_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _

I O

a

?

N fil"D(D '

gM ; SHOREHAM LR4IT 1 H LIST STONE & HEISTE2 ENGINEE:lING CORPORATIOtt RUN DATE 12/20/82 i

g: JOB t#JIBER 11400 1-50!IT HISCELLANEOUS CATEGORY I EQUIPitENT RUll TIllE 13.22.31

' pg ' LILCO DOCl(ET 50-322 ACTIVE BOP QUALIFICATI0tl LEVEL ( 20 ITEHS)

PAGE 1 UN-HARM EQUIPHENT SPEC DIV.

BLDG AVAIL QU.nl QUAL TYPE SAFE QUAL go' PAJIBER DESCRIPTION HO.

RESP VEtOOR ELEV IHSP REPT HETH FREQ HitG SitTDtl STATUS O i IC41mPT-011 SVC HTR HDR PRESS 404 CD ROSElI0UNT SH YES 127514 DBT 40+

F CS.HS F

88 i 1G41mFE-020DZ-004 OUTLET 440 PO PERIDITIT RH YES POM B) 220

H F/I 3

Op h

OM gc}m. IP41stOV031 SERV HATER DIS 197 PD PRATT SH020 YES D-0034-1 SA/ SAT 33+

P4 CS.HS 11 4

QMM' NM IIP 41stt0V032 SERV HATER HDR IV 197 FD PRATT SH033 YES D-0034-4 SA/ SAT 33+

P2 CS.It3 H

f

. 1P41mHDV035 T BELOH SUPLY IV 197 PD PRATT SH025 YES D-0034-4 SA/ SAT 33+

P2 H

H i

j

' IP41mP-003 SERVICE HATER PLAPS 057 PO BINGHAH-HILL SH021 YES 230429 SA 28 F4 CS.HS H

i

, IP41mPte.-FX1 FD AUX RELAY CABINET 125 CD RELIANCE SH023 YES 99AX400708 SA/ SAT 33+

F CS.IIS H

1P41mS-001 SERVICE HATER STRAINER 081 PO RP ADAHS CO SH024 YES N07503 DA 17 F4

' C$.its F

f 1R24mHCC1110 400 V HOTOR CONT CENTE 115 ED SQUARE D CO SH021 YES 108-1.01L2 tBT 4

F CS.HS H

i j

1R24mHCC1120 480 V HOTOR CONT CENTE 115 ED SQUARE D CO SH021 YES 108-1.01L2 IST 4

F CS ells H

1R43eP-201 FUEL DIL XFER PU 420 PD CRAHE CO YD020 YES HE572 SA 13 F3 CS H

1R43mP-202 FUEL OIL XFER PU 420 PD CRANE CO YD020 YES HE572 SA 13 F3 CS H

1R43 MRV 025 P-202 DISCH 191 CD LOHERGAN PH024 YES 502444 SA 40 P3 F

s 1R43 MRV 024 P-201 DISCH 191 CD LOHERGAH PH024 YES 502444 SA 40 P3 F

1R43mTH-132 FUEL OIL STORAGE 114 PO BUFFALO TAPG(

YD020 YES teHBI-22 SA 14 F3 CS H

IX41mFH-048 SCRHHELL PUtFHSE Sts' 270 PD BUFFALO FORGE SH034 YES 745-11140 SA 24+

F2 CS.HS H

IX41=HU0042 FN-48 OUTDOOR AIR 319 CD P0HERS SH025 YES 44057-1 tBT 21 F2 CS.HS H

j f

1X41stt00043 FN-68 EXHAUST AIR 319 CD P0HERS SH025 YES 44057-1 HST 21 F2 CS.IIS H

{

1X41stt00044 FN-48 RETURN AIR 319 CD P0HERS SH025 YES 44057-1 IET 21' F2 CS.HS II k

CS zCOLD SilUT DORt P : PIPE H0lRITED SBTzSINGLE FREQUCHCY QUALIFICATI0H HILESTONES REVISI0li 5 -DECEl'CER 1932 1

_ DA =0YttAllIC AHALYSIS PC :PRIllARY COHT.

BIAXIAL TESTIrG A mREEVALUATION C0tPLETE j

F =FLOCR HOUNTED PL : PEDESTAL SC =SEC0tDARY C0 tit.

B zREQUEST FOR QUAL OR BID ISSUED tiOT E: itL"CR 1:8 j

HS zHOT STAICBf QP = QUALIFIED BY C zS/H RECCtelEt0ATIO!4 TO LILCO

' TYPE Hil;5* CCLtK"4 IS IBTzHULTI-FREQUEllCY PIPItG AtlALYSIS e zLOCATED ON CONT.

D zQUAL DOC RECEIVED QUAtITITY OF ITEttS.

4 BIAXIAL TESTItG SA zSTATIC ANALYSIS HALL E zHARDHARE HCOIFICATION REQ'D

]

HSTzlIULTI-FREQUENCY SATzSIllGLE FREQUENCY H stiEITHER CS OR 845 F zGUAL DOC APVD & FILED 1

SINGLE AXIAL TESTING SItGLE AXIAL TESTING Z zPASSIVE ITEH G zSQRT PAPER CCIPLETE

]

(SQ2T PAPER HOT H zCor8IES OF DOC TO DISTRIBUTION l

3 REQ'D) 4 l

i i

1 i

s j

  • 8

)

/

SHOREHAM LRtIT I H LIST CTOME & HEBSTE3 EtEINEE2 IRE CORPORATICH Pt24 EATE 12/20/02 JOB t&ABER 11400 I-SORT HISCELLAtlEDUS CATEGORY I EQUIPitENT RUN TIltE 13.22.31 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0H LEVEL E 20 ITEllS)

PAGE 2 HARN EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE SAFE CutL PAABER DESCRIPTION TID.

RESP VEtGOR ELEV INSP REPT HETH FREQ HTitG SHiDH STATUS IX4ImTT006 SCRM. PUDPHSE Tele 319 CD P0HERS SH025 YES 43812-1 DBT 24 F2 H

H CS aCOLD SHUT DOW4 P zPIPE HOUNTED SBTzSINGLE FREQUENCY QUALIFICATION HILESTONES REVISIGH 5 -CECEICER 1982 DA DYt4AHIC ANALYSIS PC =PRIllARY CONT.

BIAXIAL TESTIts A = REEVALUATION CotFLETE

~

F zFLOOR HOUNTED PL PEDESTAL SC zSEcotmARY CONT.

B = REQUEST FOR QUAL OR BIO ISSUED tiofEt flu;EER III HS zHOT STA!OBY QP = QUALIFIED BY C sS/H REcolt!EtSATION TO LILCO

' TYPE IITt:S' CClutM IS IBisHULTI-FREQUENCY PIPItG AtlALYSIS e ELOCATED OH COHT.

D = QUAL DOC RECEIVED QUAtlTITY OF ITE!!S.

BIAXIAL TESTItG SA zSTATIC ANALYSIS HALL E zHAR0 HARE HODIFICATION REQ'D HSTalRA.TI-FREQUEriCY SAT =SItKILE FREQUENCY H sitEITHER CS OR HS F zQUAL DOC APVO & FILED SIllCLE AXIAL TESTIts SIflGLE AXIAL TESTING Z zPASSIVE ITEM G aSQRT PAPER COIPLETE ISQRT PAPER HOT H zCOPIES OF DOC TO DISTRIBUTICH REQ'D)

_.y.

O SHOREHAM LMIT 1 RS LIST STON & HEOSTE3 ENGINEESING CORPORATION RUN DATE 12/20/C2 JOB ltABER 11400 1-50RT REACTOR BUILDING CATEGORY I FLOOR-HOUNTED EQUIPMENT RtJH TIltE 13.19.20 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (205 ITEtts)

PAGE 1 r

j HARM EQUIPHENT SPEC DIV.

BLOG AVAIL QUAL QUAL TYPE SAFE Ct!?L HUteER DESCRIPTION HD.

RESP VEf90R ELEV INSP REPT HETH FREQ HTIG T44ICt4 S TM US 1521mPT 153 RV092 H0HITOR 404 CD ROSEHOLMT SC040 YES 127514 leT 40+

F11 CS.HS H i

1521e4EN001 MS SRV QNCHR$

447 PD SARGENT PC006 YES R-S-10078000 DA 9

F11 CS ltS F i

1821eRV 893 VAC RELIEF VALVES 175 PD Ate. GRf06 PC YES TR-77-18 SAT 18 F12 H

B J

1 1821mTE 147 HST PA STEAM LN DET 404 CD ROSEHOLMT SC078 YES 2747 SAT 40+

F2 CS.HS H 3C41mLT 024

$UPP POOL 404 CD ROSEHOLMT SC008 YES 127514 DST 40+

F CS.HS H j

3C41mPT 012 DRYMELL PRESS 404 CD ROSEHOLMT SC094 YES 127514 DST 40+

F CS.HS H 2C41 APT 104 SAFETY REL VALVE 404 CD ROSEHOLMT SC101 YES 127514 DDT 40+

F CS.HS H 3C41mTE 021 DRYMELL TEtr 404 CD ROSEHOLMT SC150 YES 2747 SAT 40+

F CS.IIS F j

l 1C41mTE O22 SUPP POOL TEtr 404 CD ROSEHOUNT SCO28 YES DET F2 CS.lfS D i

1D11mPM.t'41 woM DH HON 332 PD MIC SC112 YES 45493-1 teT 12 F tt H

l 1021mRE 085 RAD HONITOR 475 CD HAHAM PC074 F2 0

i 1E11aFE 804 RHR HM SERV HATER IM.E 440 CD PERttfTIT SC33 YES 90488) 220-CZC SA 40+ P2 CS.HS F/Z f

IElleDO 140 RHR PLAP HIN FLOM BYPA 440 CD PERttlTIT SC14 YES NHBI 220-C2C SA 40+ P4 CS.HS F/Z IElleRO 154 RHR PLRP DISCH 440 CD PERM' TIT SC16 YES DOHB) 220-CZC SA 40+ P4 CS.HS F/Z i

l IE11mRO 159 STEAN LINE DRAINS 440 CD PERHUTIT SC53 YES 90M8) 220-CZC SA 40+

P H

F/Z f

IE11mRO let VAC BREAHER LINE 440 CD PERtRJTIT SC28

.JS 90MBI 220-CZC SA 40+ P H

F/Z IE11as-114 H2 ANALYZER STRAINER 148 PD LESLIE CO SC112 YES 99H51 287-CZC DA P2 H

F/Z l

1 p

1E11mS-139 STEAH DRM R.O. SIRN 148 PD LESLIE SC40 YES NMB) 287-CZC DA P

H F/Z l

1E21mP-049 LOOP LEVEL PLAPS 235 PD GOLLO Pt#P SC006 YES HE-320 SA.

40+

F2 CS H

i i

1E21mRO 094 CORE SPARY PLAP RECIRC 440 CD PERttJTIT SC101 YES 90MB) 220-CZC SA 40+ P2 CS F/Z I

_1E21mRO 095 CORE SPRAY PLAP RECIRC 440 CD PERttJTIT SC14 YES NHB) 220-CZC SA 40+

P2 CS F/Z i

I l

CS = COLD SHUT DOlM P = PIPE NUNTED SST= SINGLE FREQUENCY QUALIFICATION HILEST0tES REVISION 5 -DECCtGER 1982

^

D : DUCT HatflTED PC :PRIHARY C0 tit.

SIAXIAL TESTItG A mREEVALUAT10ft CotrLETE DA DYHAHIC ANALYSIS PL : PEDESTAL SC zSECOtCARY CONT.

B 3 REQUEST FOR QUAL OR 810 ISSUED HOTE: trJtCT It!

F sFLOOR HOLMTED QP z QUALIFIED BY

/ zLOCATED ON CONT.

C zS/H REC 0t2ttilDATION TO LILCO

' TYPE IIT C ' CC' tart IS HS = HOT STAtCBY PIPIttG ANALYSIS HALL D sQUAL DOC RECEIVED QUAIITITY CF IIII*.S.

I

_tBT:tRJLTI-FREQUENCY

$4 zSTATIC AFIALYSIS M stEITHER CS OR HS E zHARD5 TARE HDDIFICATICH REQ'O BIAXIAL TESTIliG SATzSitiCLE FREQUENCY Z zPASSIVE ITEH F QUAL DOC APVD & FILED j

3 HST=HULTI-FREQUENCY

$1HGLE AXIAL TESTING (SQ2T PAPER HDT G aSQRT PAPER COTLETE 1

SINGLE AXIAL TESTING REQ'Ol H

  • COPIES OF DOC TO DISTRIBUTIDH 4

l i

i 8

4

I SHOREHAN UNIT 1 RB LIST STONE & HEBSTE2 ENGINEE2ING CORPORATION RUN DATE 12/20/C2 JOB tlUtBER 11600 1-SORT REACTOR BUILDING CATEGORY I FLOOR-HOUNTED EQUIPffENT RUN tit!E 13.19.20 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tt LEVEL (205 ITEllSI PAGE 2 ItARN EQUIPHENT SPEC OIV.

BLOG AVAIL QUAL QUAL TYPE SAFE CUAL ttABER DESCRIPTION NO.

RESP VEte0R ELEV IttSP REPT llETH FREQ liit!G S ticti STATUS 1E21mRO 097 CORE SPRAY /RHR LEVEL 5 440 CD PERHUTIT SC12 YES tettB3 220-CZC 54 60+

P2 CS.HS. F/Z IE21mS-057 CORE SPRAY LOOP LVL Y 148 PD LESLIE C0 SC008 YES tottB) 287-CZC DA 40+ P2 CS.HS F/Z IE41mP-050 LOOP LEVEL PUte 235 PD GOULD PLAP SC008 YES HE-320 SA 60+

F CS If IE41mPT 142 TO LLB2 OIL COOLER 404 CD ROSEtt0LRtT SC8 YES 127516 IBT 40+

F CS.IIS H 1E41*RO-001 RUPTURE DISH 340 PD 1.YC:45 IIB /BS&B M18 YES 75t-1 SAT 60+

F tl F/Z 1E41mRD-002 RUPTURE DISH 340 PD LYONS Ite/BSSB SC19 YES t59-1 SAT 40+

F H

F/Z IE41mRO 131 HPCI PLAP HIN FLOH BYP 440 CD PERDEJTIT SC17 YES teHBI 220-CZC SA 60+

P N

F/Z j

1:41mRO 132 ItPCI P DIS TO Cote STO 440 CD PERttJTIT SC18 YES teHB) 220-CZC SA 60+

P tt F/Z 1E41mRO 133 TO BARCHETRIC C0teEttSE 440 CD PERtAITIT SC13 YES 99HB) 220-CZC S4 60+ P I4 F/Z IE41mRO 134 LUBE OIL COOLER DISCH 440 CD PERT 9JTIT SC11 YES I4HB) 220-CZC SA 40+ P I4 F/Z 1E41mRO 135 RUPTURE DISH BLEED OFF 440 CD PERHUTIT SC24 YES 99HB) 220-CZC SA 40+ P H

F/Z 1E41mRO 134A STOP VALVE DRAIN 440 CD PERHUTIT SC14 YES 10118) 220-CZC SA 40+ P N

F/Z IE41mRO 136C CONTROL VALVE DRAIN

  • 440 CD PERtRJTIT SC15 YES ttHBI 220-CZC SA 60+

P H

F/Z 1E41mRO 1360 TURBINE DRAIN 440 CD PERHUTIT SC11 YES fot(B) 220-CZC SA 60+

P N

F/Z i

i 1E41mRO 136E TURBINE DRAIN 440 CD PERHUTIT SC11 YES teHB) 220-CZC SA 60+

P tl F/Z IE41mRO 137 HPCI LEVEL P-50 440 CD PERituTIT SC11 YES tettB) 220-CZC SA 60+

P H

F/Z i

1E41mRO 138 TO BAROHETRIC CoteEtlSO 440 CD PERHUTIT SC9 YES IGMB) 220-CZC SA 60+

P tl F/Z l

1E41mRO 153 RtPTURE DISH BLEED OFF 440 CD PERtRJTIT SC024 YES teHB) 220-CZC SA 60+

P tl F/Z 1

i j

IE41mS-055 Y STR-HPCI LOOP LEVEL 146 PD LESLIE CO SC008 YES teHB) 287-CZC DA 60+

P tl F/Z IE51mFE 099 RCICLOOP LVLaP-051 440 CD PERttJTIT SC13 YES teHB) 220-CZC SA 60+

P tl F/Z

_1E51mP-051 LOOP LEVEL PUIP 235 PD GOLA.D P' tp SC008 YES HE-320 SA 60+

F CS H

U

  • CS COLD SHtJT 00lti P : PIPE HOLAffED SBTzSINGLE FREQUENCY QUALIFICATI0tt HILEST0t!ES PEJISIGN 5 -DECEICER 1982 1'

D DUCT HOUNTED PC zPRIllARY Col.i.

BIAXIAL TESTIrlG A mREEVALUATION C0tPLETE DA zDYNAllIC AllALYSIS PL PEDESTAL SC zSEC0f10ARY CONT.

B mREQUEST FOR QUAL OR BID ISSUED t;0TE E tFL".CER Il4 F zFLOOR tt0LAliED QP = QUALIFIED BY

/ mLOCATED ON CONT.

C zS/H RECot:tEt1DATION TO LILCO -

' TYPE HTfG' CCLt3tt IS HS zHOT STAT 0BY PIPING ANALYSIS HALL D zQUAL DOC RECEIVED QUANTITY OF ITLt;S.

?

IBTattULTI-FREQUCHCY SA zSTATIC ANALYSIS H zNEITHER CS OR HS E st!ARDHARE It0DIFICATION RFQ'D

~

BIAXIAL TESTING SATzSINGLE FREQUENCY Z PASSIVE ITEN F zQUAL DOC APVD & FILED i

HSTallULTI-FREQUEt1CY sit 1GLE AXIAL TESTING E SQRT PAPER NOT G zSQ'IT PAPER C0tFLETE l

SINGLE AXIAL TESTING REQ'DI H COPIES OF DOC TO DISTRIDUTION i

1 1

y SHOREHAH (MIT 1 RB LIST STONE & HE'.STE2 ENGINEERING CORPORATION RUN DATE 12/20/02 JOB HUtBER 11400 1-SORT REACTOR BUILDING CATEGORY I FLOOR-ItutRETED EQUIPHENT RUN TIttE 13.19.20 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (205 ITEMS)

PAGE 3 HARN EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE SAFE CUfL HUteER DESCRIPTION HO.

RESP VEtGOR ELEV Itt3P REPT HETH FREQ llTHS S!!TCil STATUS 1E51mPT 142 TO LUBE OIL COOLER 404 CD ROSEHOLRET SC8 YES 127516 IET 60+

F C3.HS H IE51mRD-003 RUPTURE DISH 340 PD LYONS ItO/BS&B SC14 YES Nt-1 SAT 40+

F HS F/Z IE51mRO-004 RUPTURE DISH 340 PD.

LYONS Ite/BSSB SC13 YES tot-1 SAT 60+

F HS F/Z IE51mRO 131 RCIC PLRP HIH FLON SYP 440 CD PERHUTIT SC19 YES ItHB) 220-CZC SA 40+ P HS F/Z 1E51mRO 132 RCIC P DIS TO Cote STR 440 CD PERitJTIT SC20 YES tetEBI 220-CZC SA 40+

P tt F/Z IE51mRO 135 RtPTistE DISH BLEED OFF 440 CD PERHUTIT SC20 YES tet(B) 220-CZC SA 60+

P I4 F/Z 1E51mRO 134 STOP VALVE DRAIN 440 CD PERDAJTIT SC15 YES t#1(B) 220-CZC SA 40+

P HS F/Z IE51mRO 137 RCIC LEVEL P-51 440 CD PERHUTIT SCid YES t#NBl 220-CZC SA 60+

P HS F/Z 1E51mRO 138 TO BARottETRIC Cote 440 CD PERtRJTIT SC9 YES teHBS 220-CZC SA 40+

P HS F/Z IE51mRO 153 RUPTURE DISH BLEED OFF 440 CD PERttJTIT SC20 YES teHB) 220-CZC SA 60+

P tl F/Z i

i 1E51mS-054 Y STR-RCIC LOOP LEVEL 148 PD LESLIE C0 SC008 YES teHB) 287-CZC DA 40+

P HS F/Z IF16mRAM-22 HI DENSITY SPNT FUEL R 427 PD HACHTER SC137 YES LIL-T-151 DA 10 F29 H

H 1F14mRAM-23 PERH CR STOR RACHS 427 PD HACHTER SC137 YES LIL-T-151 DA 10 F

N II 1

IF16mRAH-24 TEtr CR STOR RACHS 427 PD HACHTER SC137 YES LIL-T-151 OA 10 F2 ft H

1G11mFT d47

$UPP POOL PUlf BACH 404 CD ROSEHOUN7 SC006 YES 127514 IBT 40+

F3 CS,HS H i

j 1G11mLE 442 RB FLOOR LEVEL 473 CD DELAVAL SC008 DA F

D f

1G11mLE 445 RB FLOOD LEVEL 473 CD DELAVAL SC008 YES SAT F2 B

i 1633mRO 109 P-19 DISCH CHN V.BYPS 440 CD PERHUTIT SC120 YES t#HB) 220-CZC SA 60+ P2 ft F/Z 1

IG41mE-019 FUEL STG POOL HT EXCHA 190 PD STRUTHERS CO SC151 YES 70-04-30787 SA 25 F2 CS.HS H 1G41mFE 027

$ PENT FUEL POOL C00LIN 440 CD PERtRJTIT SC166 YES POM B ) 220-CZC SA 60+

P2 H

F/Z i

]

_1G41mP-023 FUEL STORAGE POOL COOL 062G PD Gott.D PtRP SC151 YES HE-325 SA 33 F2 14 H

CS aCOLD SHUT D0124 P

PIPE HOUNTED SBTzSINGLE FREQUENCY QUALIFICATI0tl HILESTONES REVISI0tt 5 -CECEl:CER 1952 D

3 DUCT 110UNTED PC :PRIttARY C0 tit.

BIAXIAL TESTItiG A mREEVALUATICit COIPLETE DA :DYtIAllIC AtlALYSIS PL : PEDESTAL SC zSECONDARY CatfF.

B sREQUEST FOR QUAL OR DID ISSUED tt0T E im E2 Iti 1

l F zFLOOR HOUtiTED QP s QUALIFIED BY

/ zLOCATED ON CONT.

C zS/H RECatiltEtIDATION TO LILCO

' TYPE ttit:S' CCLL:04 IS HS = HOT STAtiDBY PIPIttG AttALYSIS HALL D sQUAL DOC RECEIVED QUAtITITY CF ITU G.

I HDT:11ULTI-FREQUEtCY SA = STATIC ANALYSIS H stIEITHER CS OR HS E zHARDHAPE ISCDIFICATION REQ'O I

7.

BIAXIAL TESTIttG SATxSItiGLE FREQUEICY Z cPASSIVE ITEH F zQUAL DCC APVD & FILED j

llST:HULTI-FREQUEttCY SINGLE AXIAL TESTING (SQRT PAPER HOT G zSQRT PAPER C0t!PLETE

]

SIUGLE AXIAL TESTING REQ'DI H zCOPIES OF DOC TO DISTRIBUTION 1

i s

SHOREHAH L2 TIT 1 RB LIST ST0tII & HEBSTER ENGINEERING CORPORATIDH RUN DATE 12/20/32 JOB Hut 2ER 11600 1-SORT REACTOR BUILDING CATEGORY I FLOOR-I!OUNTED EQUIPHENT RUN TIltE 13.19.20 LILCO 00CHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (205 ITEttS)

PAGE 4 HARH EQUIPitENT SPEC DIV.

BLOG AVAIL QUAL QUAL TYPE SAFE QUAL tRJtEER DESCRIPTION HO.

RESP VEtEOR ELEV INSP REPT HETH FREQ llTl!G SitTott STATUS IH50eFE 062 RB STAtOBY VENT UC-2 440 CD PERIUTIT SC13 YES ttf(B) 220-CZC SA 60+

P2 CS F/Z 1H50nFE 063 RB STAtGBY VENT UC-3 440 CD PERifUTIT SC11 YES tettB) 220-CZC SA 60+

P2 CS F/Z lil50nFE 064 RB STAleBY VENT UC-4 440 CD PERtMTIT SC224 YES Ml(B) 220-CZC SA 60+ P2 CS F/Z 1H50mFE 065 RB STAFEBY Vein UC-5 440 CD PERlIUTIT SC223 YES tet(BI 220-CZC SA 60+

P2 CS F/Z IM50=FE 066 RB STAteBY VENT UC-6 440 CD PERHUTIT SC136 YES Ml(B) 220-CZC SA 60+

P2 CS F/Z lit 50mRO 072 RB STAreBY VENT UC-2 440 CD PERifUTIT SC11 YES teffB) 220-CZC SA 60+

P2 CS F/Z i

1H50mRO 073 RB STAtmBY VENT UC-3 440 CD PERHLtTIT SC13 YES IGHB) 220-CZC SA 60f P2 CS I/Z I

1H50nRO 074 Rr,STAtSBY VENT UC-4 440 CD PERIIUTIT SC222 YES MHDI 220-CZC SA 60+

P2 CS F/Z 1H50mRO 075 RB STANDBY VENT UC-5 440 CD PERHUTIT SC222 YES MHB) 220-CZC SA 60+ P2 CS F/Z i

1H50mRO 076 RB STAT 0BY VENT UC-6 440 CD PERHUTIT SC135 YES NMBI 220-CZC SA 60+

P2 CS F/Z 1P41mFT 146 RBCLCH HX SERV HATER 406 CD ROSEll0UNT SC024 YES 127516 MIT 60+

F2 CS.HS 11 1P41mFT 151 RAD H0H SAtPLE 406 CD ROSEHOUNT SC008 YES 127516 HBT 60+

F2 CS.HS H l

1P42mE-011 RBCLCH HT EXCHANGER 190 PD STRUTHERS C0 SCS YES 70-06-30786 SA 12 F2 CS.HS H IP42mE-117 BOOSTER HT EXCH 190 PD STRUTHERS SC8 YES 19-06-33475 SA 5+

F2 HS is IP42mFE 017 FUEL POOL HX E-19A DIS 440 CD PERT 1UTIT SC157 YES tet(B ) 220-CZC SA 60+ P2 N

F/Z i

{

IP42mFE 018 RECIRC PUIP COOLERS 440 CD PERtUTIT SC67 YES NH B) 220-CZC SA 60+ P2 H

F/Z IP42aFE 060 RHR PLAP SEAL CLR A 440 CD PERHUTIT SC13 YES Itf(B) 220-CZC SA 60+

P4 H

F/Z 1P42aLS 012 RSCLCH TM-026 407 CD HAGNETROL SC160 YES 43235-1 H3T 17 F2 HS 11 IP42mLS 013 RBCLCH TH-026 407 CD HAGNETROL SC160 YES 43235-1 HDT 17 F2 HS H

IP42mP-005 RB CLOSED LOOP COOLING 062G PD GOLA.D PLAP SC151 YES HE-354 SA 68 F3 HS H

i

_1P42aPS 021 PUtr IP42eP005C DISCH 348 ED ASCO SC153 YES 178 SAT 60+

F3 HS H

i CS zCOLD SHUT D0lti P : PIPE IlotAITED SBTzSINGLE FREQUEllCY QUALIFICATION HILEST0 ties REVISICH 5 -DECEll3ER 1902 D : DUCT HOUNTED PC :PRIHARY CollT.

BIAXIAL TESTIttG A mREEVALUATI0tl COMPLETE t

DA =0YtIAHIC ANALYSIS FL =PE0ESTAL SC =SECorIDARY CONT.

B sREQUEST FOR QUAL OR BID ISSUED tt01Et FU.rXR Ill l

F zFLOOR HOUNTED QP = QUALIFIED BY

/ zLOCATED att CONT.

C =S/H FEcotttEt:DATION TO LILCO

' TYPE IITt;G* CCLLU4 IS HS SHOT STAT 0BY PIPIttG AtIALYSIS HALL D QUAL 00C RECEIVED QUAtlTITY CF ITE!!S.

i HBTzHULTI-FREQUENCY SA sSTATIC AtlALYSIS H HEITHER CS OR llS E =HARDHARE 11001FICAT10H REQ'D I

BIAXIAL TESTIttG SATzSItlGLE FREQUEtiCY Z zPASSIVE ITEll F zQUAL DOC APVD & FILED HST=tfULTI-FREQUEttCY SItiGLE AXIAL TESTING (SQRT PAPER HOT G zSQRT PAPER CollPLETE SIllCLE AXIAL TESTING REQ'DI H zCOPIES OF 00C TO DISTRIBUTION 2

j

~I

\\

SHOREHAH LMIT 1 RB LIST STot2 & HEBSTER ENGINEERING CORPORATION RtRI DATE ?2/20/82 JOB IAABER 11603 1-SORT REACTOR BUILDItG CATEGORY I FLOOR-HOUNTED EQUIPHEHT RUN TIttF 13.19.20 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (205 ITEttS)

PAGE 5 HARM EQUIPHENT SPEC DIV.

