JAFP-20-0012, License Amendment Request - Application to Adopt Technical Specification Task Force Traveler TSTF-568, Revision 2, Revise Applicability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2, Using the Consolidated Line.

From kanterella
(Redirected from ML20023A362)
Jump to navigation Jump to search

License Amendment Request - Application to Adopt Technical Specification Task Force Traveler TSTF-568, Revision 2, Revise Applicability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2, Using the Consolidated Line.
ML20023A362
Person / Time
Site: FitzPatrick 
(DPR-059)
Issue date: 01/23/2020
From: David Gudger
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
JAFP-20-0012
Download: ML20023A362 (24)


Text

Exelon Generation JAFP-20-0012 January 23, 2020 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 James A FitzPatrick Nuclear Power Plant Renewed Facility Operating License No. DPR-59 NRC Docket No. 50-333 200 Exelon Way Kennett Square. PA 19348 www.exeloncorp com 10 CFR 50.90

SUBJECT:

License Amendment Request -Application to Adopt Technical Specification Task Force Traveler TSTF-568, Revision 2, "Revise Applicability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2," Using the Consolidated Line Item Improvement Process Pursuant to 10 CFR 50.90, "Application for amendment of license, construction permit, or early site permit," Exelon Generation Company, LLC (Exelon) is requesting approval for proposed changes to the Technical Specifications (TS), Appendix A of Renewed Facility Operating License No. DPR-59 for the James A FitzPatrick Nuclear Power Plant.

Exelon requests adoption of TSTF-568, "Revise Applicability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2." TSTF-568 revises the Applicability and Actions of Technical Specification (TS) 3.6.2.5, "Drywall-to-Suppression Chamber Differential Pressure," and TS 3.6.3.2, "Primary Containment Oxygen Concentration," and presents the requirements in a manner more consistent with the Standard Technical Specifications (STS) format and content. provides a description and assessment of the proposed change. provides the existing TS pages marked to show the proposed change. provides the existing TS Bases pages marked to show revised text associated with the proposed TS changes and is provided for information only. provides revised (clean) TS and Bases pages.

Exelon requests review of this amendment request under the Consolidated Line Item Improvement Process (CLllP). Approval of the proposed amendment is requested by March 4, 2020. Exelon acknowledges that the requested approval date is shorter than was it is usually allowed for a CLllP.

License Amendment Request to Adopt TSTF-568, Revision 2 January 23, 2020 Page2 However, after the refueling outage in September 2018, station personnel recognized that drywell Continuous Atmospheric Monitoring (CAM) particulate counts were elevated and an adverse condition monitoring plan was established. Reactor Coolant System (RCS) operational unidentified leakage was initially stable at approximately 0 gpm. However, in December 2018, RCS operational unidentified leakage started to slowly trend up above 0 gpm to approximately 0.6 gpm in December 2019. On January 22, 2020, operational unidentified leakage was identified at 0.68 gpm. RCS operational identified leakage and drywell temperature are normal and stable.

Based on maintenance history and drywell sump samples, a failure mode analysis determined that the most likely cause is packing leakage from the Reactor Water Cleanup (RWCU) inboard MOV or reactor water recirculation MOVs. Pressure boundary leakage was determined to be unlikely.

Exelon is continuing to monitor and trend the leakage with established compensatory actions to ensure the safe operation of the James A. FitzPatrick Nuclear Power Plant (JAFNPP).

One of these actions is to enter the primary containment at one (1) gpm leakage, which ensure adequate time to implement corrective action plan. This leakage threshold is well below the TS limit of five (5) gpm.

In order to establish safe conditions for plant personnel in the primary containment without breathing apparatus to perform inspections and maintenance activities, the drywell atmosphere needs to be de-inerted. The process to de-inert the drywell, subsequent inert, and establish the drywell to suppression pool chamber differential pressure takes approximately 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br />. Additional time is required for plant personnel the access to the drywell, identify the source of the Reactor Coolant System (RCS) operational leakage, and repair the equipment. The Required Actions to restore the containment parameters for JAFNPP TS 3.6.2.4 Drywell-to-Suppression Chamber Differential Pressure LCO and 3.6.3.1 Primary Containment Oxygen Concentration would be exceeded requiring maneuvering the plant to less than 15 without a corresponding health and safety benefit.

