Text
-_
DUKE POWEn GOMPANY <
l'.O. IM)X 33180 CliAHLUTTE, N.C. 28242 II AI. II. T1*CKER TELEPflONE via a,arassen (704) 3?J~4S!Il September 14, 1982
.u,....
um.
Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuc1 car Regulatory Commission Washington, D. C. 20553 Attention:
Ms. E. G. Adensam, Chief Licensing Branch No. 4 Re: Catawba Nuclear Station Docket Nos. 50-413 and 50-414
Dear Mr. Denton:
On July 29, 1982, Duke Power Company transmitted comments on the Fire Protectiot.
preliminary draft SER.
Included as Table 1 was a list of rooms and the type of fire detector provided. A number of errors were noted in this table. Attached is a corrected copy.
Very truly yours, f B.f A /fs Hal B. Tucker ROS/php Attachment cc:
Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 Mr. P. K. Van Doorn hTC Resident Inspector Catawba Nuclear Station Q
Mr. Robert Guild, Esq.
Attorney-at-Law 314 Pall Mall Columbia, South Carolina 29201 8209210037 820914 PDR ADOCK 05000413 E
Mr. Harold R. Denton, Director September 14, 1982 Page 2 cc: Palmetto Alliance 2135 Devine Street Columbia, South Carolina 29205 Mr. Jesse L. Riley Carolina Environmental Study Group 854 Henley Place Charlotte, North Carolina 28207 Mr. Henry A. Presler, Chairman Charlotte-Mecklenburg Environmental Coalition 943 Henley Place Cnarlotte, North Carolina 28207 i
Table 1 Room Number Description Detection ELEVATION 522 100 Refueling Water Recirculating Pump; I - R/R Component Cooling Drain Sump & Sump Pumps 101 Corridor I - R/R-102 Containment Spray Pump 1A I - R/R 103 Containment Spray Pump 1B I - R/R 104 Residual Heat Removal Pump 1B
~ I - R/R I - R/R 105 Residual Heat Removal Pump 1A 106 Corridor I - R/R 107 Containment Spray Pump 2A I - R/R 108 Containment Spray Pump 2B I - R/R 109 Residual Heat Removal Pump 2B I - R/R 110 Residual Heat Removal Pump 2A I - R/R-
.111 Corridor I - R/R 112-Corridor I - R/R 113 Pipe Chase ELEVATION 543 200 Area Between Column Lines 56 & 58 I - R/R 200A Stairwell North of East Elevator 200B Area in Front of East Elevatorf 200C Groundwater Drainage Sump & Pumps 200D Stairwell Adjacent to Room 248 201 Area South of Valve Gallery 202 202 Valve Gallery 203 Waste GaF Decay Tanks 204 Hydrogen Recombiner Control Panel Area
- (Corridor) 204A Exhaust Fan Concrete Pad 204B Waste Gas Analysis Rack "A" 205 Waste Gas Hydrogen Recombiner "A" 205A Gas Analysis Rack 206A Waste Gas Hydrogen Recombiner "B"
~
206B Waste Gas Compressor Package "B" 207 Waste Gas Compressor Package "A" 208 Corridor I - R/R 209 Corridor I - R/R 209A Stairwell 210 Corridor Adjacent to Recycle Evap.
Feed Pump 210A Recycle Evap. Feed Pump "A" & "B" 210B Valve Callery 211 Recycle Evap. Package 212 Corridor I - R/R 212A Stairwell 212B Exhaust Fan Concrete Pad
- \\
l
Room Number Description Detection 213 Gas Decay Tank Drain Pump 214 Chemical Drain Tank, Floor Drain Sump, Waste Evap. Feed Sump 215 Access Corridor 215A Waste Drain Tank Pumps 215B Waste Evap. Feed Tank Pumps 215C Waste Drain Tank 215D Waste Evap. Feed Tank 216 Waste Evaporator Package 217 Mechanical Penetration Area - Unit 1 I - R/R 220 Mixing & Settling Tank Pumps 221 Mixing & Settling Tank 222 Spent Resin Valve Body Room 222A Spent Resin Stora8e Tank B 222B Spent Resin Storage Tank A 223 Spent Resin Sluicing Pump & Valve Body Area 224 Laundry & Hot Shower Tank Pump 225 Laundry & Hot Shower Tank / Floor Drain Tank 226 Floor Drain Tank Pump 227 Mechanical Penetration Area - Unit 2 I - R/R 230 Centrifugal Charging Pump 1A I - R/R 231 Centrifugal Charging Pump 1B I - R/R 232 Corridor I - R/R 233 Reciprocal Charging Pump - Unit 1 I - R/R 234 Safety Injection Pump 1B I - R/R 235 Safety Injection Pump 1A I - R/R 236 Hatch Area I - R/R 237 Restricted Instrument Shop I - R/R 238 Sample Panel Area - Unit 1 I - R/R 239 