BLOG AVAIL QUAL QUAL TYPE SAFE QU?L NUtBER DESCRIPTION HO.

RESP VEtBOR ELEV INSP REPT HETH FREQ llTt:S S:ITC!4 STATUS 1P42mPS 022 PUtr IP42eP0058 DISCH 348 EO ASCO SC153 YES 178 SAT 60+

F3 IIS 61 IP42nPS 044 PUtr IP42mP005A DISCH 348 ED ASCO SC151 YES 178 SAT 60+

F3 HS H

~

IP42mTH-026 RBCLCH HEAD tat 0(

114 PD DUFFALO TAtG(

SC151 YES t#1(B125-IA SA F2 HS D

1P50mPS 105 SERV AIR HDR PRESS 348 ED ASCO SC102 178 SAT 60+

F2 CS.HS H IP50mPS 113 SERV AIR HDR HORH SUP 348 ED ASCO SC102 178 SAT 60+

F2 CS,HS H IP50mPT 111 AOS ACCUt1ULATOR 406 CD ROSEHOUNT SC101 YES 127516 IBT 60+

F2 CS.HS 11 IP50 APT 116 SERV AIR HOR PRESS 404 CD ROSEHOUNT SC101 YES 127516 FBT 60+

F2 CS.HS 11 1R24mHCC-111H HTR CHTRL Ct(TR 115 ED SQUARE D CO SC150 YES 108-1.01-L2 IBT 4

F CS el!S H 1R24aHCC-111X HOTOR CotiT CHTR BUS 1 115 ED SQUARE D C0 SC113 YES 108-1.01-L2 IBT 4

F CS ltS H IR21mHCC-111Y HOTOR CONT CNTR, BUS 1 115 ED SQUARE D CO SC78 YES 108-1.01-L2 HDT 4

F CS itS H l

1R24attCC-111Z HOTOR CONT Ct(TR. BUS 1 115 FD SQUARE D C0 SC78 YES 108-1.01-L2 IBT 4

F CS.IIS H 1R24mHCC-112H HOTOR CollT CNTR BUS 1 115 ED SQUARE D CO SC150 YES 108-1.01-L2 IBT 4

F CS,ltS H 1R24aHCC-112X HOTOR CONT CNTR. BUS 1 115 ED SQUARE O CO SC78 YES 108-1.01-L2 IBT 4

F CS.HS H 1R24mitCC-112Y HOTOR CONT CNTR. BUS 1 115 ED SQUARE D CO SC112 YES 108-1.01-L2 tBT 4

F CSetLS H 1R24mitCC1111 HOTOR CatfT CifTRs BUS 1 115 ED SQUARE D CO SC40 YES 108-1.01-L2 IBT 4

F CS.HS 11 i

1R24milCC1112 It0 TOR CONT CNTR BUS 1 115 ED SQUARE D CO SC113 YES 108-1.01-L2 IBT 4

F CS ells H j

1R24attCC1113 HOTOR CONT CNTR BUS 1 115 ED SQUARE D CO SC113 YES 108-1.01*-L2 HBT 4

F CS.HS H 1R24eHCC1114 HOTOR CONT CitTR. BUS 1 115 ED SQUARE D CO SC151 YES 108-1.01-L2 HDT 4

F CS.HS H o

1R24mHCC1117 HOTOR C0tlT CNTRe BUS 1 115 ED SQUARE D CO SC40 YES 108-1.01-L2 tBT 4

F CS.IIS 11 l

l 1R24mitCC1118 480 V HOTOR CONT CEtiTE 115 ED SQUARE D CD SC113 YES 108-1.01-L2 IBT 4

F CS.H3 11

)

_1R24mtCC1119 480 V HOTOR CONT CENTE 115 ED SQUARE D C0 SC40 YES 108-1.01-L2 DET 4

F CS,HS 18 l,

CS = COLD SHUT 00lm P : PIPE HOUNTED SBT=SItlCLE FREQUENCY QUALIFICATION HILESTottES REVISI0tt 5 -DECEt! DER 1982 i

D =0UCT HOUtlTED PC :PRIllARY CONT.

BIAXIAL TESTIts A zREEVALUATI0tt ColFLETE i

DA :DYttAHIC AtlALYSIS PL : PEDESTAL SC zSEtatiOARY Cot lT.

B zREQUEST FOR QUAL OR BID ISSUED tiOT E I;U:CER Ill

}

F zFLOOR HotAITED QP = QUALIF1ED BY

/ zLOCATED ON CotiT.

C =S/H REC 0!EIEttDATI0tl TO LILCO

' TYPE HTNG' CCLt";:4 IS HS zHOT STAT 3DDY PIPItlG ANALYSIS HALL D zQUAL DOC RECEIVED QUAtlTITY OF ITEtIS.

t HST=l!ULTI-FREQUEllCY SA zSTATIC AtlALYSIS H *HEITHER CS OR HS E *HAR0ltARE HODIFICATION REQ'O I

BIAXIAL TESTING SAT =SIttCLE FREQUEICY Z zPASSIVE 1TEtt F zQUAL OCC APVD & FILED j

ttSTalIULTI-FREQUENCY SIllGLE AXIAL TESTING (SQRT PAPER HOT G zSCRT PAPER CollPLETE 1

sit 4GLE AXIAL TESTING REQ'Ol H zCOPIES OF DOC TO DISTRIBUTICH i

h

O O

O

~

SHOREHAH LRtIT 1 RB LIST STONE & HEBSTER Et4GINEERING CORPORATION RUN DATE 12/20/82 JOB tAREER 11600 1-50RT REACTOR BUILDIts CATEGORY I FLOOR-IIOUNTED EQUIPHENT RUN TIltE 13.19.20 LILCO DOCHET 50-322 ACTIVE -

BOP QUALIFICATION LEVEL (205 ITEllS)

PAGE 6 HARH EQUIPHENT SPEC DIV.

BLOG AVAIL QUAL QUAL TYPE SME CUAL NUHOER DESCRIPTION HO.

RESP VEte0R ELEV INSP REPT HETH FREQ llTitS CllTritt STATUS 1R24.IICC1121 HOTOR CONT CitTR. BUS 1 115 ED SQUARE D C0 SC40 YES 108-1.01-L2 teT 4

F CS.HS H 1R24eHCC1122 HOTOR CONT CNTR. BUS 1 115 ED SQUARE D CO SC19 YES 108-1.ul-L2 HDT 4

F CS.tts H 1R24stlCC1123 HOTOR CONT CliTR. BUS 1 115 ED SQUARE D CO SC113 YES 108-1.01-LZ IST 4

F CS !!S H 1R24*llCC1124 HOTOR CONT CNTR. BUS 1 115 ED SQUARE D CO SC151 YES 108-1.01-L2 SST 4

F CS ells H 1R24mHCC1127 HOTOR CONT CNTR. BUS 1 115 ED SQUARE D CD SC40 YES 108-1.01 L2 HDT 4

F CS.HS H 1R24mHCC1128 480 V HOTOR r?NT CENTE 115 ED SQUARE D CO SC113 YES 108-1.01-L2 IST 4

F CS.HS H 1R24mHCC1129 480 V tt0 TOR CONT CEllTE 115 ED SQUARE D CO SC40 YES 108-1.01-L2 HDT 4

F CS.t!S 11 1R24mitCC1131 HOTOR CotiT CNTR BUS 1 115 ED SQUARE D CO SC63 YES 108-1.01-L2 HST 4

F CS.Its H 1R24 mis-111 LPCI HG SET 439 ED LOUIS ALLIS SC150 YES HE498 SA 27 F

tl H

1R24mitG-112 LPCI HG SET 439 ED LOUIS ALLIS SC150 YES HE698 SA 27 F

tl H

1R24*ttG-113 LPCI HG SET 439 ED LOUIS ALLIS SC150 YES HE698 SA 27 F2 il il IR24mPtL-B1 480 VAC CMT BHR 115 ED SQUARE D C0 SC112 YES 8998-10.09-L23 ICT 20 F

CS.its il IR24aPtL-G1 480 VAC CHT BHR 115 ED SQUARE D CO SC112 YES 8998-10.09-L23 PET 20 F

CS itS H 1R24aPtL-R1 480 VAC CNT BHR 115 ED SQUARE D C0 SC112 YES 8998-10.09-L23 IST 20 F

CS.IIS H 1R24ePtL-R2 480 VAC CHT BHR 115 ED SQUARE D CO SC112 YES 8998-10.09-L23 IBT 20 F

CS.HS H 1R24mPit-Y1 480 VAC CHT BHR 115 ED SQUARE D CO SC112 YES 8998-10.09-L23 IET 20 F

CS.HS H 1R24aPtL-01 480 VAC CNT BHR 115 ED SQUARE D CO SC78 YES 8998-10.09-L23 HBT 20 F

CS !!S H 1R24mPtL-02 480 VAC CNT elGt 115 ED SQUARE D CO SC78 YES 8998-10.09-L23 HDT 20 F

CS.its H 1R24mPtL-03 a600 VAC CMT BHR 115 ED SQUARE D CO SC78 YES 8998-10.09-L23 IST 20 F

CS.HS H 1RP +tL-04 480 VAC CNTRL Pt5t FEED 115 ED SQUARE D C0 SC112 YES 8998-10.09-L23 IST 20 F

CS.HS H

_1R2%r'tL-111 LPCI SIP Pit 439 ED LOUIS ALLIS SC150 84-66829 fBT 27 F

- tt 0

CS COLD SHUT D0lti P = PIPE HOUNTED

$8TzSINGLE FREQUENCY QUALIFICATION HILESTO!IES REVISION 5 -DECEICER 1982 D : DUCT HOUNTED PC =PRIltARY CottT.

BIAXIAL TESTIts A tREEVALUATI0tt C005'LETE DA DYHAHIC AttALYSIS PL : PEDESTAL SC sSEC0 TEARY CatfT.

B zREQUEST FCR QUAL OR BID ISSUED t:0TE: IC:CER Ifl F zFLOOR HOUtlTED QP a QUALIFIED BY

/ zLOCATED ON CONT.

C zS/H RECO:IttEtOATI0tt TO LILCO

' TYPE ttit:G' CCLL"Of IS HS = HOT STANOBY PIPITS ANALYSIS HALL D sQUAL DOC RECEIVED QUANTITY CF ITEt:3.

_ HOTzHULTI-FREQUEllCY SA sSTATIC AtlALYSIS H stiEITHER CS OR HS E sHARCHARE HDDIFICATION REQ'O BIAXIAL TESTIttG SATzSIt4GLE FREQUENCY Z = PASSIVE ITEH F = QUAL DCC APVD & FILED HST=ll'JLTI-FREQUEllCY SINGLE AXIAL TESTING (SQRT PAPER HDT G mSCRT PAPER COI:PLETE SINGLE AXIAL TESTIts REQ'Di H zCCPIES OF DOC TO DISTRIBUTION P

SHOREHAM LRtIT 1 R3 LIST STONE & HEBSTE3 ENGINEERING CORPORATICH RUN DATE 12/20/02 JOB HUlBER 11600 1-SORT REACTOR BUILOIllG CATEGORY I FLOOR-HOUNTED EQUIPilEIR RtX4 TIttE 13.17.20 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (205 ITEHS)

PAGE 7 HARM EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE SAFE CU',L HutBER DESCRIPTION HO.

RESP VEtIDOR ELEV INSP REPT ltETH FREQ HitiS SliTDil STATUS 1R24mPtL-112 LPCI SIP PtL 439 ED LOUIS ALLIS SC150 84-66829 HBT 27 F

H B

1R24mPtL-113 LPCI SIP PIL 439 ED LOUIS ALLIS SC150 84-66829 tBT 27 F2 N

B 1R24mTRS111X LCPI ATS 438 ED ASCO SC112 YES 19606 DET

'J F

C3.IIS H 1R24mTRS112Y LCPI ATS 438 ED ASCO SC112 YES 19606 DET 13 F

CS ells H 1R35mPtL-B2 EHER 120 V PtL B2-SC 124 ED SYSTEN CONT SC112 YES 45322-1 FET 15 F CS itS H 1R35mPtL-R2 EHER 120 V PtL R2-SC 124 ED SYSTEH CONT SC112 YES 45322-1 IET 15 F CS ell 3 H 1R35mT-62 480-120/240V TRANS 248 ED HAGNETICS SC112 YES HYLE 43424-1 DET 9

F CS.HS H 1R35mT-R2 480-120/240V TRAftS 248 ED HAGHETICS SC112 YES HYLE 43424-1 HBT 9

F CS.HS 11 1R42mHCC-0A1 125 VDC HOTOR CONT CEN 168 ED GEN ELEC SC40 YES 79GPC005 SAT 100 F CS its H 1R42mttCC-0A2 125 VDC HOTOR CONT CEN 168 ED GEN ELEC SC112 YES 79GPC005 SAT 100 F LS.HS H 1R42mHCC-081 125 VDC HOTOR CONT CEN 168 ED GEH ELEC SC40 YES 79GPC005 SAT 100 F CS.itS H 1R42mitCC-082 12C VDC HOTOR CONT CEN 168 ED GEN ELEC SC112 YES 79GPC005 SAT 100 F CS.IIS H k

1T23mSHE-01 SHIELD HALL EXTENSION 221 PD CIVES PC140 YES tGHB1124-GO SA 60+

F N

D/Z 1T23mTL-002 PRIHARY C0 TIT LIHER 075 SD PDM PC006 YES HStB) - EA54 SA 3

F tl F/Z 1T23mZ-EA1 REACTOR CONT ELEC PEN 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F

CS.HS F

]

1T23mZ-EB1 REACTOR CottT ELEC PEH 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F

CS.IIS F IT23mZ-EB2 REACTOR CONT ELEC PEH 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F CS.ltS F IT23mZ-EDS REACTOR CONT ELEC PEN 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F

CS.itS F IT23mZ-ED6 REACTOR CONT ELEC PEN 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F

CS.itS F l

IT23mZ-tB3 REACTOR C0 tit ELEC PEN 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F

CS.IIS F

]

_ 1T23mZ-HB4 REACTOR CONT ELEC Peri 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F

CS tf3 F 1

I i

CS zCOLD SHUT 00144 P : PIPE HOUNTED SBTzSINGLE FREQUENCY QUALIFICATION HILESTONES REVISION 5 -DECEtCER 1922 O

DUCT 110UNTED PC :PRItfARY CONT.

BIAXIAL TESTIllG A mREEVALUATION CollPLETE DA :DYttAtlIC ANALYSIS PL zPEDESTAL SC zSEC0ftDARY CONT.

B zREQUEST FOR QUAL OR BID ISSUED liciE: TEED Ill F = FLOOR HOUNTED QP m QUALIFIED BY

/ xt0CATED ON CONT.

C =S/H REC 0!!!!EllDATION TO LILCO

' TYPE IITI:S' CCLtJ."1 IS I

HS zHOT STAriDBY PIPING AttALYSIS HALL D zQUAL DOC RECEIVED QUAtiTITY OF ITEttS.

fBTzHULTI-FREQUENCY SA zSTATIC AtlALYSIS H zitEITHER CS OR HS E zHARDHAPE ff0DIFICATI0tl REQ'D j

~

BIAXIAL TESTIllG SATzSIllGLE FREQUENCY Z zPASSIVE ITEM F zQUAL DOC APVD & FILED HST_zHULTI-FREQUEraCY SIllGLE AXIAL TESTING (SQRT PAPER HOT G zSQRT PAPER CollPLETE i

SINGLE AXIAL TESTING REQ'D)

H zCOPIES OF DOC TO DISTRIBUTI0tt 1

I i

a 4

u O"

Os s

SHOREHAN UNIT 1 98 LIST STONE & HEB' STER ENGINEEXING CORPORATION RUN DATE 12/20/02 JOB HUtIDER 11600 1-SORT REACTOR BUILDIrlG CATEGORY I FLOOR-Il0UNTED EQUIPHENT RUH TIllE 13.19.20 l

LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (205 ITEllS)

PAGE 8 HARN EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE CAFE CUAL tlUtIDER DESCRIPTICH NO.

RESP vet 90R ELEV INSP REPT HETH FREQ llTilG Sillcti STATUS 1T23 Z-HC4 REACTOR CotiT ELEC PEN 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F

CS,HS F IT23mZ-lei REACTOR CONT ELEC PEN 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F

CS.HS F IT23 mZ-tet REACTOR C0 tit ELEC PEN 134 ED GEN ELEC CO PC078 YES F73414 SAT 24 F

CS,llS F IT23-RB-001 PH RES RADIAL BEAMS 221 PD CIVES PCVAR YES IMIDl89-JAA SA 16 F

CS D/Z IT46mA00040 RB REFUEL LVL EXHAUST 319 CD P0HERS REGLA.

SC154 YES 44540-1 SA/ SAT 40 F2 CS 11 IT46mAOD041 RB POT Cat lTAH AREA EXH 319 CD P0HERS REGLA.

SC112 YES 43812-1 SA/ SAT 24 F2 CSellS 11 IT46mCLC-05 RBSVS COOLING COILS 276 PD BUFFALO FORGE SC113 YES 80N-27781 SA 5

F2 CS,HS H 1T46mFLT-01 RBSVS FILTER TRAINS 105 PD FARR C0 SC112 YES D-56291 SA/ SAT 11 F2 CS lis H 1T46mFN-003 RB EXH FAtlS-RBNVS 270 PO BUFFALO FORGE SC124 YES 745-11136 SA 15 F3 CS H

IT46mFil-079 RB EXH BOOSTER FAN 102 PD BUFFALO FORGE SC133 YES 745-4244C SA 51 F2 CS ells H IT46mFT 004 RBSVS EXH AIR FLOH 319 CD P0HERS REGLA.

SC112 YES 43812-1 SA/ SAT 24 F2 H

H IT46 mile 002 FLT-1 HOISTURE 319 CD PCHERS REGUL SC112 YES 43812-1 SA/ SAT 24 F2 ll H

1T46mtt00031 RBSVS ItLET TO HIX PLN 319 CD P0HERS REGLA.

SC135 YES 43812-1 SA/ SAT 24 F2 CS,Ils il IT44mHOD034 RBSVS FILTER TRAIN DCH 319 CD P0HERS REGtt.

SC182 YES 44540-1 SA/ SAT 60 F2 CS H

i 1T46mH00036 Fi!-3 DISCHARGE AIR 319 CD P0HERS REGUL SC126 YES 43812-1 SA/ SAT 24 F3 CS.HS 11 IT46 mil 00047 FN-79 DISCHARGE AIR 319 CD P0HERS REGtL SC112 YES 43812-1 SA/ SAT 24 F2 ti il IT46mHOD048 FLT-1 ItLET AIR 319 CD P0HERS REGtL SC112 YES 43812-1 SA/ SAT 24 F2 H

H IT46mPDSO45 FN-3 DIFF PRESSURE 319 CD P0HERS REGLA.

SC112 YES 43812-1 SA/ SAT 24 F2 CS.ltS 11 IT46mPDS046 FN-3 DIFF PRESSURE 319 CD P0HERS REGtR.

SC112 YES 43812-1 SA/ SAT 24 F3 CS.HS H 1T44mPDT003 FLT-1A DIFF PRESSURE 406 CD ROSEll0UNT SC112 YES 127516 IET 60+

F2 CS.HS 11 j

_1T46mPDT043 REACTOR BLDG DIFF 406 CD ROSEHOUliT SC220 YES 127516 HDT 60e F2 CSells it i

CS zCOLD SHUT DOHtt P : PIPE HOUNTED SBT=SIllCLE FREQUENCY QUALIFICATION HILESTotlES REVISI0tt 5 -DECE!!CER 1982 D = DUCT HOUNTED PC PRIHARY CONT.

BIAXIAL TESIIHG A mREEVALUATI0tt C0tlPLETE DA zDYllAHIC AtlALYSIS PL : PEDESTAL SC =SEC0tOARY C0tlT.

B zREQUEST FOR QUAL OR BID ISSUED tt0TE: ICER Ill j

F zFLOOR ll0UNTED QP = QUALIFIED BY

/ zLOCATED ON C0 tit.

C zS/H REcollitEtIDATI0tt TO LILCO

' TYPE IITI;S' CCLtf:'l IS HS zHOT STANDBY PIPING AHALYSIS Ht.LL D = QUAL DOC RECEIVED CUANTITY 07 ITEtts.

_tBTzHULTI-FREQUEllCY SA zSTATIC ANALYSIS H zHEITHER CS OR HS E zHARDHARE HODIFICATION REQ'O BIAXIAL TESTIttG SATzSIllGLE FREQUENCY Z : PASSIVE ITEH F zQUAL DOC APVD & FILED j

llSTzilULTI-FREQUENCY SItiGLE AXIAL TESTING (SQiti PAPER NOT G zSQRT PAPER CollPLETE SIllGLE AXIAL TESTING REQ'DI H zCOPIES OF DOC TO DISTRIBUTION l

SHOREHAH UHIT 1 CS LIST STONE & HEBSTER ENGINEE21HG CORPORATION RUN DATE 12/20/02 JOB HUl2ER 11400 1-SORT REACTOR BUILDING CATEGORY I FLOOR-HOUNTED EQUIPHENT RUN TIttE 13.19.20 LILCO DOCHET 50-322 ACTIVE BOP QUt.LIFICATION LEVEL (205 ITElls)

PAGE 9 IIARM EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE SAFE CUAL NUtBER DESCRIPTION t10.

RESP VEtOOR ELEV INSP REPT IIETH FREQ HTitG E!!Tott STATUS IT46mTE 001 RBSVS RECIRC AIR TElf 404 CD ROSEHOUttT SC144 YES 2767 SAT 60+

F2 CS.l:S H IT46mTE 022 AIR RETURN TO UC-2 406 CD ROSEHOUNT SCIO YES 2767 CAT 60+

F2 C5 tts H 1T46mTE 023 AIR RETURN TO UC-3 406 CD ROSEHOUNT SC42 YES 2767 SAT 60+

F2 CS.!!S H IT46mTE 024 AIR RETURN TO UC-4 406 CD ROSEHOUNT SC220 YES 2767 SAT 60+

F2 CS.IIS Il IT46mTE 025 AIR RETURif TO UC-5 406 CD ROSEl100HT SC220 YES 2767 SAT 60+

F2 CS lis 11 IT46mTE 028 HCC RH UNIT COOLER 406 CD ROSEtt0UNT SC128 YES 2767 SAT 60+

F2 CS.HS H IT46mTE 059 auC-21 UNIT CLR 406 CD ROSEtt0UNT SC155 YES 2767 SAT 60+

F2 CS.IIS 11 IT44mTE 060 mUC-22 UNIT CLR 406 CD ROSEHOUNT SC160 YES 2767 SAT 60+

F2 CS.HS H IT46mUC-002 UNIT COOLERS-RBSVS 274 PD BUFFALO FORGE SC8 YES 80H-27781 SA 5

F2 CS.itS 11 IT46muC-003 UNIT COOLERS-RBSVS 274 ' PD BUFFALO FORGE SC008 YES 80H-27781 SA 5

F2 CS.HS H IT46mUC-004 UNIT COOLERS-RBSVS 276 PD BUFFALO FORGE SC175 YES 80H-21781 SA 5

F2 CS tis It IT46 UC-005 UNIT COOLERS-RBSVS 274 PD BUFFALO FORGE SC175 YES 80H-27781 SA 5

F2 CS.HS ll IT46mVC-020 UNIT COOLERS-HCC IN RB 274 PD BUFFALO FORGE SC112 YES 80H-27781 SA 5

F2 CS.HS H I

l IT46mUC-021 UNIT COOLERS 276 PD BUFFALO FORGE SC150 YES 80H-27781 SA 5

F2 CS.HS H 1T46 UC-022 UNIT COOLERS - RBSVS 276 PD BUFFALO FORGE SC161 YES 80H-27781 SA 5

F2 CS.H3 H 1T46mUC-023 UNIT COOLER HCC RB 276 PD BUFFALO FORGE SC040 YES 80H-27903-4 SA 5

F fl 11 IT48mEXJ-49 HYD REC 01B ItLET EX JT 462 PD TEtP FLEX SC114 SA F2 il B/Z IT48mEXJ-50 HYD-REC 0tB ItLET EX JT 462 PD TElP FLEX SC114 SA F2 H

B/Z 1

1T48mFE 005 HEPA FILTER ItLET 440 CD PERHUTIT SC114 YES #91( B ) 220-CZC SA 60+

P N

F/Z IT48mFE 048 HATER SUPPLY TO mRC-Ots 440 CD PERIIUTIT SC113 YES t0HB) 220-CZC SA 60+ P H

F/Z

_1T48mFT 005H HEPA FILTER ItLET 404 CD ROSEHOUNT SC113 YES 127516 SAT 60+

F2 CS.HS H CS

  • COLD SitUT DOHN P PIPE HOUNTED SBTzSINGLE FREQUENCY QUALIFICATION HILEST0tlES REVISIOil 5 -0ECEICER 1902 j

D sDUCT 110UtiTED PC :PRIHARY CONT.

BIAXIAL TESTING A =REEVALUATI0tl C0!PLETE DA =0YHAllIC AttALYSIS PL : PEDESTAL SC zSECO!IDARY CONT.

B mREQUEST FOR QUAL OR BID ISSUED t;0IE: i:U:OER Ill i

F FLOOR HOUllTED QP = QUALIFIED BY

/ zLOCATED ON CONT.

C =S/H REC 0tt1EtOATION TO LILCO

' TYPE IITt;G' COLUt':4 IS j

HS = HOT STA!!DBY PIPING AftALYSIS HALL D sQUAL DOC RECEIVED QUAtiTITY OF ITEt;S.

itST:tfULTI-FREQUENCY SA zSTATIC AttALYSIS H *HEITHER CS OR HS E =HAROHl.RE I:001FICATION REQ'O I

BIAXIAL TESTING SAT =SIrlCLE FREQUENCY Z zPASSIVE ITEH F zQUAL 00C APVD 1 FILED I

HST=tRA.TI-FREQUEttCY SINGLE AXIAL TESTING (SQ2T PAPER HOT G zSQRT PAPER CollPLETE l

SINGLE AXIAL TESTING REQ'D1 H aCOPIES OF 00C TO DISTRIBUTION

)

I r

O O

u 4

SHOREHAH IAIIT 1 R3 LIST STONE & HEISTER ENGINEERItG CORPORATI0tl RUN DATE 12/20/02 JOB HUIEER 11600 1-SORT REACTOR BUILD 1tG CATEGORY I FLOOR-HOUNTED EQUIPHENT RUti TIME 13.19.29 LILCD 00CHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (205 ITEHS)

PAGE 10 llARH EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL

' TYPE SAFE OJAL NUtBER DESCRIPTION NO.

RESP VEte0R ELEV IllSP REPT HETH FREQ HT!!S Sil1Dil STATUS 1T48 LS 061 Cote LEVEL 407 CD HAGNETROL SC73 YES 43235-1 IBT 17 F2 HS 18 IT48mPtL-48 HYD REC 0tB P0HER CA8IN 289 PD ATCHICS INT SC112 YES 58083 HDT 14 F2 N

11 IT48mPit-68 GAS ANALYZER-DRYHELL 344 PD DELPHI Its SC112 YES 1035-1 IBT 18 F2 N

H IT48mPit-69 GAS ANALYZER-SUPPR CHH 344 PD DELPHI IFB SC112 YES 1035-1 DET 18 F2 18 ll IT48mRC-002 HYD REC 0tB UNIT 289 PD ATOHICS INT SC112 YES 54591-2 IET 14 F2 N

H IZ"

  • T 001 SUPPRESSICH POOL LEVEL 406 CD ROSEHOUNT SCO YES 127516 SAT 60+

F2 CS.HS H 1Z93mPT 003 DRYHELL PRESSURE 406 CD ROSEHOUNT SC98 YES 108025 IBT 60+

F2 CS HS H IZ93mPT 004

$UPP POOL PRESS 406 CD ROSfHOUNT SC40 YES 108025 HDT 60+

F2 CS,itS 11 J

IZ93*TE 110 RV092ACL DISCHARGE-IFT 406 CD ROSE!!OUNT PL28 IBT F4 H

D IZ93mTE 111 RV092BOE DISCHARGE-IFT 406 CD ROSEHOUNT PL28 teT F4 il D

1Z93mTE 112 RV092KG DISCHARGE-1FT 906 CD ROSEH0 TRIT PL28 IET F4 N

D 1Z93mTE 113 RV092FHJ DISCHARGE-1FT 406 CD ROSEll0UNT PL28 teT F4 H

D IZ93mTE 132 RV092ACL DISCHARGE-2FT 406 CD ROSEHOUllT PL28 tBT F2 N

D I

1Z93mTE 133 RV092BDE DISCHARGE-2FT 406 CD ROSEHOLAIT PL28 IBT F2 N

D 1Z93mTE 134 RV092KG DISCHARGE-2FT 406 CD ROSEHOUNT PLES tET F2 il D

1Z93mTE 135 RV092FHJ DISCHARGE-2FT 406 CD ROSEHOUNT PL28 HDT Ft N

D 1

.I 1

CS = COLD SHUT 008tl P = PIPE HOUNTED SBT=SIPELE FREQUENCY QUALIFICATION HILESTONES REVISIOtt 5 -DECE!l DER 1902 D = DUCT HOUtiTED PC =PRIllARY C0 TIT.

