SNUPPS Pandardized Nuclear Unit 5%=or Plant System 5 Choke Cherry Road Nicholas A. Petrick Rockville, Maryland 20850 Executive Director (301) seseoto September 18, 1981 SLNP.C 81-107 FILE: 0278 SUBJ: Pump and Valve Test Program 61] Atj'.9 3

Mr. Harold R. Denton, Director

, ?'/

2,I k j} 9 Office of Nuclear Reactor Regulation 4[F / q h,o#g,y' U.S. Nuclear Regulatory Commission Washington, D. C.

20555 D

Docket hos. STN 50-482, STN 50-483, and STN 50-486 k

' $@%, f.% y';

e J/

yA Ref: SLNRC 81-89, dated September 5, 1981, same subject

\\(p, ef

Dear M:

. Denton:

The referenced letter provided the Callaway Unit 1 pump and valve test program and explained the similarity to that for Wolf Creek.

In dis-cussions with the NRC's Mechanical Engineering Branch, it was learned that some changes to the program were required. The attachment to this letter provides revised pump relief request no. 2 and revised valve relief requests nos.1, 6, 7, 8, and 9.

Ir. addition, a new page (128A) has been added to include four check valves in the compressed air system. These changes are applicable to both Callaway Unit 1 and Wolf Creek.

Very truly vours, 44C Nicholas A. Petrick RLS/jdk Attachment cc:

J. K. Bryan UE G. L. Koester KGE D. T. McPhee KCPL D. F. Schnell UE W. A. Hansen NRC/ CAL T. E. Vandel NRC/WC 3ODI s

ll{

t 8109290500 810918 PDR ADOCK 05000482 A

PDR.

l l

L

PUMP RELIEF REQUEST NO. 2 SYSTEM:

Emergency Fuel Oil System COMPONENT:

PJE01A & PJE01B CLASS:

3 FUNCTION:

To provide fuel oil to the standby diesel generators.

TEST REQUIREMENT:

Measure bearing temperature and vibration and observe lubricant level.

BASIS FOR RELIEF:

There pumps are immersable centrifugal sump pumps located in the emergency fuel oil storage tanks.

ALTERNATE TESTING:

Vibration measurements will be made on the connecting piping quarterly.

SD e

)

~

VALVE RELIEF REQUEST NO. 1 SYSTEM:

Auxiliary Feedwater P&ID No:

M-02AL01 COMPONENT:

V006 V009 V012 V015 CATEGORY:

C CLASS:

3 FUNCTION:

Valves open with differential pressure to provide ?!1ow paths from Essential Service Water System to Auxiliary Feedwater Pumps during a DBA.

Normally closed.

TEST REQUIREMENT:

Exercise the valves every three months.

BASIS FOR RELIEF:

The testing of these valves would result in supplying chemically contaminated water to the steam generators and/or the con-densate storage tank.

i ALTERNATE TESTING: "

Valves v.ill be cuded manually during refueling.

VALVE RELIEF REQUEST NO. 6 SYSTEM:

Accumulator Safety Injection P&ID NO:

M-02EP01 COMPONENT:

8956A through 8956D i

CATEGORY:

C CLASS:

1 FUNCTION:

Opens with differential pressure to provide flow paths from the accumulators to the reactor coolant system cold legs and the reactor vessel.

Normally closed.

TEST REQUIREMENT:

Exercise valves once every three months.

BASIS FOR RELIEF:

During normal operation, the safety injection system has insufficient head to overcome reactor coolant system pressure.

Testing during shut-down increases the probability of a cold over-pressurization event to occur and is therefore in conflict with plant safety.

ALTERNATE TESTING:

A partial stroke exercise of the valves will be performed during cool down for refueling.

A

VALV_E RELIEF REQUEST NO. 7 SYSTEM:

Containment Spcay System P&ID NO:

M-02EN01 COMPONENT:

V002 V008

_ CATEGORY:

C CLASS:

2 TUNCTION:

Opens on differential pressure to supply containment spray water to the discharge nozzles in the recirculation moce.

TEST REQUIREMENT:

Exercise valves once every three months.

BASIS FOR RELIEF:

Valves can not be stroke exercised withouti violating the integrity of penetration numbers P-13 and P-16.

ALTERNATE i

TESTING:

These valves will be cycled manually in conjunction with the system air test per Technical Specification.

5

VALVE RELIEF REQUEST NO. 8 SYSTEM:

Containment Spray System P&ID NO:

M-02EN01 COMPONENT:

V003 V004 V009 V010 CATEGORY:

C CLASS:

2 FUNCTION:

Opens with differential pressure to provide flow paths for the containment spray system.

normally closed.

TEST REQUIREMENT:

Exercise valves once every three months.

BASIS FOR RELIEF:

Pumps can only be tested at partial flow (per FSAR section 6.2.2.1.4).

Therefore, valves in flowpath can only be tested at partial flow.

ALTERNATE TESTING:

Partial flow test the check valves when the spray pumps are tested by recirculation flow back to the RHST.

I.

VALVE RELIEF REQUEST NO. 9 SYSTL.,

Containment Spray System P&ID NO:

M-02EN01 COMPONENT:

V013 V017 CATEGORY:

C CLASS:

2 FUNCTION:

Opens with differential pressure to provide flowpaths for the containment spray he'ader.

Normally clo.:ed.

TEST REQUIREMENT:

Exercise valves once every three months.

BASIS FOR RELIEF:

Normal flowpath cannot be used without dis-charging containment spray water from the nozzles.

f ALTERNATE TESTING:

These valves will be partial stroke tested by air flow l

during the system air test per Technical Specification.

i h

l

]

L.

S"'a'?"'

INSERVICE TESTING PROGRAM rower E

Production ISI CLASS 1,2 & 3 VALVES Engineering "ly" ',,,,,

CALLAWAY NUCLEAR PLANT P&10 R EVISION - D ATE PAGE M-02KA05 o

9/81 128A of 137 SYSTEM COMPRESSEP AIR SYSTEM d

O 4

R EM ARKS O

4 4

g4 q,

q.

VALVE NUMBER

/

Vo48 46 3

A 3/4" CK SA C

C AT RR Note 9

Vo49 F-d 3

A 3/4" CK SA C

C AT RR Note 9 Vobo D-6 3

A 3/4" CK SA C

C AT RR Ncte 9 l.

Vot,1 u-b 3

A 3/4" CK SA C

C AT RR Note 9 i

r

$0 i

4 w