YANKEE ATOMIC ELECTRIC COMPANY y.
hk 1671 Worcester Road, Framingham, Massachusetts 01701 3gg3 ANKEE FYR 81-147 October 29, 1981 United States Nuclear Regulatory Commission Region I 6 31 Pa rk Avenue King of Prussia, PA 19406 Attention:
Mr. Ronald C. Haynes, Director Region I Office of Inspection and Enforcement
References:
(a) License No. DPR-3 (Docket No. 50-29) j (b)
I6E Letter to YAEC dated July 16, 1981, I6E Inspection 50-29/81-07 (c) YAEC Letter to USNRC dated August 7, 1981, ( FYR 81-122 )
(d)
I&E Letter to YAEC dated October 15, 1981, I&E Inspection 50-29/81-07
[
Subject:
Supplemental Response to Inspection 50-29/81-07
Dear Sir:
]
This letter is in response to Reference (d) in which you indicate an item of non-co npliance exists as indicated in Reference (b).
Response
It is our position that the Plant Operations Review Committee (PORC) should not have to review and approve the procedures utilized by' the approved vendor in the performance of work in their area of specialization. l The plant has used Teledyne Isotopes to perform the analysis of Sr-89,;Sr-90,and C-14 for a number of years and has verified that thevendorcouldcorfectlyperform the analysis. This was accomplished by sending spiked sample,s 'to the vendor f or analysis and comparing his results to the known.
c.
Based on this position, we believe that a non-compliance does not exist relative to this item and that the item should be withdrawn. Even so, we wish to further indicate that the vendor's procedures (marked proprietary) were obtained subsequent to our initial response, Reference (c), and they have been reviewed and approved by PORC as indicated in PORC Meeting Minutes 81-47.
We trust this information is satisf actory, however, should you desire additional information, please feel free to contact us.
Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY
/
Y
/
.M dy 8112010432 G11117 Manager of Operations PDR ADOCK 05000029 G
-