BIAXIAL TESTINS A zREEVALUATION CotFLETE DA :DYNAftIC ANALYSIS PL : PEDESTAL SC zSECCIDARY CONT.

B zREQUEST FOR QUAL OR BID ISSUED tt3TE: I:Li:2ER Iti F zFLOOR HOUllTED QP = QUALIFIED BY

/ = LOCATED ON CONT.

C =S/H REC 0tt!!EtDATI0tl TO LILCO

' TYPE 1111:S' COLL *28 IS I

}

HS zHOT STANDDY PIPING ANALYSIS HALL D = QUAL DOC RECEIVED CUAllTITY OF ITEl:5.

j teTalfULTI-FREQUENCY SA = STATIC AtL1 LYSIS N =tlEITHER CS OR HS E zHARDilARE HODIFICATION REQ'D

~

BIAXIAL TESTIts SAT =SillGLE FREQUENCY Z = PASSIVE ITEli F zQUAL DOC APVD & FILED HST=lfULTI-FliEQUENCY SIllGLE AXIAL TESTING ISQ'IT PAPER NOT G =SQRT PAPER C0t1PLETE SIllGLE AXIAL TESTIts REQ'D)

H = COPIES OF DOC TO DISTRIBUTI0tl i

k 1

l

r (3

(

V SHOREHAH UNIT 1 C3 LIST STONE 1 HE*STE2 EtGINEERING CORPORAT10tl RUti DATE 12/20/82 JOB HUtBER 11600 1-SORT CONTROL DUILDING CATEGORY I EQUIPitENT RUtt TIllE 13.20.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (220 ITDIS)

PAGE 1 HARK EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE SAFE CUAL d

HUlBER DESCRIPTION 10.

RESP VEtBOR ELEV ItiSP REPT llETH FREQ ilit!G S1i10:1 S TATU3 It21mTE-037 FN STH LINE TURB AREA 404 CD ROSEtt0HT 042 YES 2767 SAT 35, F4 CS.HS H

ID11mPtL-021 RBSBVS HONITORING PAHE 332 PD tNC 063 YES 45493-1 IET 13 F

ll H

ID11mPtL-022 RBSBVS 110NITORItG PANE 332 PD MC 043 YES 45493-1 HBT 13 F

fl H

1011mPit-025 CONT ROOH HONITOR PtL 332 PD tec 044 YES 45493-1 HBT 14 F2 H

li 1211mPtL-026 Cat (T ROOH HONITOR Pit 332 PD tetC 044 YES 45493-1 IET 14 F2 tl II ID11mPit-027 CONT RH VENT tt0 HIT PtL 332 PD tec 063 YES 45493-1 IET 13 F

18 il 1011mPtL-066 POST ACCOUNT tt0H 332 PD

'fC C63 YES 45493-1 IBT 14 F

(4 H

1011mPIL-067 POST ACCDriT H0HITORS 332 PD t0C 063 YES 45493-1 tBT 14 F

H H

1011mPit-068 POST ACCDr(T ll0NITORS 332 PD teC 063 YES 45493-1 IET 14 F

ti 11 1D11mPtt-049 POST ACCDHT HONITORS 332 PC tttC 063 YES 45493-1 IBT 14 F

tl H

1D11mPtL-080 RAD HON Pit 332 PD ttC 063 YES 4549T-1 tBT 6

F2 ft 11 1D11mPtL-117 RAD HON SYS Ite 475 PD HAHAN 063 F2 D

ID11mPtt-126 STA VENT HONITOR 475 PD HAHAtt 063 YES 16435 flDT 4

F ti tt 1D11mPtL-134 RB SVS ttDNITOR 475 PD HAHAN 113 fES 16435 FET 4

F fl it 1011mPtL-135 HICRoCotr FOR PtL126 475 PD HAHAN 063 YES 16435-A 11BT 19 F

H H

I ID11mPIL-137 HICROC0er FOR PtL134 475 PD HAHAN 063 YES 16435-A HDT 19 F

tt H

1011mRH-027 CR ATH N0ZZLE 332 PD t#C CB063 HBT F

CS.HS D/Z 1G11mLTS-642 THS6 LEVEL 473 CD DELAVAL 063 F

B 1G11mLTS-645 RB FLOOD LEVEL 473 CD DELAVAL 063 F2 B

1H11mHCS-01 HAIN CONTROL BOARD 120 CD RELIAPCE 063 YES 43331-1 SA/HST 16 F

CS.HS H

_1H11 mPtL-AC1 H2&O2 ANALEPST ACC SAH 125 CD RELIANCE 063 RCAP-001-0 SA 13 F

CS D

CS = COLD SHUT 00HN P = PIPE HOUNTED SGTzSINGLE FREQUENCY OUALIFICATICH HILESTottES REVISICH E -DECE!TER 1932 DA =0YHAtlIC AtlALYSIS

  • TEST ARTICLE BIAXIAL TESTItG A mREEVALUATION C0tlPLETE F = FLOOR tt0UNTED B = REQUEST FOR QUAL OR BID ISSUED tiOTE: I:U:CER Its its = HOT STANDBY QP = QUALIFIED BY H =NEITHER CS OR HS C =S/H RECO:CtEPIDATI0ft TO LILCO

' TYPE IfTt:G* COLL't::4 IS l

HDT=HULTI-FREQUENCY PIPIliG ArtALYSIS Z = PASSIVE ITEH D = QUAL DOC RECEIVED QUAtlTITY OF 11El:3.

BIAXIAL TESTIttG SA = STATIC AtlALYSIS (SQRT PAPER HOT E =HARDHARE llODIFICATI0tl REQ'O

.-MST=t1ULTI-FREQUEtiCY SAT = SINGLE FREQUENCY REQ'D)

F zQUAL DOC APVD & FILED l

SINGLE AXIAL TESTING SitiCLE AXIAL TESTING G zSQRT PAPER LO;tPLETE i

H = COPIES OF DOC TO DIfiRIBUTI0t:

i 4

i

)

e 4

~~

e-

=v-

-L---

--L-----

-ee----

-+

u

-L*-

O O

SHOREHAH 12 TIT 1 CB LIST STONE & HE!STE2 ENCIHEERING CORPORATIDH RUN DATE 12/20/02 JOB tAABER 11600 1-SORT CottTROL BUILDItk3 CATEGORY I EQUIPitENT Rutt TIttE 13.20.25 LILCD DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (220 ITEttS)

PAGE 2 HARN EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE SAFE OUAL NUtBER DESCRIPTI0tt NO.

RESP VEtBOR ELEV INSP REPT HETH FREQ ltTt*G SitTDil STATUS 1H11mPtL-AC2 H2SO2 ANALSPST ACC SAM 125 CD RELIANCE 063 RCAP-001-0 SA 13 F

CS B

1H11mPtL-BR1 BUFFER RELAY CAB 125 CD RELIANCE 044 YES 99AX400536 SA/HST 37 F

CS.!!S B

1H11mPit-HXP HISC CONTROL PANEL 125 CD RELIANCE 063 YES 99AX400590 SA/HST 17 F

CS.HS B

1H11mPtL-PCM PRI CONT HONITOR PANEL 125 CD RELIANCE 063 YES 99AX400666 SA/HST 14 F

N ti 2H11mPit-VC1 TB & HISC vet (T 125 CD RELIANCE 063 YES 99AX400536 SA/HST 17 F

CS D

1H11mPit-VC2 RB VENT 125 CD RELIANCE 063 YES 99AX400536 SA/HST 17 F

CS B

g IH21mPit-AX1 AUX RELAY 125 CD RELIANCE 044 YES 99AX400590 SA/HST 32 F

CS.HS D

1H21mPFL-AX2 AUX RELAY 125 CD RELIANCE 044 YES 99AX400590 SA/HST 32 F

CS.HS B

l 1H21mPit-AX3 AUX RELAY PANEL AX3 125 CD RELIANCE 063 YES AAI-131 SA/MST 22 F

CS.IIS B

j 1H21mPtL-AX5 AUX RELAY PANEL AXS 125 CD RELIANCE 063 YES AAI-131 SA/HST 22 F

CS.HS B

1

~

1H21mPit-AX6 AUX RELAY PANEL AX6 125 CD RELIANCE 063 YES AAI-131 SA/HST 22 F

CS.IIS D

1H21mPit-VX1 VENT AUX RELAY 125 CD REMANCE 044 YES 99AXO536-VX1 SA/HST 34 F

CS.HS B

1 IH21mPtL-VX2 VENT AUX RELAY 125 CD RELIANCE 044 YES 99AX0536-VX1 SA/HST 34 F

CS.HS 0

1H21mPtL-VX3 VEtiT AUX RELAY 125 CD RELIANCE 044 YES 99AX0536-VX1 SA/itST 23 F

CS.HS B

1H21mPPL-060 ELEC ANAL IttSTR RM 125 CD RELIANCE 044 YES 99AX400679 SA/IIST 33 F

CS f ts ti 1H43mHS003 FIRE DIT SH STA 319 ED P0HERS REG 044 YES 43812-1 IST 24 F3 CS.HS 14 1H43mHS006 FIRE DET SH STA 319 ED P0HERS REG 025 YES 43812-1 teT 24 F3 CS.Its H

1H43mPit-C01 CO2 DETEC PtL RELAY P1 238 PD RELIANCE 044 YES 44204-1 IST 17 F2 ll H

q lit 43.PflL-C02 CO2 SUPVR PIL BATTERY 238 PD RELIANCE 025 YES 44204-1 IST 17 F

tl H

1 IH43mPtL-CO3 CO2 SUPVR Pit "ATTRY R 238 PD RELIANCE 025 YES 44204-1 tBT 17 F

tt it

_ 1H43 aptt.-C04 CO2 SUPVR Pit BATTRY st 238 PD RELIANCE 025 YES 44204-1 HBT 17 F

fl H

CS = COLD SHUT 00144 P

PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTCtfES REVISION 5 -DECEl:SER 1982 DA DYtIAHIC ANE.YSIS

  • TEST ARTICLE BIAXIAL TESTING A rREEVALUATIO!4 C0l!PLETE F = FLOOR lt0UtiTED 8 zREQUEST FOR QUAL OR BID ISSUED tiOTE : IR!t.SER Ita HS = HOT STAT:CBY QP a QUALIFIED BY N zHEITHER CS OR HS C =S/H REC 0ftlEtDATI0tt TO LILCD
  • TYPE ttTI:G COLL *21 IS IBTattULTI-FREQUtilCY PIPING AftALYSIS Z sPASSIVE ITEH D zQUAL DOC RECEIVED QUAtITITY OF ITE!!S.

BIAXIAL TESTIrlG SA = STATIC ANALYSIS (SQRT PAPER NOT E =HARDHARE It00!FICATION REQ'D

_.itST=ttULTI-FREQUEtlCY SAT = SINGLE FREQUENCY REQ'D)

F = QUAL DOC APVD & FILED 4

sit 1GLE AXIAL TESTING SIriGLE AXIAL TESTING G zSQRT PAPER CottPLETE H aCOPIES OF DOC TO DIS (RIBUTI0tt i

I

E f

D SHOREHAH LRtIT 1 C3 LIST STONE & HEISTE3 ENGINEERING CORPORATION RUN DATE 12/20/62 JOB P4UtEER 11400 1-50RT CONTROL BUILDING CATEGORY I EQUIPtfENT RUti tit!E 13.20.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (220 ITEttS)

PAGE 3 4

HARH EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE SAFE CUAL NUtEER DESCRIPTION HO.

RESP VEtCOR ELEV INSP REPT ttETH FREQ HTHS SitTDil STATUS 1H43mPtL-C05 CO2 SWVR PtL DSL RH 1 238 PD RELIANCE 015 YES 44204-1 DET 17 F

H H

]

1H43ePit-C06 CO2 SUPVR PtL DSL RH 1 238 PD RELIANCE 015 YES 44204-1 fBT 17 F

N H

1H43mPtL-C07 CO2 SUPVR PtL DSL RH 1 238 PD RELIANCE 015 YES 44204-1 DET 17 F

H H

1H43aPtL-C08 CO2 SUPVR Pit EllER SHG 238 PD RELIANCE 025 YES 44204-1 HBT 17 F

fl H

1H43nPIL-C09 CO2 SUPVR Pit EHER SHG 238 PD RELIANCE 025 YES 44204-1 tBT 17 F

fl H

l IH43ePtL-C10 C02 SUPVR PtL EHER SHG 238 PD RELIANCE 025 YES 44204-1 HBT 17 F

H 11 1

1H43mPit-C11 CO2 SUPVR PFL COtPUTER 238 PD RELIANCE 044 YES 44204-1 fBT 17 F

N H

4 1H50mA0V062 RBSVS ?.,CRAC 423 CS FISHER 071 YES CD76-82 SAT 23 P2 CS.HS H

1H50mA0V043 RBSVS & CRAC 423 CD FISHER 071 YES CD74-82 SAT 23 P2 CS.HS H

i 1H50aA0V068 CHILLED HTR ISO BY 318 CD COPES VLLCAM 071 YES 10.3.115 SA 124 P2 CS.IIS H

1H50eA0V069 CHILLED HTR ISO BY 318 CD COPES VULCAM 075 YES 10.3.115 SA 124 P2 CS.HS H

1H50eFE-043 CHILLER DISCH 440 CD PERtRITIT CB072 YES tet(BB-220-CZC SA 60+

P2 CS r/Z l

j 11150mFT-043 HC-3 EVAP 406 CD ROSEHOHT 063 YES 127516 SBT 50 F2 CS ells H

litSOaFT-053 HC-4 EVAP 406 CD ROSEH0HT 043 YES 127516 SBT 50 F2 CS.HS H

4 Itt50 'CV025 CH SYSTEH A HAHEUP 318 CD COPES VLLCAN 072 YES 10.3.115 SA 124 P2 CS.HS H

1H50mi.3 002 ISOL BYP V A0V68A.49A 407 CD HAGilETROL 063 YES 43235-1 DET 17 F2 HS H lits 0mLS 025 CH SYSTEM A HAHEUP 407 CD HAGNETROL 063 YES 43235-1 IST 17 F2 HS H t

1H50aHOV031 CH RETURN 197 PD PRATT 071 YES D-0034-7 SA 394 P2 CS.HS H

1H50mHOV032 CH SUPPLY 197 PD PRATT 075 YES D-0034-7 SA 394 P2 CS etis H

1H50mHOV033 CH RETURH CROSSOVER 197 PD PRATT 071 YES D-0034-7 SA 394 P2 CS.itS H

i j

_ 1H50mHOV034 CH SUPPLY CROSSOVER 197 PD PRATT 075 YES D-0034-7 SA 394 P2 CS.HS H

l CS zCOLD SHUT DOHN P : PIPE HOUNTED SBTzSINGLE FREQUENCY QUALIFICATION HILEST0 TIES REVISICH 5 -DECEttER 19S2 j

DA :DYHAHIC ANALYSIS e TEST ARTICLE BIAXIAL TESTING A rREEVALUATION CollPLETE i

F sFLOOR HOUt4TED B zREQUEST FOR QUAL OR BID ISSUED FOTE: FUCER Jti i

HS = HOT STAtIDBY QP = OUALIFIED BY

'M zHEITHER CS OR HS C zS/H REcottitEt0ATI0tt TO LILCO

  • TYPE !!T!;S' CCLUl!!I IS j

IST=t1ULTI FREQUENCY PIPIttG ANALYSIS Z zPASSIVE ITEH D = QUAL DOC RECEIVED QUAtlTITY Or I1EttS.

BIAXIAL TESTIllG SA = STATIC AftALYSIS (SORT PAPER HOT E =HARDHARE tt0DIFICATION REQ'D l

THST=t1ULTI-FREQUEllCY SAT = SINGLE FREQUEtiCY REQ'D)

F = QUAL DOC APVD & FILED l

SINGLE AXIAL TESTIttG sit 1GLE AXIAL TESTING G sSQRT PAPER CollPLETE 1

H zCOPIES OF IeCC TO DISTRIBUTION T

e i

m O

p%

m C

(

U SHOREHAH UNIT 1 C3 LIST STCHE & HEBSTER EtEIrfEERING CORPORATION RUll DATE 12/20/82 JOB ttABER 11600 1-SORT CONTROL BUILDING CATEGORY I EQUIPitEHT RUtf TIttE 13.20.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (220 ITEllS)

PAGE 4 HARH EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE SAFE CUAL ttABER DESCRIPTION HO.

RESP VEte0R ELEV INSP REPT HETH FREQ HTitS SMTott STATUS 1H50mP-137 RBSVS & CRAC CH PUtFS 42G FD GOULD PLAFS 063 YES HE-324 SA 81 F2 CS.HS tl Ill50mP-138 RBSVS & CRAC CH PUtPS 62G PD GotA.D PUFFS 063 YES HE-326 SA 81 F2 CS.llS H

1H50mP-139 RBSVS & CRAC C0te PLAP 62H PD HORTHINGTON 063 YES DHA-000047 SA 31 F2 CS.IIS 11 1H50mP-140 RBSVS & CRAC COtm PUIP 62H PD HORTHINGTON 063 YES DHA-000047 SA 31 F2 CS.HS H

1H50mPCV019 RBSV H50 DIFF PRESS 310 CD FISHER CONTROL 063 YES 2-24451 SA/ SAT 25 P2 CS H

1H50mPDT019 RBSVS H50 DIF PR 404 CD ROSEH0HT 063 YES 127516 SBT 50 F2 CS.IIS H

1H50mPtg.-03 CHILLER cot { TROL PANEL 104 PD TRANE CD 063 YES NUC-102 SA 13 F2 CS.HS H

1H50mPte.-04 CHILLER CONTROL PANEL 106 PD TRAHE 063 YES ttJC-102 SA 13 F2 CS.HS H

1H50 MRV 391 CHILLED H2O SURGE TH88 191 CD L0tIERGAN 072 YES 502644 SA 60 P2 F

1H50mTE 089 RBSVS CHILLED HTR SYS 406 CD ROSEHOUNT 078 YES 2767 SAT 35+

F2 C3.IIS 11 1H50mTH-088 RBSVS & CRAC-SURGE TAN 114 PO BUFFALO TAtM 063 YES tM(BI-122-IA SA 45 F2 CS.HS 11 lits 0mHC-003 RBSVS & CRAC HTR CHILL 104 PD TRANE CO 043 YES HUC-102 SA 31 F2 C5.HS ll Ill50ml4C-004 RBSYS & CRAC HTR CHOLL 106 PD TRANE CO 043 YES HUC-102 SA 31 F2 CS.HS H

1H11mHOV031 2ND STAGE REHEAT STH 88V PD VELAN 051 YES SR-6262 SA/ SAT 33+

P2 HS H IN11mi10V034 HISC STH FROH HOR ISO 88V PD VELAN 051 YES SR-6262 SA/ SAT 33+

P 11 3 H i'

1H11mHOV041 AUXILIARY STEAH SUPPLY 88V PD VELAN 051 YES SR-6181 SA/ SAT 33+

P CS H

i IP41mA0V016 DIESEL HX E-13A OUTLET 423 CD FISHER 075 YES CD76-82 SA 23 P3 CS H

IP41*FE 018 OUTLET DIESEL HX E-13A 440 CD PERHUTIT CB027 YES tM(BI 220-CZC SA 33+

P3 CS F/Z

}

IP41mFE 054 Core HC-3 RETURN 440 CD PERHUTIT CB069 YES PM(B) 220-CZC SA 33+

P2 CS.its F/Z i

i IP41mFE 059 Core HC-4 IHLET 440 CD PERHUTIT CB072 YES tel(B) 220-CZC SA 33+

P2 CS ells F/Z j

_ 1P41mFT 054 HC-3 CC'm NTR IN 404 CD 'ROSEHONT 063 YES 127516 IET 60+

F2 CS.l:S H

j CS = COLD SHUT DOHN.

P : PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTO4ES REVISION 5 -DECEt:2ER 1902 DA :DYHAHIC AHALYSIS.

  • TEST ARTICLE BIAXIAL TESTING A mREEVALUATION CollPLETE l

F = FLOOR ltOUNTED B zREQUEST FOR QUAL OR BID ISSUED tioiE t:U:CER I?l l

HS zit0T STAtlDBY QP a QUALIFIED BY H zHEITHER CS OR HS C zS/H REC 0f 01Et!DATION TO LILCO

' TYPE HTt:S' COLT':sfl IS j

fBTzifULTI-FRZQUENCY PIPING AttALYSIS Z = PASSIVE ITEM D mOUAL 00C R[CEIVED QUAtITITY CF ITEMS.

i BIAXIAL TESTIts SA zSTATIC AtlALYSIS (SQRT PAPER HOT E zHARDHARE HODIFICATION REQ'O I

IHST=HULTI-FREQUEt:CY SATzSINGLE FREQUENCY REQ'D)

F = QUAL DOC APVD & FILED

, SINGLE AXIAL TESTING S!!GLE AXIAL TESTING G =SQRT PAPER CollPLETE H zCOPIES OF DOC TO DISTRIBUTION i

e i

s

1 V

O

\\

\\j s

SHOREHAN LR4IT 1 C3 LIST ST0tlE & HEBSTE2 ENGINEE%ING CORPORATION RUN DATE 12/20/e2 JOB iM1BER 11600 1-SORT C0tiTROL BUILDING CATEGORY I EQUIPitENT RUN TIltE 13.20.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (220 ITEtts)

PAGE 5 HARK EQUIPHEtIT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE SAFE CU*L NUIEER DESCRIPTION HO.

RESP vet 00R ELEV IllSP REPT HETH FREQ llTIG SitTDie STATUS IP41mFT 059 HC-4 Cote HTR IN 406 CD ROSEH0HT 063 YES 127516 HBT 60+

F2 CS ells H IP41mtt0V036A VT CHILL HTR SPLY 150L 197 PD PRATT 012 YES D-0034-3 SA 33+

P CS.HS H

IP41mHOV036B VT CHILL HTR SPLY ISOL 197 PD PRATT 012 YES D-0034-3 SA 33+

P C3.IIS H

IP41ml10V036C VT CHILL NT5t SPLY ISOL 197 PD PRATT 050 YES D-0034-4 SA 297 P

CS ells H

IP41mPS 008 SUCTION 1H50mP-1398 348 CD ASCO 063 YES 178 SAT 50+

F2 CS.HS 11 1'

IP41mPS 009 SUCTION IH50mP-1408 348 CD ASCO 063 YES 178 SAT 50+

F2 CS.HS H

j IP41 MRV 019 OUTLET DIESEL HX-13 191 CD LONERGAN 028 YES 502644 SA 60 P3 F

IP41 MRV 064 CNTRL RH & RBSVS HC-3 191 CD L0t4ERGAN 072 YES 502444 SA 60 P2 HS H

IP41 MRV 065 CNTRL RH & RBSVS HC-48 191 CD LONERGAN 072 YES 502644 SA 60 P2 HS H

IP41mTCV055 CNTRL RH & RBSVS HC-3 310 CD FISHER CONT.

063

'YES CD76-20 SA 40 P6 CS.HS H

IP41mTCV060 CNTRL RH & RESVS HC-4 310 CD FISHER CONT.

063 YES CD76-20 SA 40 P6 CS.11S H

I 1741mTE 055 Ct4TRL RH & RBSVS HC-3 406 CD ROSEl10UNT 068 YES 2767 SAT 35+

F2 CS.IIS H

i IP41mTE 060 CNTRL RH & RBSVS HC-4 406 CD ROSEHOUNT 068 YES 2767 SAT 35+

F2 CS.tlS 11 1R22mSIG-101 4.16HV EHER BUS 101 39 ED GEN ELEC CO 025 YES 300-91059

,DA/ SAT 8

F C3 HS H 1

1R22mSilG-102 4.16HV EHER BUS 102 39 ED GEN ELEC CO 025 YES 300-91059 DA/ SAT 8

F CS.HS H

}

1R22mSHG-103 4.16HV EHER BUS 103 39 ED GEN ELEC CO 025 YES 300-91059 DA/ SAT 8

F CS ells H 1R23mPtL-001 480V LOAD RESET PANEL 1 125 CD RELIANCE 025 YES AAl-125 SA/ SAT 24 F

CS tis 0

j 1R23mPtL-002 480V LOAD RESET PAtlEL2 125 CD RELIANCE 025 YES AAl-125 SA/ SAT 24 F

C3 HS B

IR23aPtL-003 480V LOAD RESET PANEL 3 125 CD RELIANCE 025 YES AAl-125 SA/ SAT 24 F

CS.HS D

1R23mSIIG-111 480V EffER SHGR BUS 111 95 ED ITE 025 YES 33-48359 HBT 5

F CS.HS tl

_ 1R23mSliG-112 480V EttER SHGR BUS 112 95 ED ITE 025 YES 33-48359 fBT 5

F CS.lis 11 J

CS = COLD SHUT 00 Hit P = PIPE It0UNTED SBT= SINGLE FREQUENCY QUALIFICATION HILEST0t4ES REVISION 5 -DECEff0ER 1902

}

DA :DYilAllIC AtlALYSIS

  • TEST ARTICLE BIAXIAL TESTING A = REEVALUATION COtlPLETE F =FLOCR tt0UtiTED B = REQUEST FOR QUAL OR DID ISSUED HOTE: fiUt:::ER I:4 HS = HOT STAtOBY QP u QUALIFIED BY H =llEITHER CS OR HS C =S/H REC 0t3tEtOATI0tl TO LILCO

' TYPE IITIG' COLLua IS ItST=HULTI-FREQUEllCY PIPItG Af4ALYSIS Z = PASSIVE ITEtt O = QUAL DOC RECEIVED QUA!ITITY OF ITElG.

BIAXIAL TESTING SA = STATIC At4ALYSIS (SQRT PAPER NOT E =l(ARDHARE HODIFICATION REQ'O HST=ltULTI-FREQUEttCY SAT =SIttGLE FREQUENCY REQ'D)

F = QUAL 00C APVD & FILED sit 4GLE AXIAL TESTItG SIllGLE AXIAL TESTING G = SORT PAPER CotFLETE H = COPIES OF DOC TO DISTRIBUTION 5

i

0 SHOREHAH UNIT 1 C3 LIST STONE & HEBSTE2 ENGINEEZING CORPORATION RUN DATE 12/20/C2 JOB NUttBER 11400 1-SORT CONTROL BUILDING CATEGORY I EQUIPHEhr RUH TIttE 13.20.25 LILCO DOCHET S0-322 ACTIVE BOP QUALIFICATION LEVEL (220 ITEHS)

PAGE 4 ttARN EQUIPHENT SPEC DIV.

8LDG AVAIL QUAL QUAL TYPE SAFE QUAL lARIDER DESCRIPTION NO.