Once approved, the amendment shall be implemented within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

Exelon has concluded that the proposed changes present no significant hazards consideration under the standards set forth in 10 CFR 50.92, "Issuance of amendments."

The proposed changes have been reviewed by the JAFNPP Plant Operations Review Committee in accordance with the requirements of the Exelon Quality Assurance Program.

In accordance with 10 CFR 50.91, "Notice for public comment; State consultation,"

paragraph (b), Exelon is notifying the State of New York of this application for license amendment by transmitting a copy of this letter and its attachments to the designated State Official.

If you have any questions or require additional information, please contact Enrique Villar at (610) 765-5736.

License Amendment Request to Adopt TSTF-568, Revision 2 January 23, 2020 Page 3 I declare under penalty of perjury that the foregoing is true and correct. Executed on the 231h day of January 2020.

Respectfully, David T. Gudger Senior Manager, Licensing Exelon Generation Company, LLC Attachments:

1. Evaluation of Proposed Changes
2. Markup of Proposed Technical Specifications Pages
3. Markup of Proposed Technical Specifications Bases Pages and Inserts (For Information Only) cc:
4. Revised (Clean) Technical Specifications and Bases Pages Regional Administrator - NRG Region I NRG Senior Resident Inspector - JAF NRG Project Manager, NRR - JAF A. L. Peterson, NYSERDA w/ attachments II II

ATTACHMENT 1 James A. FitzPatrick Nuclear Power Plant Renewed Facility Operating License No. DPR-59 NRC Docket No. 50-333 Evaluation of Proposed Changes License Amendment Request to Adopt TSTF 568 Revision 2 Page 1 of 5 Evaluation of Proposed Changes

Subject:

License Amendment Request - to adopt TSTF-568, Rev 2

1.0 DESCRIPTION

2.0 ASSESSMENT

2.1 Applicability of safety Evaluation 2.2 Optional Changes and Variations

3.0 REGULATORY ANALYSIS

3.1 No Significant Hazards Consideration 3.2 Conclusions

4.0 ENVIRONMENTAL CONSIDERATION

5.0 REFERENCES

License Amendment Request to Adopt TSTF 568 Revision 2 Page 2 of 5

1.0 DESCRIPTION

Exelon requests adoption of TSTF-568, "Revise the Applicability of BWR TS 3.6.2.5 and TS 3.6.3.2." TSTF-568 revises the Applicability and Actions of Technical Specification (TS) 3.6.2.5, "Drywell-to-Suppression Chamber Differential Pressure," and TS 3.6.3.2, "Primary Containment Oxygen Concentration," and presents the requirements in a manner more consistent with the Standard Technical Specifications (STS) format and content.

Exelon requests approval of this LAR by March 4, 2020.

2.0 ASSESSMENT

2.1 Applicability of Safety Evaluation Exelon Generation Company, LLC (EGC) has reviewed the Safety Evaluation for TSTF-568 provided to the Technical Specifications Task Force in a letter dated December 17, 2019. This review included a review of the NRC staff's evaluation, as well as the information provided in TSTF-568. Exelon has concluded that the justifications presented in TSTF-568 and the safety evaluation prepared by the NRC staff are applicable to the James A. FitzPatrick Nuclear Power Plant (JAF)

Station and justify this amendment for the incorporation of the changes to the JAF TS.

2.2 Optional Changes and Variations Exelon utilize different numbering than the Standard Technical Specifications on which TSTF-568 was based. Specifically, the numbering differences are as follow:

1. TSTF TS 3.6.2.5 "Drywell-to-Suppression Chamber Differential Pressure" corresponds to TS 3.6.2.4 for the JAFNPP plant
2. TSTF TS 3.6.3.2 "Primary Containment Oxygen Concentration" corresponds to TS 3.6.3.1 for the JAFNPP plant These variations are administrative and do not affect the applicability of TSTF-568 Rev 2 or the NRC's safety evaluation to the proposed license amendment.

