f']^ / Braid:<ood Nuclear Power station Commonw^cith Edison

  • (

. \\,V] Route #1, Box 84 v

Braceville. Illinois 60407 Telephone 815/458-2801 9

October 6,1994 BW/94-0160 Director Office of Resource Management U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention: Document Control Desk

Dear Sir:

Enclosed for your information is the Monthly Performance Report covering Braidwood Nuclear Generating Station for the period September 1 through September 30,1994.

/ (9. - -p-K. L. Kofron Station Manager Braidwood Nuclear Station KLK/CEP/dla Attachments cc:

J. B. Martin, U.S.N.R.C., Region lll R. R. Assa, U.S.N.R.C.

l.D.N.S.

U.S.N.R.C. Resident inspector, Braidwood INPO Records Center D. L. Farrar, Nuclear Regional Service Mgr.

D. M. Saccomando, Nuclear Licensing Admin.

D. R. Eggett, Nuclear Engineering Dept.

K. L. Kaup, Site Vice President, Braidwood NFS, PWR Plant Support P. L. Habel, Unit 1 Operating Engineer J. P. Kuchenbecker, Unit 2 Operating Engineer Nuclear Group, Systems Engineering, Bwd l.D.N.S. Resident inspector, Braidwood J. M. Bunecicky, Westinghouse D. R. Seavers, A.N.I.

'J, j

s.

941o17o119 940930 g

PDR ADOCK 0500o456 R

PDR

BRAIDWOOD NUCLEAR POWER STATION UNIT 1 AND UNIT 2 MONTHLY PERFORMANCE REPORT Com Ed NRC DOCKET NO. 050-456, LICENSE NO. NPF - 72 NRC DOCKET NO. 050-457, LICENSE NO. NPF - 77

A. OPERATING DATA REPORT Docket No: 50 - 456 Unit: Braldwood 1 Date: 10/10/1994 Completed by: Chris Pershey Telephone: 815-458-2801 OPERATING STATUS

1) Reporting Period: September 1994 Gross Hours: Z20
2) Currently Authorized Power Level (MWt):

3411 Design Electrical Rating (MWe-gross):

1175 Design Electrical Rating (MWe-net):

1120 Max Dependable Capacity (MWe-gross):

1175 Max Dependable Capacity (MWe-not):

1120

3) Power level to which restricted (If Any):

None

4) Reasons for restrictions (if Any):

None This Mo, Yr to Date Cumulative

5) Report Period Hours:

720.0 6,551.0 54,104.0

6) Hours Reactor Critical:

720.0 4,791.6 42,389.8

7) RX Reserve Shutdown Hours:

.0

.0

.0

8) Hours Generator on Line:

720.0 4,731.8 41,756.8

9) Unit Reserve Shutdown Hours:

.0

.0

.0

10) Gross Thermal Energy (MWHt):

2,385,155.4 15,028,436.2 130,354,118.6

11) Gross Elect. Energy (MWH):

828,343.0 5,175,716.0 43,990,303.0

12) Net Elect. Energy (MWH):

798,327.0 4,962,309.0 42,105,126.0

13) Reactor Service Factor:

100.0 73.1 78.3

14) Reactor Availability Factor:

100.0 73.1 78.3

15) Unit Service Factor:

100.0 72.2 77.2

16) Unit Availability Factor:

100.0 72.2 77.2

17) Unit Capacity Factor (MDC NET):

99.0 67.6 69.5

18) Unit Capacity Factor (DER NET):

99.0 67.6 69.5

19) Unit Forced Outage Rate:

0.0 2.6 8.8

20) Unit Forced Outage Hours:

0.0 125.4 4030.5

21) Shutdown Schedule Over Next 6 Months:

2/26/95 22)If Shutdown at End of Reporting Period, Estimated Date of Startup:

l

B. AVERAGE DAILY UNIT NET POWER LEVEL LOG Docket No: 50 - 456 l

Unit: Braidwood 1 Date: 10/10/1994 Completed by: Chris Pershey Telephone: 815-458-2801 MONTH: September 1994 Ray MWe-net Day MWe-n_el 1) 1071 16) 1125 2) 1082 17) 1125

  • 3) 1122
  • 18) 1031 4) 1025 19) 1093 5) 1009 20) 1124
  • 6) 1073 21) 1127
  • 7) 1111 22) 1129
  • 8) 1127
  • 23) 1122*

9) 1126

  • 24) 1131
  • 10) 1124
  • 25) 1121
  • 11) 1103 26) 1128 *

, 12) 1119 27) 1134

  • 13) 1121
  • 28) 1136
  • 14) 1122
  • 29) 1134
  • 15) 1123
  • 30) 1133 *
  • Due to condenser efficiency

~

C.

UNIT SHUTDOWNSIREDUCTIONS Docket No.: 50 - 456 Unit: Braidwood 1 Date: 10/10/1994 Completed by: Chris Pershey Telephone: 815-458-2801 REPORT PERIOD: September 1994 LER Cause & Corrective Action No.

Date Tvoe Hours Reason Method Number System Component to Prevent Recurrence None

SUMMARY

      • Unit 1 entered the month of September 1994 with 100% capability and operated routinely the entire month.

