ATTACHMENT 2 PROPOSED TECHNICAL SPECIFICATION CHANGE 5.3.1 A1/009,N12 9003130497 900301

-PDR ADOCK 0500049;8 P

pnt

r c.

. ELSMHIEAIVRES 5.3: REACTOR CORE FUEL ASSEMBLIES-5.3.1-The core shall contain 193 fuel assemblies with each fuel assembly con-taining 264 fuel rods cla'd with Zircaloy-4.

Each fuel rod shall have a nominal active fuel length of 168 inches.

The initial core loading shall have a maxi-num enrichment of 3.5 weight percent U-235.

Reload fuel shall be similar in physical _ design to the it:itial core loading and shall have a maximum enrichment ofJ5weightpercentU-235.

CONTROL R00 ASSEMBLIES

-5.3.2 The core shall contain 57 full-length control rod assemblies.

The full-1ength control rod assemblies shall contain a nominal 158.9 inches of absorber material.-

The absorber material within each assembly shall be silver-indium-

' cadmium or. hafnium.

Mixtures of hafnium and silver-indium-cadmium are not

--permitted within a bank. All control rods shall be clad with stainless steel tubing.

5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE 5.4.1 The Reactor Coolant System is de's'iined and shall be maintained:

In accordance with the Code requirements specified in Section 5.2 a.

of the FSAR, with allowance for normal degradation pursuant to the applicable Surveillance Requirements; b.

For a pressure of 2485 psig, and j

For a temperature of 650'F, except for the pressurizer which is 680'F..

c.

VOLUME 5.4.2 The total water and steam volume of the Reactor Coolant System is 13,814

+ 100 cubic feet.at'a nominal T,yg of 561*F.

5. 5 METEOROLOGICAL TOWER LOCATION 5.5.1 The meteorological towers shall be located as shown on Figure 5.1-1, 5.6 FUEL STORAGE CRITICALITY 5.6.1 -The spent fuel storage racks are designed and shall be maintained with:

A k,f7 equivalent to less than or equal to 0.95 when flooded with a.

unborated water, which includes a conservative &1lowance of SOUTH TEXAS - UNITS 1 & 2 5-6 Unit 1 - Amendment No. 2,10 i

Unit 2 - Amendmer.t No. 2

[

,g

f

'i

'd:

[

I

'[ t '

  • _t.'

ATTACHMENT 3 CRITICALITY ANALYSIS OF THE

. SOUTH TEXAS. UNITS 1 AND 2 FRESH FUEL RACKS

- A1/009,N12 4