05000366/LER-1981-079-03, /03L-0:on 810822,torus-to-atmosphere Hi Data Processing Switch 2T48-N210 Found to Actuate Above Tech Spec Limit During Static O-ring Pressure Switch Calibr HNP-2-5240.Caused by Setpoint Drift.Switch Recalibr

From kanterella
(Redirected from ML20010G577)
Jump to navigation Jump to search
/03L-0:on 810822,torus-to-atmosphere Hi Data Processing Switch 2T48-N210 Found to Actuate Above Tech Spec Limit During Static O-ring Pressure Switch Calibr HNP-2-5240.Caused by Setpoint Drift.Switch Recalibr
ML20010G577
Person / Time
Site: Hatch 
Issue date: 09/10/1981
From: Coggin C
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20010G571 List:
References
LER-81-079-03L-01, LER-81-79-3L-1, NUDOCS 8109220240
Download: ML20010G577 (2)


LER-1981-079, /03L-0:on 810822,torus-to-atmosphere Hi Data Processing Switch 2T48-N210 Found to Actuate Above Tech Spec Limit During Static O-ring Pressure Switch Calibr HNP-2-5240.Caused by Setpoint Drift.Switch Recalibr
Event date:
Report date:
3661981079R03 - NRC Website

text

NRC FORM 3GG U.S. NUCLEAR REGULATORY COMMISSION (7 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

10111 l cl Al El Il Hl 2l@l 0101 -i 010 l 010 l 0 l-10 l 01@l41111 l1 l11@l I

l@

7 8 9 LICENSEE CODE 19 IS LICENSE NUMBER 26 26 LICENSE TYPE JO 57 CAT 68 CON'T I0l11 5O n% l Ll@l 015 l 0 l 0 l 0 l 3 l 6 l 6 l@l 0 l 8 l 2 l 2 l 8 l 1 l@l 0 l 9 l 1 l 0 l 8 l1 l@

7 8

60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h 1012; lWith the plant ir steady state operation at 1104 MWt and while pertorm-1 i O i 3, ling HNP-2-5240, Static O-Ring Pressure Sp.tch Calibration, the Torus-l0 pl I to-Atmosphere Hi DP Switch, 2T48-N210, was found to actuate at 17 inchesl iOis;lW,C. Vac.

Tech Specs 3.6.4.2 require actuation at _4.5 PSID or 14 inchek F6171 i W.C. Vac.

Reddndant Switch 2T48-N211 was found to be within tolerance. I l Plant operation nor the health and safety of the pr511c was affected.

I O 7 iOiRi dhis is a non-repetitive event.

I 80 7

8 9

~

DE CODE SUBC DE COMPONENT CODE SU8 CODE S

E lO19l l Sl Hl@ [X_j@ l Z l@ lI IN lS,lT lR IU lh [S_j@ [Z_j @

7 8

9 to 12 13 18 19 20 SEQUENTI AL OCCURRENCE REPORT REVISION LE R 'RO EVENT YE AR REPORT NO.

CODE TYPE N O.

@sgog I 8l 11 L_J 1017191 M

l ol 2J ILI

(-j [0_]

a

_ 21 22 23 24 26 27 28 49 30 31 32 KEN AC O ON PLANT M

HOURS 22 SB IT FOR b 8.

SUPPLIER MANUFACTURER l 4@l 4@

l 21@

lZl@

l010 l0 l0 l lY l@

[N_j@

l Al@

lSl318j2l@

JJ 34 35 36 3/

40 41 42 13 44 47 CAUSE DESCRIPTION ANG COdRECTIVE ACTIONS h i iitOi lThe cause of this event has been attributed to setpoint drift.

The I

l switch was recalibrated per HNP-2-5240, Static O-Rine Pressure Switch I

i i l Calibration and returned to service.

No further corrective action was I

i,,3i I found necessary.

No additional reports follow.

I I

U_L_1 1 80 7

8 9 i

ST S

% POWER OTHE R STATUS DIS O RY DISCOVERY DESCRIPTION LU s_j l El@ l0 l 415 l@l NA l

[B_j@[ Perforndna Norm 1 Surveillance l

A flVITY CC TENT L/J @ LJ@l AMOUNTOF ACTIVITY @ j LOCATION OF RELEASE RELWED OF MLEASE NA l

NA i

i o PERSONNEL EoOSSES oESCRIPT.%@

NUMBER TvPE Li_L7_j [?l010_j@Lgj@l BA l

nRSoNNabu'J,ES otSCniPfiO~@

NuMsER

. lilRIl0101Ol@l w

I l

7 8 9 11 12 80 LOSS OF OR DAMAGE TO FACluTY h TYPE DE SCRIP TION v

L I

li l 91 L3J@l m

80 l '

" 9

'o 8109220240 810910 issue @ DESCRIPTION @

PDR ADOCK 05000366 NRC USE oNLY i

S PDR l

lllllll!lllll7 Q

l m

68 69 80 5 7

8 9 10 C. L. @@ - 4t. &, W. &w.

M N -MM y,

pgoyg w Aur ne onrPanrn u

LER #:

50-366/1981-079 Licensee:

Georgia Power Company Facility Name:

Edwin I. Hatch Docket #:

50-366

Narrative

Report for LER 50-366/1981-079 On August 22,

1981, while the plant was in steady state operation at 1104 MWt and while performing HNP-2-5240, Static 0-Ring Pressure Switch Calibration, the Torus-to-Atmosphere High DP Switch, 2T48-N210, was found to actuate at 17 inches W.C.

Vac.

Tech Specs 3.6.4.2 require actuation at less than or equal to

.5 PSID or 14 inches W.C.

Vac.

This switch and its redundant switch 2T48-N2' ' control butterfly valves which are used in equalizing excessive cressure differences between the torus and the atmosphere which may result due to steam leaks withtr.

the drywell.

Failure of these switches may result in tacessive torus vacuum and possible _ damage to its penetration seals.

Redundant _ switch 2T48-N211 was found to be within tolerance.

Plant operation nor the health and safety of the public was affected.

This is a non-repetitive event.

The

cause

of this event has been attributed to setpoint drift.

The switch was recalibrated per HNP-2-5240, Static 0-Ring Pressure Switch Calibration and returned to service.

Since Unit 1 does not use the same type switch for this application, no generic problem exists.

4