License Amendment Request to Adopt TSTF 568 Revision 2 Page 3 of 5

3.0 REGULATORY ANALYSIS

3.1 No Significant Hazards Consideration Exelon requests adoption of TSTF-568, "Revise Applicability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2." TSTF-568 revises the Applicability and Actions of the James A.

FitzPatrick Nuclear Power Plant (JAFNPP) Technical Specification (TS) 3.6.2.4, "Drywell-to-Suppression Chamber Differential Pressure," and TS 3.6.3.1, "Primary Containment Oxygen Concentration," and presents the requirements in a manner more consistent with the Standard Technical Specifications (STS) format and content.

Exelon has evaluated if a significant hazards consideration is involved with the proposed amendment(s) by focusing on the three standards set forth in 10 CFR 50.92, "Issuance of amendment," as discussed below:

1. Does the proposed amendment involve a significant increase in the probability or consequences of an accident previously evaluated?

Response: No.

The proposed change revises the Applicability and Actions of TS 3.6.2.4, "Drywell-to-Suppression Chamber Differential Pressure," and TS 3.6.3.1, "Primary Containment Oxygen Concentration," and presents the requirements in a manner more consistent with the STS format and content. Drywell-to-suppression chamber differential pressure and primary containment oxygen concentration are not initiators to any accident previously evaluated. As a result, the probability of any accident previously evaluated is not affected by the proposed change.

Drywell-to-Suppression Chamber Differential Pressure and Primary Containment Oxygen Concentration are assumptions in the mitigation of some accidents previously evaluated. The Applicability of TS 3.6.3.1 is changed from Mode 1 when thermal power is greater than 15% to Modes 1 and 2. This expands the Applicability of the TS and will not have an effect on the consequences of an accident. The existing Applicability exceptions are removed and replaced with a longer Completion Time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The consequences of an event that could affect the drywell-to-suppression chamber differential pressure and primary containment oxygen concentration are no different during the proposed Completion Time than the consequences of the same event during the existing Completion Times. A note referencing Limiting Condition for Operation (LCO) 3.0.4.c is added to the Actions to permit entering the Applicability with the LCO not met. The note replaces the existing Applicability exceptions. This change is administrative and has no effect on the consequences of an accident.

License Amendment Request to Adopt TSTF 568 Revision 2 Page 4 of 5 Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.

2. Does the proposed amendment create the possibility of a new or different kind of accident from any accident previously evaluated?

Response: No.

The proposed change revises the Applicability and Actions of TS 3.6.2.4, "Drywell-to-Suppression Chamber Differential Pressure," and TS 3.6.3.1, "Primary Containment Oxygen Concentration," and presents the requirements in a manner more consistent with the STS format and content.

The proposed change does not involve a physical alteration of the plant (no new or different type of equipment will be installed). No credible new failure mechanisms, malfunctions, or accident initiators that would have been considered a design basis accident in the UFSAR are created because the Nuclear Regulatory Commission has determined that hydrogen generation is not risk significant for design basis accidents.

Therefore, the proposed change does not create the possibility of a new or different kind of accident from any accident previously evaluated.

3. Does the proposed amendment involve a significant reduction in a margin of safety?

Response: No.

The proposed change revises the Applicability and Actions of TS 3.6.2.4, "Drywell-to-Suppression Chamber Differential Pressure," and TS 3.6.3.1, "Primary Containment Oxygen Concentration," and presents the requirements in a manner more consistent with the STS format and content. No safety limits are affected. No Limiting Conditions for Operation or Surveillance limits are affected. The Drywell-to-Suppression Chamber Differential Pressure and Primary Containment Oxygen Concentration Technical Specification requirements assure sufficient safety margins are maintained, and that the design, operation, surveillance methods, and acceptance criteria specified in applicable codes and standards (or alternatives approved for use by the NRC) will continue to be met as described in the plants' licensing basis. The proposed change does not adversely affect existing plant safety margins or the reliability of the equipment assumed to operate in the safety analysis. As such, there are no changes being made to safety analysis assumptions, safety limits, or limiting safety system settings that would adversely affect plant safety.

