Text
}
s o
s ATTACHMENT I PROPOSED TECHNICAL SPECIFICATIONS CHANGES RELATED TO TEST OF THE OFF-GAS ISOLATION FEATURE POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A.
FITZPATRICK NUCLEAR POWER PLANT DOCKET NO. 50-333 8111300356 811123 PDR ADOCK 05000333 PDR p
p LIMITING CONDITIONS FOR OPERATION 9.
One exhaust vent monitoring system on each build-9.
All gaseous effluent monitors shall be ing and one plant stack monitoring system shall be calibrated at least quarterly by means of a operating and one offgas radiation monitor shall be check source and annually with a known radio-operating whenever steam pressure is available to active source. Each monitor shall have an the air ejectors.
If these requirements are not instrument channel test at least monthly and satisfied, a shutdown shall be initiated so that sensor check at least daily.
the reactor will be in the hot standby condition within 10 hr in the case of the stack monitor or 10 days in the case of the building ven'. monitor.
10.
The containment shall be purged through the Standby 10.
Autanatic initiation and closure of the Gas Treatment System.
Offgas Systan shall be verified at least once per operating cycle.
W
ATTACHMENT II SAFETY EVALUATION RELATEO TO TEST OF THE OFF-GAS ISOLATION FEATURE j
POWER AUTHORITY OF THE STATE OF NEW YORK l
JAMES A.
FITZPATRICK NUCLEAR POWER PLANT l
DOCKET NO. 50-333 i
i l
l I
1 l
i l
l l
Section I - Description of Modification The surveillance requirement of Environmental Technical Specification, Section 2.3.B.10 (page 13) regarding off-gas system isolation feature is changed to require testing at least once per operating cycle from the previous annual test.
Section II - Purpose of the Modification The purpose of this modification is to resolve an existing conflict between the Environmental Technical Specifications (Appendix B) and the operating Technical Specifications (Appendix A).
A test frequency of once each operating cycle is consistent with the testing frequency for similar systems listed in Table 4.2-4 of the operating Technical Specifications.
Section III - Impact of the Change This change will not in; pact operations at JAF since this test is already conducted in accordance with operating Technical Specifications.
Section IV - Implementation of the Modification The changes as proposed will not impact the ALARA or Fire Pro-tection programs at JAF.
Section V - Conclusion The incorporation of these modifications:
a) will not increase the probability nor the consequences of an accident or mal-function of equipment important to safety as previously evalu-ated in the Safety Analysis Report; b) will not increase the possibility for an accident or malfunction of a different type than any evaluated previously in the Safety Analysis Report; c) will not reduce the margin of safety as defined in the basis for any Technical Specification; and d) does not constitute an unrevi ewed safety question.
Section VI - Referenes (a)
JAF FSAR (b)
JAF SER