Forwards IE Insp Rept 50-002/81-03 on 810727 & Notice of Violation
ML20010E241
Person / Time
Site: University of Michigan
Issue date: 08/21/1981
From: Spessard R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Kerr W
MICHIGAN, UNIV. OF, ANN ARBOR, MI
Shared Package
ML20010E242 List:
References
NUDOCS 8109030232
Download: ML20010E241 (2)


See also: IR 05000002/1981003

Text

-.

-.

-

._

-

..

.

,.

I

\\

4 o)

Docket No. Su-2

9'-

SE'r> 0219gI A 8

'

~

~

~

% g '88 k %

University of hichigan

,

ATTN:

Dr. William Kerr, Director

V

C

Michigan Memorial - Phoenix

//

Project

4

'

Phoenix Memorial Laboratory

N

Ann Arbor, MI 48105

Gentleman:

This refers to the special safety inspection conducted by Messrs. K. A. Ridgway

and R. C. Janke of this office on July 27, 1981, of activities authorized by

NRC Operating License No. R-28 and to the discussion of our findings with

Messrs. G. Cook and B. DuCamp at the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas examined during

the inspection. Within the e areas, the inspection consisted of a selective

examination of procedures and representative records, observations, and

interviews with personnel.

j

During this inspection, certain of your activities appeared to be in non-

compliance with NRC requirements, as described in the enclosed Appendix A.

i

!

The inspection showed that action had been taken to correct the identified

noncompliance and tc, prevent recurrence.

Consequently, no reply to this

'

noncompliance is required and we have no further questions regarding this

matter at this time.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of

this letter and the enclosed inspection report will be placed in the NRC's

(

Public Document Room.

If this report contains any information that you or

your contractors believe to be exempt from disclosure under 10 CFR 9.5(a)(4),

it is necessary that you (a) notify this office by telephone within seven (7)

days from the date of this letter of your intention to file a request for

withholding; and (b) submit within twenty-five (25) days from t!.e date of

this letter a written application to this office to withhold such infor-

l

18'

\\

{I

l

I

8109030232 810821

1

PDR ADOCK 05000002

G

PDR

- -

- - . . _ . .

.- -

.--

-

. - . - -

. - _ . - . - - . . - , - - _ . - _ _ . - - . . - - -

_

f

.

..

University of Michigan

-2-

'AUG 2 ! 19 91

mation.

Section 2.790(b)(1) requires that any such application must be

ac companied by an affidavit executed by the owner of the informatien which

identifies the document or part sought to be withheld, and which contains

a full statement of the reasons which are the bases for the claim that the

information should be withheld from public disclosure. This section further

requires the statement to address with specificity the considerations listed

in 10 CFR 2.790(b)(4).

The information sought to be withheld shall be

incorporated as far as possible into a separate part of the affidavit.

If

we do not hear from you in this regard within the specified periods noted

above, a copy of this letter and the enclosed inspection report will be

placed in the Eublic Document Room.

We will gladly diuuss any questions you have concerning this inspection.

Sincerely,

b

79 -3-) 6 e E

R. L. SpessIsrd, Director

Division of Resident and

Project Inspection

Enclosures:

1.

Appendix A, Notice

of Violation

l

2.

IE Inspection Report

'

No. 50-002/81-03