Text
.
, g>2 Kf cgj gi
),
UNITED STATES g
',g NUCLEAR REGULATORY COMMISSION y
OE WASHINGTON, D. C. 20555 5
'+4 *... 4 DUQUESNE LIGHT COMPANY OHIO EDISON COMPANY
,4 PENNSYLVANIA POWER COMPANY DOCKET NO. 50-334 BEAVER VALLEY POWER STATI0ft, UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 45 License No. DPR-66 j
1.
The Nuclear Regulatory Commission (the Commission) has fcund that:
A.
The application for amendment by Duquesne Light Company, Ohio Edison Company, and Pennsylvania Power Company (the licensees) dated September 16, 1981, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; 1
C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations.
D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have 9een satisfied.
i i
t l
8110130019 810922 I
PDR ADOCK 05000334 wP.
. 2.
Accordingly, the lice'nse is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-66 is hereby amended to read as follows:
(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 45, are hereby incorporated-in the license. The licensee shall operate the facility in accordance with the Technical Specific'itions.
3.
This license amendment is effective as of the date of its issuance.
FOR THE NUCLE R REGULATORY COMMISSION
')
3
'. &th M b0 StevenA.Yarg.a, Chief
\\
Operating Reactors Bran h No.1 Division of Licensing,
Attachment:
Changes to the Technical Specifications Date of Issuance: September 22, 1981 e
t 4
~
ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 45 TO FACILITY OPERATING LICENSE NO. DPR-66 da
. DOCKET NO. 50-334 Revise Appendix A as follows:
Remove Pages Insert Pages 3/4 3-52 3/4 3-52 3/4 4-31 3/4 4-31 4
i 4
e h
e k
~. - -
.E
~
E9 TABLE 4.3-7 h
ACCIDENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS
=<
CilANNEL CHANNEL E'
INSTRUMENT CHECK CALIBRATION 1.
Pressurizer Water 1.evel M
R U) 2 Auxiliary Feedwater Flow Rate S/U R
3.
Reactor Coolant Syste,m Subcooling Margin Monitor M
R 4.
PORY Accoustical Detector Position Indicator M
R 5.
PORV Limit Switch Position Indicator M
R 6.
PORV Block Valve Limit Switch Position Indicator M
R 7.
Safety Valve Accoustical Detector Position Indicator M
R 8.
Safety Valve Temperature Detector Post tion Indicator M
R k
9, PORV Control Pressure Channels (PT-RC-444, 445)
P1 R(2) l hg (1) Channel check to be performed in conjunction with Surveillance Requirement 4.7.1.2.a.9 following an extended plant outage.
[
(2)
The complete channel calibration as defined in 1.9 will be deferred until startup following g
the cycle 2 refueling.
8 f
~
REACTOR COOLANT SYSTEM 3/4 4.11 RELIEF VALVES LIMITING CONDITION FOR OPERATION 3.4.11
( Two ) power operated relief' valves (PORVs) and their associated block valves shall be OPERABLE.
APPLICABILITY:
MODES 1, 2 and 3.
ACTION:
a.
Withless than 2 PORV(s) operable, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> either restore two PORV(s) to OPERABLE status or close the associated block valve (s) and remove power. from the block valve (s); otherwise, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
b.
With one or more block valve (s) inoperable, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> either restore the block valve (s) to OPERABLE status or close the block valves (s) and remove power from the block valve (s); otherwise, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUT-DOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
6
(
SURVEILLANCE REQUIREMENTS 4.4.11.1 Each PORV shall be demonstrated OPERABLE:
a.
At least once per 31 days by perfonnance of a CHANNEL CHECK of tne position indication, excluding valve operation and b.
By performance of a CHANNEL CALIBRATION in accordance with Table 4.3-7 or. the operable PORV(s) Control Channel (s).
4.4.11.2 Each block valve shall be demonstrated OPERABLE at least once per 92 days by operating the valve through one complete cycle of full travel.
4.4.11.3 The emergency power supply for the PORVs and block valves shall be demonstrated OPERABLE at least once per 18 months by operating the valves through a complete cycle of full travel.
t BEAVER VALLEY - UNIT 1 3/4 4-31 Amendment No.M 45 5