License Amendment Request to Adopt TSTF 568 Revision 2 Page 5 of 5 Therefore, the proposed change does not involve a significant reduction in a margin of safety.

Based upon the above, Exelon concludes that the proposed amendment presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.

3.2 Conclusions In conclusion, based on the considerations discussed above, (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.

4.0 ENVIRONMENTAL CONSIDERATION

The proposed change does not change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or does not change an inspection or surveillance requirement. The proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluents that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure.

Accordingly, the proposed change meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9).

Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed change.

5.0 REFERENCES

1. Technical Specification Task Force Traveler TSTF 568, Revision 2, "Revise Applicability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2," Using the Consolidated Line Item Improvement Process (EPDI L-2017-PMP-0024).
2. Final Safety Evaluations of Technical SpecifiGation Task Force Traveler TSTF 568, Revision 2, "Revise Applicability of BWR/4 TS 3.6.2.5 and TS 3.6.3.2," Using the Consolidated Line Item Improvement Process (EPDI L-2017-PMP-0024), dated December 17, 2019. \\

ATTACHMENT 2 Markup of Proposed Technical Specifications Pages TS LCO Pages 3.6.2.4-1 3.6.3.1-1

Drywall-to-Suppression Chamber Differential Pressure 3.6.2.4 3.6 CONTAINMENT SYSTEMS 3.6.2.4 Drywall-to-Suppression Chamber Differential Pressure LCO 3.6.2.4 The drywell pressure shall be maintained~ 1.7 psi above the pressure of the suppression chamber.

NOTE Not required to be met for 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during Surveillances that cause or require the dF)well to suppression chamber differential pressure to be outside the limit.

APPLICABILITY:

MODE 1 during the time period:with THERMAL POWER > 15% RTP.

a.

From 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after THERMAL PQ\\NER is > 15% RTP following startup, to

b.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to reducing THERMAL POWER to < 15% FHP prior to the next scheduled reactor shutdown.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

Drywell-to-suppression A.1


NOTE----------

8-72 hours chamber differential LCO 3.0.4.!;! is Agglicable.

pressure not within limit.

Restore differential pressure to within limit.

B.

Required Action and B.1 Reduce THERMAL 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion POWER to ~ 15% RTP.

Time not met.

JAFNPP 3.6.2.4-1 Amendment

Primary Containment Oxygen Concentration 3.6.3.1 3.6 CONTAINMENT SYSTEMS 3.6.3.1 Primary Containment Oxygen Concentration LCO 3.6.3.1 The primary containment oxygen concentration shall be < 4.0 volume percent.

APPLICABILITY:

MODE 1 g_dufing-the-time--pefietimd 2.

a.

From 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after THERMAL POWER is > 15% RTP following startup, to

b.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to reducing THERMAL POWER to < 16% RTP prior to the next scheduled reactor shutdown.

ACTIONS CONDITION REQUIRED ACTION A.

Primary containment A.1


NOTE----------

oxygen concentration LCO 3.0.4.c is AQQlicable.

not within limit.

Restore oxygen concentration to within limit.

B.

Required Action and B.1 Redttee-ll=IERMAl::-PGWE:R-associated Completion to < 15% RTP.B~ in MODE Time not met.

3_.

SURVEILLANCE REQUIREMENTS SURVEILLANCE SR 3.6.3.1.1 JAFNPP Verify primary containment oxygen concentration is within limit.