Cable Shaft Access Area I - R/R 240 Centrifugal Cherging Pump 2A I - R/R 241 Centrifugal Charging Pump 2B I - R/R 242 Corridor I - R/R 243 Reciprocal Charging Pump - Unit 2 I - R/R 244 Safety Injection Pump 2B I - R/R 245 Safety Injection Pump 2A I - R/R 246 Hatch Area I - R/R 247 Restricted Instrument Shop I - R/R 248 Sample Room - Unit 2 I - R/R 250 Vent Condensate Drain Tank - Unit 1 I - R/R 250A Stairwell 251 Aux. Feedwater Pump Turbine Panel I - R/R 252 Train A Shutdown Panel I - R/R 253 Train B Shutdown Panel I - R/R 254 Turbine Driven Aux. Feedwater Pump - 1A Photoelectric 255 Motor Driven Aux. Feedwater Pump - IB I - R/R 256 Motor Driven Aux. Feedwater Pump - 1A I - R/R 260 Vent Condensate Drain Tank - Unit 2 I - R/R 260A Stairwell 261 Aux. Feedwater Pump Turbine Panel I - R/R 262 Train A Shutdown Panel I - R/R Room Number Description Detection 263 Train B Shutdown Panel I - R/R 264 Turbine Driven Aux. Feedwater Pump - 2A Photoelectric 265 Motor Driven Aux. Feedwater Pump - 2B I - R/R 266 Motor Driven Aux. Feedwater Pump - 2A I - R/R ELEVATION 560 300 Equipment Area I - R/R 390A Stairs 300B Elevator Lobby 300C Duct Shaft 300D Duct Shaft 301 Boric Acid Transfer Pumps - Unit 2 302 Boric Acid Transfer Pumps - Unit 1 303 Corridor (Boric Acid Batching Tank)
I - R/R 303A Stairs 303B Duct Shaft 304 Valve Gallery I - R/R 305 Boric Acid Tank "A" 306 Valve Gallery I - R/R 307 Boric Acid Tank "B" 308 Corridor I - R/R 303A Boron lajection Tank & Pumps - Unit 2 I - R/R 309 Volume Control Tank - Unit 2 310 Corridor I - R/R 310A Stairs 310B Duct Shaft 311 Pipe Trench & Hall 312 Pipe Trench & Hall 313 Valve Gallery I - R/R 314 Recycle Holdup Tank "A" 315 Valve Gallery I - R/R 316 Recycle Holdup Tank "B" 317 Valve Gallery 318 Corridor I - R/R 318A Boron Injection Tank & Pumps - Unit 1 I - R/R 319 Volume Control Tank - Unit 1 320 Motor Control Center I - R/R 321 Seal Water Heat Exchanger - Unit 2 322 Cable Tray Access - Unit 2 I - R/R 322A Stairs 323 Pipe Chase I - R/R 323A Pipe Chase 323B Pipe Chase I - R/R 324 Boronometer - Unit 2 330 Motor Control Center I - R/R 331 Seal Water Heat Exchanger - Unit 1 332 Boronometer - Unit 1 333 Pipe Chase I - R/R 333A Pipe Chase l
333B Pipe Chase I - R/R 4
Room Number Description Detection 334 Cable Tray Access - Unit 1 I - R/R 340 Battery Room - Unit 2 I-340A Cable Shaft 340B Cable Shaft 341 Vital Battery 2EBA I - R/R 342 Vital Battery 2 EBB I - R/R 342A Battery Charger 2ECB I-343 Vital Battery 2EBC I - R/R 344 Vital Battery 2EBD I - R/R 345 Aux. Cont. Pwr. Batt. 2CBB I - R/R 346 Aux. Cont. Pwr. Batt. 2CBA I - R/R 350 Battery Room - Unit 1 I-350A Cable Shaft 350B Duct Shaft 351 Vital Battery 1EBA I - R/R 252 Vital Battery 1 EBB I - R/R 352A Battery Charger 1ECB I-353 Vital Battery 1EBC I - R/R 354 Vital Battery 1EBD I - R/R 355 Aux. Cont. Pwr. Batt. ICBB I - R/R 356 Aux. Cont. Pwr. Batt. ICBA I - R/R 360 Electrical Penetration Room - Unit 2 I-360A Stairs 362 Switchgear Room I-363 Switchgear HVAC Equipment Room I-370 Electrical Penetration Room - Unit 1 I-370A Stairs 372 Switchgear Room I-373 Switchgear HVAC Equipment Room I-ELEVATION 577 400 Equipment Area I - R/R 400A Stairs 400B Stairs 400C Duct Shaft 400D Duct Shaft 400E Stairs 400F Duct Shaft 400G Duct Shaft 401 Glycol Mixing & Storage Tank; I - R/R Elevator Lobby 401A Stairs 402 Corridor I - R/R 403 Container & Drum Storage I - R/R 404 Access to Rooms 404A Dewatering Pump I - R/R 404B Radwaste Feed Skid I - R/R 404C Evaporator Concentrate Holdup Tank I - R/R 405 Filter Bunkers I - R/R 407 Corridor I - R/R l Rev. I
Room Number Description Detection 408 Fue! Pool Cooling Demineralizer I - R/R 409 Fuel Fool Cooling; Skimmer Pumps; Heat I - R/R Exchangers 410 Recycle Evaporator Feed Demin (Hatch) 411 Recycle Evaporator Condensate Demin.
