Amend 33 to License NPF-62,adding Note to Item 14 on Tech Spec Table 3.3.7.5-1 to Allow Inoperability of Primary Containment Isolation Valve Position When Valve Electrically Deactivated in Isolated Position
ML20012F605
Person / Time
Site: Clinton 
(NPF-62-A-033, NPF-62-A-33)
Issue date: 03/29/1990
From: Jocelyn Craig
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20012F606 List:
References
NUDOCS 9004160276
Download: ML20012F605 (4)


Text

-

h

+#p2 *f og'o UNITED STATES 5

8",

/g -

NUCLEAR REGULATORY COMMISSION i

c i

.mj

{

wAsHwovoN,0,c resu

  • %,...+/

ILLIN0IS POWER COMPANY. ET AL.

DOCKET NO. 50-461 CL1HTON POWER STATION UNIT NO. 1 i

AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.33 License No. NPF-62 1.

The Nuclear Requiatory Comission (the Comission) has found that:

The application for amendment by(the licensees) dated February 5,lilinoi A.

Soyland Power Cooperative, Inc.

1988, complies with the standards and re Energy Act of 1954, as amended (the Act)quirements of the Atomic

, and the Comission's rules and requistions set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance-(1) that the activities authorized by this amendment can be conducted without endancering the health and safety of the puolic, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the pubitc; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operatina License No. NPF-62 is hereby amended to read as follows:

i

'I111 nots Power company is authorized to act as agent for Soylano Power Cooperative, Inc. and has exclusive responsibility and control over the physical construction, operation and traintenance of the facility.

9004160276 900329 gDR ADOCK0500g1

e lc Technical Specifications The Technical Specificati ans contained in Appendix A and the

{

Environmental Protection Plan contained in Appendix B, as revised through Amendment No,33. are hereby incorporated into this license.

Illinois Power Company shall operate the facility in l

accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date c' iguanca.

FORyHE NUCl. EAR sE6OMOM COMMISSION

_.O MohnK.Craig, Director Project Directorate 111-2 Division of Reactor PrAiects - 111, IV, V and Special Projects

Attachment:

Changes to the Technical Specifications Date'of Issuance: 11 arch 29,1990 i

f a

1

j

.I i

ATTAttiMENT TO LICENSE AMENDMENT NO. 33 FACIllTY OPERATING LICENSE NO. NPF-62 DOCKET NO. 50-461 t

i Replace the following page of the Appendix "A Technical Spnifications with the attached page. The revised page is identified by amendment number and contains vertice1 lines indicating the crea of chango.

Remove Insert 3/4 3-87 3/4 3-87 p

5 l

1 l

e

- C. '

c3 TABLE 3.3.7.5-1

/

C

'i ACCIDENT MONITORING INSTRUMENTATION E

MINIMUM APPLICABLE REQUIRED NUMBER CHANNELS OPERATIONAL c

I'5 INSTRUMENT OF CHANNELS OPERABLE CONDITIONS ACTION

.a 1.

Reactor Vesset Pressure 2

1 1,2,3 80 2.

Reactor Vessel Water Level 2

1 1,2,3 80 3.

Suppression Pool Water Level 4

2 1,2,3 80 4.

Suppression Pool Water Temperature 2/quadrantt 1/quadrantt 1, 2, 3 80 5.

Drywell Pressure 2

1 1,2,3 80 6.

Drywell Air Temperature 2

1 1,2,3 80 7.

Drywell/ Containment Hydrogen and Oxygen Concentration Analyzer and Monitor 2

1 1,2,3 83 8.

Containment Pressure ##

2/ division 1/ division 1, 2, 3 80 w

9.

Containment Temperature 2

1 1,2,3 80 1 10. Safety / Relief Valve Acoustic Monitor 1/ valve ***

1/ valve ***

1,2,3 80

11. Containment /Drywell High Range Gross Gamma w5 Radiation Monitors 4**

2*

1,2,3 81

12. HVAC Stack High Range Radioactivity Monitor #

1 1

1,2,3 81

13. SGTS Exhaust High Range Radioactivity Monitor #

1 1

1,2,3 81

14. Primary Containment Isolation Valve Position Indication it 2/ valve ###

1/ valve ###

1,2,3 82 l

TABLE NOTATIONS

  • One each for containment and drywell.
    • Two each for containment and drywell.
      • Thermocouples in the SRV discharge line can serve as backup to the acoustic tail pipe monitors indication y

should one channel of the position indication become inoperable.

  1. High range noble gas monitors and iodine / particulate sampler.
    1. For Divisions I and II only.
      1. Not applicable if valve position indication is unavailable because the valve was deliberately deactivated, provided the valve is in the isolated position and administrative controls are in place to ensure that the control room operators can determine the valve's position, if needed. Valves closed in accordance with these conditions may be reopened on an intermittent basis under administrative controls.

t These instruments monitor suppression pool water temperature when pool water level is below instruments of Specification 3.6.3.1.

tt One channel consists of the open limit switch, and the other channel consists of the closed limit switch for each autonatic isolation valve in Table 3.6.4-1 Part 1, " Automatic Isolation Valves."

+

~.