3.6.3.1-1 COMPLETION TIME 24-72 hours 8-12 hours FREQUENCY In accordance with the Surveillance Frequency Control Amendment

SURVEILLANCE JAFNPP Primary Containment Oxygen Concentration 3.6.3.1 I FREQUENCY Program 3.6.3.1-1 Amendment

ATTACHMENT 3 Markup of Proposed Technical Specifications Bases Pages and Inserts (For Information Only)

TS Bases Pages B 3.6.2.4-2 B 3.6.2.4-3 B 3.6.3.1-2

BASES LCO

{continued)

APPLICABILITY ACTIONS JAFNPP Drywell-to-Suppression Chamber Differential Pressure B 3.6.2.4 LCO 3.6.2.2. Failure to maintain the required differential pressure could result in excessive forces on the suppression chamber due to higher water clearing loads from downcomer pipes and higher pressure buildup in the drywell.The LCO is modified by a Note whieh states that the LCO is not required to be met up to four hours during Surveillances that eause or require drywell to suppression ehamber differential pressure to be outside of limits. Ti=lese Surveillances include required OPERABILITY testing of the Higi=I Pressure Coolant lnjeetion System, the Reaetor Core Isolation Cooling System, and ti=le suppression ci=lamber todryiuell vaeuum breal<ers. Ti=le '1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> allowanee is adequate to perform the Surveillances and to restore the dryi.'lell to suppression ehamber differential pressure to within limits.

Drywell-to-suppression chamber differential pressure must be controlled when the primary containment is inert. The primary containment must be inert in MODE 1 with THERMAL POWER >15%

RTP. since this is the condition with the highest probability for an event that could impose large loads on the primary containment.DryNell to suppression ehamber differential pressure must be eontrolled when the primary containment is inert. The primary eontainment must be inert in MODE 1, sinee this is the condition with the t:iighest probability for an event that could produee hydrogen. It is also the eondition with the highest probability of an event that eould impose large loads on the primary eontainment.

lnerting primary oontainment is an operational problem beeause it prevents primary containment aooess without an appropriate breathing apparatus. Therefore, the primary oontainment is inerted as late as possible in the plant startup and is de inerted as soon as possible in the plant shutdown. As long as reaetor power is < 16%

RTP, the probability of an e*;ent that generates hydrogen or excessive loads on primary eontainment oecurring within the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> follovt'ing a startup or within the last 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to a shutdown is lovt' enough that these 11windo*Ns, 11 with the primary containment not tnerted, are also justified. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> time period is a reasonable amount time to allo1N plant personnel to perform inerting or de inerting.

A.1 If drywell-to-suppression chamber differential pressure is not within the limit, the conditions assumed in the safety analyses are not met B 3.6.2.4-2 Revision

Drywell-to-Suppression Chamber Differential Pressure 83.6.2.4 BASES (continued)

SURVEILLANCE REQUIREMENTS REFERENCES JAFNPP and the differential pressure must be restored to within the limit within 8-72 hours. The 8-72 hour Completion Time pro*1ides sufficient time to restore differential pressure to \\ttithin limit and takes into account the low probability of an event that would create excessive suppression chamber loads occurring during this time period.

A Note permits the use of the provisions of LCO 3.0.4.c. This allowance permits entry into the applicable MODE(s) while relying on the ACTIONS. This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus. Therefore. the primary containment is jnerted as late as possible in the plant startup. after entering MODE 1 with THERMAL POWER > 15% RTP. and de-inerted as soon as possible in the plant shutdown. It is acceptable to intentionally enter the Required Action A.1 prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

B.1 If the differential pressure cannot be restored to within limits within the associated Completion Time, the plant must be placed in a MODE in which the LCO does not apply. This is done by reducing power to s 15% RTP within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

SR 3.6.2.4.1 The drywall-to-suppression chamber differential pressure is regularly monitored to ensure that the required limits are satisfied. Tbl!ntralhmJ Frequency of this SR was developed based on operating experience relative to differential pressure variations during applicable MODES.

Furthermore, the 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Frequency is considered adequate in view of other indications available in the control room, including alarms, to alert the operator to an abnormal pressure condition.

1.
2.

UFSAR, Section 5.2.3.3.

10 CFR 50.36(c)(2)(ii).

B 3.6.2.4-3 Revision

BASES (continued)

APPLICABILITY ACTIONS JAFNPP Primary Containment Oxygen Concentration B3.6.3.1 The primary containment oxygen concentration must be within the specified limit when primary containment is inerted.., except as allowed by the relaxations during startup and shutdown addressed belO't\\'. The primary containment must be inert in MODE 1 and 2, since this is the condition with the highest probability of an event that could produce hydrogen.lnerting the primary oontainment is an operational problem beoause it prevents oontainment aoeess without an appropriate breathing apparatus. Therefore, the primary oontainment is inerted as late as possible in the plant startup and de inerted as soon as possible in the plant shutdown. As long as reaetor power is <

15% RTP, the potential for an e*;ent that generates significant hydrogen is low and the primary oontainment need not be inert.