RESP VEtSOR ELEV INSP REPT HETH FREQ IITiiG S13TDH STATUS li23mSHG-113 480V EHER SHGR BUS 113 95 ED ITE 025 YES 33-48359 DET 5

F CS.HS H

1R24mtICC1115 HOTOR CONT CNTR BUS 1 115 ED SQUARE D CO 025 YES 108-1.01 L2 tBT 4

F CS.HS H

1R24mitCC1114 HOTOR CONT CNTR BUS 1 115 ED SQUARE D CO 025 YES 108-1.01 L2 tBT 4

F CS.HS tl 1R24mitCC1125 HOTOR CONT CNTR. BUS 1 115 ED SQUARE D CO 025 YES 108-1.01 L2 IBT 4

F CS.HS H

1:24mitCC1126 HOTOR CONT CNTR. BUS 1 115 ED SQUARE D CD 025 YES 108-1.01 L2 tBT 4

F CS.HS H-IR24mitCC1133 HOTCR CONT CNTR BUS 1 115 ED SQUARE D CO 025 YES 108-1.01 L2 IET 4

F CS.HS H

1R24mHCC1134 HOTOR CONT CNTR. BUS 1 115 ED SQUARE D CO 025 YES 108-1.01 L2 fBT 4

F C3 IIS H

1235mPtL-B1 EHER 120V PtL B1-REL R 124 ED SYSTEH CONT 044 YES 15074 SAT 21 F

CS.fl3 H

1 35*PtL-83 EHER 120/240V PANEL 124 ED SYSTEH CONT 020 YES 15074 SAT 21 F

CS.HS H

1235mPit-R1 EHER 120V Pit R1-REL R 124 ED 3YSTEM CONT 044 YEft 15074 SAT 21 F

C5.flS H

1R35mPtL-R3 EHER 120/240V PANEL 124 ED SYSTEM CONT 020 YES 15074 SAT 21 F

C5.Ils H

1335mPit-01 EHER 120V PtL 01-REL R 124 ED SYS1EM CONT 044 YES 15074 SAT 21 F

CS.llS tl IR35mPit.-02 EHER 120/240V PANEL 124 ED SYSTEH CONT 020 YES 15074 SAT 21 F

CS.HS H

1R35mT-B1 XFtsi-EHER 120V PtL B1 248 FD HAGNETICS 025 YES 43424-1 HBT 9

F CS.HS F

]

1R35mT-83 XttFR-EHER 120V Ptt 83 248 ED HAGNETICS 025 YES 43424-1 IBT 9

F CS.tlS F

1R35mT-R1 XFitR-EHER 120V PtL R1 248 ED HAGNETICS 025 YES 43424-1 ItBT 9

F CS.HS F

1R35mT-R3 XIlFR-EHER 120V PtL R3 248 ED HAGNETICS 025 YES 43424-1 PET 9

F CS elts F

1R35mT-01 XFitR-EHER 120V PFL 01 248 ED HAGNETICS 025 YES 43424-1 IST 9

F CS.IIS F

I 1R35mT-02 XHFR-EHER 120V PtL 02 248 ED HAGNETICS 025 YES 43424-1 tBT 9

F CS.HS F

1R35mT-201 XFR-HTR SPACE HTR-BUS 248 ED HAGNETICS 025 YES 43424-1 IET 9

F C3.HS F

_1R35mT-202 XFR-HTR SPACE HTR-BUS 248 ED HAGNETICS 025 YES 43424-1 IBT 9

F C5.l:S F

l l

CS

  • COLD SHUT DOIRt P = PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILEST0tlES REVISION 5 -DECE!:3:R 1902 j

DA :DYHAllIC AfiALYSIS e TEST ARTICLE BIAXIAL TESTIllG A zREEVALUATION Cots)LCTE J

F FLOOR H0lkiTED 8 sREQUEST FOR QUAL OR BID ISSUED HOTEt i;L't"/,ER Its H3 = HOT STAfBBY QP s QUALIFIED BY H zHEITHER CS OR HS C zS/H REC 0fttEtiDATION TO LILCO

' TYPE liit:S' COtttti IS IIST=HULTI-FREQUEtiCY PIPING ANALYSIS Z = PASSIVE ITEM D zQUAL ECC RECEIVED QUAttTITY CF ITEllS.

i BIAXIAL TESTI 4G SA = STATIC ANALYSIS (SQRT PAPER HOT E zHARDilnRE tt0DIFICATION REQ'D THST=HULTI-FREQUEffCY SATsSIttGLE FREQUENCY REQ'D)

F zQUAL 00C APVD & FILED l

SINGLE AXIAL TESTIt4G SillGLE AXIAL TESTING G sSQRT PAPER COtPLETE j

H aCOPIES OF DOC TO DISTRIBUTION i

I

_. - -. -. ~.. -..

SHOREHAH LR4IT 1 C3 LIST STONE & HESSTEJB ENGINEERING CORPORATION RUN DATE 12/20/82 4

1 JOB HulBER 11600 1-50RT CONTROL BUILDItG CATEGORY I EQUIPitENT RUN TIliE 13.20.25 LILCS DOCHET 50-322 ACTIVE BOP QUALIFICATI0H LEVEL (220 ITEMS)

PAGE 7 HARN EQUIPHENT SPEC DIV.

SLDG AVAIL QUAL QUAL TYPE SAFE QUAL IRABER DESCRIPTION HO.

RESP VERDOR ELEV INSP REPT HETH FREQ HTHG SitTCtl STATUS 133 203 XFR-HTR SPACE HTR-BUS 248 EO HAGNETICS 025 YES 43424-1 DBT 9

F CS.HS F

l 1242mBA-Al 12SVOLT BATTERY lle ED GOLA.D INC 025 YES 42795 teT 40+

F CS.HS H

i 1R42mBA-B1 125 VOLT BATTERY lle ED GOLA.D INC 025 YES 92795 PST 40+

F CS.HS H

1R42mBA-C1 125 VOLT BATTERY lle ED GOLLO INC 025 YES 42795 IST 40+

F CS.HS li 1R42mBC-Al 125 VOLT BATTERY CHARGE 118 ED SOLIDSTATE 025 YES 3/29/74 SAT e

F CS lfS H 1;42mBC-81 125 VOLT BATTERY CHARGE 118 ED SOLIDSTATE 025 YES 3/29/76 SAT 8

F CS.HS H.

j 1R42nBC-C1 125 VOLT BATTERY CHARGE 118 ED,SOLIDSTATE 025 YES 3/29/76 SAT 8

F CS.l:S le l

1%42aPit-Al 125 VOC DIST PANEL BUS 124 ED SYSTEH CCHT 025 YES 15074 SAT 21 F

CS.HS 11 IR42mPit-A2 125 VDC DIST PANEL BUS 124 ED SYSTEM CONT 844 YES 15074 SAT 21 F

CS.HS H

j 1R42mPit-81 125 VDC DIST PANEL BUS 124 ED SYSTEH CONT 025 YES 15074 SAT 21 F

CS.HS H

1R42mPtL-82 125 VDC DIST PANEL BUS 124 ED SYSTEH CONT 044 YES 15074e SAT 21 F

CS.}ts H

l j

1%42mPtt-C1 125 VDC DIST PANEL BUS 124 ED SYSTEH CONT 025 YES 15074 SAT 21 F

CS.HS H

l II42mPtt-C4 125 VDC DST Ptt-BLN-BS 124 ED SYSTEM CONT 025 YES 15074 SAT 21 F

CS lis H i

i II42mSHG-Al 125 VJC SHG BATTERY BU 95 ED ITE 025 YES 33-51266 teT 5

F CS.HS H

1 1542mSHG-B1 125 VDC SHG PATTERY BU 95 ED ITE 025 YES 33-51266 teT 5

F CS.liS H

1R42mSHG-C1 125 VDC SH3 BATTERY BU 95 ED ITE 025 YES 33-51266 teT 5

F CS.HS H

l 1%43mG-101 EHER DIESEL GENERATOR 89 CD DE LAVAL 025 YES 11001 DA 4

FIS CS.HS H

1R43mG-102 EHER DIESEL GENERATOR 89 ED DE LAVAL 025 YES 11001 SAT 4

F18 CSills H

1R43eG-103 EHER DIESEL GENERATOR 49 ED DE LAVAL 025 YES 11001 SAT 4

FI6 CS HS H 1R93mLS 004 FUEL OIL AUX DAY TN 407 CD HAGNETROL 022 YES 43235-1 SAT 17 F3 tt H

_ 1R43mLS 007 FUEL OIL AUX DAY TN 407 CD HAGNETROL 022 YES 43235-1 SAT 17 F3 14 la CS = COLD SHUT 00604 P

PIPE HOUNTED SBTsSINGLE FREQUENCY QUALIFICATION HILESTONES REVISION 5 -0ECEICER 1932 0A DYHAHIC ANALYSIS

  • TEST ARTICLE BIAXIAL TESTING A mREEVALUATI0tt ColtPLETE F = FLOOR HOLAITED B zREQUEST FOR QUAL OR BID ISSUED NOTE flu!SER Itt HS zHOT STAteBY QP z QUALIFIED BY H zHEITHER CS OR HS C zS/H REcolBIENDATION TO LILCO

'TYP2 HTt:G' CCLU'rt IS 12T=HULTI-FREQUENCY PIPING At4ALYSIS Z = PASSIVE ITEH D squAL DCC RECEIVED QUArtTITY OF ITEl:S.

BIAXIAL TESTING SA = STATIC AHALYSIS (SQRT PAPER HOT E zHARDilARE HODIFICATICH REQ'D

{

HST HULTI-FREQUEtlCY SAT =SIriGLE FREQUENCY REQ'DI F zQUAL 00C APVD & FILED SINGLE AXIAL TESTING SIllGLE AXIAL TESTING G zSQRT PAPER C0tW'LETE l

H zCOPIES OF DOC TO DISTRIBUTION i

I A

l SHCREHAM l#4IT 1 C3 LIST STONE & HE;STE3 Er2INEE?ING CORPORATION KUN DATE 12/20/02 l

JOB HUISER 11600 1-SORT LCHTROL BUILDING CATEGORY I EQUIPilENT RUtf tit!E 13.20.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (220 ITEttSI PACE 8

)

HARN EQUIPHENT SPEC OIV.

BLOG AVAIL QUAL QUAL TYPE SAFE CUAL NUHBER DESCRIPTION HO.

RESP VEtOOR ELEV INSP REPT HETH FREQ llTilG StlTDH STATUS 1R43mTM-135 FUEL OIL DAY 114 PO BUFFALO tat #(

044 YES tet(BB-134-IA SA 27 F3 CS li 1R81mT-012 HT TRACIts TRANSFt5t 248 ED HAGNETICS 025 43424-1 teT 9

F2 CS.HS F

IT48mPtA.-ACH PC ATH CNTRL 125 CD RELIANCE 063 YES 99AX400600 SA/ SAT 19 F

fl B

l IT48mPit-A2 I!YD RECOlBINER CONT CA 289 PD ATOHICS INT 063 YES 54591-4 teT 6

F2 H

H 1T48mRN-25 HYDRO REC 0tB CONT CABI 344 ED DELPHI Its 063 YES 1035-5 SA/ SAT 29 F2 H

i l

1T48mRH-26 HYDRO REC 0tB CONT CABI 344 ED DELPHI Its 063 YES 1035-5 SA/ SAT 29 F2 H

H

\\

1X41mACU-19 C0tF, RELAY 8EH SHGR RH 240 PO BAHNSON CO 044 YES A-47-75-01 SA 39 F2 C3.HS tt IX41mDIFF FIRE DA?PERS 54 PD AIR BALANCE 044 YES AB1-SH-009 SAT 9+

F30 CS. TIS H

IX41mFN-029 RELAY &EHER SHGR RET FH 270 PO BUFFALO FORGE 053 YES 745-11139 SA 26 F2 CS.It3 H

f j

IX41mFN-039 CR CHILL EQUIP RH EXH 270 PO BUFFALO FORGE 067 YES 745-11140A SA S7 F2 CS.HS H

l IX41mFH-072 BATTERY RH VENTILATION 270 PO BUFFALO FORGE 035 YES 745-11140C SA 105 F3 CS el!S H

i IX41mFS 013 ACU-14 AIR FLOH 319 ED P0HERS REG 031 YES 43812-1 HBT 24 F2 CS.IIS H

l IX41mFS 017 FH-29 AIR FLON 319 ED PONERS REG 044 YES 43812-1 teT 24 F2 CS elf S H IX41stlE 021 ACU-14 COOLING CNTRL 319 ED P0HERS REG 044 YES 43812-1 t2T 24 F2 CS.HS H

{

1X41 SHIT 021' ACU-14 C00 Lits CNTRL 319 ED POHERS REG 049 YES 43812-1 teT 24 F2 CS liS II 1X41mH00031 FN-039 OUTD00P AIR 319 ED P0HERS REG 063 YES 43812-1 HBT 24 F2 C3.HS tl

)

IX41stt00032 FH-039 EXHAUST AIR 319 ED P0HERS REG 064 YES 44540-1 HBT 27 F2 CS.HS ll j

1X41*lt00035 ACU-144 DISCHARGE AIR 319 ED P0HERS REG 044 YES 43812-1 tBT 24 F2 CS.IIS II 1X41 mil 00036 OH FAH EH-29At B 319 ED P0HERS REG 044 YES 43812-1 tBT 24 F2 CS.HS H

1X41st00039 FN-72 OUTDOOR AIR 319 ED P0HERS REG 037 YES 44057-1 HDT 21 F3 C3.ttS tl i

_1X41mit00040 FN-72 EXHAUST AIR 319 ED P0HERS REG 041 YES 44057-1 teT 21 F3 CS.HS H

E i

CS = COLD SHUT DOHN P

  • PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HJLEST0ftES REVISICH 5 -DECE!!CER 19E2 DA =DYHAllIC AtlALYSIS
  • TEST ARTICLE BIAXIAL TESTING A zREEVALUATIOtt CottPLETE F zFLOOR HOUNTED D mREQUEST FOR QUAL OR BID ISSUED NOTE: ItUCER Ill i

HS HOT STAtOBY QP = QUALIFIED BY H zHEITHER CS OR HS C zS/H REC 0!3IETOATI0tl TO LILCO

' TYPE ttitG' CCLttel IS I

fBTattULTI-FREQUENCY PIPING ANALYSIS Z aPASSIVE ITEM D xQUAL DOC RECEIVED CUAtlTITY OF ITEt:3.

BIAXIAL TESTING SA zSTATIC AtlALYSIS iSQRT PAPER HOT E zHAR0l!N?E tt0DIFICATION REQ'D THST:HULTI-FREQt'EtiCY SAT =SIHGLE FREQUENCY REQ'D)

F = QUAL DOC APVD & FILED i

SINGLE AXIAL TESTING SIttGLE AXIAL TESTING G zSQRT PAPER C0t!PLCTE

]

H aCOPIES OF DOC TO DISTRIBUTION I

A O

OU t

SHOREHAH UNIT 1 CB LIST STONE & HEBSTER ENGINEERING CORPORATION RUN DATE 12/20/02 JOB NUlBER 11400 1-SORT CONTROL EUILDING CATEGORY I EQUIPitEtlT RUti TIllE 13.20.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (220 ITEttS)

PAGE 9 3

HARN EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE SAFE QUAL.

FAJtBER CESCRIPTION NO.

RESP VEFOOR ELEV IttSP REPT HFTH FREQ HTilG SillDil STATUS 1X41mH00041 FN-72 RETURN AIR 319 ED P0HERS REG 035 YES 44057-1 FBT 21 F3 CS.HS H

IX41mHOD059 RELAY & CN TR RH TEW 319 le PCHERS REG 044 YES 44057-1 HBT 21 F2 CS.HS H

IX41mPFLVC16 VENT CONTROL PANEL 319 ED P0HERS REG 025 YES 1001-6 SA/ SAT 24 F

H H

i 1X41mPtt.VC17 VENT CONTROL PANEL 319 ED P0HERS REG Oc5 YES 1901-4 SA/ SAT 24 F

N H

1X41mPtt.VC18 VENT CONTROL PANEL 319 ED P0HERS REG 025 YES 1001-4 SA/ SAT 24 F

N H

)

1X41mPtLVC19 VENT CONTROL PANEL 319 ED PCHERS REG 025 YES 1001-6 SA/ SAT 24 F

CS.HS H

IX41mPit.VC20 VENT COtiTROL PANEL 319 ED P0HERS REG 025 YES 1001-6 SA/ SAT 24 F

CS.HS H

IX41mPtLVC21 VENT CONTROL PANEL 319 ED P0HERS REG 044 YES 1001-6 SA/ SAT 24 F

CS.HS H

1X41mTCV021 ACU-14 COOLING COIL 310 CD FISHER C0 tit.

053 YES 2-24451 SA 25 P2 CS H

I IX41mTE 018 FN-72 DAtFER CONTROL 319 ED Pot 4ERS REG 030 YES 43812-1 HBT 24 F3 CS.HS H

I IX41mTE 021 ACU-14 COOLING CONT 406 CD ROSEHOUNT 044 YES 2747 SAT 35+

F2 CS.HS H

l IX41mTIS031 FN-39 CONTROL 319 ED PCHERS REG 048 YES 43812-1 fBT 24 F2 CS.HS H

4 IX41mTT-001 RH TE W Ire 319 ED P0HERS REG 025 YES 43812-1 PET 24 F2 tl H

IX41mTT-002 RH TEW ItB 319 ED PCHERS REG 025 YES 43812-1 tBT 24 F2 11 H

IX41mTT-003 RH TEN Its 319 ED P0HERS REG 025 YES 43812-1 IST 24 F2 81 H

IX41mTT-004 RH TEtP Ite 319 ED P0HERS REG 044 YES 43812-1 FST 24 F2 ti et IX41mTT-005 RH TEtP Its 319 ED P0HERS REG 04'4 YES 43812-1 IST 24 F2 N

H IX41mTT-004 CHILLER EQUIP RH TEtr 319 ED PONERS REG 048 YES 43812-1 DET 24 F2 H

H IX41mTT-007 BAT RH TElp 319 ED P0HERS REG 039 YES 43812-1 IBT 24 F2 tl H

IX41mTT-009 C0tFUTER Rtl TEW 319 ED P0HERS REG 044 YES 43812-1 HBT 24 F2 t4 H

,1X60ef tf-028 DIESEL GEN RH SUPPLY F 270 PD BUFFALO FORGE 040 YES 745-11138 SA 20 F3 C3.HS tt CS zCOLD SHUT DOHN P : PIPE HOUNTED SBTsSINGLE FREQUENCY QUALIFICATION HILESTot4ES REVISIcti 5 -DECEtr.ER 1932 l

DA =0YNAllIC ANALYSIS a TEST ARTICLE BIAXIAL TESTING A rREEVALUATIOli CotPLETE F zFLOOR HOUt(TED B zREQUEST FOR QUAL 03 BID ISSUED 140TE tEER Itt i

HS = HOT STANDBY QP z QUALIFIED BY N zHEITHER CS OR HS C zS/H REC 0tillEllDATICH TO LILCO

' TYPE ttTI:G' Cettui IS t3TztRA.TI-FREQUENCY PIPING At4ALYSIS Z zPASSIVE ITEM D = QUAL DOC RECEIVED QUAliTITY OF ITE!!S.

I BIAXIAL TEST 1tlG SA zSTATIC AttALYSIS (SQRT PAPER NOT E zHARDHARE lt0DIFICATION REQ'D

' C HSTzitULTI-FREQUEtlCY SATzSIttGLE FREQUENCY REQ'D)

F zQUAL DOC APVD & FILED I

SINGLE AXIAL TESTING SINGLE AXIAL TESTING G zSQRT PAPER C0!FLETE H

  • COPIES OF DOC TO DISTRIBUTION i

l i

SHOREHAH UNIT 1 C3 LIST STONE & HELSTE2 ENGINEERING CORPORATION RUN DATE 12/20/02 JOB NUlBER 11400 1-SORT CONTROL BUILDING CATEGORY I EQUIPflENT RUH TIHE 13.20.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (220 ITEMS)

PACE 10 HARM EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE SAFE CUAL NUlBER DESCRIPTION HO.

RESP VEte0R ELEV INSP REPT HETH FREQ HTNG StiTDil STATUS 1X60mtIDD031 FN-28 OUTDOOR AIR 319 ED POHERS REG 038 YES 44057-1 teT 21 F3 CS 1X40mH00032 FN-39 HOT DAIFER 319 ED P0HERS RES 030 YES 44057-1 PET 21 F3 CS ll IX60mH00033 FN-28 RETURN AIR 319 ED P0HERS REG 038 YES 44057-1 HBT 21 F3 CS H

i IX40mPit.VC13 VENT CONTROL PANEL 317 ED P0HERS REG 025 YES 1001-4 SA/ SAT 24 F

CS.HS h

IX40mPt0.VC14 VENT CONTROL PANEL 319 ED P0HERS REG 025 YES 2001-6 SA/ SAT 24 F

CS.HS H

IE60mPit.VC15 VENT CONTROL PAtt~L 319 ED P0HERS REG 025 YES 1001-6 SA/ SAT 24 F

CS.HS H

IX61mACU-07 CONTROL ROOH A/C LRtITS 240 PD BAHNSON CD 043 YES A-47-75-01 SA 39 F2 CS ells H

IX61mAOD037 CNTRL RH ISOL 319 ED P0HERS REG 043 YES 44540-1 DET 27 F3 CS.HS H

1X61mA0V034 CHTRL RH ISOL 111 PD FISHER 043 YES CD75-35 SA/ SAT 17+

P2 CS H

IX61mA0V038 CNTRL RH ISOL 111 PD FISHER 073 YES CD75-35 SA/ SAT 21 P2 CS H

1X61mAOV039 CHTRL RH ISOL 111 PD FISHER 043 YES CD75-35 SA/ SAT 21 P2 CS H

I 1X41mDIFF FIRE DAtPERS 54 PD AIR BALANCE 063 YES AB1-SH-009 SAT 9+

F8 CS.HS H

I IX61mFLT-02 CRAC FILTER TRAINS 105 PD FARR CO 043 YES D-56302 SA/ SAT 17 F2 CS.HS H

I i

IX61mFN-025 CONTROL ROOH BOOSTER F 102 PO BUFFALO FORGE 043 YES 745-4234A SA 27 F2 CS.HS H

1X61mFS 011 FN-25 CNTRL 319 ED POHERS REG 043 YES 43812-1 teT 24 F2 CS lls H IX41mFS 012 ACU-7 AIR FLOH 319 ED P0HERS REG 063 YES 43812-1 DET 24 F3 CS.HS H

IX61mHS 038 IX61mAOV038 CONTROL 319 ED P0HERS REG 064 YES 43812-1 IST 24 F2 CS ells H IX41mHE-021 ACU-7 CNTRL 319 ED P0HERS REG 043 YES 43812-1 IBT 24 F2 CS.HS H

I j

IX61mH00033 FN-25 DISCH AIR 319 ED P0HERS REG 063 YES 44540-1 IST 27 F2 N

li j

i IX61mH00034 ACU-7 DISCHARGE AIR 319 ED P0HERS RES 043 YES 43812-1 IST 24 F2 CS.Ils it

_ 1X61ml10V031 CNTRL RH ISOL 111 PD FISHER 063 YES CD75-35 SA/ SAT 22+

P2 CS H

l CS zCOLD SHUT DO W P = PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVISICH 5 -DEC[tCER 198:'

l DA =DYNAHIC ANALYSIS a TEST ARTICLE BIAXIAL TESTING A mREEVALUATION CollPLETE F = FLOOR HOUNTED B sREQUEST FOR QUAL OR BID ISSUED liOTE: tiU:CR Ill

}

HS zHOT STAllDBY QP a QUALIFIED BY H zHEITHER CS OR HS C =S/H REcolOIEllDATION TO LILCO

' TYPE HTt:S' COLU::tl IS j

teT=lluLTI-FREQUENCY PIPING ANALYSIS Z PASSIVE ITEM D = QUAL DOC RECEIVED QUANTITY OF ITEltS.

BIAXIAL TESTING SA zSTATIC AHALYSIS (SQRT PAPER HDT E =HARGHARE HODIFICATION REQ'O l

THST=lluLTI-FREQUENCY SAT = SINGLE FREQUEHCY REQ'D)

F = QUAL DOC APVD & FILED 4

' SIllGLE AXIAL TESTING FINGLE AXIAL TESTING G zSQRT PAPER COllPLETE i

H zCOPIES OF DOC TO r.171PIDUTION i

i O

'J q

SHOREHAH 4.RtIT 1 C3 LIST STONE & HEESTE2 ENGINEERING CORPORATION RUtt DATC 12/20/82 JOB hut 1BER 11600 1-50RT CorITROL BUILDING CATEGORY I EQUIPitEliT Ruit TIltE 13.20.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (220 ITEttS)

PAGE 11 HARN EQUIPHENT SPEC DIV.

BLDG AVAIL QUAL QUAL TYPE SAFE Cut.L NUttBER DESCRIPTION 140. RESP VEtOOR ELEV IttSP REPT HETH FREQ HTiiG CITCt1 STATUS 1X61mHOV032 CNTRL Rtt ISOL 111 PD FISHER 063 YES CD75-35 SA/ SAT 22+

P2 CS H

IX61mTCV021 ACU-7A COOLING UNIT 310 CD FISHER CONT.

071 YES 2-24451 SA 25 P2 CS H

IX41mTE 021 ACU COOLING C0ffT 404 CD ROSEHOUtiT 047 YES 2767 SAT 35+

F2 CS.HS H

IZ95mENCSX1 SXS EtCLOSURE 125 CD RELIANCE 044 99AX400827 SA 61 F

B 1Z95mENCSX2 SXS EHCLOSURE 125 CD RELIANCE 044 99AX400827 SA 61

/

B 1Z15mEtCSX3 SXS EHCLOSURE 125 CD RELIANCE 044 99AX400827 SA 61 F

B 2Z95mENCSX4 SXS EfCLOSURE 125 CD RELIANCE 044 97AX400827 SA 61 F

B 1Z97aPtLERI HULTIPLEX CAB 125 CD RELIANCE 044 99AX401437 SA 14 F

D 1Z97aPFLER2 HULTIPLEX CAB 125 CD RELIANCE 044 99AX401437 SA 14 F

D 1Z97mPtLER3 HULTIPLEX CAB 125 CD RELIANCEV 044 99AX401437 SA 14 F

D i

J 4

j CS = COLD SHUT 00lti P

PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATI0tl HILESTottES REVISI0tt 5 -DECEt0ER 19C2 1

DA =DYNAHIC ANALYSIS

  • TEST ARTICLE BIAXIAL TESTING A mREEVALUATI0tl Col!PLETE F

FLOOR IIOUtiTED B sREQUEST FOR QUAL 02 BID ISSUED tiOIEs trJ.F.Er! Iri HS =tiOT STAT 0BY QP = QUALIFIED BY H mHEITHER CS OR HS C =S/H RECCittEt0ATI0ft TO LILCO

'T1PE IITtG' COLU!:t IS i

HBTetfULTI-FREQUEtiCY PIPIttG AFIALYSIS Z zPASSIVE ITEtt D sQUAL DOC RECEIVED QUAT 4TITY OF ITEttS.

i BIAXIAL TESTIttG SA zSTATIC AftALYSIS (SQRT PAPER HOT E zHARDilARE HODIFICATI0tt RFQ'O TitSTrt!ULTI-FREQUEt1CY SAT

  • sit 4GLE FREQUENCY REQ'DI F zQUAL DOC APVD & FILED SINGLE AXIAL TESTING SINGLE AXIAL TESTING G zSQRT PAPER C0!!PLETE l

l H zCOPIES OF DOC TO DISTRIDUTI0tl 4

1 9

l O

C O

$HOREHAM LSIIT 1 RBPH LIST STONE & HEZSTER Et:2INEE!ING CORPORATI0tt RUN DATE 12/20/82 JOB HLAtBER 11600 1-SORT REACTOR BUILDIt4G CATEGORY I PIPE HOUNTED EQUIPHENT RUN TIltE 13.24.25 i

i LILCO DOCHET 50-322 AL;TIVE BOP QUALIFICATION LEVEL (392 ITEHS)

PAGE 1 5

7 8

1 2

3 4

OPER LOAD-G'S OPERATOR 6

QUAL STATUS HARH PIPE QUAL SPEC LOC.

HURBER SIZE REPT NO.

HOR VER SUPPLIER HODEL HO.

YCHE CPER IB21mHOV031 3/1 SR-6060 88V PC 2.4 1.1 LIHITORQUE SIB-00-10 H

H IB21mHOV032 3/1 SR-6060 88V SC 3.2 1.3 LIHITORQUE Ste-000-5

  • H H

1821mHOV034 3

SR-6060 88V SC 1.2 1.4 LIMITORQUE

$l8-00-7.5 H

11 1821mHOV035A 20/1 20-1500GLO9 88AD SC 9.8 2.4 LIMITORQUE SPD-1-40 H

H IB214HOV035B 20/1 20-1500GLO9 88AD SC 7.5 3.5 LIIIITORQUE Ste-1-40 H

H 1821=HOV061 2/1 SR-6188 253 SC 1.8 1.0 LIHITORQUE SIB-00-13 F

F IB21mHOVO62 2/1 SR-6188 253 SC 1.4 1.7 LIHITORQUE SIB-00-10 F

F IB21mHOV063 2/1 SR-6188 253 SC 2.0 1.2 LIHITORQUE SIB-00-10 F

F IB21ml10VO64 2/1 SR-6188 253 SC 1.8 1.2 LIMITORQU2 512-00-10 F

F IB21mrt0V068A 2/1 SR-6188 253 SC 1.4

.9 LIMITORQUE S118-000-5 H

H I

1021mHOV0688 2/1 SR-6188 253 SC 1.4 1.8 LIMITORQUE SHB-000-5 H

li 1821mHOV068C 2/1 SR-6188 253 SC 1.8

.9 LIMITORQUE SIB-000-5 H

H I

1B21mHOV0680 2/1 SR-6188 253 SC 1.4 1.1 LIllITORQUE SIB-000-5 Il li 1821mHOV083 2/1 SR-6188 253 PC 2.0 1.2 LIMITORQUE S10-000-5 H

H ID21mit0V084 2/1 SR-6188 253 PC 1.6 1.2 LIHITORQUE Sta-000-5 H

II 1B21mHOV085 2/1 SR-4188 253 PC 1.8 1.5 LIHITORQUE S10-000-5 H

H 1821mSOV313A

.75 PE5265683271 600 SC 1.5 1.3 H

1B21mSOV3138

.75 IE5265683271 600 SC 1.5 1.3 H

1821mSOV314A

.75 HR5265683271 600 SC 1.5 1.3 H

~

QUALIFICATION HILEST0tlFS NOTES REVISION 5 -DEC[l:BER 1982 A = REEVALUATION CotPLETE

1. CL 2 AfD 3 VALVES < OR = 2 IH. ARE
5. PRESEtli QUALIFICATI0tl VALIO B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUtiTED (EHTG-5 I FOR OPERATOR LO?4S < OR = 3 G'S i

C =S/H REC 0tRIEt0ATION TO LILCO

2. m = DC HOTOR. ALL OTHERS ARE AC HORIZCtlTAL Ario VERTICAL (FAULTED)

D = QUAL DCC RECEIVED

3. CL 1 VALVES < OR = 1 IH. ARE
6. IF OfLY OttE LOAD IS GIVEN FC2 i

E=HARDHARE 1100IFICATION REQ'D FLOOR-HOUNTED IEHTG-53 THE DPERATCH. IT IS THE ItAXIltUll I

F = QUAL 00C APVD & FILED

4. 2/3 = 2 IN. CLASS 1 G =SQRT PAPER ColtPLETE H = COPIES OF DOC TO DISTRIBLITION 4

is

k SHOREHAM 12 TIT 1 RBPH LIST STONE & HEBSTE3 ENGINEERING CORPORATION RUN D*.TE 12/20/02 JOS HLABER 11600 1-SORT REACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIPHENT RUti TIllE 13.24.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEttS)

PAGE 2 5

7 8

1 2

3 4

OPER LOAD-G'S OPERATOR 6

QUAL STATUS HARN PIPE OUAL SPEC LOC.

tAABER SIZE REPT NO.