TYPE REASON METHOD SYSTEM & COMPONENT F - Forced A - Equipment Failure Maint or Test 1 - Manual S - Scheduled B - Maint or Test 2 - Manual Scram Exhibit F & Instructions for C - Refueling 3 - Auto Scram Preparation of Data Entry Sheet D - Regulatory Restriction 4 - Continued Licensee Event Report (LER)

E - Operator Training & Licensee Examination 5 - Reduced Load File (NUREG-0161).

F - Administration G - Operator Error H - Other

~

D.

SAFETYlREUEF VALVE OPERATIONS Docket No.: 50 - 456 Unit: Braidwood 1 Date: 10/10/1994-Completed by: Craig ingold Telephone: 815-458-2801 Valves No. & Type Plant Date Actuated Actuation Condition Description of Event None f

A.

OPERATING DATA REPORT Docket No: 50 - 457 Unit: Braidwood 2 Date: 10/10/1994 Completed by: Chris Pershey.

Telephone: 815-458-2801 OPERATING STATUS

1) Reporting Period: September 1994 Gross Hours: Z2Q
2) Currently Authorized Power Level (MWt):

3411 Design Electrical Rating (MWe-gross):

1175 Design Electrical Rating (MWe-net):

1120 Max Dependable Capacity (MWe-gross):

1175 Max Dependable Capacity (MWe-net):

1_1.20

3) Power level to which restricted (if Any):

None

4) Reasons for restrictions (if Any):

None This Mo.

Yr to Date Cumulative

5) Report Period Hours:

720.0 6,551.0 52,186.0

6) Hours Reactor Critical:

720.0 5,240.7 43,554.8

7) RX Reserve Shutdown Hours:

.0

.0

.0

8) Hours Generator on Line:

720.0 5,225.7 43,212.0

9) Unit Reserve Shutdown Hours:

.0

.0

.0

10) Gross Thermal Energy (MWHt):

2,422,475.1 16,259,524.0 133,170,196.1

11) Gross Elect. Energy (MWH):

832,727.0

.5,604,301.0 44,718,124.0

12) Net Elect. Energy (MWH):

803,108.0 5,396,128.0 42,862,711.0

13) Reactor Service Factor:

100.0 80.0 83.5

14) Reactor Availability Factor:

100.0 80.0 83.5

15) Unit Service Factor:

100.0 79.8 82.8

16) Unit Availability Factor:

100.0 79.8 82.8

17) Unit Capacity Factor (MDC NET):

99.6 73.5 73 3

18) Unit Capacity Factor (DER NET):

99.6 73.5 73.3

19) Unit Forced Outage Rate:

0.0 20.2 6.0

20) Unit Forced Outage Hours:

0.0 1325.3 2771.3

21) Shutdown Schedule Over Next 6 Months:

10/8/94

22) If Shutdown at end of Reporting Period, Estimated Date of Startup:

.-u c,

-,,--n n

-w

. ~..

l l

B. AVERAGE DAILY UNIT NET POWER LEVEL LOG Docket No: 50 - 457 Unit: Braidwood 2 Date: 10/10/1994 Completed by: Chris Pershey Telephone: 815-458-2801 MONTH: September 1994 Qay MWe-net Q.ay MWe-net a

1) 1126

  • 16) 1124
  • 2) 1124
  • 17) 1124
  • 3) 1120 18) 1124
  • 4) 903 19) 1122
  • 5) 1119 20)

.1122

  • 6) 1129
  • 21) 1126
  • 7) 1132
  • 22) 1129
  • 8) 1129
  • 23) 1130*

9) 1127

  • 24) 1133
  • 10) 1121
  • 25) 1131
  • 11) 1118 26) 1128
  • 12) 1116 27) 1122 *
  • O-13'y * *, e j $ 22. -

28)'

1103 14) 1123

  • 29) 1102 15) 1123
  • 30) 1096
  • Due to condenser efficiency

O C.

UNIT SHUTDOWNS / REDUCTIONS

+

Docket No.: 50.- 457 Unit: Braidwood 2 Date: 10/10/1994-Completed by: Chris F ershey Telephone: 815-458-2801 REPORT PERIOD: September 1994

- LER 2 Cause & Corrective Action Date Type Hours Reason Method Number System Component to Prevent Recurrence 6

JI>

1 j

SUMMARY

      • Unit 2 entered the month of September 1994 with 100% capability and operated routinely the entire month.

l

(

TYPE REASON METHOD SYSTEM & COMPONENT l

F - Forced A - Equipment Failure Maint or Test 1 - Manual S - Scheduled B - Maint or Test 2 - Manual Scram Exhibit F & Instructions for C - Refueling 3 - Auto Scram Preparation of Data Entry Sheet

[

D - Regulatory Restriction 4 - Continued Ucensee Event Report (LER)

E - Operator Training & Licensee Examination 5 - Reduced Load File (NUREG-0161).

I F - Administration l

G - Operator Error H - Other

~..

D.

SAFETY REUEF VALVE OPERATIONS Docket No.: 50 - 457 Unit: Braidwood 2 Date: 10/10/1994 Comp:eted by: Craig Ingold Telephone: 815-458-2801 Valves No. & Type Plant Date Actuated Actuation Condition Description of Event None