<.g:
g l 6' 1990-i y
~'.
In Reply Refer To:
- Docket
- -150-298 Nebraska Public Power District ATTN: George A.-Trevors:
c Division Manager - Nuclear Support P.O. Box 499-
. Columbus, Nebraska ' 68602-0499
.. Gentlemen:
4 This is to acknowledge the receipt of your letter dated September 19, 1989,'
i submitting revisions to your Emergency Plans.
'According to-10 CFR 50.54(q), changes to your Emergency Plans may be made-without Commission approval only if the changes do not decrease the-effectiveness of the plans, and the plans as changed, continue to meet the standards of.550.47(b) and 10 CFR 50, Appendix E.
According to your letter,
~
your changes: satisfy this criteria. We understand that these changes have
?
~
-been-implemented in the emergency preparedness program at Cooper Nuclear Station. However, should we reach a conclusion that these changes do, in fact, decrease the effectiveness of your emergency plans, you will be required to implement-the: plan that was in. place prior to the proposed revisions.
We are'in the process of review of-your changes which involve revisions to your Emergency Action; Level (EAL) Initiating Events. We have identified in the l
' attachment to this letter nine instances whereby your. revised initiating-events-
-appear to have either:
- 1) altered ~in a nonconservative direction your previous:
L
. initiating events, or 2) deleted some initiating event specified in the prior p
revision and NUREG-0654. Without further information, it is not-evident why l.
these-changes do not decrease the effectiveness of'the Emergency Plan.
L In order for u's to continue our review of your changes, we need you.to provide R
~ specific information explaining-why each of the attached revisions or deletions
'did not decrease the effectiveness of your plans in arriving-at the proper EAL~
classification following the onset of the corresponding' initiating event.
I Our need for the additional information was discussed by telephone on L
March 7,1990, between yourself'and Dr. D. Blair Spitzberg of this office.
During this discussion, you committed to provide this information within
.30 days'of the receipt of this letter.
I 89-254
- RIV:SEPS
- C:SEPS D:DRSS D
BSpitzberg/ sir DPowers BBeach -
S 111n
/ /90
/ /90 3 /p/90
% / /90
- Previously Concurred 9003270303 900316 PDR ADOCK 05000298 f
F PDC
+
p
E I
4 6.- O
. Nebraska Public Power District; -
4 Should.you have any questions concerning this matter, please contact.
-Dr. D. Blair Spitzberg at (817) 860-8191.
Original Signed By Samuel J. Collins, Director Division of Reactor Projects
Attachment:
-As stated-f cc w/ attachment:
'l Nebraska Public' Power District
'=
ATTN:
G. D. Watson, General Counsel P.O. Box 499'
. Columbus, Nebraska 68601 Cooper Nuclear Station-
-ATTN:. Guy R.' Horn,' Division
.l Manager of Nuclear Operations-
-P.O. Box 98'-
Brownv111e,. Nebraska 68321-
- Nebraska Department of Environmental
-Control ATTN: Dennis Grams, Director P.O.-Box 98922 1
Lincoln,. Nebraska 68509-8922-1 Nemaha County Board of Commissioners
]
. ATTN:: Larry. Bohlken, Chairman l
Nemaha County Courthouse 1824 N Street
- Auburn,. Nebraska' 68305 Department of Health Division.of Radiological Health ATTN:. Harold Borchart, Director j
301 Centennial Mall, South' P.O. Box 95007 i
Lincoln, Nebraska 68509-5007
~ Kansas Radiation-Control Program Director U.S. Nuclear Regulatory Commission ATTN:
Senior Resident Inspector P.O. Box 218 Brownville, Nebraska 68321
)
L it
P " ~ o, f. o..
/>- ' '
l
~ Nebraska-Public Power' District '
,'m i
U.S.iNuclear Regulatory Commission-I R
ATTN: Regional Administrator, Region IV
'6111Ryan-Plaza Drive,' Suite 1000
- Arlington, Texas 76011 ya,
Program Manager FEMA Region 7.
911 Walnut Street,: Room'200' Kansas City, Missouri 64106 Director-
. Nebraska Civil Defense. Agency -
1300 Military Road:
i' Lincoln, Nebraska 68508 (A045)
R. Martin Resident Inspector-Lisa Shea,; RM/ALF.
s RPB-DRSS Section Chief,-DRP/C MIS System
-RIV File DRP
.RITS Operator s
DRS.
l "s
B. Beach.
D. Powers N.'Terc lG. Bates
. Project Engineer, DRP/C P.:0' Conner, NRR Project Manager-
.W.:D.= Travers, NRR s
,f; t
4 f'
e
i I
- , * ?
Attachment Corresponding NUREG-0654 EAL, Initiating Event in Example Initiating Initiating Event, E-Plan
-Previous E-Plan Revision Condition Revision 11, 8/31/89
- 1. -NOVE, (No. 2) Radio-(No. 2) Radiological 1.1.2 RETS limits exceeded logical, effluent-effluent technical as indicated by a HIGH technical specification
. specification limits alarm on a aaneous effluent (RETS) limits exceeded.-
exceeded.
monitor.
~
2.
NOVE, (8b,d), River Level (No. 13b) 50 year flood 7.1.2 River level areater greater than 897 ft. or or low water, than 899 f t. or less than.
less than 870 ft.
867 ft.
3.
ALERT.(No. 8) Complete (No. 10) Complete loss 3.2.3-Complete loss of all loss of capabilities of any function needed available means to place needed for plant cold for plant cold shutdown, the plant in a cold shut-
- shutdown, down condition when cold a
shutdown is required.
4.
ALERT (No. 11) Serious (No. 13) Fire 5.2.1 A fire with potential
' fire endangering plant potentially effecting to cause degradation of safety-systems, safety systems, multiple plant safety i
systems.
5.-
ALERT (No. 15d) Low (No.-17) Low water 7.2.2 River level less water below 867 ft.
near design levels.
_than 865 ft.
-level.
- 6.,SAE (No. 6) Complete (No. 8) Complete loss 3.3.3 Complete-loss of all loss-of capabilities of any function needed available means to place or q
needed for plant hot for plant hot shutdown.
monitor the plant in a hot shutdown.
shutdown condition when required.
7.
SAE (No. 9) Fire (No. 11) Fire 5.3.1 Fire which renders compromising the compromising the multiple ECCS systems
- functions of safety functions of safety inoperable when they are systems.
systems.
required to be operable.
8.
SAE (No. 14) Entry of (No. 16) Entry of 5.3.2 Uncontrolled entry uncontrolled' flammable uncontrolled flammable of toxic or flammable gas.into' vital areas; gases into vital areas, material into vital areas entry of uncontrolled Entry of uncontrolled where lack of access toxic gases into vital toxic gases into vital constitutes a safety areas.where lack of areas where lack of problem.
access to the area access to the area constitutes a safety constitutes a safety problem.
-problem.
9.
SAE (No. 4) Steam line (No. 4) Steam line break Not specified.
break outside contain-outside of containment ment without' isolation.
without isolation.
- -