HOR VER SUPPLIER HODEL NO.

YCHE LPER 1821mSOV3148

.75 65tS265683271 400 SC 1.5 1.3 H

1831aA0V081

.75 10.3.115 318 PC 1.0 2.5 COPES D-100-40 H

H 1

1831pA0V082

.75 10.3.115 318 SC

.6

.6 COPES D-100-60 H

H IC41mR$!O21A 1.5 502644 191 SC 1.5 1.3 F

l IC41aRV0218 1.5 502644 191 SC 1.5 1.3 F

1011mHOV0324 1

SR-6190 253 PC 2.3 2.3 LIHITORQUE Ste-000-2 D

F 1

t 1011mHOV0328 1

SR-6190 253 SC

.6

.5 LIHITORQUE SHB-000-2 D

F

)

1011mHOV033A 1

SR-6190 253 PC 2.3 2.5 LIHITORQUE stb-000-2 0

F ID11eHOV0338 1

SR-6190 253 SC

.6

.5 LIMITORQUE SitD-000-2 D

F 1E11mA0V061A

.75 10.3.115 318 SC

.7

.6 COPES D-100-60 H

H IE11mA0V0618

.75 10.3.115 318 SC

.6

.7 COPES D-100-60 H

H IE11mAOV042A

.75 10.3.115 318 SC

.6

.5 COPES

  • D-100-60 H

H l

1E11mA0V0428

.75 10.3.115 318 SC

.6

.6 COPES D-100-40 H

H IE11hHOV031A 20 E5836-1.2 88AD SC 7.4 1.1 LIMITORQUE stb-0-40 H

H 1E11aHOV0318 20 E5836-1.2 88AD SC 4.0

.5 LIIIITORQUE stb-0-40 H

H J

IE11aHOV031C 20 EE836-1.2 88AD SC 5.3

.5 LIllITORQUE SIB-0-40 H

H I

IE11mHOV031D 20 E5836-1.2 88AD SC 5.8

.5 LIllITORQUE stb-0-40 H

H 1

1E11mHOV032A 20 E5836-1.2 88AD SC 4.1 1.6 LIHITORQUE 518-0-40 H

'H j

IE11eHOV0328 20 E5836-1.2 88AD SC 4.4 7.2 LIHITORQUE St B-0-40 H

H

~

QUALIFICATION HILESTottES HOTES REVISION 5 -DECEt:BER 1982 1

4 A zREEVALUATION C0tFLETE

1. CL 2 APB 3 VALVES < OR = 2 IN. ARE
5. PRESENT QUALIFICATION VALIO B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EHTG-5 I FOR OPERATOR LOADS < OR = 3 G'S l

C =S/H REC 0titIEtBATION TO LILCO

2. m : DC it0 TOR. ALL OTHERS ARE AC HORIZ0! ITAL AfD VERTICAllFAULTEDI

)

D zQUAL DOC RECEIVED

3. CL 1 VALVES < OR a 1 IN. ARE
6. IF Ott.Y Of(E LOA 3 IS GIVEll FC7 i

E:HAEDHARE HODIFICATION REQ'D FLOOR-fl0UNTED (EHTG-53 THE OPERATCR. IT IS THE ItA%Ilvt j

~

F

  • QUAL DOC APV3 & FILED
4. 2/1 a 2 IN. CLASS 1 G zSQRT PAPER COttPLETE H = COPIES OF 00C TO DISTRIBUTION 3

i

)

-m

~

s d

V

/

SHOEEHAH UNIT 1 RDPH LIST STONE & HEBSTE2 ENGINEE::ING CORPORATION EUH DATE 12/20/02 JOS IU BER 11600 1-SORT REACTOR BUILDING CATEGORY I PIPE HoutlTED EQUIPHENT RUN TIllE 13.24.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0H LEVEL (392 ITEllSI PAGE 3 l

t 5

7 8

1l 1

2 3

4 OPER LOAD-G'S OPERATOR 6

QUAL STATUS j

HARK PIPE QUAL SPEC LOC.

HUlBER SIZE REPT NO.

HOR VER SUPPLIER H00EL 80.

YCl;E OPER 1E11mHOV032C 20 E5836-1,2 88AD SC 4.1 5.8 LIHITORQUE stb-0-40 H

H IE11mHOV032D 20 E5834-le2 88AD SC 5.2 6.5 LIHITORQUE Ste-0-40 H

H I

IE11mHOV033A 16 SR-4266 88V SC 3.6 1.7 LIMITORQUE stb-1-60 H

H IE11mHOV033B 16 SR-6266 38V SC 4.2 2.4 LIHITORQUE Ste-1-60 H

lt IE11mHOV034A IS 18-300A SSAD SC 1.0 1.0 LIHITORQUE Sis-3-150 H

H IE11mHOV014B 18 18-300A 88AD SC 1.5 1.9 LIllITORQUE SHD-3-150 H

H 1E11mHOV035A 16 SR-6266 88V SC 2.3 1.8 LIllITORQUE Ste-1-60 H

H j

IE11mtmV3358 16 SR-6264 88V SC 3.0 4.0 LIHITORQUE Ste-1-60 14 H

1E11mlOV034A 24 E5836-19 88AD SC 3.2 2.9 LIMITORQUE Ste-4-200 H

H i

1E11mHOV0368 24 E5836-19 88AD SC 7.6 2.2 LIMITORQUE stb-4-200 H

H i

l 1E11mHOV037A 24/1 2422900GT07 88AD SC 3.7 5.6 LIHITORQUE SB-4-200 H

H j

IE11mimV0375 24/1 2422900GT07 88AD SC 4.7 5.0 LIMITORQUE 58-4-200 H

H IE11mtOV038A 10 E5834-20 88AD SC 5.8 1.3 LIMITORQUE

$110-2-40 H

H i

IE11mHOV0388 10 E5836-20 88AD SC 3.5 1.5 LIMITORQUE stb-2-60 H

ti 1E11mit0V039A 10 SR-6082 88V SC 10.8 1.2 LIHITORQUE Ste-0-25 F

D l

l 1E11mtOV039B 10 S N 082 88V SC 4.G 3.8 LIMITORQUE SIB-0-25 H

H 1E11mHOV040A 16 SR-4266 88V SC 9.3 7.3 LIHITORQUE

$10-1-60 H

H j

IE11ml10V0408 16 SR-4266 88V SC 9.0 3.7 LIMITORQUE Ste-1-60 H

H 1E11mlCV041A 6

SR-6177 88V SC 5.8 2.3 LIllITORQUE stb-00-15 H

H

~

QUALIFICATION HILEST0tlES NOTES REVISIDH 5 -0ECEllDER 1902 4

A = REEVALUATION COfFLETE

1. CL 1 Ate 3 VALVES < OR = 2 IH. ARE
5. PRESENT QUALIFICATION VALID i

8 zREQUEST FOR QUAL OR BIC ISSUED FLOOR-HOUNTED (EHTG-5 I FOR OPERATOR LOADS < OR = 3 G'S i

C S/H RECOlittEtOAIION TO LILCO

2. m = DC tcTOR. ALL OTHERS ARE AC 110!?IZO!4TAL Arid VERTICAL (FAULTED)

D sOUAL 00C RECEIVED

3. CL 1 VALVES < OR = 1 IN. ARE
6. IF Ott.Y OtlE LOAD IS GIVEN FCR E=HAR0 HARE tt001FICATION REQ'D FLOOR-HOUNTED (ElfTG-5)

THE CPERATOR, IT IS Tite ItA::II:U:t 7

F = QUAL 00C APVD & FILED

4. 2/1 = 2 IH. CLASS 1 G =SQRT PArIR CollPLETE j

H -COPIES OF DOC TO DISTRIBUTION i

j is 1

q.

N.

SHOREHAM IMIT 1 R8PH LIST STotlE 1 HESSTFR ENGINEERING CORPORATION RUN DATE 12/20/82 JOB IMBER 11600 1-SORT REACTOR SUILDING CA EGORY I PIPE HOUNTED EQUIPHENT RUN tit!E 13.24.25.

LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEttS)

PACE 4 5

7 8

2 3

4 OPER LOAD-G'S OPERATOR 6

QUAL STATUS

.tARH PIPE QUAL SPEC LOC.

IMBER SIZE REPT NO.

HOR VER SUPPLIER HODEL fB.

YCHE OPER 1E11mHOV0418 6

SR-6177 88V SC 4.6 2.3 LIHITORQUE stb-00-16 F

F 1E11mHOV042A 14 E5834-4 88AD SC 3.2 4.1 LIHITORQUE Ste-3-80 H

H IE11mHOV0428 16 E5836-4 88AO SC 3.3 4.8 LIHITORQUE 562-3-80 H

H IE11mHOV0434 4

SR-4180 88V SC 1.2

.6 LIlf1 TORQUE stb-00-15 H

H 1E11mit0V0438 4

SR-6180 88V SC 1.6 1.0 LIHITORQUE stb-03-15 H

H IE11mHOV0444 4

SR-6180 88V SC 1.4

.4 LIHITORQUE Ste-00-15 H

H IE11mHOV0448 4

SR-6180 88V SC 2.4 1.8 LIHITORQUE stb-00-15 H

IE11mHOV045A 4

SR-6180 88V SC 1.4 1.1 LIHITORQUE stb-000-5 H

H IE11mHOV045B 4

SR-4180 88V SC 2.8 2.2 LIMITORQUE Ste-000-5 H

H IE11mHOV047 20/1 20900-GT06 88AD PC 4.9 3.3 LIHITORQUE

$8-2 H H

IEI' dt0V048 20/1 20900-GT06 88AD SC 4.4 3.8 LIMITORQUE 58-2-40 m H

11 1E11mHOV049 10 SR-4260 88V SC 1.9 3.0 LIHITORQUE Ste-2-80 H

H 1E11mit0V050 20 88V SC 9.8 4.3 LIMITORQUE SitB-2-40 B

F 1E11mHOV051 4

SR-6180 88V SC 1.5 1.5 LIHITORQUE

$110-00-7 1/2 H

H IE11mHOV052 4

SR-4180 88V SC 2.8 1.3 LIMITORQUE SIB-00-10 H

H IE11mit0V053 4

SR-6068 88V SC 2.4 2.4 LIHITORQUE S12-00-10 m H

H IE11mit0V054 4/1 SR-6068 88V PC 3.1 2.9 LIHITORQUE SitB-00-15 H

It i

1E11mHOV055A 1

SR-4190 253 SC

.6

.5 LIHITCRQUE stb-000-2 H

H 1E11mHOV055B 1

SR-6190 253 SC

.6

.5 LIHITORQUE Sf*3-000-2 H

H QUALIFICATION HILESTONES NOTES REVISION 5 -DECEtOER 1982 A zREEVALUATION CotPLETE

1. CL 2 AFB 3 VALVES < OR = 2 IN. ARE
5. PRESENT QUALIFICATION VALID B : REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EHTG-5 )

FOR OPERATOR LOADS < OR = 3 G'S C zS/H REC 0fttENDATION TO LILCO

2. m a DC HOTOR. ALL OTHERS ARE AC HO"IIZ0tiTAL AFC VEI!TICALIFAULTED)

D =CUAL DOC RECEIVED

3. CL 1 VALVES < CR = 1 IN. ARE
6. IF Ota.Y OfiE LOAD IS GIVEtt FC2 E=HARDHARE tt00!FICATION REQ'O FLOOR-HOUNTED (EHTG-5)

THE OPERATOR. IT IS THE HA::It:U:t

~

F zQUAL DOC APVD E FILED

4. 2/1 a 2 IH. CLASS 1 G =SQRT PAPER CC:!PLETE H
  • COPIES OF DOC TO DISTRIBUTION I

I 7l

JR SHOREHAH LMIT 1 RBPH LIST STONE & HEBSTE2 ENGINEE%ING CORPORATION RUti DATE 12/20/82 JOB HUtBER 11600 1-SORT REACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIPHENT RUN TIltE 13.24.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATI0tf LEVEL (392 ITEHS)

PAGE 5 5

7 8

1 2

3 4

OPER LOAD-G'S OPERATOR 6

QUAL STATUS HARN PIPE QUAL SPEC LOC.

NUtBER SIZE REPT NO.

HOR VER SUPPLIER I!ODEL tiO.

YC:M OPER 1E11mHOV056A 1

SR-6190 253 SC

.6

.5 LIHITORQUE

$12-000-2 H

11 1E11mHOV0568 1

SR-6190 253 SC

.5

.5 LIHITORQUE Ste-000-2 H

11 1E11mHOV057A 1

SR-6190 253 SC

.9

.5 LIHITORQUE Ste-000-2 D

F IE11 mil 0V0578 1

SR-6190 253 SC

.6

.5 LIHITORQUE S!B-000-2 D

F a

1E11mPCV003A 10 10.3.115 318 SC 2.9 3.0 CCPES D-100-160 H

H IE11mPCV003B 10 10.3.115 318 SC

.9

.6 COPES D-100-160 H

H IE11mPCV007A 4

10.3.115 318 SC 1.2

.9 COPES D-100-100 11 H

IE11mPCV007B 4

10.3.115 318 SC

.6 1.3 COPES D-100-100 H

H IE11 MRV 151A 1

502644 191 SC 1.5 1.3 F

1E11 MRV 1518 1

502644 191 SC 1.5 1.3 F

1

}

1E11 MRV 151C 1

502644 191 SC 1.5 1.3 F

IE11 MRV 151D 1

502644 191 SC 1.5 1.3 F

j IE11 MRV 152A 4

502644 191 SC 1.3 1.0 F

IE11 MRV 1528 4

502644 191 SC 4.0 2.3 F

I IE11 MRV 153A 1

502644 191 SC 1.5 1.3 F

IE11 MRV 1538 1

502644 191 SC 1.5 1.3 F

IE11 MRV 154 1

502644 191 SC 1.5 1.3 F

1 IE11 MRV 155 2

502644 191 SC 1.5 1.3 F

1 1E11 MRV 162A 1

502644 191 SC 1.5 1.3 F

)

QUALIFICATION HILESTONES tt0TES REVISIDH 5 -DECElBER 1982

~

j e

A = REEVALUATION ColFLETE

1. CL 2 AtB 3 VALVES < OR = 2 IN. ARE
5. PRESET (T QUALIFICATI0tl VALIO B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EllTG-5 )

FOR OPERATOR LOADS < CR s 3 Gas j-C =S/H RECOtStEtOATI0tt TO LILCO

2. m a DC l'OTOR.

ALL OTHERS ARE AC HORIZO!!Tt.L AtO VERVICtLIFAULTED) i 0 zQUAL 00C RECEIVED

3. CL 1 VALVES < OR = 1 IN. ARE
6. IF OtLY OttE LOAD IS GIVEN FOR E llAR0 HARE HODIFICATION REQ'O FLOOR-HOUNTED (EHTG-5)

THE OPERATOR. IT IS THE ltAXIttUll i

F zCUAL 00C APVD & FILED

4. 2/1 a 2 IN. CLASS 1 1

G zSQRT PAPER C0tlPLETE 3

H : COPIES OF DOC TO DISTRIBUTION 1

l 1E

m SHOREHAH 121IT 1 EBPH LIST STot4E & HE;5TE3 ENGINEE3ING CORPORATION RUN DATE 12/20/02 JOB HUlBER 11400 1-SORT REACTOR BUILDING CATEGORY I PIPE HOUllTED EQUIPHENT RUN TIltE 13.24.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEttS)

PAGE 6 5

7 8

1 2

3 4

OPER LOAD-G'S OPERATOR 6

QUAL STATUS HARN PIPE QUAL SPEC LOC.

NUtBER S*ZE REPT HO.

HOR VER SUPPLIER HCOEL HO.

YGHE OPER 1E11 MRV 1625 1

502644 191 SC 1.5 1.3 F

F IE11 MRV 163

.75 502644 191 SC 1.5 1.3 1E11 MRV 164

.75 502644 191 SC 1.5 1.3 F

IE11mSOV166A

.75 M 5265683271 600 SC 1.5 1.3 H

1E11mSOV166B

.75 M 5265683271 400 SC 1.5 1.3 H

IE11mSOV167A

.75 M 5265683271 600 SC

, 1.5 1.3 H

IE11mSOV1678

.75 tmS265683271 600 SC 1.5 1.3 H

1E11mSOV168

.75 NtS265683271 400 SC 1.5 1.3 H

1E11mSOV169

.75 M 5265683271 600 SC 1.5 1.3 H

I IE21ml10V031A 14 E5836-7 88AD SC 3.4 2.5 LIMITORQUE Ste-000-5 H

H 1E21mHOV0318 14 E5836-7 88AD SC 3.5

.6 LIHITORQUE stb-000-5 H

H IE21mHOV033A 10/1 SR-6259 88V SC 7.9 2.1 LIMITORQUE SHB-2-80 H

11

)

IE21mHOV033B 10/1 SR-6259 88V SC 7.9 1.3 LIMITORQUE Ste-2-80 H

H IE21mHOV034A 3

SR-6183 88V SC 1.6

.8 LIHITORQUE S*B-000-5 H

H IE21mit0V034B 3

SR-6183 88V SC 1.2

.6 LIllITORQUE SilD-000-5 H

H l

IE21stl0V035A 10 10-300GL 88AD SC 1.3 2.7 LIttITORQUE S10-1-40 H

H i

i 1E21stt0V0358 10 10-30fnGL 88AD SC 1.3 2.7 LIH1 TORQUE SIB-1-40 H

H IE21 MRV 092A

.75 502644 191 SC 1.5 1.3 F

IE21 MRV 0925

.75 502644 191 SC 1.5 1.3 F

~

QUALIFICATI0ft HILESTONES NOTES REVISIOtt 5 -DECEl:SER 1982 i

I i

A = REEVALUATION C0tPLETE

1. CL 2 Are 3 VALVES < OR = 2 IN. ARE
5. PRESENT QUALIFICATION VALID B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (ElfTG-5 i FOR OPERATOR LOADS < CR = 3 C'S l

C =S/H REC 0fRfENDATI0tt TO LILCO

2. m = DC ISTOR. ALL OTHERS ARE AC HORIZOt4TAL At:D VERTICALIFAULTE03 i

D = QUAL DOC RECEIVED

3. CL 1 VALVES < OR = 1 IH. ARE
4. IF Ota Y O!!E LOAD IS GIVEN FOR l

E=HARCHARE HODIFICATION REQ'O FLOOR-HOUNTED IElfTG-51 THE OPERATOR IT IS THE IIAXII:Utt

~

F = QUAL DOC APVD & FILED

4. 2/1 a 2 IN. CLASS 1

{

G =SQRT PAPER CollPLETE H = COPIES OF DOC TO DISTNIBUTION j

i i

4s l

18 Dg O

0%

D SHOREHAH UNIT 1 RBPH LIST STONE & HEBSTER ENGINEERING CORPORATION RUN DATE 12/20/02 i

JOB tautBER 11600 1-50RT REACTOR BUILDING CATEGORY I PIPE HotRITED EQUIPHENT RUtt TIttE 13.24.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEttS)

PACE 7

(

5 7

8 1

2 3

4 OPER LOAD-G'S OPERATOR 6

QUAL STATUS HARH PIPE QUAL SPEC LOC.

lAABER SIZE REPT HO.

HOR VER SUPPLIER 1100EL HO.

YC:-lE CPER 1E21 MRV 093A 1.5 502644 191 SC 1.5 1.3 F

1E21 MRV 0938 1.5 502644 191 SC 1.5 1.3 F

1E21 MRV 096A

.75 502344 191 SC 1.5 1.3 F

IE21 MRV 0968

.75 502644 191 SC 1.5 1.3 F

1E32mHOV021A 1.5/1 SR-4706 253 SC 2.5 1.3 LIllITORQUE SitC-04-5 F

F 1E32mHOV021B 1.5/1 SR-6706 253 SC 2.8 1.9 LIMITORQUE SitC-04-5 F

F 1E32mHOV021C 1.5/1 SR-4704 253 SC 2.5 2.4 LIMITORQUE SitC-04-5 F

F IE32mHOV021D 1.5/1 SR-6706 253 SC 2.4 1.5 LIHITORQUE SIC-04-5 F

F IE32mHOV022A 1.5/2 SR-4706 253 SC 2.3 1.5 LIHITORQUE SitC-04-3 F

F 1E32mit0V022B 1.5/2 SR-6704 253 SC 2.0 1.7 LIllITORQUE SHC-04-3 F

F 1E32mHOV022C 1.5/2 SR-4704 253 SC 2.2 2.7 LIMITORQUE SHC-04-3 F

F 1E32mHOV0220 1.5/2 SR-6706 253 SC 2.4

.8 L!HITORQUE StC-04-3 F

F 1E32mit0V023A 1.5/2 SR-6706 253 SC 1.2

.7 LIH1 TORQUE SitC-04-3 F

F 1E32mit0V023B 1.5/2 SR-4706 253 SC 1.2

.7 LIllITORQUE SIC-04-3 F

F i

j 1E32mit0V023C 1.5/2 SR-6704 253 SC 1.1

.5 LIltITORQUE SitC-04-3 F

F 1E32mHOV023D 1.5/2 SR-6706 253 SC 1.7

.5 LIHITORQUE SIC-04-3 F

F 1E32mHOV024 2/2 SR-4188 253 SC 2.1 1.2 LIHITORQUE SFB-000-5 H

ll 1E32mit0V025 2/2 SR-4188 253 SC 1.1

.7 LIHITORQUE Ste-000-5 H

H 1E32aHOV026 2/2 SR-4188 253 SC 1.4

.9 LIttITORQUE Ste-000-5 H

11

~

QUALIFICATION HILEST0ftES NOTES REVIS10tl 5 -0ECEl2ER 1982 A =REEVALUATI0tl COIPLETE

1. CL 2 AfD 3 VALVES < OR = 2 IN. ARE
5. PPESEt(T QUALIFICATIOri VALID B = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EllTG-5 I FOR OPERATOR LOADS < 02 = 3 G'S C =S/H REC 0!DIEFIDATION TO LILCO
2. e = DC HOTOR. ALL OTHERS ARE AC 110RIZCNTAL AfD VERTICALIFAULTEDI D = QUAL DOC RECEIVED
3. CL 1 VALVES < OR = 1 IH. ARE
6. IF OtLY CNE LOAD IS GIVEll FCQ

[

E=HARDilARE HODIFICATION REQ'D FLOOR-HOUNTED (EHTG-51 Tite OPERATOR. IT IS THE ItAXIt'Utt

]

I F = QUAL DOC APVD & FILED

4. 2/1 a 2 IN. CLASS 1 G =SQRT PAPER CottPLETE H = COPIES OF DOC TO DISTRIBUTION h

1 l

a

'E A

f^

U

'A

\\

l SHOREHAM UNIT 1 RBPH LIST STONE & HEBSTE3 ENGINEEXING CORPORATION RUN DATE 12/20/12 i

JOB IRABER 11600 1-$0RT REACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIPHEHT Rt.N TIttE 13.24.25

(

LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEHS)

PAGE 8 5

7 8

1 2

3 4

OPER LOAD-G'S OPERATOR 4

GUAL STATUS HARN PIPE QUAL SPEC LOC.

PAABER SIZE REPT HO.

HOR VER SUPPLIER HODEL NO.

YCl:E CPER 1E32mHOV027 2/2 SR-4188 253 SC 1.6

.5 LIHITORQUE Ste-000-5 H

H j

1E41mA0V081 1

10.3.115 318 SC

.4

.4 COPES D-100-60 H

H IE41mA0V082 1

10.3.115 318 SC

.5

.5 COPES D-100-40 H

H I

1E11mA0V083 1

10.3.115 318 SC

.4

.5 COPES D-100-40 H

H 1E41mLCV-091 1

10.3.115 318 SC

.6

.4 COPES D-100-40 H

H IE41mLCV095 1

10.3.115 318 SC

.7

.6 COPES D-100-40 H

H 1E41mit0V031 14 SR-6266 88V SC 10.4 2.4 LIHITORQUE stb-0-25

  • F B

IE41mHOV032 14 SR-4246 88V SC 4.5 1.3 LIHITORQUE stb-0-25 e H

H IE41mHOV034 14 SR-6247 88V SC 7.7 2.4 LIHITORQU2 515-2-40 m H

H

,i 1E41mHOV035 14/1 19900-GT05 86AD SC 7.3 3. ~,

LIHITORQUE Ste-3-100 m H

H IE41mHOV036 4

SR-4068 88V SC 3.1 1.3 LIMITORQUE stb-00-10 m H

H 1E41mHOV037 8

SR-6349 88V SC 2.7

.9 LIllITORQUE stb-1-25 m H

H IE41mHOV038 10 SR-6262 88V SC 2.8 1.5 LIHITORQUE 582-1-40 m H

H IE41mit0V039 2/2 SR-6188 253 SC 1.3

.5 LIHITORquE

$42-00-5

  • H H

1E41mit0V041 10/1 SR-6259 88V PC 4.8 2.0 LIHITORQUE Ste-3-80 H

H l

IE41mHOV042 10/1 SR-6264 88V SC 2.4

.8 LIHITORQUE Ste-1-60

  • H H

IE41mHOV043 10 SR-6262 88V SC

.7

.5 LIHITORQUE SIB-1-40 m H

H i

j 1E41mH0V044 18 SR-6270 88V SC 2.3 2.4 LIllITORQUE Ste-0-15 m H

H l

IE41stt0V047 1/1 SR-6190 253 PC 4.0

.5 LIHITORQUE 582-000-2 H

H l

QUALIFICATICH HILESTO!iES TOTES REVISION 5 -0ECEtBER 1982 i

A = REEVALUATION C0tFLETE

1. CL 2 Ate 3 VALVES < OR = 2 IN. ARE
5. PRESENT QUALIFICATI0H VALIO 8 = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EllTG-5 i FOR OPERATOR LOADS < OR = 3 G'S C =S/H REC 0!0tENDATION TO LILCO
2. m a DC if0 TOR. ALL OTHERS ARE AC H02IZ0tiTAL AfD VERTICAL (Ft11.TE0 3 D = QUAL DOC RECEIVED
3. CL 1 VALVES < OR = 1 IN. ARE
4. IF OtLY OtlE LDAD IS CIVEH TC2 E=HARDHARE HODIFICATION REQ'D FLOOR-HOUNTED (EHTG-53 THE OPERATOR. IT IS THE ltAXIlfJtt I

F = QUAL DOC APVO & FILED

4. 2/1 = 2 IH. CLASS 1 6 =SQRT PAPER CottPLETE H = COPIES OF DOC TO DISTRIBUTION 2

l 1

__m Jh O

O SHOREHAM LMIT 1 RBPH LIST STONE & HEP, STER ENG1HEERING CORPORATION RUN DATE 12/20/82 JOB HUtBER 11400 1-50RT REACTOR BUILDING CATEGORY I PIPE HOLMTED EQUIPHENT RUN TIttE 13.24.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEHS)

PACE 9 5

7 3

1 2

3 4

OPER LOAD-G'S OPERATOR 6

QUAL STATUS HARN PIPE QUAL SPEC LOC.

tRABER SIZE REPT HO.

HOR VER SUPPLIER H00EL NO.

