l TENNESSEE VALLEY AUTHORITY CH ATTANOOG A. TENN ESSEE 37401 400 Chestnut Street Tower II

\\-

October 14, 1981

\\f BLRD-50-438/81-58 lS

,. OCT3>

\\ [ 1,,co w E $ ^ % g//

Mr. James P. O'Reilly, Director u,:

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission

'g N

Region II - Suite 3100

'GNIJTS 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNIT 1 - DEFICI'ENT WELDS ON PENETRATIONS SUPPLIED BY SARGENT - BLRD-50-438/81 FIRST INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector R. V. Crlenjak on September 14, 1981 in accordance with 10 CFR 50.55(e) as NCR 1584. Enclosed is our first interim report. We expect to submit our next report by December 17, 1981. We consider 10 CFR Part 21 applicable to this deficiency.

If you have any questions concerning this matter, please get in touch with R. H. Shell at FTS 857-2581.

Very truly yours, TENNES5?E VALLEY AUTHORITY Q, l'qt4

.Y L. M. hills', Manager Nuclear Regulation and Safety Enclosure cc:

Mr. Victor Stello, Jr., Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 t

'h 9

6 t\\\\

8110220454 811904 PDRADOCK05000g S

An Equal Opportunitv Employer

e ENCLOSURE r

BELLEFONTE NUCLEAR PLANT UNIT 1 DEFICIENT WELDS ON PENETRATIONS SUPPLIED BY SARGENT BLRD-50-438/81-58 10 CFR 50.55(e)

FIRST INTERIM REPORT l

Description of Deficiency A routine inspection by Mechanical / Welding Group inspectors after installation of emergency sump suction lines 1A and 1B, supplied by Sargent i

Industries, El Segundo, California, revealed insufficient filler metal deposits on two weldolets on line 1 A (penetration S23) and one weldolet on line 1B (penetration 322).

Interim Progress TVA is still in the process of evaluating the' subject deficiency. A detailed report of this evaluation will be provided upon completion of the evaluation.

4 i

l' I

I 1

't w.e=.

g 1

1

~..

.. - -.