Furthermore, the probability of an event that generates hydrogen ooourring 'Nithin the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of a startup, or 1Nithin the last 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> before a shutdown, is low enough that these 111Nindows," when the primary oontainment is not inerted, are also justified. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> time period is a reasonable amount of time to allow plant personnel to perform inerting or de inerting.

A.1 If oxygen concentration is~ 4.0 v/o at any time while operating in MODE 1 or 2, with the exeeption of the relaxations allo*Ned during startup and shutdown, oxygen concentration must be restored to<

4.0 v/o within ~72 hours. The ~72 hour Completion Time is allowed when oxygen concentration is~ 4.0 v/o because of the--

availability of other hydrogen mitigating systems (e.g., the GAD System) and the low probability and long duration of an event that would generate significant amounts of hydrogen occurring during this period.

A Note permits the use of the provisions of LCO 3.0.4.c. This allowance permits entry into the applicable MODE(S) while relying on the ACTIONS. This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus. Therefore. the primary containment is inerted as late as possible in the plant startup. after entering MODE 1 with THERMAL POWER > 15% RTP. and de-inerted as soon as possible in the plant shutdown. It is acceptable to intentionally enter the Required Action A.1 prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

B 3.6.3.1-2 Revision

INSERT1 Drywell-to-suppression chamber differential pressure must be controlled when the primary containment is inert. The primary containment must be inert in MODE 1 with THERMAL POWER >15% RTP, since this is the condition with the highest probability for an event that could impose large loads on the primary containment.

INSERT2 A Note permits the use of the provisions of LCO 3.0.4.c. This allowance permits entry into the applicable MODE(S) while relying on the ACTIONS. This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus. Therefore, the primary containment is inerted as late as possible in the plant startup, after entering MODE 1 with THERMAL POWER > 15% RTP, and de-inerted as soon as possible in the plant shutdown. It is acceptable to intentionally enter the required Action A.1 prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

ATTACHMENT 4 Revised (Clean) Technical Specifications and Bases Pages TS LCO Pages 3.6.2.4-1 3.6.3.1-1 TS Bases Pages B 3.6.2.4-2 B 3.6.2.4-3 B 3.6.3.1-2

3.6 CONTAINMENT SYSTEMS Drywell-to-Suppression Chamber Differential Pressure 3.6.2.4 3.6.2.4 Drywell-to-Suppression Chamber Differential Pressure LCO 3.6.2.4 The drywell pressure shall be maintained~ 1.7 psi above the pressure of the suppression chamber.

APPLICABILITY:

MODE 1 with THERMAL POWER> 15% RTP.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

Drywell-to-suppression A.1


NOTE----------

72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> chamber differential LCO 3.0.4.c is Applicable.

pressure not within limit.

Restore differential pressure to within limit.

B.

Required Action and B.1 Reduce THERMAL 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion POWER to ~ 15% RTP.

Time not met.

JAFNPP 3.6.2.4-1 Amendment

Primary Containment Oxygen Concentration 3.6.3.1 3.6 CONTAINMENT SYSTEMS 3.6.3.1 Primary Containment Oxygen Concentration LCO 3.6.3.1 The primary containment oxygen concentration shall be< 4.0 volume percent.

APPLICABILITY:

MODE 1and 2.

ACTIONS CONDITION REQUIRED ACTION A.

Primary containment A.1


NOTE----------

oxygen concentration LCO 3.0.4.c is Applicable.

not within limit.

Restore oxygen concentration to within limit.

B.

Required Action and B.1 Be in MODE3.

associated Completion Time not met.

SURVEILLANCE REQUIREMENTS SURVEILLANCE SR 3.6.3.1.1 JAFNPP Verify primary containment oxygen concentration is within limit.

