Monthly Operating Repts for Feb 1990 for Limerick Generating Station Units 1 & 2
ML20012C110
Person / Time
Site: Limerick  
Issue date: 02/28/1990
From: Leitch G, Jerome Murphy
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9003200115
Download: ML20012C110 (16)


Text

r T.S.6.9.1.6 PHILADELPHIA ELECTRIC COMPANY 3901020600 LIMERICK GENER ATING ST ATION P. O. DOX A S AN ATOG A. PENNSYLV ANI A 19464 (218) 3371200. EXT. 3000 0.0. ;i.,

  • March 9, 1990 Docket Nos. 50-352 50-353 License Nos. NPF-39 NPF-85 c.

l I

U.+sa NuclearrRegulatory Commission Attn:

Document Control Desk Washington, DC 20555

Subject:

Limerick Generating Station Monthly Operating Report For Units 1 and 2 l'

Enclosed are the monthly operating reports for Limerick Units i

1 and 2 for the month of February, 1990 forwarded pursuant to Technical Spacification 6.9.1.6.

I l

Very truly

ours, W

KWM/kk Enclosure cc:

William T. Russell, Administrator, Region I, USNRC T. J. Kenny, USNRC Senior Resident Inspector

/

\\

g&. 3200115 90022eADUCN 05000352 b5

\\

13

\\

4 PDC P1 w

3901020600 i

Docket No. 50-352 Attachment to Monthly Operating Report for February 1990 Limerick Generating Station Unit 1 February 1 through February 28, 1990 I.

Narrative Summary of Operatina Erneriences Limerick Unit 1 began the month of February at a nominal 100%

of rated thermal power.

On February 6,

reactor power was reduced to 90% to accommodate Main Turbine Control Valve testing.

On February 16, reactor power was reduced briefly to 75% to support a control rod pattern adjustment.

On i

February 18, reactor power was reduced to 73% to support isolation of the

'6B' feedwater heater for corrective I

maintenance on the bleeder trip valve.

On February 22, reactor power was reduced briefly to 90% due to high turbine backpressure.

On February 23, reactor power was reduced briefly to 90% to return the '6B' feedwater heater to service and to support a control rod pattern adjustment.

Limerick Unit 1 ended the month of February at a nominal 100% of rated i

thermal power.

Operational events that occurred during the month of February included:

On February 28, HV-050-1F005, RCIC Vacuum Tank Condensate Drain to Radwaste, was found closed with the handswitch I

in the open position.

Investigation revealed that the normally energized solenoid was deenergized.

The solenoid was found to have burned out.

HV-050-1F005 was then blocked open under Supervisory Permit.

On' March 1, HV-049-1F025, Drain Pot Inboard valve failed closed. A burned out solenoid on the valve actuator was found and t

RCIC was declared inoperable.

An air jumper was installed per TCA to maintain HV-049-1F025 open.

On March 2,

HV-409-1F026, RCIC Drain Pot Outboard valve, failed closed.

A burned out solenoid was again the cause.

It was determined that the solenoids had failed due to

'AC' solenoids being installed on the valves l

instead of the 'DC' solenoids.

These solenoids had been L

replaced to meet EQ program maintenance during the Unit 1 RCIC outage on February 19 through 22.

The solenoids have subsequently been replaced.

l II.

Challences to Main Steam Safety Relief Valy_gg i

1 There were no challenges to the Main Steam Relief Valves I

during the month of February.

l l

e s e.

O O

Y O

N O

o-e O

.%n

.J 1 >

1.

Nt ma 1

2 I Ot wi 7

5 i W

. A O M

.A i

w I

h I

l E

U1 e

OI W

i e

w e.

3 O

M Mt O^

M Z l

&F e-m M

h e

E O

W1 W

D 4D N

E E

& 1

>3 e

N M

O &

M M

M M

M X

.J t C O O O Di O O O O O.-

H u

OEw em

. W AO>

W' w us e

e e

e e

e F

.J -

Mwd 4) 3-W

>ME Oi Oa O

EMW D1.

W w

4 W>Z N'

I @ '

m I 6nW e-O I @

e-T 3OO 4

4 6

EM b

a N

W

.J 3 MW N

W to ui ID W

SOMU M J

M M.

