ML20032A521

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept Re Incorrect Analysis Used for Design of Containment Spray Sys Pipe Supports within Containment, Initially Reported 810918.Supports Reviewed.Two Anchors & Spring Supports Require Structural Mod
ML20032A521
Person / Time
Site: Diablo Canyon  
Issue date: 10/19/1981
From: Crane P, Crone P
PACIFIC GAS & ELECTRIC CO.
To: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8110300290
Download: ML20032A521 (2)


Text

o,p*

Dock'et Nos. 50-277/323 f -..

.r 50 55(e) Report PAC I P'I C GAS AND E IaE C T R,I C C O M PANY 77 BE ALE STREET, SIST FLOOR, S AN FRANCISCO,3 ALIFORNI A 94106 P. O. BOX 744 2 pg T E LE PH O N E (415) 781 4 211 T E L E C O PI E R (415) 5 4 3-7813 ROBERY OHLB ACH

    • 3.jy*j,, a,*;aes.

E neago J., me w

4.

y *f.f..*,{s*.{.8,*gg*,

,8j ;*"*,*,',,,.De ass.,4 vtCE Pptst;E%T A40 GEMEP AL ATTO#NEY n......n.....a..

C H A RLES T. VAN O E US E N

f.'*[,*g,"'((:.** '
  • $ *,1*d.'.%"[t',..,

PHILIP A. CR AN E, dR,

$ N.Io.fg$$*d.

j o. ' [ r "."** *'""

ho".N,E UIs'I v Iv'o"eY.".'w E.*

HEN PY J. LaPL ANTE

- e U [n.wam E [ vom

  • "[*'"^^""

JOHN 8.G1BSON A RTHV R L. MILL M A N. d R.

CH A R L E $ W. TH1SS E LL

$'g;II,""l**l["

'[,',"7,*,#f,*(([,",'

DAN 1E L E. O185O N It'.".:$7:Ik**

E*."."^.$",7lN'"

,=::':=:~
a':::.:.

a Ae H e. PA uu9 N, s.

%..."..!.:M.. h..~..

W:

      • c"."'."c".'

?.E!.:.?F=."..

,.... ~..

?:::::r,n::~-~
a::-~~~
~.~.=: =,

" ' ' * * ~ ' "

October ~ 19, 1981 cs g-c2 Mr. R. H. Engelken, Director

.n Q

g Office of Inspection and Enforcemerit po g

Sh Region V OCTg g ygON,

y o

U. S. Nuclear Regulatory Commission

.c o

1450 Maria Lane, Suite 210 y',Y$hin.u 7 q"

Walnut Creek, CA 94596 t

.@/

9 vp en M N, Re: Docket 50-275 Docket 50-323 Diablo Canyon Units 1 and 2

Dear Mr. Engelken:

On September 18, 1981, Mr. John Burdoin was notified by tele-phone of a deficiency reportable under 10 CFR 50.55(e). The report addressed recently discovered deficiencies in the design of the contain-ment spray system pipe supports located within containment.

The following deficiencies were identified:

1.

An incorrect thermal analysis was used for hanger Mads.

2.

This analysis was performed with one snubber modeled as a rigid member.

3.

The variable spring settings for the pipe sy, ports were improperly set based on a deadload analysis which assumed, incorrectly, that the pipes contained water.

g6N I

4.

In designing a pipe anchor, the loads from only one side were used.

/ 6 8110300290 811019' PDR ADOCK 05000275 S

PDR

_o n.

c:

i Mr.-R.-:H.-Engelken October,19, 1981-New analyses were performed. addressing all of the above items.

. All supports were reviewed,-qualified, or~ redesigned:as' dictated by.the corrected support loads. As;a result, two anchors require structursi-modification and the spring supports'for those two anchors require minor l changes. These changes will be' completed prior to power: ascension.

We reported these deficiencies on.the assumption 1that an impact' on' safety existed. -Since the design has been modified, we deemed it unnecessary to make the extensive reanalysis required to_ determine if tie systems-would have remained operational had these deficiencies-remainedLundetected.

This is'the final report on the subject.

I N

Very.truly yours,

!s e

I cc: Director 1

Office of-Inspection and Enforcement

(

U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Service List i

s i

O Y

_