ML20029E492
| ML20029E492 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 03/31/1992 |
| From: | GENERAL PUBLIC UTILITIES CORP. |
| To: | |
| Shared Package | |
| ML20029E489 | List: |
| References | |
| NUDOCS 9405180396 | |
| Download: ML20029E492 (2) | |
Text
e j
OYSTER CREEK NUCLEAR GENERATING STATION GASEOUS EFFLUENT ELEVATED RELEASES First Quarter 1992 FISSION GASES QUANTITY (ci )
KR85M 6.02E+00 KR87 2.27E+01 KR88 3.36E+01 XE135 4.53E+01 Total Fission Gases Released: 1.08E+02 ci 1
Gamma EBar:
0.8907 mov Average Rate of Release:
1.37E+01 uCi/sec IODINES QUANTITY (ci )
I131 2.42E-02 I132 4.55E-03 I133 1.45E-02 1134 5.95E-03 I135 3.87E-03 i
Total Iodines Released:
5.28E-02 ci Average Rate of Release:
6.71E-03 uCi/sec PARTICULATES QUANTITY (ci )
MN54 1.36E-05 SR89 5.19E-04 SR90 1.73E-06 CS137 7.33E-06 BA140 3.50E-04 GROSSA 3.19E-06 Total Particulates Released:
8.92E-04 ci Average Rate of Release:
1.13E-04 uCi/sec RADIONUCLIDE QUANTITY (ci )
H3 2.84E+00 Avg. Rate of Release for H3:
3.65E-01 uCi/sec i'
Quantity of noble gases derived from gross activity.
1 9405180396 940511 PDR ADDCK 05000219 R
PDR i
OYSTER CREEK NUCLEAR GENERATING STATION l
GASEOUS EFFLUENT GROUND-LEVEL RELEASES First Quarter 1992 FISSION GASES QUANTITY (ci )
KR85M 3.70E-04 KR87 1.39E-03 KR88 2.07E-03 XE133 2.05E-04 XE135 2.79E-03 c
Total Fission Gasts Released: 6.82E-03 ci Average Rate of Release:
8.67E-04 uCi/sec IODINES QUANTITY (ci )
I131 1.66E-05 I133 1.73E-04 Total Iodines Released:
1.90E-04 ci Average Rate of Release:
2.42E-05 uCi/sec PARTICULATES QUANTITY (ci )
CE141 7.09E-07 Total Particulates Released:
7.09E-07 ci Average Rate of Release:
9.01E-08 uCi/sec RADIONUCLIDE QUANTITY (ci )
H3 0.00E+00 Avg. Rate of Release for H3:
0.00E+00 uCi/sec Quantity of noble gases derived from gross activity.
,