ML20010H722

From kanterella
Jump to navigation Jump to search
Forwards LERs 81-038/03L-0,81-057/81-03L & 81-058/03L-0
Date released: 01/24/2020 Download: ML20010H722


LER 81-058/03L-0:on 810906,smoke Detector Sys Battery Would Not Accept Charge.Caused by Removal of Line Fuse by Electrician.Line Fuse Replaced & Sys Returned to Svc
ML20010H728
Person / Time
Site: Surry Dominion icon.png
Issue date: 09/22/1981
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20010H728 (2)
LER 81-057/03L-0:on 810827,circuit Breaker for Motor Operated Valve Found Open.Caused by Accidental Bumping. Breaker Reclosed & Appropriate Valve Indication Ack
ML20010H727
Person / Time
Site: Surry Dominion icon.png
Issue date: 09/22/1981
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20010H727 (2)
LER 81-038/03L-0:on 810827,circuit Breaker for Motor Operated Valve 1860A Was Found Open.Caused by Accidental Bumping.Breaker Reclosed & Appropriate Valve Indication Verified
ML20010H726
Person / Time
Site: Surry Dominion icon.png
Issue date: 09/22/1981
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20010H726 (2)
Forwards LERs 81-038/03L-0,81-057/81-03L & 81-058/03L-0
ML20010H721
Person / Time
Site: Surry Dominion icon.png
Issue date: 09/22/1981
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20010H721 (1)