YCKE OPER 1E41mHOV048 1/1 SR-4190 253 SC

.9 2.0 LIMITORQUE Ste-000-2m H

H 1E41mHOV049 2/2 SR-6188 253 SC 4.7

.1 LIlliTORQUE stb-000-2m H

H IE41mPCV142 2/2 2-24451 310 SC 1.0

.5 BECH 14-101-ES H

H I

1E41 MRV 145

.75 502644 191 SC 1.5 1.3 F

1E41 MRV 144 1.5 502644 191 SC 1.5 1.3 F

1E41 MRV 147 1.25 502644 191 SC 1.5 3.3 F

IE41 MRV 149

.75 502644 191 SC 1.5 1.3 F

1E51mA0V081 1

10.3.115 318 SC

.6

.4 COPES D-100-40 H

H 1E51mA0V082 1

10.3.115 318 SC

.4

.6 COPES D-100-60 H

H j

1E51mA0V083 1

10.3.115 318 SC

.6

.4 COPES D-100-60 H

H I

i IE51mLCV091 1

10.3.115 318 SC

.6

.5 COPES D-100-60 H

H 1E51mLCV095 1

10.3.115 318 SC

.4

.5 COPES D-100-60 H

H 1

IE51stDV031 4

SR-6177 88V SC 7.4 3.9 LIHITORQUE SilD-00-5 m H

H I

j 1E51mHOV032 4

SR-6177 88V SC 4.4 2.1 LIHITORQUE SIB-00-5

  • H H

IE51mHOV034 4

SR-6068 88V SC 1.4 3.3 LIHITORQUE stb-00-10 m H

H j

1E51mitcV035 6/1 SR-6574 88V SC 4.4 5.2 LIIIITORQUE stb-00-25 m F

F 1E51mHOV036 2/2 SR-6108 253 SC 1.5

.7 LIHITORQUE stb-000-5

  • H H

IE51mHOV037 4

SR-4068 88V SC 2.2

.9 LIMITORQUE SIB-00-10

  • H H

l 1E51mit0V038 2/2 SR-6188 253 SC 1.2

.5 LIMITORQUE SiO-000-5

  • H H

~

QUALIFICATION HILEST0t{ES NOTES REVISI0tt 5 -0ECEllBER 1902 i

A =REEVALUATIDH CottPLETE

1. CL 2 AFB 3 VALVES < OR = 2 IM. ARE
5. PRESENT QUALIFICATION VALID B = REQUEST FOR QUAL OR IIID ISSUED FLOOR-HOUNTED (EHTG-5 )

FOR OPERATOR LOADS < CR = 3 G'S C =S/H REC 0tetEtIDATIO1 TO LILCO

2. m a DC lt0 TOR. ALL OTHERS ARE AC HORIZ0tiTAL AND VERTICALtFAL1.TEO)

D = QUAL 00C RECEIVED

3. CL 1 VALVES < OR = 1 IN. ARE
6. IF OtLY OftE LOAD IS GIVEN FOR E=HAPDHARE It001FICATIDH REQ'D FLOOR-HOUNTED (EHTG-5)

THE OPERATOR. IT IS THE ltAXIf full i

F = QUAL 00C APVD & FILED

4. 2/1 a 2 IM. CLASS 1

~

i G =SQRT PAPER C0tFLETE l

H = COPIES OF DOC TO DISTRIBUTION I

i l

l

' ss

y Je O

O, t

SHOREHAH UNIT 1 RBPH LIST STONE & HEBSTER ENGINEE!ING CORPORATION RUN DATE 12/20/02 JOB Hl2BER 11600 1-SORT REACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIPHENT RUN TIttE 13.24.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEllS)

PACC 10 5

7 8

1 2

3 4

OPER LOAD-G'S OPERATOR 4

QUAL STATUS HARN PIPE QUAL SPEC LOC.

tAJIBER SIZE REPT NO.

HOR VER SUPPLIER HODEL HO.

YC!E CPER IE51mHOV041 3/1 SR-4040 88V PC 2.5 2.1 LIHITORQUE stb-00-10 H

H 1E51mHOV042 3/1 SR-6060 88V SC 4.8 1.2 LIllITORQU5 SHB-00-7 1/2 H

H IE51mit0V043 3

SR-6060 88V SC 1.2

.4 LIHITORQUE stb-00-7 1/2 m

H H

1E51mHOV045 8

SR-6078 88V SC 4.4 3.4 LIttITORQUE stb-000-5 m H

H IE51stIOV046 2/2 SR-6188 253 SC 1.2

.5 LIHITORQUE Ste-000-2 m H

H l

1E51mHOV047 1/1 SR-6190 253 PC 5.3 1.4 LIMITORQUE Ste-000-2 H

H 1

1E51mHOV048 1/1 SR-4190 253 SC 8.7 2.8 LIMITORQUE Ste-000-2

  • D F

4 1E51stt0V049 1.5/2 SR-4189 253 SC 2.4

.8 LIlf1 TORQUE SIB-000-2

  • H H

2 i

1E51mPCV142 2/2 2-24451 310 SC 1.0

.5 BECH 14-101-DBQ H

H IE51 MRV 145

.75 502644 191 SC

.6

.2 H

I 1E51 MRV 146

.75 502644 191 SC

.6

.2 H

i l

1E51 MRV 147 1.F5 502644 191 SC

.6

.2 H

IE51 MRV 149

.75 502644 191 SC

.6

.2 H

4 IG11stmV246 4

SR-6180 88V SC 4.3 2.7 LIHITORQUE Ste-000-5 H

H j

1G11mtOV247 4

SR-6180 88V SC 3.6 5.9 LIMITORQUE Ste-000-5 H

ll IG11mtOV248 3

SR-6183 88V SC 1.7 1.3 LIHITORQUE stb-000-5 H

H 1G11mHOV249 3

SR-6183 88V SC 2.5 1.2 LIMITORQUE Ste-000-5 H

H

)

IG11st0V639 3

SR-6477 88V SC

.6

.5 LIHITORQUE SIB-000-5 H

H 1G33mlOV030A 4/1 SR-4068 88V PC 3.6 1.9 LIMITCRQUE stb-00-15 H

H QUALIFICATION HILESTONES NOTES REVISION 5 -DECElBER 1982 1

i A tREEVALUATION C0tFLETE

1. CL 2 Ate 3 VALVES < OR = 2 IN. ARE
5. PRESENT QUALIFICATION VALIO l

8 sREQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EHTG-5 I FOR OPERATOR LOADS < OR 3 G'S C :S/H REC 0titIEtOATION TO LILCO

2.
  • a DC HOTOR. ALL OTHERS ARE AC HORIZC'4TAL AFB VERTICAL (FAULTED)

)

D = QUAL DOC RECEIVED

3. CL 1 VALVES < OR = 1 IH. ARE
6. IF OttY CNE LOAD IS GIVEtt FC' i

E=HARDHARE It00IFICATION REQ'O FLOOR-HOUNTED (EHTG-SI THE OPERATOR. IT IS THE ttAXIliUll F = QUAL DOC APVD & FILED

4. 2/1 = 2 IH, CLASS 1 4

l G zSQRT PAPER C0lFLETE l

)

H = COPIES OF DOC TO DISTRIBUTION l

i 1

j

' is 4

4

30 SHJREHAH WIT 1 R8PH LIST STONE & HEISTEll ENGINECING CORPORATION RUN DATE 12/20/82 JOB NLAEER 11400 1-SORT REACTOR BUILDING CATEGORY I PIPE HOWTED EQUIPHENT RLil TIllE 13.2L25 LILCO DOCHET 50-322 ACTIVE BOP, QUALIFICATION LEVEL (392 ITEHS)

PAGE 11 5

7 8

1 2

3 4

OPER LOAD-G'S OPERATOR 4

QUAL STATUS HARH PIPE QUAL SPEC LOC.

tAABER SIZE REPT HO.

HOR VER SUPPLIER HDDEL No.

YOHE CPER I

IG33mHOV0308 4/1 SR-6068 88V PC 7.4 3.3 LIMITORQUE stb-00-15 H

H 1G33mHOV031 6/1 SR-6181 88V PC 5.5 2.5 LIMITORQUE

$62-0-40 H

H

'1G33mHOV032 4/1 SR-6068 88V PC 4.5 1.4 LIMITORQUE Ste-00-18 H

H 1G33mH0V033 4/1 SR-4181 88V PC 8.0

.4 LIttITORQUE Ste-00-25 H

H i

1633mHOV034 6/1 SR-6181 88V SC 4.6 2.4 LIMITORQUE stb-00-15

  • H H

1G33mHOV035 4

SR-6353 88V SC 1.8

.8 LINITORQUE Ste-0-15 H

H a

1G33mHOV036 4

SR-6353 88V SC

.9

.5 LIHITORQUE Ste-0-15 H

H 1633mH0v037 4

SR-6353 88V SC

.7

.8 LIHITORQUE Ste-0-15 H

H l

1G33mHOV038 4

SR-6068 88V SC

.7

.7 LIllITORQUE 582-00-15 H

H IG33mHOV039 4

SR-6068 88V SC

.4

.6 LIMITORQUE

$1B-00-15 H

H 1G33mH0V040 4

SR-6353 88V SC 1.4 1.1 LIHTTORQUE Ste-0-15 H

H 1G33mHOV041 6/1 SR-6574 88V SC 5.1 3.9 LIllITORQUE S12-1-25 H

H i

1 1G33etV093

.75 502644 191 SC 1.5 1.3 F

1G33 MRV 095A

.75 502644 191 SC 1.5 1.3 F

1G33 MRV 0955

.75 502644 191 SC 1.5 1.3 F

j 1641mHOV032A 6

1891-1 203 SC 1.3 1.5 LIHITORQUE stb-00-10 H

H i

j 1G41ml10V0328 4

1891-1 203 SC 1.1 1.0 LIHITORQUE SIB-00-10 H

ll IG41mit0V033A 6

SR-6177 88V SC 1.5 1.5 LIllITORQUE stb-000-5 H

H l

1641mHOV0338 6

SR-6177 88V SC 1.0 1.0 LIHITORQUE stb-000-5 H

11 f

l QUALIFICATION HILEST0t4ES iBTES REVISION 5 -0ECElBER 1982 l

]

A =REEVALUATIDH COIPLETE

1. CL F M e 3 VALVES < OR = 2 Itl. ARE
5. PRESENT QUALIFICATI0tl VALID l

8 = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED IEHTG-5 )

FOR OPERATOR LOADS < CR = 3 G'S l

C =S/H REC 0f01EtDATION TO LILCO

2. * = DC lt0 TOR. ALL OTHERS ARE AC HORIZotiTAL Arc VERTICALIFAULTED)

D = QUAL 00C RECEIVED

3. CL 1 VALVES < OR = 1 IN. ARE
6. IF Ort.Y OtlE LOAD IS GIVEtt FCR j

E=HAROHARE HODIFICATION REQ'O FLOOR-HOUNTED (EHTG-5)

THE OPERATOR. IT IS THE ltAXII:Utl I

F = QUAL DOC APVD & FILED

4. 2/1 = 2 IN. CLASS 1 i

G =SQRT PAPER COtFLETE H = COPIES OF DOC TO DISTRIBUTION 4

J O

O SHOREHAM UtlIT 1 RSPH LIST STONE & HEBSTE2 ENGINEE3ING CORPORATION RUN DATE 12/20/02 JOB NLRBER 11400 1-50RT REACTOR BUILDIllG CATEGORY I PIPE HOLRITED EQU1PHENT RUtt TIttE 13.24.25 i

LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEltS)

PAGE 12 5

7 8

1 2

3 4

OPER LOAD-G'S OPERATOR 6

QUAL STATUS HARN PIPE QUAL SPEC LOC.

tRABER SIZE REPi NO.

HOR VER SLFPLIER HODEL NO.

YCHE CPER 1G41mHOV0344 10 SR-4082 88V SC 4.9 1.1 LIHITORQUE Ste-0-7 1/2 H

H 1G41mHOV0348 10 SR-4082 88V SC 1.8

.5 LIHITORQUE Ste 0-7 1/2 H

H IG41 MRV 019A 1

502644 191 SC 1.5 1.3 F

1641 MRV 0198 1

502444 191 SC 1.5 1.3 F

1641 MRV 024 1

502444 191 SC 1.5 1.3 F

IG41 MRV 025 1

4 544 191 SC 1.5 1.3 F

IP41mHOV033A 20 b-v034-8 197 SC

.8

.8 LIHITORQUE H2BC/S'B0010 H

H IP41mit0V0338 20 0-0034-8

'197 SC

.7

.5 LIMITORQUE H2BC/SIE0010 H

H IP41mHOV033C 20 0-0034-5 197 SC 1.0

.5 LIHITORQUE H2BC/ stb 0005 H

H 1P41mHOV033D 20 0-0034-5 197 SC

.7

.8 LIHITORQUE H2BC/Ste0005 H

H IP41mHOV034A 20 D-0034-8 197 SC

.1

.1 LIMITORQUE H2BC/St2010 98 li 1P41mHOV0348 20 D-0034-8 197 SC

.4

.5 LIHITORQUE H2BC/St2010 H

11 IP41mHOV037A le D-0034-2 197 SC

.7

.5 LIHITORQUE H2BC/SitB005 H

H 1P41mHOV037B 14 D-0034-2 197 SC

.6

.8 LIHITORQUE H2BC/Sl2005 H

H 1P41mHOV039A 1/3 1891-1 203 SC

.7

.5 LIttITORQUE stb-000-2 H

H IP41mHOV0398 1/3 1891-1 203 SC

.5

.5 LIllITORQUE SIB-000-2 H

11 IP41mHOV042A 6

D-0034-9 197 SC 1.2 2.1 LIllITORQUE H0BC/Sl!D002 H

H I

l IP41mHOV0428 4

D-0034-9 197 SC 1.0 1.8 LIHITORQUE H0BC/St2002 H

H j

IP41mHOV043 1/3 1891-1 203 SC

.5

.5 LIHITORQUE stb-000-2 H

H

~

GUALIFICATION HILEST0llES NOTES REVISION 5 -0ECEtBER 1902 A = REEVALUATION ColFLETE

1. CL 2 Ate 3 VALVES < OR = 2 IN. ARE
5. PRESENT QUALIFICATION VtJ.IO 8 = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOLRITED IEHTG-5 I FOR OPERATCR LOADS < CR = 3 G'S j

C =S/H REC 0fttEtmATION TO LILCO

2. m = DC lt0 TOR. ALL OTHERS ARE AC HORIZOt4TAL Ato VERTICALIFAL1.1rD)

D = QUAL DOC RECEIVED

3. CL 1 VALVES < OR = 1 IN. ARE
4. IF Ote Y Ot:E LOAD IS GIVEN FC*t E=HARCHARE It00!FICATI0ft REQ'O FLOOR-HOUNTED (EHTG-Si THE OPERATOR. IT IS THE It/J:II".Jit T

F = QUAL DOC APVD & FILED

4. 2/1 = 2 IN. CLASS 1 6 =SQRT PAPER COtFLETE H = COPIES OF DOC TO DISTRIBUTION

't 9

jE p

s k

\\vl v

SHOREHAH tkfIT 1 RBPH LIST STONE & HE; STER ENGINEERING CORPORATION RUN DATE 12/20/62 JOB NUtBER 11400 1-SORT REACTOR BUILDING CATEGORY I PIPE !!OUNTED EQUIPitENT RUN TIttE 13.M.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEttS)

FACE 13 5

7 8

1 2

3 4

OPER LOAD-G'S OPERATOR 4

QU/L SitTUS

.i HARH PIPE QUAL SPEC LOC.

tAABER SIZE REPT 880.

HOR VER SUPPLIER HODEL NO.

YOME

0. ER__

IP41mHOV102A 1/3 1891-1 203 SC

.6

.5 LIHITORQUE stb-000-2 H

H IP41stl0V1028 1/3 1891-1 203 SC

.8

.5 LIMIT (HQUE stb-000-2 H

lt IP41mHOV129A 10 15438 281 SC 1.1 1.4 LIMITORQUE HIBC/ stb 0002 H

H IP41mHOV1298 10 15438 281 SC 1.9 1.8 LIttITORQUE Hit C/SMB0002 H

H IP41 MRV 024A 1

502644 191 SC 1.5 1.3 F

IP41 MRV 0248 1

502644 191 SC 1.5 1.3 F

1P41 MRV 110A

.75 502644 191 SC 1.5 1.3 F

IP41 MRV 1108

.75 502644 191 SC 1.5 1.3 F

IP41 MRV 119

.75 502644 191 SC 1.5 1.3 F

IP41 MRV 130A

.75 502644 191 SC 1.5 1.3 F

IP41 MRV 1308

.75 502644 191 SC 1.5 1.3 F

IP42mHOV031A 8

SR-6184 88V SC 1.7

.3 LIHITORQUE stb-000-5 H

H 1P47 HOV0318 8

SR-6186 88V SC 1.8

.5 LIMITORQUE Ste-000-5 H

H IP42et10V032A 8

SR-6184 88V SC

.6

.5 LIMITORQUE S12-000-5 H

II IP42 mil 0V0328 8

SR-4186 88V SC

.6

.6 LIltITORQUE stb-000-5 H

H IP42mHOV033A 4

SR-4199 88V SC

.6 1.0 LIMITORQUE SIB-000-5 H

H IP42 mil 0V0338 6

SR-6199 88V SC

.7 1.0 LIHITORQUE Ste-000-5 H

H

]

IP42ml10V034A 6

SR-6199 88V SC 1.3 1.1 LIlfITORQUE stb-000-5 H

H IP42mHOV034B 6

SR-6199 88V SC 1.2 1.1 LIllITORQUE Sis-000-5 H

H

~

QUALIFICATION HILESTONES NOTES REVISION 5 -DECEllCER 1982 1

A =REEVALUATI0tt Cots'LETE

1. CL 2 AtB 3 VALVES < OR = 2 IH. ARE
5. PRESET 4T QUALIFICATION VALIO B = REQUEST FOP CUAL OR BID ISSUED FLOOR-IIOUNTED tEllTG-5 )

FOR OPERATCR LOADS < OR = 3 G'S C =S/H RECOtDIEtDATI0tt TO LILCO

2. m = DC HOTOR. ALL OTHERS ARE AC HORIZOt4TAL AtB VERTICALIFAULTEDI D = QUAL DOC RECEIVED
3. CL 1 VALVES < OR = 1 IN. ARE
4. IF O!LY CHE LOA 3 IS GIVEtt iCR E=HARDHARE HODIFICATION REQ'D FLOOR-HOUtiTED (EHTG-5)

THE OPERATOR, IT IS Tile IIAXII!Utt I

F = QUAL DOC APVD & FILED

4. 2/1 = 2 IH. CLASS 1 G =SQRT PAPER C0!!PLETE

]

H = COPIES OF DOC TO DISTRIBUTION 1

I 1B

]

s.

l sm v

SHOREHAM LMIT 1 RBPH LIST STCHE & HEBSTER ENGIHEECINE CORPORATION RtAl EATE 32/20/02 JOB IM BER 11400 1-SORT REACTOR BUILDING CATEGORY I PIPE HOUllTED EQUIPHENT RUN TIltE 13.24.25 LILCO 00CHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEHS)

PALE 14 5

7 8

1 2

3 4

OPER LOAD-G'S OPERATOR 4

QUAL STATUS HARN PIPE QUAL SPEC LOC.

IMEER SIZE REPT NO.

HOR VER SUPPLIER lt00EL NO.

YO!;E C?[R 1P42mHOV035 4

SR-4180 88V SC 4.4 3.8 LIMITORQUE SM5-000-5 H

H 1P42mit0V034 4

SR-6180 88V SC 4.4 2.3 LIHITORQUE SIB-000-5 H

H.

4 1P42mHOV041A 14 SR-4265 88V SC 2.2 1.9 LIMITORQUE 508-0-25 H

H IPS2ml10V0418 14 SR-6265 88V SC 2.1 2.0 LIMITORQUE Ste-0-25 H

H IP42mit0V042A 14 SR-4265 88V SC 1.4 2.1 LIHITORQUE stb-0-25 H

H IP42mHOV0428 14 SR-6265 88V SC 1.4 2.2 LIllITORQUE 588-0-25 H

H IP42mHOV043A 8

SR-6184 88V SC 1.1

.4 LIHITORQUE Ste-000-5 H

H 1P42mHOV043b 8

SR-4184 88V SC 3.0

.6 LIIIITORQUE Ste-000-5 H

H IP42mHOV044A 8

SR-4184 88V SC 1.0

.6 LIltITORQUE Ste-000-5 H

H IP42mHOV0448 8

SR-6166 88V SC 2.9 1.4 LIMITORQUE SIB-000-5 H

H i

i IP42mHOV047 4

SR-6180 88V SC 3.7 4.2 LIHITORQUE Sie-000-5 H

H IP42mHOV048 4

SR-4180 88V SC 4.0 3.1 LIHIVORQUE SIB-000-5 H

H IP42mHOV147 4

SR-4100 88V PC 4.3

.9 LIHITORQUE SIB-000-5 H

H

]

IP42mileV148 4

SR-4180 88V PC 4.2 1.0 LIMITORQUE Sles-000-5 11 H

IP42 mil 0V231 4

SR-6180 88V SC 1.0

.8 LIMITORQUE SIB-000-5 H

H l

IP42mHOV232 3

SR-6183 88V SC 3.5 7.1 LIltITORQUE Ste-000-5 H

H IP42mHOV233 3

SR-6183 88V 3C 4.4 9.8 LIMITORQUE Ste-000-5 H

H IP42mHOV234 3

SR-4183 88V SC 5.4 9.5 LIMITORQUE SIB-000-5

'4 H

j IP42mHOV235 3

SR-4183 88V SC 5.9 7.9 LIHITORQUE SIB-000-5 H

H QUALIFICATION HILESTONES HDTES REVISIOli 5 -DEC[ LEER 1982

~

f A = REEVALUATION ColFLETE

1. CL 2 AFB 3 VALVES < OR = 2 IH. ARE
5. PRESENT QUALIFICATI0H VALIO 8 = REQUEST FOR QUAL OR SID ISSUED FLOOR-H0utlTED (EHTG-5 i FOR OPERATOR LOADS < CR = 3 G'S C =S/H REColtfENOATIDH TO LILCO
2.
  • a DC ltGTOR. ALL OTHERS ARE AC HCRIIOllTAL AfD VERTICtLIFAt'LTE3 9 D = QUAL DOC RECElVED
3. CL 1 VALVES < OR e 1 IH. ARE
4. IF Ote.Y ONE LOAD IS GIVEll FCR E=HARDHARE It00IFICATION REQ'D FLOOR-It0UllTED (EHTG-5)

THE OPERATOR. IT IS TiiE ItAXIf:Ull Y

F = QUAL 00C APVD & FILED

4. 2/1 a 2 IH. CLASS 1 4

G =SQRT PAPER Col:PLETE H COPIES OF DOC TO DISTRIBUTICH i

15 SHOREHAM LMIT 1 RSPH LIST STONE & HESSTE2 ENGINEE2ING CORPORATICH RtRE DATE 12/20/02 JOR IU BER 11400 1-50RT REACTOR SUILD1HG CATEGORY I PIPE HOUNTED EQUIPHENT RUN TIllE 13.24.25 LILCO DOCHET 50-322 ACTIVE 80P QUALIFICATION LEVEL (392 ITEHS)

PAGE 15 5

7 8

i 1

2 3

4 OPER LOAO-G's OPERATOR 4

OUAL STATU3 HARH PIPE QUAL SPEC LOC.

ISABER SIZE REPT NO.

H04 VER SUPPLIER HODEL ts.

YCt;E OPER 1P42mHOV236 4

SR-6180 88V SC 6.4 3.4 LIMITORQUE 585-000-5 H

H IP42 mil 0V237 3

SR-4183 88V SC 4.0 2.5 LIMITORQUE Sts-000-5 H

H IP42mHOV238 3

SR-4183 88V SC 4.5 1.4 LIMITORQUE stb-000-5 H

H IP42mHOV239 3

SR-4183 88V SC 7.4 2.2 LIMITORQUE SIB-000-5 H

H IP42mHOV240 3

SR-4183 88V SC 3.8 1.7 LIMITORQUE Sts-000-5 H

H IP42mPCV071 4

10.3.115 318 SC 1.2

.5 COPES D-100-44 H

H IP42 MRV 079A 1

502444 191 SC 1.5 1.3 F

1P42ml4V0798 1

502644 191 SC 1.5 1.3 F

k IP42 MRV 080A 1

502444 191 SC 1.5 1.3 F

IP42 MRV 0808 1

502644 191 SC 1.5 1.3 F

IP42 MRV 080C 1

502694 191 SC 1.5 1.3 F

IP42 MRV 0800 1

502644 191 SC 1.5 1.3 F

IP42 MRV 091A 1

502644 191 PC 6.9 3.0 F

IP42 MRV 0918 1

502644 191 PC 4.9 3.0 F

IP42 MRV 291A

.75 502444 191 PC 4.9 3.0 F

IP42 MRV 2918

.75 502644 191 PC 6.9 3.0 F

l 1P42mTCV001H 12 CD76-82 423 SC 1.1 1.1 FISHER 454-44 H

H IP42mTCV001X 10 CD74-82 423 SC

.9 2.3 FISHER 454-40 H

H 1P42mTCV001Y 12 CD74-82 423 SC 1.9 1.4 FISHER 454-60 H

H

~

QUALIFICATION HILESTONES NOTES REVISION 5 -DECElBER 1982 A = REEVALUATION CotPLETE

1. CL 2 AFB 3 VALVES < OR = 2 IH. ARE
5. PRESENT QUALIFICATION VALID 8 = REQUEST FOR QUAL OR SID ISSUED FLOOR HOUNTED EENTS-5 i FOR OPERATOR LOADS < OR = 3 G'S C zS/H RECottlEteATION TO LILCO
2. a a DC HOTOR. ALL OTHERS ARE AC HORIZ0tiTAL AtB VERTICALIFAt'LTED)

D zQUAL DOC RECEIVED

3. CL 1 VALVES < OR s 1 IN. ARE
4. IF Ott.Y OtlE LOAD IS GIVElf FC2 E=HARollARE HODIFICATION REQ'O FLOOR-HOUl4TED (EHTG-5)

THE OPERATOR IT IS THE IIAXIltUt

~

F zQUAL DOC APVD 1 FILED

4. 2/1 = 2 IN. CLASS 1 G =SQRT PAPER C011PLETE H = COPIES OF DOC TO DISTRIBUTION El

2h 4

'J SHOREHAH LRtIT 1 RBPM LIST STONE & HEISTER ENGIHE C ING CORPORATICH RUN CATE 12/20/82 JOS MJitBER 11400 1-SORT REACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIPitENT RUN TIllE 13.24.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEMS)

PAGE 14 5

7 8

1 2

3 4

CPER LOAD-G'S OPERATOR 4

QUAL STATUS HARN PIPE QUAL SPEC LOC.

NLASER SIZE REPT NO.

HOR VER SUPPLIER HDDEL tc.

YC:(E CPER 1P42mTCV001Z 10 CD74-82 423 SC 2.0 1.8 FISHER 454-40 H

H 1P50mHOV103A 1.5/2 SR-4169 214 SC

.5

.7 LIHITORQUE stb-000-5 H

H j

1P50mHOV1038 1.5/2 SR-4169

.444 SC

.5

.5 LIltITORQUE stb-000-5 H

H

]

IP50mHOV104 1

SR-4190 214 SC

.4

.5 LIHITORQUE Ste-000-2 3

F 1P50eHOV105A 1.5/2 SR-4189 214 PC

.7

.7 LIMITORQUE Ste-000-5 F

F IP50mit0V1058 1.5/2 SR-4189 214 PC 1.7

.7 LIllITORQUE Ste-000-5 F

F IP50mHOV104 1

SR-4190 214 SC

.4

.5 LIHITORQUE stb-000-2 0

F 1P50mit0V1138 1

SR-4189 214 SC

.5

.h LIMITORQUE stb-000-5 F

F IP50mHOV114A 1

SR-4189 214 SC

.8

.4 LIMITORQUE stb-000-5 F

F IP56mit0V1148 1

SR-4189 214 SC

.5

.5 LIllITORQUE Ste-000-5 F

F IT23m!t0V031A

.5 SR-4341 214 SC

.5

.4 LIHITORQUE Ste-000-2 H

H IT23mHOV0318

.5 SR-4341 214

.SC

.5

.4 LIHITORQUE Ste-000-2 H

H 1T23 MRV 021A

.75 502444 191 SC 1.5 1.3 F

i 1T23 MRV 0218

.75 502444 191 SC 1.5 1.3 F

IT24mA0V001A 4

10.3.151 318 SC 4.8 3.4 COPES D-100-100 N

H IT24mA0V0018 4

10.3.151 318 SC 2.9 3.7 COPES D-100-100 H

H IT24mA0V004A 4

10.3.151 318 SC 1.9 1.2 COPES D-100-100 H

H IT24mA0V0048 4

10.3.151 318 SC 3.2 2.2 COPES D-100-100 H

11 1T44mA0V035A 72 R-1042-41 111 SC 2.7

.4 BETTIS T-316 SR2-H3 H

H

~

QUALIFICATION HILESTONES NOTES REVISION 5 -DECE!! DER 1982 i

A : REEVALUATION C0tPLETE

1. CL 2 Ate 3 VALVES < OR = 2 IN. ARE
5. PRESENT QUALIFICATION VALID 8 REQUEST FOR QUAL OR BIO ISSUED FLOOR-HOLkfTED (Et8TG-5 I FOR OPERATOR LOADS < OR = 3 G'S C zS/H RECOtt!EteATION TO LILCO
2. e a DC HOTOR. ALL OTHERS ARE AC HORIZONTAL AliD VERTICALIFt.ULTED)

D = QUAL DOC RECEIVED

3. CL 1 VALVES < OR a 1 IM. ARE
4. IF OlLY Ot!E LOAD IS GIVEN FCt j

E=HAR0 HARE I:00IFICATION REQ'D FLOOR-HOUNTED (EHTG-5)

THE OPERATOR. IT IS THE !!AXI:!Ull i

7 F zQUAL DOC APVD & FILED

4. 2/1 s 2 IN. CLASS 1

{

G zSQRT PAPER C0tFLETE 1

H : COPIES OF DOC TO DISTRIDUTION J

i s

77 j

_. _,.. _ _ _ _ _ _ _ _ _,,, _. _ _ _, _ - ~ _ _ _ _. _ _ _,. _. _ _.._--._ _

o JB O

O V

s V

SHOREHAH (MIT 1 RBPH LIST STONE & HEBSTER ENGINEE2ING CORPORATION RLAt DATE 12/20/82 JOB HUlBER 11400 1-50RT REACTOR BUILDItIG CATEGORY I PIPE HOUNTED EQUIPitENT RUN TIttE 13.24.25 LILCO DOCHET 50-322 ACTIVE BOP OU R IFICATION LEVEL (392 ITEttS)

PAGE 17 5

7 8

1 2

3 4

OPER LOAD-G'S OPE 2ATOR 6

QUAL STATUS

=

HARM PIPE QUAL SPEC LOC.

