05000316/LER-1981-032-03, /03L-0:on 810712,operator Discovered Abnormally High Metal Temp on Turbine Driven Auxiliary Feed Pump Casing,Suction & Discharge Piping.Caused by One of Two Check Valves in Discharge Lines Not Sealing Completely

From kanterella
(Redirected from ML20010C851)
Jump to navigation Jump to search
/03L-0:on 810712,operator Discovered Abnormally High Metal Temp on Turbine Driven Auxiliary Feed Pump Casing,Suction & Discharge Piping.Caused by One of Two Check Valves in Discharge Lines Not Sealing Completely
ML20010C851
Person / Time
Site: Cook 
Issue date: 08/11/1981
From: Draper D
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20010C847 List:
References
LER-81-032-03L, LER-81-32-3L, NUDOCS 8108210104
Download: ML20010C851 (2)


LER-1981-032, /03L-0:on 810712,operator Discovered Abnormally High Metal Temp on Turbine Driven Auxiliary Feed Pump Casing,Suction & Discharge Piping.Caused by One of Two Check Valves in Discharge Lines Not Sealing Completely
Event date:
Report date:
3161981032R03 - NRC Website

text

E NRC FORM V6 U. S. NUCLEAR REGULATORY COMMISSION U in p

LICENSEE EVENT REPORT

_h CONTROL BLOCK: l l

l l

l l

l (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATIONI i

e Flil IM II ID IC IC 12 l@l 01 O! 0101010101010101 Ol@l 4111111111@l I

l@

F d 9 LICENSEE CODF 14 IS LICENCE NUMBLH 75 2n LICENSE TY"E 40 bl LAI $8 CON'T L(LLLI

%*"' I L j@l0 15 10 10 10 13 11.l6_J@l0 17 11 12 18 11 !@l 0 l C l 1 l 1 l 8 L1_j@

i 7

8 60 t> 1 DOCKET NUV8ER u

b'>

EVENT DATE 14 7,5 REPORT DATE 30 EVENT DESCRIPTION AND PHO8ABLE CONSEQUENCES O'o lo.12.] l WHILE UNIT TH0 WAS IN NORMAL OPERATION AT 90% POWER AN AUXILIARY EQUIPMENT OPERATOR l g ; ON A ROUTlNE PLANT TOUR DISC 0iERED ABNORMALLY HIGH METAL TEMPERATURE ON THE TURBINE l

,oi ;; DRIVEN AUXILIARY FEED PUMP CASING, SUCTION AND DISCHARGE PIPING. THE PUMP WAS HOT

,j AND HAD NOT BEEN RUNNING. THE STEAM SUPPLY VALVES TO THE TURBINE WERE CLOSED S0 THE l

, o,,, j i PUMP WOULD NOT RUN IN THIS CONDITION AND IT WAS DECLARED INOPERABLE AT 1128 AT WHICH i in ;c j l jo;,;l TIME THE ACTION STATEMENT OF T.S. 3.7.1.2 WAS IN EFFECT. THIS WAS THE FIRST l

OCCURRENCE OF THIS TYPE AND NO PROBABLE CONSEQUENCE RESULTED.

l Ses"

'!OJE J2&

Su'e C""o E sunT/ce cou,omN1 CODE 1o191 I C IH l@ LE_J@ LZ_J @ I V l A l l I V l E l X 18 LCJ@ LAJ @

l /

8 9

10 11 12 IJ

  • H l ')

10 g n pg E V E N T Y E' A n (EP HT O TY E N.

@,"(g.g 18Ill 1-1 10 13 12 I l/l 10 13 I LL_]

l-l [0_j

_ 11 21 23 74 26 27 28 29 30 31 32 d

A A

I N ON PL A T T4 HOUHS 22 S B IT D FO P B.

SL PLI f MAN FACTUREH [gj@[XJ@

lZl@

lZ[@

l0l0l0lul [Y j@

[N j@

lL l@

IAl51815l@

JJ J4 J's 36 J/

40 41 47 43 44 47 CAUSE DESCHIPTION AND CORRECTIVE ACTIONS 27 i,,q ; ONE OF Tha CHECK VALVES IN THE DISCHARGE LINES OF THE TURBINE DRIVEN AUXILIARY FEED-l

,,,,j ; WATER PUMP DID NOT SEAL COMPLETELY AND ALLOWED FEEDWATER FROM THE STEAM GENERATORS TO l FLOW BACK TO THE PUMP. DURING AN ATTEMPT TO DETERMINE WHICH VALVE WAS AT FAULT THE l

CONDITION RECTIFIED ITSELF. AFTER BEH!G ALLOWED TO C00LDOWN, THE PUMP WAS RUN AND j

g DECLARED OPERABLE AT 012S HOURS ON 7-13-81.

A REQUEST FOR CHANGE HAS BEEN INITIATED l

,,,,, i p

g a 80 51 s

% PO/iE R OTHEH STATUS is i

DISCOVERY DESCHIPTION I i l 5 I [_EJ@ l_0 l 9 l 0 l@l NA l

l Bl@l OPERATOR OBSERVATION l

i '

" Jn v.1v cOhNi HE LE ASEO OF HE LE ASE AYOUNT OF AC11VITy LOC ATION OF HEL E ASE li lo l L z] @ LLJ@l NA l

l NA l

" ' nosondoPOs&s orsen,PnON@

N u,w n ivn LLILJ l 0101 Ol@l Zi@l NA l

i n nsOwd',wun s otseniPnON6 Nomi n lilaILOI01ol@l NA I

r s 9 11 12 80 Y t ECi 10

[_Zj@l NA l

i o 8108210104 810811 issutS"@""INscHiPuoN @

PDR ADOCK 05000316 NRC USE ONLY S

PDR l

lllllllllllll7 LHj l

NA 2 o 7

H "

10 68 69 80 %

/

NAME OF PitEPAREn PHONE:

r

'5 '

D. C. COOK UtilT TWO DOCKET fl0. 50-316 SUPPLEf1EflT TO LER NO. 81-032/03L-0 CAUSE DES,CRIPTION AND CORRECTIVE ACTIONS TO GUARD AGAINST A FAILURE OF THE CHECK VALVES IN QUESTION.

RFC NUMBER IS 12-1861.

l k