(Hatch) 412 Recycle Evaporator Condensate Filter (Double Hatch) 413 Boric Acid Filters (2 Adjacent hatches) 414 Recycle Evaporator Feed Demin (Hatch) 415 Recycle Evaporator Concentrate Filter (Hatch) 416A Recycle Evaporator Feed Filter (Double Hatch) 416B Recycle Evaporator Feed Filter (Double Hatch) 417 Fuel Pool Cooling Demineralizer I - R/R 418 Fuel Pool Cooling Pumps & Heat Exchanger I - R/R 419 Mechanical Penetration Room I - R/R 420 Fuel Pool Cooling Post Filters and Pre-Filters and Fuel Pool Skimmer Filter (6 Hatches) 421 Thermal Regenerative Demineralizer 2B (Hatch) 422 Thermal Regenerative Demineralizer 2C (Hatch) 423 Cation Bed Demineralizer 2A (Hatch) 424 Waste Monitor Tank Demineralizer (Hatch) 425 Containment Spray & Residual Heat Removal I - R/R Heat Exchangers - 2A 426 Containment Spray & Residual Heat Removal I - R/R Heat Exchangers - 2B 427 Mechanical Penetration Room I - R/R 428 Laundry / Hot Shower Carbon Filter 430 Fuel Pool Skimmer Filter & Waste Evaporator Condensate Filter (3 Hatches) 431 Thermal Regenerative Demineralizer - IE (Hatch) 432 Thermal Regenerative Demineralizer - IC (Hatch) 433 Cation Bed Demineralizer IA (Hatch) 434 Containment Spray & Residual Heat Removal I - R/R Heat Exchangers - 1A 435 Containment Spray & Residual Heat Removal I - R/R Heat Exchangers - IB 441 Floor Drain Tank Filter 442 Laundry & Hot Shower Filter (Primary and Secondary) 443 Thermal Regenerative Demineralizer - 2A (Hatch) 444 Thermal Regenerative Demineralizer - 2D 445 Mixed Bed Demineralizer (Hatch)
I l
1 Room Number Description Detection 446 Reactor Coolant Filter - 2B (Hatch) 447 Seal Water Return Filter (Hatch) 448 Thermal Regenerative Demineralizer - 2E (Hatch) 449 Mixed Bed Demineralizer - 2A (Hatch) 450 Fuel Pool Cooling Filters - Unit 1 (5 Hatches) 451 Seal Water Return Filter - Unit 1 (2 Hatches) 452 Thermal Regenerative Demineralizer - 1D (Hatch) 453 Thermal Regenerative Demineralizer - IB (Hatch) 454 Mixed Bed Demineralizer - IB (Hatch) 455 Reactor Coolant Filter - IB (2 Hatches) 456 Reactor Coolant Filter - 1A (2 Hatches) 457 Waste Evaporator Condensate Demineralizer (1 Hatch) 458 Thermal Regenerative Demineralizer 1A (1 Hatch) 459 Mixed Bed Demineralizer IA 460 Reactor Coolant Filter 2A 461 Waste Monitor Tank Filter 462 Seal Water Injection Filter 2B 463 Seal Water Injection Filter 2A 464 Spent Resin Sluice Filter 465 Letdown Reheat Heat Exchanger - Unit 2 I - R/R 466 Letdown Chiller Heat Excharger - Unit 2 I - R/R 467 Letdown Heat Exchanger
'Jnit 2 I - R/R l
468 Moderating Heat Exchanger - Unit 2 I - R/R l
469 Motor Control Center I - R/R 470 Seal Water Injection Filter 1A 471 Seal Water Injection Filter IB 472 Waste Evaporator Feed Filter B l
473 Waste Evaporator Feed Filter A 474 Letdown Heat, Exchanger - Unit 1 I - R/R 475 Chiller Heat Exchanger - Unit 1 1 - R/R l
476 Letdown Heat Exchanger - Unit 1 I - R/R 477 Moderating Heat Exchanger - Unit 1 I - R/R 478 Motor Control Center I - R/R 480 Corridor (East of #2 Cable Room 481)
I - R/R 480A Cable Shaft Room I - R/R 481 Cable Room I - R/R 481A Electrical Boards I - R/R 482 Duct Shaft (East of #2 Corridor & Cable l
