05000237/LER-1981-053-03, /03L-0:on 810817,trip Point of 1 Refueling Floor ARM Found to Be Above Tech Spec Limit.Caused by Setpoint Drift.Arm Alarm & Trip Setpoint Reset to Comply W/Tech Spec Requirement

From kanterella
(Redirected from ML20010G025)
Jump to navigation Jump to search
/03L-0:on 810817,trip Point of 1 Refueling Floor ARM Found to Be Above Tech Spec Limit.Caused by Setpoint Drift.Arm Alarm & Trip Setpoint Reset to Comply W/Tech Spec Requirement
ML20010G025
Person / Time
Site: Dresden 
Issue date: 09/03/1981
From: Coen R
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20010G010 List:
References
LER-81-053-03L, LER-81-53-3L, NUDOCS 8109150241
Download: ML20010G025 (2)


LER-1981-053, /03L-0:on 810817,trip Point of 1 Refueling Floor ARM Found to Be Above Tech Spec Limit.Caused by Setpoint Drift.Arm Alarm & Trip Setpoint Reset to Comply W/Tech Spec Requirement
Event date:
Report date:
2371981053R03 - NRC Website

text

.._

NRC FORA 4 ?,64

-~ - --

U.S. NUCLEAR REGULATCRY COMMISSION (7 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

[olij l I l L l D l R l S l 2 l@l 0 l 0 l-l 0 l0 l0 l0 l0 [- l 0 l 0 l@l 4 l 1 l 1 l1 l 1 l@l l

l s7 GAT s8 @

7 8 9 ucaNstE coot 14 1s uCENsE NuuSEa 2s 26 ucENSE TYPE JO CON'T lol1l l L hl 0 l 5 l 0 l 0 l0 l 2l 3l 7 @l 0 l 8 l 1 l 7 l 8 l 1 @[0 l 9 l0 l 3 l8 l 1l@

~

ntpon 3oypC

?

8 80 81 ooCKET NuMSER 68 89 EV ENT oATE 74 7s MEPORT oATE 80 EVENT DESCRIPTION AN0 PROS A8LE CONSECUENCES h l o l 21 l During surveillance testine-the trip point of 1 Refueling Floor ARM was found to be l

i o l a 1 l above the limit required by Tech. Spec. 3.2.E.3.

There was no effect on the public l

I o I 4 I l healt's and safety as all redundant Refueling Floor ARM's were operable during the event.l [oIsl l Previous occurences: RO 50-249/81-7 and R0 SCw249/79-17.

l 10161l I

lo171I l

10181 l l

7 8,

80 SoE To"o'E s58E5E sus "o'oE Bl Al@ W@ W@ lIl NI S j T ;R lu ;g gg ]Yg COMPONENT Coof 5

t o_.it i

7 8

9 10 11 12 IJ 18 9

20 SEQUENTIAL OCCURRENCE REPomT Revision LEN>Ro EVENT YEAR REPoMT No.

Coo 8 TYPE No.

h aE l8 l1 I l-l l 0l 5l 3l l/l l0 l3 l lLl l-l l0l 21 32 23 24 28 27 28 29 30 31 32 QN oP T

M Hours 22 s8 i PCR 8.

Su UE MAN P C RER gl34Z [ g l5Z [g [8 Zlg l0 l 0l 0l l

g g g g lN[g lGl0l8)0l~g 33 3

3 37 40 4'

42 43 44 47 -----

CAUSF "JESCRIPTION AND CORRECTIVE ACTIONS h i s l o l l The causc of the event was scyeint drif t.

The Adi Alarm and trip setpoint was reset l

yl from the as found 105 mr per hour to comply with the Technicsi Specification requiremenq.

g l Repeatabi]sry was verified.