O' HUM I

e W

F I ' 4

  • &WE
  • t e

u8 U

.J l 707W mi

&O&

W 3

a w

i

  • I

.J O

M i e

I

  • WgM N4 b

O e+

N M

9 b

ILi w 6 e

e e

e N

N N

N N

N-N N

N th J ii &

7 E CL.J N

O W

W D

m e

Z 2

W e

3 O H

H W

W M

E U

.J

.J E

W W

'P W

W

.J

.J m

N 4

W D

ROm kl

&F 0

ma M

e-M m m N

b e

O O

N O

4 Oi

>Z M

M M

N M

N N

M N

M M

M M

M (D

E

@ I,

.h 8 O O O O O O O O O O O O O O O us on wW e

e e

e e

e-e e

e-e e

e e

e D)

(

e a

4 w

W a

O G t 34 4

tr I E

Bl G '

W>

ik 4

Ie e

N M

g c

b cp O

e N

M 9

e g

q e

e e

e e

e e-f

y 3901020600 1

OPE':r. TING DAT1 REPORT 6

DOCRET NO. 50 - 352 DATE WARCH 8.

1990 cow?LETED By PHILADELPHIA ELECTRIC COMPANY J. J. MURPHY REPORTS SUPERVISOR PROJECTS DIVISIOg LIVERICK GENERATI % STATION TELEPHONE (215) 327-1200 EXTENSION 3752 OPERATING STATUS 1

UNIT MAME: LIWERICK UNIT 1 i NOTES: THERE WERE Two LOAD l

]

l

2. REPORTING PERIOD:

FEBRUARY. 1990 1

REDUCTIONS GREATER THAN i

g

3. LICENSED THERMAL POWER (wwT):

3293 l

20% THIS WONTH.

l j

4 NAWEPLATE RATING (GROSS #wE):

1139 l

g

5. DESIGN ELECTRICAL RATING (NET mwE):

1055 l

I l

l

6. WAXIMUW CEPENDABLE CAPACITY (GROSS MwE): 1092 l

l i

7 WAXIMUM DEPENDABLE CAPACITY (NET WWE):

1055 l

I 8.

IF CHANGES OCCUR IN CAPACITV RATINGS (ITEMS NUWBER 3 THROUGH 7) SINCE LAST REPORT. GivE REASONS:

9. POWER LEVEL TO WHICH RESTRICTED. IF ANV (NET wwE):
10. REASONS FOR REST'1ICTIONS. IF ANY:

THIS MONTH va-TO-DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 672 1.416 35.736
12. NUWBER O' HOURS REACTOR wAs CRITICAL 672.0 1.416.0 28.544.8 1?. DEACToo ogsgovE S$*rTDOww WUns 0.0 0.0 0.0 14 HOURS GENERATOR ON-LINE 672.0 1.416.0 28.087.6
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (wwH) 2.193.694 4.604.336 82.467.776

-= ---

17. GROSS ELECTRICAL ENERGY GENERATED (wwH) 710.830 1.493.640 20.680.210
18. NET ELECTRICAL ENERGY GENERATED (wwH) 686.679 1.442.558 25.498.954 PAGE 1 OF 2

3901020600 OPET. TING DATO i;EPORT (CONTINUED)

DOCMET NO. SC - 352 a

b

... =

DATE MARCH 8.

1990 THIS WONTH VR-TO-DATE COMULATIVE

19. UNIT SERVICE FACTOR 100.0 100.0 78.6
20. UNIT AVAILABILITY FACTOR 100.0 100.0 78.6
21. UNIT f,APACITY FACTOR-(USING MDC NET) 96.9 96.6 67.6
22. UNIT CAPACITY FACTOR (USING DER NET) 96.9 96.6 67.6
23. UNIT FORCED OUTAGE RATE O.0 0.0 2.8 24 SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE. DATE. AND DURATION OF EACH):
25. IF SHUTDOWN AT END OF REPORT PERIOD. ESTIMATED DATE OF STARTup:
26. UNITS IN TEST STATUS (PRIOR TO COmwERCIAL OPERATION):

FORECAST ACHIEVED INITIAL CRITICALITY 12/19/84 12/22/84 INITIAL ELECTRICITY WID APRIL BS 4/13/85 COMwERCIAL OPERATION 1ST OTR 86 2/01/86 PAGE 2 OF 2

