0.1 Surveillance Recuirements shall be met during the OPERATIONAL CONDITIONS or other conditions specified for individual Limiting Conditions for Operation unless otherwise stated in an individual Survetilance Requirement.

4.0.2 Each Surveillance Requirement shall be performed within the specified surveillance interval with a maximum allowable extension not to exceed 25% of the surveillancc interval.

4.0.3 Failure to perform a Surveillance Requirement within the allomed surveillance interval defined by Specification 4.0.2, shall constitute noncompliance with the OPERABILITY requirements for a Limiting Condition for l

Operation.

The time limits of the ACTION requirements are applicable at the time it is identified that a $urveillance Requirement has not been performed.

The ACTION requirements may be delayed for up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to permit the completion of the surveillance when the allowable outage time limits of the ACTION requirements are less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Surveillance requirements do not have to be performed on inoperable equipment.

4.0.4 Entry into an OPERATIONAL CONDITION or other specified applicable Condition shall not be made unless the Surveillance Requirement (s) associated with the Limiting Condition for Operation have been performed within the applicable surveillance interval or as otherwise specifiGd.

This provision shall not prevent passage through or to OPERATIONAL CONDITIONS R$ required to Comply with ACTION requirements.

4.0.5 Surveillance Requirements for inservice inspection and testing of ASME Code Class 1, 2, t, 3 components shall be applicable as follows:

a.

Inservice inspection of ASME Code Class 1, 2, and 3 components and inservice testing of ASME Code Class 1, 2, and 3 pumps and valves shall be performed in accordance with Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda as recuired by 10 CFR Part 50, Section 50.55a(g), except where specific written relief has been granted by the Commission pursuant to 10 CFR Part 50. Section 50.55a(g)

(6) (i).

b.

Surveillance intervals specified in Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda for the inservice inspection -

and testing activitie$ recuired by the ASME Boiler and Pressure Vessel Code and applicable Addende shall be applicable as follows in these Technical Specifications:

l l

l l

LIMERICK - UNIT 2 3/4 0-2

C 3/4.0 AEPLICABILITY BASES operational status of systems and components and that parameters are within specified limits to ensure safe cperation of the facility when the plant is in an OPERATIONAL CONDITION or other specified condition for which the individual Limiting Conditions for Operation are applicable.

Surveillance Requirements do not have to be performed when the facility is in an OPERATIONAL CONDITION for which the requirements of the associated Limiting Condition for Operation do not apply unless otherwise specified. The Surveillance Requirements associated with 6 Special Test Exception are only applicable when the Special Test Exception is used as an allowable exception to the requirements of a specification.

Specification 4.0.2 establishes the limit for which the specified time interval for Surveillance Requirements may be extended.

It permits an allowable extension of the normal surveillance interval to facilitate surveillance scheduling and consideration of plant operating conditions that may not be suitable for conducting the surveillance; e.g., transient conditions or other ongoing surveillance or maintenance activities.

It also provides flexibility to accommodate the length of a fuel cycle for surveillances that are performed at each refueling outage and are specified with an 1B-month surveillance interval.

It is not intended that this provision be used repeatedly as a convenience to extena the surveillance intervals beyond that specified for surveillances that are not performed during refueling outages.

The limitation of Specification 4.0.2 is basedonengineeringjudgmentandtherecognitionthatthemostprobableresultof any particular surveillance being performed is the verification of conformence with the Surveillance Requirements. This provision is sufficient to ensure that I

the reliability ensured through a surveillance activities is not significantly degraded beyond that obtained from the specified surveillance interval.

Specification 4.0.3 establishes the failure to perform a Surveillance Requirement within the allowed surveillance interval, defined by the provisions of specification 4.0.2, as a condition that constitutec a f ailure to meet the OPERABILITY requirements for a Limiting Condition for Operation.

Under the provisions of this specification, systems and components are assumed to be OPERABLE when Surveillance Requirements have been satisfactorily performed within the specified time interval. However. nothing in this provision is to be construed as implying that systems or components are OPERABLE when they art found or known to be inoperable although still meeting the Surveillance Requirements.

This specification also clarifies that the ACTICN reovirements are applica01e when Surveillance Requirements have not been completed within the allowed survelliance interval and that the time limits of the ACTION requirements apply from th9 point in time it is identified that a surveillance has not been performed and not at the time that the allowed surveillance interval was exceeded.

Completion of the Surveillance Requirement within the allowable outage time limits of the ACTION requirements restores compliance with the requirements of Specification 4.0.3.

However, this does not negate the fact that the failure to have performed the surveillance within the allowed surveillance interval, defined by the provisions of Specification 4.0.2, was violation of the OPERABILITY requirements of a Limiting Condition for Operation that is subject to enforcement action.

Further, the failure to perform a surveillance within the provisions of Specification 4.0.2 constitutes a failure to meet the OPERABILITY requirements for a Limiting Condition for Operation and any reports required by 10 CFR 50.73 shall be determined based on the length of time the surveillance interval has been exceeded, and the corresponding Limiting Conditions for Operation ACTION time requirements.

l LIMERICK - UNIT 2 B 3/4 0 4 l