ML20028G768
| ML20028G768 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 08/23/1990 |
| From: | Collins S NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Trevors G NEBRASKA PUBLIC POWER DISTRICT |
| Shared Package | |
| ML20028G769 | List: |
| References | |
| NUDOCS 9009040080 | |
| Download: ML20028G768 (3) | |
See also: IR 05000298/1990025
Text
r
o
.o
,
AUG 2 31990
-
.
In Reply Refer To:
Docket: 50-298/90-25
Nebraska Public Power District
ATTN: George A. Trevors, Senior Staff
'
Advisor - Nuclear Power Group
P.O. Box 499
'
-
Columbus, Nebraska 68602-0499
Gentlemen:
This refers to the team inspection conducted by Messrs. N. Terc, K. Kennedy,
and R. Bennett of this office during the period July 23-27, 1990, of activities
authorized by NRC Operating License DPR-46 for Cooper Nuclear Station, and to
the discussion of our findings with you and other representatives of the
Nebraska Public Power District at the conclusion of the inspection.
Areas examined during the inspection included the implementation of the
emergency plan and procedures during the annual emergency response exercise.
Within these areas, the inspection consisted of selective examination of
procedures and representative records, interviews with personnel, and
observations by the inspection team. The inspection findings are documented in
the enclosed inspection report.
Within the scope of the inspection, no violations or deviations were
identified.
Your staff's overall performance during the 1990 exercise was very good.
Improvements from previous exercises were noted.
Your staff's response during
i
the course of the exercise was adequate to protect the health and safety of the
i
public.
'
The inspection identified two exercise weaknesses in your emergency
preparedness program. One weakness pertains to the duties and responsibilities
of the control room director (CRD) who, in addition to his many other duties,
was assigned to maintain continuous accountability after the evacuation of
unessential personnel from the protected area. The other weakness pertains to
a delay in using the emergency diesel generator after it was available.
This
diesel was a critical factor necessary for mitigating the hypothetical
.'
accident.
Exercise weaknesses, according to 10 CFR Part 50, Appendix E.IV.F.5,
are inspection findings that need to be corrected by the licensee. You are
requested to provide this office with a description of your corrective measures
and your schedule for completing these actions within 30 days after receipt of
this letter.
- RIV:SEPS
- C:SEPS
- DRSS
.[ft
-
,
l
NMTere:nh
DAPowers
fA3 Beach
JCo111 /
'
/ /90
/ /90
V T/b/90
%
.O
ih
- Previously Concurred
02091
%
- grugstn8@
o
.l
.
.
.
.
Nebraska Public Power District
-2-
l
,
We have also examined actions you have taken with regard to previously
identified inspection findings. The status of these items is identified in
paragraph 2 of the enclosed report.
Should you have any questions concerning this inspection, we will be pleased to
'
discuss them with you.
,
,
Sincerely,
Original Signed By
'
Samuel J. Collins, Director
Division of Reactor Projects
Enclosure:
Appendix - NRC Inspection Report
50-298/90-25
cc w/ enclosure:
Nebraska Public Power District
ATTN:
G. D. Watson, General Counsel
P.O. Box 499
Columbus, Nebraska 68602-0499
,
Cooper Nuclear Station
ATTN: John M. Meacham, Division
,
Manager, Nuclear Operations
P.O. Box 98
Brownville, Nebraska 68321
Nebraska Department of Environmental
Control
ATTN: Dennis Grams, Director
P.O. Box 98922
Lincoln, Nebraska 68509-8922
L
Nemaha County Board of Commissioners
ATTN:
Larry Bohlken, Chairman
i
Nemaha County Courthouse
1824 N Street
Auburn, Nebraska 68305
l-
l
1
lc
..
.,
I
f...
.
Nebraska Public Power District
-3-
Department of Health
Division of Radiological Health
!
ATTN: Harold Borchart, Director
!
301 Centennial Mall, South
'
P.O. Box 95007
Lincoln, Nebraska 68509-5007
Kansas Radiation Control Program Director
!
U.S. Nuclear Regulatory Commission
ATTN: Senior Resident Inspector
P.O. Box 218
Brownville, Nebraska 68321
U.S. Nuclear Regulatory Commission
' ATTN:
Regional Administrator, Region IV
611 Ryan Plaza Drive, Suite 1000
Arlington, Texas 76011
Program Manager
FEMA Region 7
'
911 Walnut Street,' Room 200
'
Director
Nebraska Civil Defense Agency
1300 Military Road
Lincoln, Nebraska 68508
bec to DMB (IE35)
bec distrib. by RIV:
- R. D. Martin
- Resident Inspector
- SectionChief(DRP/C)
Lisa Shea, RM/ALF
- DRSS-FRPS
- MIS System
- RIV File
- Project Engineer (DRP/C)
- RSTS Operator
- DRP
P. O'Connor, NRR Project Manager (MS:
11-D-23)
- ABBeach
- DAPowers
- NMTerc
- SEPS Files
- w/766
.
. . , . _ .