390f020600 UNIT SHUTDOWNS CND POWE4 # EDUCTIONS DOCKET NO. 50 - 352 UNIT NAME LIMERICK UNIT 1 DATE MARCH 8 1990 REPORT MONTH FEBRUARV. 1990 C0ePLETED BY PHILADELPHIA ELECTRIC COWPANY J.J. FURPHV REPORTS SUPERVISOR PROJECTS DIVISION LIMERICK GENERATING STATION TELEPHONE (215) 327-1200 EXTENSION 3T52

-__----------~~. ---...------------------

l METHOD OF LICENSEE ISYSTEM COMPONENTl CAUSE AND CORRECTIVE I

. TYPE DURATION REASON SHUTTING DOWN EVENT l CODE CODE l ACTION TO NO.I DATE (1)H (HOURS)l (2)

REACTOR (3) l REPORT a !

(4)

(5) 1 PREVENT RECURRENCE 1

l l

[

l I

4

' 900206 5

000.0 B

4 l

N/A ZZ j ZZZZZZ l LOAD WAS REDUCED 10% TO ACCOMODATE l

l l MAIN TURBINE CONTROL VALVE TESTING.

I I

I 5

900216 i S 000.0 F

4 N/A I ZZ

' ZZZZZZ l LOAD WAS REDUCED 25% TO ACComODATE A l

l CONTROL ROD PATTERN ADJUSTNENT.

1 i

i O I C00218 5

000.0 B

4 N/A I ZZ ZZZZZZ l LOAD WAS REDUCED 27% TO ACComODATE l

l ISOLATION OF A FEEDWATER HEATER FOR l

l 1

WAINTENANCE.

I I

l 7 l 400227 5

000.0 F

4 N/A ZZ l ZZZZZZ LOAD WAS REDUCED 10% DUE TO HIGH TURBINE L

BACMPRESSURE.

I I

O 1 900223 5

000.0 F

4 N/A ZZ ZZZZZZ LOAD WAS REDUCED 10% TO RETURN A 1

l l

FEEDWATER HEATER TO SERVICE AND i

I O

CONTROL ROD PATTERN ADJUSTWENTS.

g l

l l

1 1

l (1)

(2)

(3)

(4) r rORCED REASON WETHOD ENHIBIT G - INSTRUCTIONS S-SCHEDULED A - EQUIPMENT FAILURE (EXPLAIN) 1 - MANUAL FOR PREPARATION OF DATA B - MAINTENANCE OR TEST 2 - MANUAL SCRAM.

ENTRY SHEETS FOR LICENSEE C - REFUELING 3 - AUTOMATIC SCRAM.

EVENT REPORT (LER)

D - REGULATORY RESTRICTION 4 - OTHER (EXPLAIN)

FILE (NUREG-0161)

E - OPERATOR TRAINING + LICENSE EXAMINATION F - ADMINISTRATIVE (5)

G - OPERATIONAL ERROR (EXPLAIN)

H - OTHER(EXPLAIN)

EXHIBIT I - SAME SOURCE L__

3901020600 i

Docket No. 50-353

)

Attachment to Monthly Operating Report for February 1990 Limerick Generating Station Unit 2 February 1 through February 28, 1990 I

I.

Narrative Summary of Operatina Erneriences Limerick Unit 2 began the month of February at a nominal 100%

of rated thermal power.

On February 22, reactor power was reduced briefly to 90% to accommodate Main Turbine Control j

Valve testing.

Limerick Unit 2 ended the month of February at a nominal 100% or rated thermal power.

1 II.

Challences to Main Steam Safety Relief Valves There were no challenges to the Main Steam Safety Relief Valves during the month of February, l

l

(

l L

L l

~..

3901020600 f.VEZAGE DAILY UNIT POWER LEVEL DOCKET NO..SO - 353

-UNIT LINERICK UNIT 2 DATE mAqCH 8.