Room) 483 Corridor 484 Electrical Penetration Room - Unit 2 I-484A Stairs - Entry to Electrical Penetration Room 485 Switchgear Equipment Room I-486 Load Center - Unit 2 I-Rev. I
{
Room Number Description Detection 490 Corridor I - R/R 490A Cable Shaft I - R/R 491 Cable Room - Unit 1 I - R/R 491A Electrical Boards Room - Unit 1 I - R/R 492 Duct Shaft (Adjacent to #1 Corridor) 493 Corridor Unit 1 494 Electrical Penetration Room - Unit 1 I-494A Stairs & Access to Electrical Penetration Room 495 Switchgear Equipment Room - Unit 1 I-496 Load Center - Unit 1 I-ELEVATION 594 500 Central Area - Auxiliary Building I - R/R 500A NE Stairwell 500B NW Stairwell 500C SE Stairwell 500D SW Stairwell 510 Counting Room 511 Environmental Room I - R/R 512 H. P. Respiratory I - R/R 530 New Fuel Storage Area, Unit 1 UV 531 New Fuel Receiving Area, Unit 1 UV 540 New Fuel Storage, Unit 2 UV 541 New Fuel Receiving, Unit 2 UV 550 Manway to Spent Resin Batching Tank I - R/R 551 Instrument Calibration 551A Corridor 560 Equipment Area (Vent.)
I-561 Corridor / Hatch Area 561A Stairwell 561B
- Stairwel, 562 Unit 2 Penetration Area (Steam Doghouse) 563 Electrical Penetration, Unit 2 I-564 RMC Room I-570 Equipment Area (Vent.)
I-571 Corridor 571A Stairwell 572 Unit 1 Steam Penetration (Doghouse) 573 Control Room I - R/R 574 Operators Room I-575 Interface Office I-576 Electrical Penetration Room, Unit 1 I-580 N, Accum. Tank Blowoff, Unit 2 580A Stairwell 581 Steam Penetration, Unit 2 (Outside Doghouse) 590 N, Accum. Tank Blowoff, Unit 1 590A Stairwell i-591 Steam Penetration, Unit 1 (Outside Doughouse) i Rev. 1 4
.p,
,._y__e.
,,,._,-y_,-
Room Number Description Detection ELEVATION 609 600 Fuel Pool Operating Floor, Unit 1 I - R/R 600A Duct Room 601 Reactor Personnel Lock Area 601A Reactor Personnel Area I - R/R 602 Decontamination Storage, Unit 1 I - R/R 614 Fuel Pool Operating Floor - Unit 2 I - R/R 614A Duct Room 615 Reactor Personnel Lock Area #2 615A Reactor Personnel Area I - R/R 616 Decontamination Storage, Unit 2 I - R/R ELEVATION 611 750 Purge Supply Room - Unit 1 751 Purge Supply Room - Unit 2 ELEVATION 623 + 10 801 Fuel Pool Purge Unit (Unit 1)
~
802 Fuel Pool Purge Unit (Unit 2)
Room Number Description Detection DIESEL GENERATOR BUILDING 302 Diesel Generator 1A
- R/R 302C Diesel Generator 1A Sequencer Panels I - R/R 304 Diesel Generator IB
- R/R 304C.
Diesel Generator IB Sequencer Panels I - R/R 306 Diesel Generator 2A
- R/R 306C Diesel Generator 2A Sequencer Panels I - R/R 308 Diesel Generator 2B
- R/R 308C Diesel Generator 2B Sequencer Panels I - R/R NUCLEAR SERVICE WATER PJMP STRUCTURE 662 NSWP 1A & 2A I - R/R 663 NSWP IB & 2B I - R/R REACTOR BUILDING Annulus - Unit 1 I-Annulus - Unit 2 I-Pipe Corridor - Unit 1 I-Pipe Corridor - Unit 2 I-Safety Related Cable Trays - Unit 1 I-Safety Related Cable Trays - Unit 2 I-RCP 1A, IB, IC, ID Heat Sensitive Cab.
RCP 2A, 2B, 2C, 2D Heat Sensitive Cab.
Lower Containment Filters IA, 1B I - R/R Lower Containment Filters 2A, 2B I - R/R l
I 1
1
- Rev. 1 i
-