IAMBER SIZE REPT HD.

HOR VER SUPPLIER H00EL HO.

YOKE OPER IT44mA0V0358 72 R-1062-41 111 SC 5.2

.6 BETTIS T-316 SR2-It3 H

H IT46mA0V037A 72 CD75-35 Ill SC 1.0

.7 BETTIS T-316 SR2-H3 H

H IT44mA0V037B 72 CD75-35 111 SC

.8

.4 BETTIS T-316 SR2-It3 H

18 IT46mA0V038A 18 C076-82 172 FC 2.2 1.2 BETTIS 722C-SR-H3 H

H IT44mA0V038B 18 C074-82 172 SC 1.2 1.1 BETTIS 722C-SR-H3 H

H 1T46mA0V038C 18 CD74-82 172 SC 1.8 1.3 BETTIS 722C-SR-H3 H

H IT46mA0V0380 18 CD74-82 172 SC 1.3 1.2 BETTIS 722C-SR-H3 H

H IT44mA0V039A 18 CD74-82 172 PC 2.2 1.2 BETTIS 722C-SR-H3 H

H 1T46mA0V0398 18 CD76-82 172 SC 1.2 1.1 BETTIS 722C-SR-H3 H

11 IT46mA0V039C 18 CD76-82 172 SC 2.3

.8 BETTIS 722C-SR-H3 11 H

IT44mA0V0390 18 CD76-82 172 SC 1.8

.8 BETTIS 722C-SR-It!

H H

IT46mA0V078A 6

10.3.145 318 PC 2.5 1.5 COPES D-100-100 H

H 1T46mA0V078B 6

10.3.145 318 SC 2.3 1.3 COPES D-100-100 H

H i

l IT46mA0V079A 6

10.3.151 318 SC 3.7 1.4 COPES D-100-100 H

H l

1T46mA0V0798 6

10.3.151 318 SC 2.4 1.9 COPES D-100-100 H

11 1T46mTCV-022A 4

2-2R451 310 SC 1.2

.6 BECH 14-ICl-ES H

H IT46mTCV-0228 4

2-244S1 310 SC 1.0

.5 BECH 14-101-ES H

H IT46mTCV-023A 4

2-24451 310 SC 1.1

.2 BECH 14-101-ES H

ll IT46mTCV-0238 4

2-244S1 330 SC

.8

.8 BECH 14-101-ES H

H 1

QUALIFICATION HILEST0ftES NOTES REVIS10tt 5 -DECEll3ER 1982 A = REEVALUATION C0tlPLETE

1. CL 2 Ate 3 VALVES < OR z 2 IN. ARE
5. PRESENT QUALIFICATI0H VALID 8 = REQUEST FOR QUAL OR BID ISSUED FLOOR-HOUNTED (EHTG-5 )

FO't OPERATOR LOADS < OR = 3 G'S C =S/H REC 0!91EilDATI0tl TO LILCO

2. m a DC HOTCR. ALL OTHERS ARE AC HORIZOttTAL A!O VERTICAL (FAULTED)

D = QUAL DOC RECEIVED

3. CL 1 VALVES < Oil a 1 IH. ARE
6. IF Ott.Y OtlE LOAD IS CIVEtt F02 E=HAROHARE HODIFICATION REQ'D FLOOR-HOUNTED (EHTG-SI THE OPERATOR. IT IS THE ItAXI!?Jtt I

F = QUAL DOC APVD & FILED

4. 2/1 a 2 IH. CLASS 1 6 =SQRT PAPER CotFLETE H = COPIES OF DOC TO DISTRIBtJTION 15

J0

'l v

SHOREHAM UNIT 1 RDPH LIST STONE & HEBSTE2 ENGINEERING CORPORATION RUN DATE 12/20/02 JOB teACER 11400 1-SORT REACTOR BUILDING CATEGORY I PIPE HoutiTED EQUIPHENT RUN TIltE 13.24.25 LILCO 00CHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEtts)

PAGE 13 5

7 8

1 2

3 4

OPER LDAD G'S OPERATOR 6

QUAL STA10S HARN PIPE QUAL SPEC LOC.

HUtBER SIZE REPT HO.

HOR VER SUPPLIER lt00EL NO.

YCl:E OPER 1T46mTCV-024A 4

2-24451 310 SC

.9

.6 BECH 14-101-ES H

H 1T46mTCV-0248 4

2-24451 310 SC 1.1

.4 BECH 14-101-ES H

H IT46mTCV-025A 4

2-24451 310 SC 1.2

.7 BECH 14-101-ES H

H g

IT46mTCV-0258 4

2-24451 310 SC

.4

.5 BECH 14-101-ES H

H IT46mTCV-026A 4

2-24451 310 SC

.6

.1 BECH 14-101-ES H

H IT46mTCV-0268 4

2-24451 310 SC

.7

.5 BECH 14-101-ES H

H IT46mTCV-028A 2/3 2-24451 310 SC

.6

.5 BECH 14-101-ES H

H IT46mTCV-028B 2/3 2-24451 310 SC

.8

.5 BECH 14-101-ES H

H 1T46mTCV059A 2/3 2-24451A 310 SC 1.1

.6 BECH 14-101-ES 11 H

1T46mTCV059B 2/3 2-24451A 310 SC

.5

.5 BECH 14-101-ES H

H IT46mTCV060A 2/3 2-24451A 310 SC

.6

.7 BECH 14-101-ES H

11 IT46mTCV0608 2/3 2-24451A 310 SC

.5

.5 BECH 14-101-ES II H

IT47 MRV 037

.75 502644 191 PC 4.9 3.0 F

IT47 MRV 038

.75 502644 191 PC 4.9 3.0 F

IT48mit0V004 1

SR-6190 253 SC

.5

.4 LIHITORQUE Ste-000-2 0

F IT48mHOV031A 4

SR-6177 88V PC 2.9 1.3 LIllITORQUE Ste-00-5 H

H IT48mt10V0318 4

SR-6177 88V PC 6.1 1.8 LIHITORQUE S' B-00-5 H

H IT48mit0V032A 6

SR-6177 88V PC 4.5 2.7 LIHITORQUE Ste-00-7 1/2 H

H 1T48 mil 0V032B 6

SR-6177 88V PC 5.3 3.2 LIHITORQUE SIB-00-7 1/2 H

H

~

QUALIFICATION HILESTONES HOTES REVISION 5 -0ECEttBER 1902 l

A = REEVALUATION C0!!PLETE

1. CL 2 Are 3 VALVES < OR a 2 IH. ARE
5. PRESENT QUALIFICATION VALID B =REQUESI FOR QUAL OR BID ISSUED FLOOR-It0UNTED (EHTG-5 I FOR OPERATOR LCADS < 09 = 3 G'S C =S/H REC 0tetEt0ATION TO LILCO
2. e z DC ll0 TOR. ALL OTHERS ARE AC HORIZ0tiTAL Ato VERTICALIFAULTE03 D = QUAL DOC RECEIVED
3. CL 1 VALVES < OR a 1 IN. ARE
4. IF OtiLY OttE LOAD IS GIVEtt FCa E=HAROHARE HODIFICATION REQ'D FLOOR-190UNTED (EHTG-5)

T'tE OPERATOR. IT IS THE HAXIt!Ute I

F =eUAL 00C APVD & FILED

4. 2/1 a Z Ill. CLASS 1 G =SQRT PAPER C0t!PLETE

(

H = COPIES OF 00C TO DISTRIBUTION I

l l

l

'c

m.

_m O

O i

SHOREHAM UNIT 1 R8PH LIST STONE & HEISTER ENGINEE2ING CORPORATION RUN DATE 12/20/02 l

JOB NUtBER 11400 1-50RT REACTOR BUILDING CATEGORY I PIPE HOUNTED EQUIPMENT RUN TIttE 13.24.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEHS)

PAGE 19 l

l 5

7 8

1 2

3 4

OPER LOAD-G'S OPERATOR 6

QUt1 STATUS

(

HARK PIPE QUAL SPEC LOC.

IRABER SIZE REPT NO.

HOR VER StFPLIER tt00EL NO.

TCHE OPLR I

IT48ml10V033A 6

SR-6177 88V SC 4.2 1.5 LIMITORQUE SFB-00-5 H

H IT48eHOV0338 4

SR-4177 88V SC 4.9 1.3 LIHITORQUE.

stb-00-5 H

ll IT48att0V034A 6

SR-6177 88V SC 5.3 4.4 LIHITORQUE SFB-00-7 1/2 H

H IT48mHOV0348 4

SR-4177 88V SC 3.7 1.3 LIHITORQUE stb-00-7 1/2 H

H IT48mHOV035A 4

SR-4180 88V SC 4.2 2.8 LIMITORQUE stb-000-5 H

H l

IT48mHCV0358 4

SR-6180 88V SC 4.4 5.7 LIMITORQUE stb-000-5 H

H IT48mHOV037A 6

SR-4177 88V SC 4.7 5.8 LIMITORQUE stb-00-7 1/2 H

H l

IT48mHOV0378 6

SR-6177 88V SC 4.4 3.0 LIHITORQUE stb-00-7 1/2 H

H IT48 mil 0V038A 4

SR-6180 88V SC 4.1 2.0 LIHITORQUE Ste-000-5 H

H 1T48mtIOV0388 4

SR-6180 88V SC 5.0 1.9 LIHITORQUE stb-000-5 H

H IT48mHOV040A 4

SR-6177 88V SC 8.4 5.9 LIIIITORQUE stb-00-7 1/2 H

H 1" 3mit0V040B 6

SR-4177 88V SC 4.0 1.5 LIHITORQUE Ste-00-7 1/2 H

H 11 wmHOV041 4

SR-6180 88V SC 1.3

.7 LIMITORQUE stb-000-5 H

18 IT48mHOV042 4

SR-6180 88V SC 1.0 1.3 LIllITORQUE stb-000-5 H

H IT48mHOV043A 4

SR-6180 88V SC 2.9 2.5 LIMITORQUE Ste-000-5 H

H 1T48mHOV0438 4

SR-6180 88V SC 5.9 2.0 LIHITORQUE stb-000-5 H

H

{

1T48mHOV044A 4

SR-6180 88V SC 4.0 1.f LIHITORQUE stb-000-5 H

ll l

1T48 mil 0V0448 4

SR-6180 88V SC 4.9 1.8 LIHITORQUE Ste-000-5 H

H 1T48mPCV143A

.25 492 SC 1.5 1.3 B

~

QUALIFICATI014 HILESTONES NOTES REVISION 5 -DECEl: DER 1982 i

t A =REEVALUA110H C0lFLETE

1. CL 2 AFB 3 VALVES < OR a 2 IN. ARE
5. PRESENT QUALIFICATI0tl VALIO j

B = REQUEST FOR QUAL OR BIO ISSUED FLOOR-HOUNTED (EHTG-5 )

FOR GPERATCR LCADS < OR = 3 G'S 1

C =S/H REC 0tetENDATI0tl TO LILCO

2. e a DC HOTOR. ALL OTHERS ARE AC HORIZO: ITAL Af D VERTICALIFt.LLTEDI D = QUAL DOC RECEIVED
3. CL 1 VALVES < OR a 1 IN. ARE
6. IF OtLY ONE LOAD IS GIVEll TCR i

E=HARDHARE HODIFICATION REQ'O FLOOR-It0UNTED (EHTG-5)

THE OPERATOR. IT IS Tiit itAXII:U:t l

C F = QUAL DOC APVD & FILED

4. 2/1 = 2 IN. CLASS 1 G =SQRT PAPER CollPLETE i

H = COPIES OF DOC TO DISTRIBUTION i

i 3

II

II n

\\v/

(s SHOREHAH tRIIT 1 RDPH LIST STONE & HEBSTE3 ENGINEE!!NG CORPORATION Rt24 DATE 12/20/82 JOB til2BER 11600 1-50RT REACTOR BUILDIllG CATEGORY I PIPE HoutfTED EQUIPHEffT RUH TII:E 13.24.25 LILCO DOCHET 50-322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEllSi PACE 20 5

7 8

1 2

3 4

OPER ?.0AD-G'S OPERAT04t 4

CUAL STATUS HARN PIPE QUAL SPEC LOC.

lAABER SIZE REPT HO.

HOR VER SUPPLIER HODEL NO.

YOME ONR IT48mPCV1438

.25 492 SC 1.5 1.3 B

1T48mPCV143C

.25 492 SC 1.5 1.3 B

1T48mPCV143D

.25 492 SC 1.5 1.3 B

IT48m,PCV1444

.25 492 SC 1.5 1.3 8

1T48mPCV1448

.25 492 SC 1.5 1.3 8

IT48mPCV145A

.25 492 SC 1.5 1.3 B

IT48mPCV1458

.25 492 SC 1.5 1.3 D

1T48mPCV145C

.25 492 SC 1.5 1.3 B

IT48mPCV145D

.25 492 SC 1.5 1.3 B

IT48mPCV146A

.25 492 SC 1.5 1.3 D

1T48mPCV1468

.25 492 SC 1.5 1.3 B

IT48 MRV 017A 3

502644 191 SC 1.9

.7 F

IT48 MRV 0178 3

502644 191 SC 3.7 3.1 F

IT48mSOV126A

.75 IR5265683271 400 SC 1.5 1.3 H

1T48mSOV126B

.75 HR5265683271 600 SC l'.5 1.3 H

IT48mSOV127A

.75 IR5265683271 400 SC 1.5 1.3 H

i IT48mSOV1278

.75 IR5265683271 400 SC 1.5 1.3 H

IT48mSOV128A

.75 195265683271 500 SC 1.5 1.3 H

1T48mSOV1280

.75 195245683271 600 SC 1.5 1.3 H

~

QUALIFICATION tlILESTottES NOTES REVISION 5 -DECEtBER 1982 4

A = REEVALUATION CollPLETE

1. CL 2 AfD 3 VALVES < OR z 2 IH. ARE
5. PRESEffT QUALIFICATI0tt VALID B = REQUEST FOR QUAL OR DIO ISSUED FLOOR-It0UrtTED (EHTG-5 3 FOR OPERATOR LOADS < OR = 3 G'S C =3/H REColttEt0ATION TO LILCO
2. e = DC 110 TOR. ALL OTHERS ARE AC HORIZOHTAL AfD VERTICAlt FAltTED) d 1

D = QUAL DOC RECEIVED

3. CL 1 VALVES < OR = 1 IN. ARE
6. IF OrLY Of(E LOAD IS GIVEtt iCR

]

E=HARDl4ARE flODIFICATION REQ'O FLOOR-It0UNTED (EHTG-53 lite OPERATOR. IT IS TliE ItAXIntUM

~

F = QUAL DOC APVD & FILED

4. 2/1 = 2 IH. CLASS 1

]

G =SQRT PAPER CollPLETE H = COPIES OF DOC TO DISTRIBUTION i

N SHOREHAH UNIT 1 RBPH LIST STONE & HEISTE2 ENGINECING CORPORATION RUN DATE 12/20/32 J00 PAREER 11400 1-50RT REACTOR BUILDING CATEGORY I PIPE HOW4TED EQUIPHEHT Rutt TIllE 13.24.25 LILCO DOCHET 50 322 ACTIVE BOP QUALIFICATION LEVEL (392 ITEllSI PAGE 21 5

7 8

1 2

3 4

OPER LOAD-G'S OPERATOR 4

QUAL STATUS HARM PIPE QUAL SPEC LOC.

IARBER SIZE REPT NO.

HOR VER SUPPLIER IODEL HD.

YO!;E CPiR IT48mSOV129A

.75 HR5265683271 400 SC 1.5 1.3 H

1T48mSOV1298

.75 19 5245483271 400 SC 1.5 1.3 H

IT48mSOV130

.75 HR5265683271 400 SC 1.5 1.3 H

IT48mSOV131

.75 695265683271 400 SC 1.5 1.3 H

IT48mSOV136A

.75 HR5265683271 400 SC 1.5 1.3 H

i 1T48mSOV1368

.75 995245683271 400 SC 1.5 1.3 H

IT48mSOV137A

.75 695265483271 400 SC 1.5 1.3 H

IT48mSOV1378

.75 FRS265683271 400 SC 1.5 1.3 H

i 1Z93mFCV011A

.25 493 SC 1.5 1.3 B

1Z93mFCV0118

.25 493 SC 1.5 1.3 8

{

IZ93aPCV010A

.25 492 SC 1.5 1.3 B

1Z93mPCV010B

.25 492 SC 1.5 1.3 B

i t

i 1

4

~

j QUALIFICATION HILESTONES NOTES REVISIOt3 5 -DECE!IBER 1902 A zREEVALUATION COlFLETE

1. CL 2 Ate 3 VALVES < OR = 2 IH. ARE
5. PRESENT CUALIFICATI0tl VALID 8 = REQUEST FOR QUAL OR BID ISSUED FLCOR-HOUNTED EEHTG 5 I FOR OPERATC3 LOADS < CR z 3 G'S C zS/H REcolstEtOATION TO LILCO
2. m a DC ICTOR. ALL OTHERS ARE AC HORIZOrtTAL AfD VERTICALIFAULTED) 1 0 = QUAL DOC RECEIVEO
3. CL 1 VALVES < OR a 1 IH. ARE
4. IF OtLY OilE LOAD IS GIVEti FCQ l

E HARDHARE HODIFICATION REQ'D FLOOR-HOUNTED (EHTG-SI THE OPERATORe IT IS THE IfAXII:UN l

F = QUAL DOC APVD & FILED

4. 2/1 a 2 IH. CLASS 1 G zSQRT PAPER C0tFLETE i

H = COPIES OF DOC TO DISTRIBUTION i

a OI

ia o

m Sit 0REHAH tMIT 1 GE LIST STotiE & HEBSTER EttGIrlEERING CORPORATION RUN DATE 12/20/02 JG3 tiU!BER 11400 1-SORT GENERAL ELECTRIC CATEGORY I EQUIPl!EtIT RUti tit!E 13.22.24 LILCO DOCHET 50-322 ACTIVE NSSS QUALIFICATI0H LEVEL (151 ITDIS)

PACE 1 ilARM EQUIPt!!!(T GE BLOG AVAIL QUAL QUAL TYPE SAFETY CUAL NUtDER DESCRIPTIDH HO.

vet 00R ELEV IllSP REPT ltETH FREQ ttTtG FUi!C STATUS ID21mA0V001 ISOLATI0t4 VALVE-Its B21F022 R0ct0tELL SC002 YES NEDE-24122-2 SA 8

P4 CSellS G

1821mA0V082 ISOLATION VALVE-HS B21F028 ROClOIELL SC082 YES NEDE-24122-2 SA 8

P4 CS ells G

1821mD-003 CollDEtt3IllG CHAT! DER B210002 GE SC080 YES DRF-A00794-11 SA 606 P

HS.CS G

1021 0-004 C0tiDEllSING CHA!OERS 8210004 GE SC080 YES DRF-A00794-11 SA 40+

P2 HS.CS G

II21mD-00S C0f0EttStriG CHAIDERS 8210006 GE SC080 YES DRF-A00794-11 SA 60+

Pld HS,CS G

1821mFE 002 FLOH ELEttEin D21H005 PERHLITIT SC067 YES SA P4 H

B/Z 1821mPS 020 PRESSURE SHITCH B21N015 BARHSDALE C0037 YES DV164C5359 SAT 33+

F4 H

D IB23 MRV 072 RELIEF VALVE B21F013 TARG ROCH PC099 YES VPF-5485-3-1 IBT 40+

P11 CS G

1811mTE 003 lEt!PERATURE ELEttENT B21N040 CROUSE-HI T083 YES DV159C4520 SAT 100 P

H D

IDElmTE 043X TEl?ERATURE ELEttENT B21H016 PYC0 T059 YES DV164C5359 SAT 40+

F4 N

D 1021mTE 043Y TEHPERATURE ELEttENT B21tt010 PYC0 T082 YES DV145C3004 SAT 40+

F4 H

D ID2leTE 059 TEtIPERATURE ELEHENT B21tiO14 PYC0 T059 YES DV19503224 SAT 40+

F4 H

D 1031mFE 010 PECIRC FLOH ELEH B31tt013 BIF SC080- YES SA P2 H

B/Z 1031stt0V031 RECIRC SUCTION VALVE B31F023 ANCHOR SC017 YES 385HA661 SA 41 P2 H

G 1831mit0V032 RECIRC DISCliARGE VALVE B31F031 A!1CHOR SC014 YES VPF2009-40 SA/DA 100 P2 H

8 1831mP- 001 RECIRC PUtp & HOTOR B31C001 BJ/GE PC070 YES 206033C001-HS-1 SA 40+

P2 H

G ID31mTE 025 TEt9ERATURE LLEttENT B31H023 CROUSF-HI PCO65 YES DV159C4520 SAT 10 P2 11 D

IC11mA0V081 ItCU DIAPitRACH VALVL C11F010 moi "C078 YES SA P

CS.HS B

IC114A0V002 HCU DIAPitRAGil VALVE C11F911 t001 SC040 YES SA P

CS,HS B

CD =CCtTTROL DLDG P = PIPE HOUNTED SBT=SIttGLE FREQUErlCY QUALIFICATI0tl itILESTOt!ES REVISICN 5 -DECEICER 1902 i

CS CCLD SitUT Dotti PC =PRittARY C0t4T.

BIAXIAL TESTIllG A rREEVALUATIort CCttPLETE I

~ DA *DYHAHIC AtlALYSIS PL : PEDESTAL SC zSEcotIDARY CottT.

B zREQUEST FCR REQUAL OR CID ISSUED I;0TE: IIUTCER Iti j

F = FLOOR l!OUt4TED QP zGUALIFIED BY

/ mLOCATED ON CONT.

C =$/H REC 01:ttEtaATI0tl 10LILCO

' TYPE IITit0* CCLt?.:tl IS HS SHOT STArIDBY PIPItiG AftALYSIS liALL D mCUAL DCC RECEIVED QUA!4TITY OF ITEttS.

IIDTat!ULTI-FREQUENCY RH =RADHASTE T =3tAIN STH. TUtit1EL E zHARDHARE It001FICATICH REQ'D

]-

P' AXIAL TESTIttG SA zSTATIC ANALYSIS H =ttEITHER CS OR HS F zQUAL DOC APVD & FILED 3

itST:

'I-FREQUEtiCY SAT = sit 4GLE FREQUENCY Z sPASSIVE ITEtt G zSQRT PAPER CollPLETE

-..JLE AXIAL TESTING SINGLE AXIAL TESTING (SQRT PAPER HDT H aCOPIES OF DOC TO DISTRIDUTION REQ'D)

)

4

C

. (41:..

.+

5-

):

'U*

l SH0vlEHAH LMIT 1 GE LIST STONE & ltEBSTER ENGINEERING CORPORATION RUN DATE 12/20/02 JOB Nt3BER 11600 1-50RT GENERAL ELECTRIC CATEGORY I EQUIPHENT RUN TIlfE 13.22.21

(-

LILCO DOCHET 50-322 ACTIVE ftSSS QUALIFICATION LEVEL (151 ITEMS)

PAGE 2 HARN EQUIPHENT GE BLDG AVAIL QUAL QUAL.

TYPE SAFETY CU.".L IAREER DESCRIPTION HO.

VEtWOR ELEV INSP REPT HETH

.FREQ HTliG FU:tC STATUS

},

IC11sHCU-01 CRD HYDRA CONT UNIT C110001 GE SC078 YES 383HA853 HST 2

137 CS.HS G

I IC11mLS 049 LEVEL Sh1TCH C11N013 HAGNETROL SC078 YES SHIP LOOSE SAT 30+

F2 F

[

IC11mLS 095 LEVEL SHITCH C11N013 HAGNETROL SC078 YES DV159C4361 SAT 30+

F6 N

D IC11mSOV044 HCU SOLEHOID VALM C11F009 ASCO SC043 P

CS.HS B

e IC41mEV 010 EXPLOSIVE VALVE C41F004 CONAX SC112 YES VPF3394-34-2 SBT 35+

P2 N

G IC41mP-024 STDBY LIQ PUtFSHTR C41C001 UNION Ptm SC113 YES VPF-E317-2-2 SBT 60+

F2 N

G 1C41mPI 002 PRESSURE ItOICATOR C41R003 ROBT SHAM SC112 YES OV163C1184 SAT 33+

F H

D O

ICt1mPT 002 PRESSURE TRANSHITTER C41N004 POSEHOLMT SC112 YES DV143C1563 SAT 3

F N

O IC41mTM-003 SLC STORAGE TAtM C41A001 LAHCO SC113 YES RA542/C41-22 SA 59 F

N G

IC41mTH-150 SLC ACCUHULATORS C41A003 HYDRA CON SC097 YES DRF C41-22 SA N/A P2 N

G

(

IC41mT5001A TLIP SHITCH C41N003 HEED INST SC112 SHIP LOOSE SAT 60+

F D/Z U.

IC51mTIP-004 TIP VALVE GUIDE T C51J004 GE SC073 YES DRF-A00992-H SAT 60+

F4 H

D

~

IC61mCE 016 Cote TRANSilITTER C61N008 BALL $t$AUG SC030 YES DV163C1544 SAT 3

P H

D t

IC61mFT 001 DIFF PRESS XHTR C61N001 ROSEH0tMT SC008 YES DV163C1560 SAT 50 F

N D

j 1

1C61mPN'.-RSP REHOTE SHT DH Pte.

C61P001 GE SC063 YES SAI-029QA80PA-B HDT 14 F

H D

1C61mPT 004 PRESS TRANS C61N004 BAILEY SC079 YES DV163C1186 SAT 33+

F N

D IC71*PS 003 PRESSLRE SHITCH C71N003 BARHSDALE C8037 YES DV164C5359 SAT 33+

F4 H

D

_j IE11mE-034 RHR HEAT EXCNANGERS E118001 PERFEX CP SCC 08 YES DRF E11-1 DA 14 F2 HS.CS G

.?

IE11mFE 001 RHR FLOH ORIFICE E11N014 VICH SIHS SC057 YES SAI-DJC2 SA 60+

P2 HS.CS F/Z l

CB = CONTROL BLDG P : PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVISION 5 -DECEICER 19c2 CS = COLD SHUT DOHN PC =PRIHARY CONT.

BIAXIAL TESTING A =REEVALUATI0tl C0!PLETE

~

l DA =DYNAHIC ANALYSIS PL = PEDESTAL SC =SEC0tOARY CONT.

B = REQUEST FOR REQUAL OR BID ISSUED tt0TE : t;U:.7E'l Its F =Ft00R HOUNTED QP = QUALIFIED BY

/ = LOCATED ON CONT.

C =S/H REC 0ttt[t:DATION TOLILCO

' TYPE HTt;S* CCLt?.nl IS HS = HOT STAICBY PIPING ANALYSIS HALL D = QUAL DOC RECEIVED QUAtlTITY OF IIEtiS.

CT=HULTI-FREQUEt4CY R68 RA0 HASTE T =tlAIN STH. TtMfEL E =HARDHARE HODIFICATION REQ'O BIAXIAL TESTING SA = STATIC ANALYSIS H =NEITHER CS OR HS F = QUAL DOC APVD & FILED HST HULTI-FREQUEllCY SAT = SINGLE FREQUENCY Z = PASSIVE ITEH G =SQRT PAPER C0ts'LETE SINGLE AXIAL TESTING SINGLE AXIAL TESTING ISQRT PAPER NOT H = COPIES OF DOC TO DISTRIBUTION

~

REQ'DI

~

j 9

?

j

.,e'

! G

- ~i.

gg 4

l SHORENAH UNIT 1 GE LIST STONE & HEBSTER ENGINELRING CORPORATION Rutt DATE 12/20/82 D

JOB NUlBER 11600 1-SORT GEtIERAL ELECTRIC CATEGORY I EQUIPitENT RUrl TIttE 13.22.24 LILCO DOCHET 50-322 ACTIVE NSSS QUALIFICATION LEVEtt151 ITEttS)

PAGE 3 HARK EQUIPHENT GE BLDG AVAIL QUAL QUAL TYPE SAFETY CU?L HullBER DESCRIPTION NO.

