ML20029E493
| ML20029E493 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 06/30/1992 |
| From: | GENERAL PUBLIC UTILITIES CORP. |
| To: | |
| Shared Package | |
| ML20029E489 | List: |
| References | |
| NUDOCS 9405180397 | |
| Download: ML20029E493 (2) | |
Text
_
OYSTER CREEK NUCLEAR GENERATING STATION GASEOUS EFFLUENT ELEVATED RELEASES Second Quarter 1992 FISSION GASES QUANTITY (ci )
KR85M 2.80E+01 KR87 1.57E+01 KR88 1.68E+01 XE133 1.82E+01 XE135 1.87E+01 Total Fission Gases Released: 9.75E+01 ci Gamma EBar:
0.5664 mov Average Rate of Release:
1.24E+01 uCi/sec IODINES
. QUANTITY (ci )
1131 9.16E-03 I132 4.39E-02 I133 3.92E-02 1134 6.71E-02 1135 6.49E-02 Total Iodines Released:
2.24E-01 ci Average Rate of Release:
2.85E-02 uCi/sec PARTICULATES QUANTITY (ci )
CR51 4.25E-03 MN54 2.14E-04 C058 1.35E-04 CO60 4.08E-04 SR89 1.10E-03 SR90 9.79E-06 BA140 6.43E-03 CE141 5.49E-05 GROSSA 2.67E-06 Total Particulates Released:
1.26E-02 ci Average Rate of Release:
1.62E-03 uCi/sec RADIONUCLIDE QUANTITY (ci )
H3 2.26E+00 Avg. Rate of Release for H3:
2.87E-01 uCi/sec Quantity of noble gases derived from gross activity.
9405180397 940511 PDR ADOCK 05000219 R
OYSTER CREEK NUCLEAR GENERATING STATION GASEOUS EFFLUENT GROUND-LEVEL RELEASES j
Second Quarter 1992 FISSION GASES QUANTITY (ci )
KR85M 9.71E-03 KR87 3.66E-02 KR88 5.42E-02 XE133 5.39E-03 XE135 7.31E-02 Total Fission Gases Released: 1.79E-01 ci Average Rate of Release:
2.28E-02 uCi/sec IODINES QUANTITY (ci )
I131 3.17E-05 1132 2.41E-04 1133 3.83E-04 I135 2.22E-04 Total Iodines Released:
8.78E-04 ci Average Rate of Release:
1.12E-04 uCi/sec PARTICULATES QUANTITY (ci )
CR51 3.53E-06 MN54 6.18E-06 C057 6.58E-07 CO60 2.27E-06 SR89 2.71E-05 CS137 8.89E-07 BA140 4.34E-06 Total Particulates Released:
4.50E-05 ci Average Rate of Release:
5.741-06 uCi/sec RADIONUCLIDE QUANTITY (ci )
11 3 0.00E+00 Avg. Rate of Release for H3:
0.00E+00 uCi/sec Quantity of noble gases derived from gross activity.