1990 COMPANY PHILADELPHIA ELECTRIC CDppANY j

J. J. NURPHY REPORTS SUPERVISOR PROJECTS DIVISION LIMERICK GENERATIMG STAT *ON TELEPHONE (215) 327-1200 EXTENSION 3752

  1. 0 NTH FEBRUARY 1990 DAY AVERAGE DAILV POWER LEVEL DAY AVERAGE DAILV POWER LEVEL (WWE-NET)

(wwE-NET) 1 1072 17 1072 2

1070 18 1071 3

1075 19 1071 4

1069 20 1073 5

1077 21 1074 6

1075 22 1061 7

1068 23 1064 8

1072 24 1072 9

1070 25 1073 10 1070 26 1073 11 1072 27 1072 12 1073 28 1070 13 1070 14 1072 15 1072 16 1070

~

3901020600 OPET. TING DATA REPORT DOCKET NO. 50 - 353 DATE MARCH 8. 1990 COMPLETED BY PHILADELPHIA ELECTRIC COMPANY J. J. MURPHY REPORTS SUPERVISOR PROJECTS DIVISION LIMERICK GENERATING STATION TELEPHONE (215) 327-1200 EXTENSION 3752 OPERATING STATUS

1. UNIT NAME: LIMERICK UNIT 2 i NOTES: THERE WERE NO LOAD 1

1 I

2. REPORTING PERIOD:

FEBRUARV. 1990 REDUCTIONS OF 20% OR I

l

3. LICENSED THERMAL POWER (Mwr):

O l

GREATER THIS MONTH.

l l

1 4 NAMEPLATE RATING (GROSS MwE):

1138 l

l g

5. DESIGN ELECTRICAL RATING (NET MwE):

1055 l

l 1

I

6. MAXIMUM DEPENDA9LE CAPACITY (GROSS MwE): -

l I

I I

7 MAXIMUM DEPENDABLE CAPACITV (NET MWE):

l l

B.

IF CHANGES OCCUR IN CAPACITV RATINGS (ITEMS NUwSER 3 THROUGH 7) SINCE LAST REPORT. GIVE REASONS:

9.

POWER LEVEL TO MHICH RESTRICTED. IF ANY (NET WWE):

10. REASONS FOR RESTRI CTI ONS. IF ANY:

THIS MONTH VR-TO-DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 672 1.248 y

g

12. NUMBER OF HOURS REACTOR WAS CRITICAL 672.0 1.248.0 1.248.0
13. REACTOR RESERVE SHUTDOWN HOUDS 0.0 0.0 0.0 14 HOURS GENERATOR ON-LINE 672.0 1.248.0 1 248 0
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MwH) 2.211.1h2 4.103.22h 4.103.229
17. GROSS ELECTRICAL ENERGY GENERATED (MwH) 7k6$57b 1.386.220 1.386$220
18. NET ELECTRICAL ENERGY GENERATFD (MwH) 719,792 1.337.125 1.337.125 PAGE 1 OF 2

3901020600 OPERATING DATA REPORT (CONTINJC)

DOCKET MO. 50 - 353 DATE WARCH 8 1990 THIS MONTH VR-TO-DATE CUwULATIVE

19. JNIT SERVICE FACTOR 100.0 100.0 10 M
20. UNIT AVAILABILITY FACTOR 100.0 100.0
21. UNIT CAPACITY FACTOR (USING #DC NET) 101.5 101.6 101.6
22. UNIT CAPACITY FACTOR (USING DER NET) 101.5 101.6 1g1,6
23. UNIT FORCED OUTAGE RAYE O.0 0.0 0.0 24 SHUTDOWNS SCHEDULED OVER NEXT 6 WONTHS (TYPE. DATE. AND DURATION OF EACH)e
25. IF SHUTDOWN AT END OF REPORT PERIOD. ESTIMATED DATE OF STARTUP:
26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION):

FORECAST ACHIEVED INITIAL CRITICALIrv 8/12/89--


8/12/89 INITIAL ELECTRICITY JLO_1R L JM&9 C0m=ERCIAL OPERATION 2/01/90 1/08/90

  • NOT APPLICABLE PRIOR TO C0mwERCIAL OPERATION PAGE 2 0F 2 N

3901020600

~

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCRET NO. 50 - 353 l

UNIT NAWE LIMERICK UNIT 2 f

DATE MARCH 8 1990 t

l REPORT MONTH FE8RUARY. 1990 COMPLETED BV PHILADELPHIA ELECTRIC COMPANY L

J. J. MURPHY REPORTS SUPERVISOR PROJECTS DIVISION LIWERICR GENERATING STATION TELEPHONE

5) 327-1200 ERTENSION 3752 l

I I #ETHOD OF l LICENSEE SYSTEWICOMPONENTI CAUSE AND CORRECTIVE ITYPElDURATION REASONISHUTTING DOWN1 EVENT CODE I CODE l ACTION TO NO.