Functional testing of the Refueling Floor rad. monitors l

g l will continue on a monthly basid.

l LLL4_J L 1

7 8 9 80 oTHEnsTATus h 5'sEoSEny" h

's'12I2 sPowEn oiscovEnv oEsCaiPTioN 11 15l W h l0l5l8l@l NA l

lB l@l Monthly surveillance testing l

ACTtytTv Co TENT mELEAss AMOUNT op ACTIVITY LOCATION oF RELEASE [t_ j_6_l l 2 l @o op mtLEAstWQl NA l

l NA l

PEnsoNNE$ ExPosuAEs oEsCaiPTios h 9uM8En TvPE l ' l 7 l [ 0 l 0 l 0 @l Z @l NA j

PEnsoNNEL iNEdits otscr,iPrioNh l

l Nuv8Ea l l1 l a l l 0 l 0 l 0 l@l NA l 7 8 9 11 12 80 Loss of om DAMACE To PActLITY TYPE oESCRIPTioN l Q' l Z@

8109150241 10903 P

So

  • S

'O PDR ADOCK 05000237 l

oE3cni,TiaN @

S 8 PDR NRC USE ONLY

'"C*

lFITo'l,33381 NA I

i iiIiiIiIIi!Ii I 7 8 9 to 68 89 80 = $

PHnNF'..

NAME OF PRCP AFR

/O DEVIATION REPORT e

(9 DV R NO.

Commonwealth Em.. son STA UNIT YEAR N O.

D 2 96 PART 11 TI TLE OF DEVI ATION OCCU RRED 8-17-81 Unit 2 Fuel Pool ARM High Rad.

- 0900 DATE HME SYSTEM AFFECTED 1700

PLANT CONDITIONS

TESTING UC C Process Rad. Monitors Run 1478 438 ygs no MODE AwRivwT)

, LOAD (MWE)

DESCRIPTION OF EVENT

While conducting surveillance DIS 1700-7, the ARM alarm and trip unit for the Unit 2 Fuel Pool Area was found to trip at 105 mr/hr. (Tech Spe,. limit - 100mr/hr) Tech. Spec. 3.2.E.3.

DESCRIPTION OF CAUSE Undetermined DTHER APPLICABLE INFORMATION Reset alarm and trip unit.

Repeated check of trip point 3 times, trips ok at 95 mr/hr.

EQUIPMENT C VES OR NO.

WR NO.

Donald C. Reierson 8-17-81 FAILLRF v NO N/A N/A gg5PONSIBLE SUPERVISOR DATE PART 2_j OPERATING ENGINEERS COMMENTS Unit 3 Fuel Pool Area Radiation Monitor was operable. In additic% two ot.her area radiation

_gtyitor were operable on Unit 2.

SAFETY-TYPE OF CEVIATION EVENT OF POTENTIAL TECH SPEC NON-REPORTABLE ANNUAL RELATED REPORTABLE 0] URRENCE PUBLIC INTEREST VIOLATION OCURRENCE REPORTi t;G WR ISSUED 10CFR21 YES X YES 14 CAY lXl30 CAY NTFCT N NO NO n

REPORTABLE CCCURRENCE ACTION ITEM NO.

PROMPT ON-SITE NOTIFICATION NU BG R. M. Ragan 8-26-81 0830 hrs.

TITLE DATE TIME 3XX 81-53/03L-0 TITLE DATE T I..f E 24-HOUR NRC NOTIFICATION PRCMPT OFF-SITE NOTIFICATION TPH N/A F. A. Palmer 8-26-81 1555 hrs.

REGION II:

DATE TIME TITLE DATE TIME TGM N/A REGION lli & COL CATE TIME TI TL E DATE TIME RESPONSI ELE COMP ANY OFFI CER INFORMEO OF 10CFR21

/'

CONDITIONS AND THEL A DEPOPT TO NPC

'l((A. #TIIg

/

DATE

_ Mt 6i REV1 EW AND CcMPLETEb. o ni. NM~M/

8-25-81 CPERAT:NG ENGINttM DATE g

[

/

A CEP BY STATION REVIEW

!=

DATE l

RESOLUTICN APPPOVED AND AUTHORIZED FOR DISThlBUTION

(

V['T AT I ON

[

SUPERINTENDENT

'OATE 30 517 to-"

' 'O M 15-52-t) i t