3.6.3.1-1 COMPLETION TIME 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 12 hours FREQUENCY In accordance with the Surveillance Frequency Control Program Amendment

BASES LCO (continued)

APPLICABILITY ACTIONS JAFNPP Drywall-to-Suppression Chamber Differential Pressure B3.6.2.4 LCO 3.6.2.2. Failure to maintain the required differential pressure could result in excessive forces on the suppression chamber due to higher water clearing loads from downcomer pipes and higher pressure buildup in the drywell.

Drywell-to-suppression chamber differential pressure must be controlled when the primary containment is inert. The primary containment must be inert in MODE 1 with THERMAL POWER >15%

RTP, since this is the condition with the highest probability for an event that could impose large loads on the primary containment.

A.1 If drywall-to-suppression chamber differential pressure is not within the limit, the conditions assumed in the safety analyses are not met and the differential pressure must be restored to within the limit within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Completion Time takes into account the low probability of an event that would create excessive suppression chamber loads occurring during this time period.

A Note permits the use of the provisions of LCO 3.0.4.c. This allowance permits entry into the applicable MODE(s) while relying on the ACTIONS. This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus. Therefore, the primary containment is inerted as late as possible in the plant startup, after entering MODE 1 with THERMAL POWER > 15% RTP, and de-inerted as soon as possible in the plant shutdown. It is acceptable to intentionally enter the Required Action A.1 prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

B.1 If the differential pressure cannot be restored to within limits within the associated Completion Time, the plant must be placed in a MODE in which the LCO does not apply. This is done by reducing power to

~ 15% RTP within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

(continued)

B 3.6.2.4-2 Revision

Drywall-to-Suppression Chamber Differential Pressure B 3.6.2.4 BASES (continued)

SURVEILLANCE REQUIREMENTS REFERENCES JAFNPP SR 3.6.2.4.1 The drywall-to-suppression chamber differential pressure is regularly monitored to ensure that the required limits are satisfied. The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Frequency of this SR was developed based on operating experience relative to differential pressure variations during applicable MODES.

Furthermore, the 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Frequency is considered adequate in view of other indications available in the control room, including alarms, to alert the operator to an abnormal pressure condition.

1.
2.

UFSAR, Section 5.2.3.3.

10 CFR 50.36(c)(2)(ii).

B 3.6.2.4-3 Revision

BASES (continued)

APPLICABILITY ACTIONS SURVEILLANCE REQUIREMENTS JAFNPP Primary Containment Oxygen Concentration B3.6.3.1 The primary containment oxygen concentration must be within the specified limit when primary containment is inerted. The primary containment must be inert in MODE 1 and 2, since this is the condition with the highest probability of an event that could produce hydrogen.

A.1 If oxygen concentration is~ 4.0 v/o while operating in MODE 1 or 2, oxygen concentration must be restored to < 4.0 v/o within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

The 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Completion Time is allowed when oxygen concentration is~ 4.0 v/o because of the low probability and long duration of an event that would generate significant amounts of hydrogen occurring during this period.

A Note permits the use of the provisions of LCO 3.0.4.c. This allowance permits entry into the applicable MODE(S) while relying on the ACTIONS. This allowance is acceptable because inerting the primary containment prevents containment access without an appropriate breathing apparatus. Therefore, the primary containment is inerted as late as possible in the plant startup, after entering MODE 1 with THERMAL POWER > 15% RTP, and de-inerted as soon as possible in the plant shutdown. It is acceptable to intentionally enter the Required Action A.1 prior to a shutdown in order to begin de-inerting the primary containment prior to exiting the Applicability.

B.1 If oxygen concentration cannot be restored to within limits within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, power must be reduced to s 15% RTP within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. The 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> Completion Time is reasonable, based on operating experience, to reduce reactor power from full power conditions in an orderly manner and without challenging plant systems.

SR 3.6.3.1.1 The primary containment must be determined to be inert by verifying that oxygen concentration is < 4.0 v/o. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.

(continued) 83.6.3.1-2 Revision