DATE I (1)l (HOURS)1 (2) l REACTOR (3) l REPORT a ll (4) l (5) l PREVENT RECURRENCE I

I I

I I

I I

I I

I I

I I

I I

3 900222 S

000.0 8

4 l

N/A I

ZZ' ZZZZZZ l LOAD WAS REDUCED 10% TO ACC0400 ATE I

l l MAIN TURBINE CONTROL VALVE TESTING.

I i

1 1

I i -

1 I

I (t)

(2)

(3)

(4)

F - FORCED REASON METHOD EXHIBIT G - INSTRUCT 70MS S - SCHEDULED A - EQUIPMENT FAILURE (EXPLAIN) 1 - MANUAL FOR PREPARATION OF DATA B - WAINTENANCE OR TEST 2 - MANUAL SCRAM.

ENTRY SHEETS FOR LICENSEE C - REFUELING 3 - AUTOMATIC SCRAw.

EVENT REPORT (LER)

D - REGULATORY RESTRICTION 4 - OTHER (EXPLAIN)

FILE (NUREG-0161)

E - OPERATOR TRAINING + LICENSE EXAMINATION F - ADMINISTRATIVE (5)

G - OPERATIONAL ERROR (EXPLAIN)

H - OTHER(EXPLAIN)

EXHIBIT I - SAWE SOURCE m

i L.

3901020600 Docket No. 50-353 Attachment to Monthly f))

Operating Report for

(

February 1990 Limerick Generating Station Unit 2 February 1 through February 28, 1990 I.

Narrative Summary of Ooeratina Exoeriences Limerick Unit 2 began the month of February at a nominal 100%

of rated thermal power.

On February 22, reactor power was reduced briefly to 90% to accommodate Main Turbine Control Valve testing.

Limerick Unit 2 ended the month of February i

at a nominal 100% or rated thermal power.

1 II.

Challences to Main Steam Safety Relief Valves There were no challenges to the Main Steam Safety Relief Valves during the month of February.

l 'd i-l 1

L l

O l

---e 73p-y o

i

, ~.

(_'_

3$020600 b

AVEOfGE DAILV UNIT P0wEM LEVEL e

DOCKET NO. 50 - 353 UNIT LINERICK UNIT 2 l

l DATE MARCH 8, 1990 COMPANY PHILADELPHIA ELECTRIC COWPANY l

J.

J. wuRPHY REPORTS SUPERVISOR PROJECTS DIVISION LINERICK GENERATING STATION TELEPHONE (215) 327-1200 EXTENSION 3752 MONTH FEBRUARY 1990 DAY AVERAGE DAILY power LEVEL DAY AVERAGE DAILV POWER LEVEL (MwE-NET)

(WWE-NET) 1 1072 17 1072 2

1070 18 1071 3

1075 19 1071 4

1069 20 1073 5

1077 21 1074 6

1075 22 1061 7

1068 23 1064 4

8 1072 24 1072 9

1070 25 1073 10 1070 26 1073 11 1072 27 1072 12 1073 29 1070 13 1070 14 1072 15 1072 16 1070

m a

(D U

3901020600 L

%/

OPERTING DATA REPORT 9

DOCKET NO. 50 - 353 DATE MARCH 8, 1990 COMPLETED BV PHILADELPHIA ELECTRIC COMPANY 9

J. J. MURPHY REPORTS SUPERVISOR l

PROJEC15 O! VISION l

LIMERICK GENERATING STATION TELEPHONE (213) 327-1200 EXTENSION 3752 OPERATING STATUS 1 UNIT NAME: LIMERICK UNIT 2 l NOTES: THERE wERE NO LOAD l

j

2. REPORTING PERIOD:

FEBRUARY. 1990 REDUCTIONS OF 20% OR

3. LICENSED THERMAL POWER (MwT):

O I

GREATER THIS MONTH.

l l

4 NAMEPLATE RATING (GROSS MwE):

1138 I

5. DESIGN ELECTRICAL RATING (HET WWE):

1055 I

I

6. MAXIMUM DEPCNDABLE CAPACITY (GROSS WWE): -

l t

7. MAXIMUM DEPENDABLE CAPACITY (NET MwE):

I 8.