VEte0R ELEV INSF REPT ttETH FREQ HTitG TUNC STATUS y

1E11mFE 004 RHR FLOH ORIFICE E11H012 VICH SIMS SC093 YES SAI-SQRT-DJC5 SA 60+

P CS

'F/Z IE11mFT 004 DIFF PRESS XHTR E11H013 ROSEHOUNT SC078 YES DV163C1560 SAT 50 F

t!

D 0

IE11mFT 006 DIFF PRESS TRAtl5 E11N007 ROSEHOUtif SC008 YES DV143C1560 SAT 50 F2 N

O 1-IE11mLT 002 LEVEL XHTR E11H008 BdlTON SC024 YES DV145C3156 SAT 100 F2 N

D s

IE11mP-014 RH4 PtAPS SHOTORS E11C002 BJ/GE SC008 YES DRF E11-11 DA 10 F4 HL.CS G

IE11mPS 134 PRESSURE SHITCH E11N014 BARKSDALE K006 YES SHIP LOOSE SAT 33+

F4 N

D IE11mPS 135 PRESSURE SHITCH E11N020 BARHSDALE SC006 YES SHIP LOOSE SAT 33+

F4 14 D

IE11mTE 014 TEtr ELEHENT E11N009 PYC0 SC023 YES DV145C3224 SAT 60+

F2 H

D IE11mTE 015 TEtr ELEHENT E11NO30 PYC0 SC023 YES DV145C3224 SAT 60+

F2 N

D IE21mFE 002 CS FLOH ORIFICE E21H002 VICH SIHS SC047 YES SAI-DJC4 SA 60+

P2 LS t'/Z 1E21mP-013 CS PUlFS & HOTORS E2]C001 BJ/GE SC008 YES DRF E21-53 DA 12 F2 CS G

i 1E21mPISO98 PRESS IteIC SHITCH E21H010 ROBT SHAH SCOO8 YES DV163C1165 SAT 33+

F2 tl G

ff IE21mPS 012 PRESSURE SHITCH E21N008 BARMSOALE SC008 YES SHIP LaOSE SAT 33+

F2 N

G 1E21mPS013 PRESSURE SHITCH E21H009 BARMSDALE SC008 YES SHIP LOOSE SAT 33+

F2 N

G i[

IE32aBLO-13 OUTBD HSIV LCS BLOHER E32C002 GE SC074 YES VPF3830-14-1 SBT 60+

F2 N

G

[

IE32mBLO-14 ItED HSIV LCS BLOHER E32C001 GE SC076 YES VPF3C30-14-1 SBT 60+

F N

G t'

1E32mFE 037 HSIV LEAN TO LPH E32N006 3 & N INS SC067 DV163C110707 SAT 3

P4 N

D/Z;

?

1E32mFE037 FLOH HETER E32N006 SSN SC065 SHIP LOOSE 30+

P4 D

L 0

3 1E32mHC-053 HSIV LCS HTR E328001 GE SC078 YES VPF3830-33-1 IBT 15 P4 il G

l CB = CONTROL BLDG P = PIPE HOUNTED SBT=SINCLE FREQUEtlCY QUALIFICATION HI?.5 STONES REVISI0tl 5 -DEC[tCI.R IM2 CS = COLD SHUT DOF#f PC =PRINARY C0 tit.

BIAXIAL TESTING A =REEVALUATI0tt COlFLETE DA =DYNAHIC AtlALYSIS PL = PEDESTAL SC =SEC0tOARY CONT.

B = REQUEST FCR REQUAL OR BID ISSUED IGTE: fiU:FER Ill 1

F = FLOOR HOUNTED GP = QUALIFIED BY

/ = LOCATED ON CCitT.

C =S/H RECO'It!EtDATIOrt TOLILCO

' TYPE ltTN3' Celt"O IS t

HS = HOT STAtOBY PIPING ANALYSIS HALL D = QUAL DOC RECEIV[D QUAtiTITY OF ITE!!S.

63T=ltULTI-FREQUENCY RH =RADHASTE T =HAIN STM. TUtilEL E =HARDHARE IIODIFICATION REQ'D BIAXIAL TESTING SA = STATIC ANALYSIS H =NEITHER CS OR 'tS F =QU/.L DOC APVD & FILED HST=11ULTI-FREQUEllCY SAT = SINGLE FREQUENCY Z = PASSIVE ITEN 6 =SQRT PAPER CCIFLETE 4

2 SINGLE AXIAL TESTING SINGLE AXIAL TESTING (SQRT PAPER NOT H = COPIES OF DOC TO DISTRIBUTION REQ'D) s.,

s 1

j u

7-

~ _

,~

.Q,.

5' SHOREHAM LRtIT 1 GE LIST STONE & HEBSTER ENGINEERING CORPORATION RUN DATE 12/20/82 JOB NtABER 11600 1-SORT GENERAL ELEC1RIC CATEGORY I EQUIPitENT RUN TIttE 13.22.24 LILCO 00CHET 50-322 ACTIVE HSSS QUALIFICATION LEVEL (151 ITEtts)

PAGE 4 HARK EQUIPitENT GE BLDG AVAIL QUAL QUAL TYPE St.FETY CUAL

.U.

tAJimER DESCRIPTION HO.

VEtOOR ELEV IttSP REPT llETH FREQ HTilG FU;;C STATUS

(

i 1E32mPDT035 DIFF PRESS TRANS E32N059 ROSEHotRIT SC063 YES DV163C1561 SAT 50 F

N D

I f.

o 1E32mPT 033 GAGE PRESS TRANS E32N05$ ROSEHOUNT SC063 YES DV163C1564 SAT 50 F

N D

{

1E32mPT 034 ABS PRESS TRANS E32N056 ROSEt:0UNT SC063 YES DVI53C1558 SAT 50 F

N D

  • /.,

'3-1E41mFE 003 FLOM ORIFICE E41N007 VICH SIHS SC021 YES SAI-DJC3 SA 40+

P H

F/Z 1E41mL5091 LEVEL SHITCH E41N014 HAGNETROL SC016 YES DV159C4361 SAT 4

F N

O

[

1E41mLSO92 LEVEL SHITCH E41H015 HAGNETROL,5C027 YES DV159C4294 SAT 1

F2 N

D e.,

1E41mLS0934 LEVEL SMITCH E41N002 HAGNETROL YARD YES DV159C4294

'.;AT 1

F N

D 1E41mL50938 LEVEL SHITCH E41N003 HAGNETROL YARD YES DV159C4294 SAT 1

F H

D 1E41mP-016 HPCI PtAP4800 STER E41C001 PACIFIC P SC008 YES VPF-2740 -180-1 DA 23 F

H G

1E41mTE053 TEtPERATURE ELEHENT E41H02% PYC0 SC034 YES DV195C3224 SAT 40+

F2 N

D P

1E41*TE054 TEtPERATURE ELEMENT E41N028 PYC0 SC025 YES DV145C3224 SAT 60+

F2 il D

it41mTE055 TEtPERATURE ELEMENT E41H029 PYC0 SC017 YES DV145C3224 SAT 40+

F2 N

D j

1E41mTE056 TEtPERATURE ELEHENT E41N030 PYC0 SC063 YES DV145C3224 SAT 60+

F2 N

D

., r 1E4ImTI141 TEtr IteICATOR E41R002 NEED SC008 YES DV145C3103 SAT 100 P

H D

d *-

(

i IE41mTU-002 HPCI TURBINE E41C002 TERRY SC006 YES teT F

N D

1E51mFE 003 FLOM ORIFICE E51N001 VICH SIMS SC018 YES SAI-DJC1 SA 60+

P HS F/Z 1E51mL5091 LEVEL SHITCH E51H010 MAST;2 COL SC006 YES DV159C4361 SAT 4

F H

D 1E51mP-015 RCIC PUIP E51C001 BINGHAH SC008 YES DRF E51C00112 SA 24 F

HS G

]

s/

IE51mTE052 TEtPERATURE ELENENT E51H011 PYC0 SC025 YES DV145C3224 SAT 60+

F2 N

D

. k C3 CONTROL BLDG P : PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVIS10tl 5 -DECEl'3ER 1902 1

CS =COLO SHUT Dot 04 PC PRIttARY ColsT.

BIAXIAL TESTING A mREEVALUATIOta CCitPLETE s-

~

3 DA =DYHAHIC ANALYSIS PL zPEDESTAL SC zSEC0tCARY C0 tit.

B = REQUEST FOR REQUAL OR BID ISSUED I:0TE: tiU:CER Iti j

F = FLOOR HOUtITED QP =QUALIFTED BY

/ = LOCATED ON CONT.

C zS/H REC 0ft!!Et!DATION TOLILCO

' TYPE flTt:G' CCLU;;*I IS 4

HS = HOT STAPOBY PIPING ANALYSIS HALL D zQUAL DOC RECEIVED QUAtiTITY OF ITEt:3.

l teTzHULTI-FREQUENCY RH =RADHASTE T milAIN STH. tut 2tEL E zHARDHARE 110DIFICATION REQ'D l

BIAMIAL TESTING SA rSTATIC ANALYSIS N =HEITHER CS OR HS F zQUAL DOC APVD & FILED HST=HULTI-FREQUENCY SAT = SINGLE FREQUENCY Z zPA3SIVE ITEN G zSQRT PAPER C0!!PLETE 4

l, SINGLE AXIAL TESTING Sla:GLE AXIAL TESTING (SQRT PAPER NOT H zCOPIES OF DOC TO DISTRIBUTIDH REQ'D) 1 j

i 1

l L

' t.

i se

s. -

JI

\\

).

J, -

SHOREHAN t#11T 1 GE LIST STONE & HEBSTER ENGINEERING CORPORATION RUN DATE 12/20/82 JOB NUtBER 11600 1-50RT GENERAL ELECTRIC CATEGORY I EQUIPflENT RUtf TIllt 13.22.24 LILCO DOCHET 50-322 ACTIVE NSSS QUALIFICATION LEVELt151 ITEltS)

PAGE 5 Y

HARN EQU1PHENT GE BLOG AVAIL QUAL QUAL TYPE SAFETY CU?,L HullBER DESCRIPTION NO.

VElEOR ELEV INSP REPT HETH FREQ HTliG FUtic STATUS

{

s 1E51mTE053 TEIFERATURE ELEHENT E51N022 PYC0 SCO27 YES DV145C3224 SAT 60+

F2 N

D 1E51mTE054 TEtFERATURE ELEHENT E51N023 PYC0 SC063 YES DV145C3224 SAT 60+

F2 N

D

[ '**

'}

.' 's 1E51mTE055 TEtPERATURE ELEllENT E51N025 PYC0 SC066 YES DV145C3224 SAT 60+

F4 il D

1E51mTE056 TEfFERATURE ELEllElfr E51N026 PYCO SC066 vfS DV195C3224 SAT 60+

F4 H

D e

IE51mTI141 THERHONETER E51R005 ROBT SHAN SC008 DV145C3103 SAT 100 P

tl D

IE51mTU-005 RCIC TURBINE E51C002 TERRY SC006 YES VPF3622-19(11-2 SA/IET 15 F

HS G

i IF11mTO-005 FUEL PREP HACHINE F11E001 GE SC176 YES DRF F0000002-3 DA N/A F2 N

G

~

~

1F11mTO-006 GEN PURPOSE GRADPLE F11E011 GE SC176 YES DPF139F11E011L SA N/A F3 N

.G IF13mSL-001 DRYER 8SEP SLING F13E008 CAL PAC SC176 YES DRF F13-9 SA WA F

N G

IF13mTO-016 HEAD STR0tlGDACH F13E009 LAHC0 SC176 YES DRF F13-11 SA WA F

N G

.I

(

IF14mTO-029 CONT ROD GRAPPLE F14E002 GE SC174 YES DRF139F14E002H SA N/A F

N G

IF35mCRN-009 REFUEL PLTF ASSY F15E003 STERN ROG SC176 YES DRFF00000022 DA WA F

H G

IF36mC5H-01 DEF F STRG CCriTAIN F16E009 GE SC151 YES 139F16E009H1 DA 1

F8 ft G

1F16mRAM-025 POISON CURTAIN F16E015 BtF SC151 YES DRF F16-00009-1 DA 1

F14 N C

T IF16mRAH-09 FUEL RACH(IH VESSL)

F16E006 VOTAH-SC174 DA F2 N

D

~

i IF16mRAN-10 STRG RACHECR&DEF FI F16E004 GE SC137 YES DRF F16-0003 DA 13 F3 N

G IF16mRAN-11 NEH FUEL STRG RACHS FISECU7 GE SC151 YES DRF F00-00002 DA WA F17 tl G

I 1G33mFE 011 ORIFICE FLANCE G33NO35 VICH SIHS SC SHIP LOOSE SA 60+

P F/Z i

1G33mFE 013 ORIFICE FLANGE G33H011 VICH SIMS SC SHIP LOOSE SA 60+

P F/Z I

i

.3 CB CONTROL BLDG P zPIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILESTONES REVISIort 5 -DEttit:K't 1702 CS : COLD S!!UT DOHN PC =PRIttARY CONT.

BIAXIAL TESTING A mREEVALUATI0tt C0!!PLETE

~ DA :DYNAHIC ANALYSIS PL :PEDCSTAL SC =SEC0t DARY CONT.

B zREQUEST FOR REQUAL OR BID ISSUED f!3TE: I;U:CER Ira F = FLOOR HOUNTED QP zQUALIFIED BY

/ = LOCATED Ott CONT.

C zS/H RECO:lltEtiDATI0ft TOLILCO

' TYPE tlTI:G' CCLL'tEl IS HS = HOT STANDBY PIPI% ANALYSIS HALL D QUAL DOC RECEIVED QUAtlTITY OF ITIt!S.

RTzifULTI-FREQUENCY RH zRADilASTE T zHAIN STH. TUlt4EL E mHAR0ilARE IIDOIFICATION REQ'D BIAXIAL TESTIllG SA = STATIC ANALYSIS N *HEITHER CS OR HS F sQUAL DOC APVD & FILED

  • i '

HST=tlLt.TI-FREQUENCY SAT = SINGLE FREQUENCY Z : PASSIVE ITEN 6 =SQRT PAPER Cat lPLETE SINGLE AXIAL TESTING SINGLE AXIAL TESTING (SQRT PAPER P'OT H COPIES OF DOC TO DISTRIBUTION REQ'D) 3 j

i.

.f.

i' k

..' I.-

J gg

?

- - - ----- - - ~

~

-(.

j-y SHOREHAH IMIT 1 GE LIST STONE & HEBSTER ENGINEERING CORPORATION RUN DATE 12/20/02 JOB flulBER 11600 1-50RT GENERAL ELECTRIC CATEGORY I EQUIPilEllT RUtl TIllE 13.22.M LILCO DOCHET 50-322 ACTIVE HSSS QUALIFICATION LEVELt151 ITEHS)

PAGE 6 HARN CQUIPilENT GE BLDG AVAIL QUAL QUAL TYPE SAFETY CUf,L PAJtBER DESCRIPTI0li HD.

VEtOOR ELEV INS?

REPT HETH FREQ IITHG FUNC STATUS

!l It33mFE012 ORIFICE FLANGE G33N040 VICH SIHS SC SHIP LOOSE SA 40+

P F/Z 1233mFT012 DIFF PRESS TRAtt$

G33N041 ROSEH0lMT SC100 YES DV145C3240 SAT 50 F

N.

D

'j 1G33mTE020E TEtPERATURE ELEHENT 633N042 PYC0 PC97 YES SHIP LOOSE SAT 10 F

H, D

,5 1G33mTE071 TE!PERATURE ELEHENT G33H016 PYCO SC134 YES DV195C3224 SAT 40+

F4 ft D

1H11mPPL-601 REAC& CORE COOL BB N11P401 GE CB063 YES SAI-0290A80PA-B IET 14 F

HS.CS G

IH11mPtL-402 RHCU & RECIRC BN H11P602 GE CB043 YES SAI-0290A80PA-B HBT 14 F

HS'.CS G

[,'

IH11mPit-603 REACTOR CONTROL B H11P603 GE C5043 YES SAI-029QA80PA-B teT 14 F

HS.CS

~

'8*

G 1H11mPtL-400 PHR RANGE NEUT CA H11P408 GE CB063 YES tST F

N D

, g 1H11mPit-409 TRIP SYS A RPS VB H11P409 GE CB043 YES SAI-029QA80PA-B fBT 22 F

HS.CS

G

.i 1H11mPtL-411 TRIP SYS B RPS VB H11P411 GE CB043 YES SAI-029QA80PA-B fBT 22 F

HS.CS G

1H11mPtL-412 FH & RECIRC INSTR H11P612 GE CB063 YES SAI-0290A80PA-B teT 19 F

N G

1H11mPit-613 PROCESS INSTR CAB H11P613 GE C8063 YES SAI-0290A80PA-B IBT 14 F

HS.CS G

,,.i ',

I l

IH11mPIL-414 HSS TEtr LH DET VB H11P614 GE C8063 YES SAI-029QA80PA-B fBT 22 F

N G

~

1H11mPit-417 DIV 1 RHR RFLAY VB H11P417 GE CB044 YES SAI-0290A80PA-B DET 19 F

HS.CS G

r.

1H11mP!L-618 RHR RELAY VB H11P418 GE CB044 YES SAI-029QA80PA-B HBT 19 F

HS.CS G

1H11mPit-620 HPCI FELAY VERT BD H11P620 GE CB044 YES SAI-029QA80FA-B fBT 14 F

H

.G i

r, l

1H11mPtL-621 IC RELAY VERT BD H11P421 GE CB044 YES SAI-029QA80PA-B IST 14 F

ltS.CS G

~ -

j 1H11mPst-422 ItBD ISO V RELAY VB H11P622 GC CB044 YES SAI-0290A80PA-B FET 21 F

CS G

IH11mPtL-623 OUTBD ISO V REL V6 H11P623 GE CB044 YES SAI-0290A80PA-B teT 21 F

CS G

l t

'.s l

CB = CONTROL BLDG P = PIP! HOUNTED SBT= SINGLE FREQUENCY QUALIFICATION HILEST0 ties REVISI0tl 5 -DECEIOEf7 1902 CS = COLD SHUT 00184 PC :PRIllARY CCHT.

BIAXIAL TESTING A =REEVALUATI0f t CO*PLcTE

  • .S

~

DA =DYttAHIC ANALYSIS PL :PIDESTAL SC =SEC0tOARY CONT.

B = REQUEST FOR REQUAL OR BID ISSUED tiOTE: FCCR IH F = FLOOR 1100HTED QP =Q'JALIFIED BY

/ = LOCATED ON CONT.

C =S/H REC 0tStEt1DATI0ft TOLILCO

' TYPE I!TI:G* CCLtr.::4 IS i

HS = HOT STAPOBY PIPING AH*. LYSIS tlALL D = QUAL DOC RECEIVED QUAHTITY OF ITEIG.

I P3T=HULTI-FREQUENCY RH =RADHASTE T =llAIN STH. Tt# RIEL E =HARDilARE llCDIFICATIDH REQ'D

J l

BIAXIAL TESTIrlG SA = STATIC ANALYSIS H =HEITHER CS OR HS F = QUAL DOC APVD & FILED h

1 HST= Hut.TI-FREQUENCY SAT = sit:GLE FREQUENCY Z = PASSIVE ITEll G =SQRT PAPER C0t!PLETE 1

SINGLF AXIAL TESTING SINGLE AXIAL TESTING (SQRT PAPER HOT H = COPIES OF DOC TO DISTRIBUTION t

I REQ'D) y

s t

,i

[

4 s:

e

(M*'.).

I v

I SHOREHAM UNIT 1 GE LIST STONE & HEBSTER ENGINEERING CORPORATION RUN DATE 12/2b/E2 JOB NUtBER 11400 1-SORT GENERAL ELECTRIC CATEGORY I EQUIPHENT KUN TIllE 13.22.24

~

LILCO DOCHET 50-322 ACTIVE HSSS QUALIFICATION LEVELt151 ITEttS)

PAGE 7 H4RH EQUIPHENT GE BLDG AVAIL QUAL QUAL TYPE SAFETY Cutt i

lAJtBER DESCRIPTION HO.

VEtOOR ELEV INSP REPT HETH FREQ HTIG Ft2C STAlus

(

1H11mPtL-424 DIV 1 COR SP REL VB H11P624 GE CB044 YES SAI-0290A80PA-B teT 14 F

CS G

1H11mPtL-427 DIV 2 COR SP REL VB H11P627 GE CB044 YES SAI-0290A80PA-B fBT 14 F

CS-G 1H11mPit-628 AUTO BLoletti REL VB H11P428 GE CB044 YES SAI-0290A80PA-B HBT 14 F

CS G

f" 1H11mPit-631 AUTO DEPRESS H11P631 GE CB044 YES SAI-029QA80PA-B fBT 14 F

CS G

1H11mPit-435 DIV 1 RAD HONITOR H11P435 GE CB063 YES SAI-029QA80PA-B teT 21 F

H G

IH11mPit-434 DIV 2 RAD HONITOR H11P434 GE CB043 YES SAI-029QA80PA-B IET 21 F

ff G

1H11mPtL-654 HSIL LISPHCAGE H11P654 GE C8063 YES SAI-029QA80PA-B tmT 19 F

N G

1H11mPFL-455 HISL LISNCAGE HIIP455 GE C8043 YES SAI-029QA80PA-B teT 21 F

H G

~,

+

1H21mPtL-01 Ct4C SP9AY RH CH A H21P001 GE SC006 YES SAI-029QA80PA IBT 11 F

CS G

?

1H21mPit-02 RHCU SYSTEH INST H21P002 GE SC151 YES SAI-029QA80PA LOT 8

F, H

G

]

1H21mPtL-04 RX VES L & P RACH H21P004 GE SC079 YES SAI-029QA80PA HBT 8

F HS.CS G

j 1H21mPit-05 RX VES L & P RACH H21P005 GE SC079 YES SAI-029QA80PA IBT 8

F HS,CS G

1H21ePIL-04 RECIRC PutP A RAC H21P004 GE SC040 YES SAI-029QA80PA IET 11 F

N G

IH21mPFL-09 JET PutF A H21P009 GE SC079 YES SAI-029QA80PA IBT 11 F

H G

f 1H21mPtL-10 JET PLAP INST RH H21P010 GE SC079 YES SAI-029QA80PA teT 11 F

H G

1H21mPFL-14 HPCI INST RACH H21P014 GE SC008 YES SAI-029QA80PA IET 8

F N

G IH21

    • L-15 HAIN STH FLOH RH A H21P015 GE SC040 YES SAI-029QA80PA HBT 8

F H

G IH21*n L-16 CS/HPCI LH DET I H21P016 GE SC008 YES SAI-029QA80PA IST 11 F

N G

  • [

IH21mPtt-17 RCIC INST RACH H21P017 GE SC006 YES SAI-0290A80PA IST 8

F HS G

C3 sCONTROL BLOG P = PIPE H0ttfTED SBT= SINGLE FREQUEtCY QUALIFICATION HILESTONES REVISICtf 5 -DECEICER 1002

_CS = COLD SHUT DOtti PC =PRIHARY CONT.

BIAXIAL TESTING A =REEVALUATI0tl CutlPLETE DA :DYNAHIC AftALYSIS PL = PEDESTAL SC zSEC0tOARY CONT.

B mREQUEST FOR REGUAL OR BID ISSUED HOIE:

I:U"". LR Ill

.t 4

F = FLOOR HotRITED QP = QUALIFIED BY

/ mLOCATED ON CONT.

C sS/H REC 0f0lEFOATICH TOLILCO

  • TYPE IfirG* COLL'::'l IS 1

HS zHOT STAtOBY PIPING ANALYSIS HALL D zQUAL DOC RECEIVED GUA!ITITY OF ITEIS.

13T=HULTI-FREQUEHCY RH =RA0MASTE T =HAIN STH. TLAtlEL E zHAR0 HARE HODIFICATION REQ'D F

BIAXIAL TESTIffG SA zSTATIC ANALYSIS H-sNEITHER CS OR HS F = QUAL DOC APVD & FILED t.

1 HST=HULTI-FREQUENCY SAT = SINGLE FREQUEtCY Z PASSIVE ITEH G zSQRT PAPER CotPLETE s

J SINGLE AXIAL TESTING SINGLE AXIAL TESTING (SQRT PAPER NOT H aCCPIES OF DOC TO DISTRIBUTION

'~

l REQ'DI i

j i

F.'

l ss

y.

.g SHOREHAM LRtIT 1 GE LIST STONE & HEBSTER ENGINEERING CORPORATION RUN DATE 12/20/02

- ?*

JOS NUFBER 11400 1-50RT GENERAL ELECTRIC CATEGORY I EQUIPitENT RUN TIttE 13.22.M

k..

LILCO DOCHET 50-322 ACTIVE HSSS QUALIFICATION LEVELt151 ITEllS)

PAGE 8

  • }

HARN EQUIPHENT GE BLDG AVAIL QUAL QUAL TYPE SAFETY QUAL PARBER DESCRIPTION NO.

VEtBOR ELEV INSP REPT HETH FREQ HTr!G FU;iC STATUS

,' 'r 1H21mPit-18 RHR INST RACH CH H21P018 GE SC006 YES SAI-029QA80PA FBT 8

F HS'.CS G

,. ' =

1H21mPtt-19 CORE SPRAY RM CH H21P019 GE SC008 YES SAI-0290A80PA DET 11 F

CS G

J

[ ',

~

1H21mPit-21 RHR INST RACH CH H21P021 GE SC006 YES SAI-029QA00PA IST 8

F HS.CS G

1H21mPit-22 RECIRC PLRP B RAC H21P022 GE SC040 YES SAI-029QA80PA IST 8

F N

G 1H21mPit-25 HAIN STH FLON RN H21P025 GE SC040 YES SAI-029QA80PA t3T 11 F

N G

t 1H21mPFL-26 RV LV & PRES RN H21P026 GE SC079 YES SAI-029QA80PA RET 11 F,

HS.CS G

q.,.

1H21mPtL-30 SRH/IRH PREAFP RN H21P030 GE SC079 YES DRF A00-794-16 IET 4

F N

G 1H21mPit-31 SRH/IRH PREAtr RH H21P031 GE SC079 YES DRF A00-794-16 TOT 4

F N

G 1H21mPt0,-32 SRH/IRH PREAPP RN H21P032 GE SC079 YES DRF A00-794-14 PET 4

F N

G

~ ~ ~

1H21mPIL-33 CRH/IRH PREAtp RH H21P033 GE SC079 YES DRF A00-794-14

}BT 4

F N.

G v.

~*

IH21mPit-34 HPCI LEAN DET RH H21P034 GE SC008 YES SAI-0290A80PA HBT 2S F

H G

1H21mPtt-35 CS/RCIC LN DET I H21P035 GE SC040 YES SAI-0290A80PA lDT 11 F

N G

4 1H21mPtL-36 HPCI LEAN DET RH H21P034 GE SC008 YES SAI-0290A80PA HST 11 F

N C

1H21mPlL-37 RCIC LEAN DET RH H21P037 GE SC006 YES SAI-029QA80PA IST 25 F

N G

~~[

1H21aPit-38 RCIC LEAN DET RN H21P038 GE SC040 YES SAI-029QA80PA fBT 11 F

N

'G 1H21mPtt-41 tti STEAH FLOH IR H21P041 GE SC040 YES SAI-029QA80PA HBT 11 F

M G

1H21mPtt-73 HSIV LEAHAGE RH H21P073 GE SC063 YES SAI-029QA80PA IBT 11 F

N'

,G 1H21mPit-74 HSIV LEAHAGE RN H21P074 GE SC063 YES SAI-0290A80PA HBT 8

F N'

G

'.,4 a-i C3 = CONTROL BLDG P : PIPE HOUNTED SBT= SINGLE FREQUENCY QUALIFICATI0ft HILEST0tfES REVISI0tt S -DECEICER l'J02

_ CS = COLD SHUT DOHN PC =PRIllARY CONT.

BIAXIAL TESTING A = REEVALUATION CC!FLETE DA =DYNAHIC AttALYSIS PL : PEDESTAL SC =SEC0t!DARY C0ffT.

B = REQUEST FOR REQUAL OR BID ISSUED t:0TE: tiutGER Iti

.};

F = FLOOR HOUttTED QP = QUALIFIED BY

/ = LOCATED ON CarlT.

C =S/H REC 0titEtIDATI0tt TOLILCO

  • TYPE IITtGa COLL':::1 IS HS = HOT STANDBY PIPING At4ALYSIS

. HALL D = QUAL DOC RECEIVED QUAtiTITY'0F I1Ett3.

[

HBT=HULTI-FREQUENCY RH =RADHASTE T =HAIN STH. tut #4EL E =HARDHARE lt001FICATION REQ'D

/

DIAXIAL TESTING SA = STATIC ANALYSIS N =NEITHER CS OR HS F = QUAL DOC APVD & FILED

/

HST=HULTI-FREQUENCY SAT = SINGLE FREQUENCY Z = PASSIVE ITEH G =SQRT PAPER C0!!PLETE SINGLE AXIAL TESTING SINGLE AXIAL TESTING (SQRT PAPER NOT H = COPIES OF DOC TO DISTRIBUTION REQ'D)

~

\\

y 1

_h L,,

,.,/ -

m