ML20010H738

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept Re Reactor Bldg Hatch Cover Initially Reported on 810820.Cover Will Be Redesigned to Be of Sufficient Weight to Prevent Uplift During LOCA Conditions & Will Be Installed by 821031
ML20010H738
Person / Time
Site: Bellefonte  
Issue date: 09/21/1981
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8109290249
Download: ML20010H738 (2)


Text

--

4-6-

6-TENNESSEE VALLEY AUTf40RITL, i mnv CH ATTANOOGA. TENNESSEE /37400 'T; r'$

pg 400 Chestnut Street Tower II si sP N AS: 32 September 21,-1981 BLRD-50-438/81-55

'i BLRD-50-439 /81-57

/

O V s",gg /g /

i

\\-

5 Mr. Janes P. O'Reilly, Director g

N.'.

%,f' w %

Office-of Inspection and Enforcement f

U.S. Nuclear Regulatory Commission

'O Region II - Suite-3100

/n.

101 Marietta Street Cu / )

,g tu Atlanta, Georgia 30303

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR'PLAMT UNITS 1 AND 2 - REACTOR BUILDING HATCH COVER - BLRD-50-438/81-55, -439/81 FINAL REPORT The subject deficiency was initially reported to-NRC-0IE Inspector R..V. Crienjak on August 20, 1981, in accordance with'10 CPR 50.55(e) as NCR BLN BLP.81?3 Enc.osed is our-final report.

If you Pave any questions, please oc'I Pave Lambert at FTS 857-2581.

Very trulv yours, TENNESSEE VALLEY AUTHORITY bb gjj e

e L.'

M. Mill 5, Manager Nuclear Regulation and-Safety Enclosure cc:

Mr. Victor Stello, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatorv Commission Washington, DC 20555 Tb Sih a

f8109290249 810921

>;PDR ADOCK 05000438 i

S PDR.

An Equal Opportunity Employer

R

'I 4

FNCLOS!!RE BELLEFONTE NUCLEAR PLANT UNITS 1 A!ID 2 REACTOR BUILDING HATCH COVER 10 CFR 50.55(e)

BLRD-50 438/81-55,~ h39/81-57 FINAL REPORT Description of Condition 4

Potential LOCA prassures were not included in the design of each Reactor Building hatch cover at elevation 646.

The weight of the hatch cover, as presently designed, is not sufficient to prevent uplift because of potential differential pressure _between Peactor Building floors. The LOCA preu ures were rot included in the design of the baten because of a designer oversight.

Safety Inplications If pressure differentials became such that the hatch cover could

' t aome a projectile or uplift and fal! b=.ek through the opening to the 622 floor, safety class equipment could possibly incur damage.

Corrective Action The hatch cover will be redesigned to ne of sufficient weight to prevent uplift during LOCA conditions by August 31, 1982. The redesigned. hatch cover will be inst alled by October 31, 1082.

TVA's review has shown that this As an isolated deficiency which~is not connon to all hatch cover designs. The deficiency occurred because of designer oversight. The individual. involved in the-subject deficiency has bccn reinstructed in TVA design procedures.

e

+'$

L'Ma' ky+-

J C

=

.