IF CHANGES OCCUR IN CAPACITV RATINGS (ITEMS NUMBER 3 THROUGH 7) SINCE LAST REPORT. GIVE REASONS:

9. POWER LEVEL TO WHICH RESTRICTED. IF ANY (NET MWE):
10. REASONS FOR RESTRICTIONS. IF ANY:

THIS MONTH VR-TO-DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 672 1.245 y

g

12. NUMBER OF HOURS REACTOR WAS CRITICAL 672.0 1.248.0 1.248.0
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 00 14 HOURS GENERATOR ON-LINE 672.0 1.248.0 1.248.0 t
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MwH)

---=--

2.211.182 4.103.229 4.103.229

17. GROSS ELECTRICAL ENERGY GENERATED (MwH) 746.470 1.386.220 1.386.220
18. NET ELECTRICAL ENERGY GENERATED (MwH)

T19.792 1.337.125 1.337.125 PAGE 1 OF 2

n)

-(~T 3901020600 I_,

~

Q, OPE 3 TING DATA LEPORT-(CONTINUED).,)

N.

v' DOCKET NO. 50 - 353 e

DATE WARCH 8 1990 THIS MONTH VR-TO-DATE CUwULATIVE

19. UNIT SERVICE FACTOR 100.0 100.0 1_0_ _0_._0
20. UNIT AVAILABILITY FACTOR 100.0 100.0 g
21. UNIT CAPACITY FACTOR (USING WDC NET) 101.5 101.6 101.6
22. UNIT CAPACITY FACTOR (USING DER NET) 101.5 101.6 101.6
23. UNIT FORCED OUTAGE AATE O.0 0.0 0.0

_=

24 SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE. DATE. AND DURATION OF EACH);

i

25. IF SHUTDOWN AT END OF REPORT PERIOO. ESTIMATED DATE OF STARTUP:
26. UNITS IN TEST STATUS (P;IOR TO COMMERCIAL OPERATION):

FORECAST ACHIEVED INITIAL CRITICALITY 12/gg gg INITIAL ELECTRICITY

_N0lML

_MM_9 COMMERCIAL OPERATION

__2_/_01/90

__1_/08 / 9_0

=-

  • NOT APPLICABLE PRIOR TO COuwERCIAL OPERATION PAGE 2 OF 2

,y e

r-

~

-,w,

,7-.-

i -- *,*

.,,e,,

,o,.,,

a

.zm 3901020600

- ~

k

/

l UNIT SHUTDOWNS CND PowE3 E. EDUCTION 3 DOCMET NO. 50 - 353 UNIT NAME LI#ERICE UNIT 2 DATE WARCH 8.

1990 REPORT #0 NTH FEBRUARY. 1990 CO#PLETED BV PHILADELPHIA ELECTRIC COWPANY l

J. J. WURPHY REPORTS SUPERVISOR PROJECTS DIVISION LIWERICK GENERATING STATION TELEPHONE (215) 327-1200 EXTENSION 3752

=

l l

l l WETHOD OF l LICENSEE iSYSTEWICOw?ONENTl CAUSE AND CORRECTIVE l

lTYPElDURATIONlREASONISHUTTING DOWNI EVENT l CODE I CODE l ACTION TO NO.1 DATE l (1)I (HOURS)l (2) l REACTOR (3) i REPORT a I (4) l (5) i PREVENT RECURRENCE 1

I i

3 I

I I'

I I

I '

I I

I i

l l

3 l 900222 1 S i 000.0 B

4 N/A ZZ l ZZZZZZ LOAD wAS REDUCED 10% TO ACCOMODATE l

I l

l l

MAIN TURBINE CONTROL VALVE TESTING.

1 I

i ----- l I

I i

1 -

1 I

l I

(1)

(2)

'(3)

(4)

F - FORCED REASON WETHOD EXHIBIT G - INSTRUCTIONS S - SCHEDULED A - EQUIPMENT FAILURE (EXPLAIN) 1 - MANUAL FOR PREPARATION OF DATA B - WAINTENANCE OR TEST 2 - MANUAL SCRAM.

ENTRY SHEETS FOR LICENSEE C - REFUELING 3 - AUTOwATIC SCRAW.

EVENT REPORT (LER)

D - REGULATORY RESTRICTION 4 - OTHER (EXPLAIN)

FILE (NUREG-0161)

E - OPERATOR TRAINING + LICENSE EXAMINATION F - A DMINI ST R ATI VE (5)

G - OPERATIONAL ERROR (EXPLAIN)

H - OTHER(EXPLAIN)

EMHIBIT I - SAWE SOURCE