NMne NIAGARA MOHAWK POWER CORPORATION /300 ERIE BOULEVARD WEST, SYRACUSE, N.Y.13202/ TELEPHONE (315) 474-1511 July 24,1981 i
Office of Inspection and Enforcenent A
Region I 4) p%
Attention: fir. Elden J. Brunner, Acting Director Q g jd Division of Resident and Project Inspection iI.
B E
U.S. !!uclear Regulatory Connission liUG05198tm $
631 Park Avenue Q u,.,,aum %. ?
?-
King of Prussia, PA 19406
'g
- = cn
Dear fir. Brunner:
Re: fline Mile Point Unit 2 Docket flo. 50-410 On June 17, 1980 the Region I Office of Inspection and Enforcement was notified of a 50.55(e) deficiency. This involved Rosemont Model tio.1152 pressure transmitters which provided ambiguous outputs at pressures over or under the specified pressure range. This condition had previously been reported to the Region V Office of Inspection and Enforcement by our nuclear stean syston supplier, General Electric, per the requirements of 10 CFR Part 21.
Although a review of our files has indicated that we anparently did not submit a formal 30 day report; nevertheless fliagara Mohawk has provided information on this subject in our response to IE Bulletin 80-16, which is attached.
As indicated in the attached response to IE aulletin 80-16, additional information cannot be provided until December 31, 1981, as we are avaiting further action by our nuclear steam systen supplier.
Very truly yours, ilIAGARA 110H WK POWEP' RPORATI0tl
+
ierald K.
de Vice President System Project Management PEF:bd xc: Director Inspection and Enforcement U.S. !!uclear Regulatory Connission Washington, D.C.
20555 C.G. Lewis, Project fianager (M/C 394)
Fr{
!!ine Mile Point 2 g
General Electric - flEG I
175 Curtner Avenue gl g
San.inse, CA 95125 8108060098 810724 PDR ADOCK 05000410 m
I gao %IoTo60tTC Y NIAGARA 9~
UMOHAWK NIAGARA MOHAWK POWER CORPORATION /300 ERIE BOULEVA3D WEST, GYRACUSE. N Y.13202/ TELEPHONE (315) 474-1511 April 7,1981 Office of Inspection and Enforcement Region I Attention:
Mr. 8. H. Grier, Director U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406
Dear Mr. Grier:
Re: Nine Mile Point Unit 2 Docket No. 50-410 Your June 27, 1980 I. E. Bulletin No. 80-16 requested information p
regarding the potential misapplication of Rosemount, Inc. Model 1151 and 1152 pressure transmitters in safety related application at Nine Mile Point Unit 2.
A preliminary review has identified the potential applications and locations of the suspect parts in safety related systems at Unit 2, as indicated in Table 1 attached.
As indicated in the attached table, the recommended fix is to replace "A" or "D" output boards with "E" output boards.
The panels identified in the attached table will be ins acted to detemine which output boards have been installed. The results of this inspection and the corrective action taken will be reported to you by December 31, 1981.
Very truly yours, NIAGARA M0 HAWK PpWER CORPORATION f
./
/
'Ge' % *R.. W L
rald K.
de Vice Preside t System Project Mar:gement PEF:ja xc: Office of Inspection and Enforcement Division of Reactor Construction Inspection U. S. Nuclear Regulatory Commission Washington, D. C. 20555
NIAGARA M0 HAWK POWER CORPORATION i
NINE MILE POINT UNIT 2 DOCKET NO. 50-410 TABLE 1 RESPONSE TO I.E. BULLETIN 80-16 POTENTIAL MISAPPLICATION OF ROSEMOUNT PRESSURE TRANSMITTERS System No.
Type of (Name)
Panel Location Output Board Fix B22-H067 (Nuclear Boiler)
P004, 5, 26, 27 A or E Note 1 C12 'iO54 (CRD Hydra:.lic) local D or E Note 1 C72-N050 (Reactor Protection)
P004, 5, 26, 27 A or E Note 1 E12-N055, 56 (RHR)
P018, 21 A or E Note 1 E12-N060 (RHR)
P004,18 A or E Note 1 E21-N052, 53 (LPCS)
P001, 19 A or E Note 1 E22-N050 (HPCS)
P024 A or E Note 1 E22-N057 (HPCS)
P024 D or E Note 1 E31-N083, 84, 85 (Leak P017, 29 0 or E Note 1 Detection)
E51-N051 (RCIC)
P017 D or E Note 1 E51-N053 (RCIC)
P017 D or E Note 1 E51-N055 (RCIC)
P017, 29 D or E Note 1 Note 1 An inspection will be needed to detcrmine wh!ch boards (A, D or E) have been installed.
If A or D boards are installed, the correction is to install E boards.