05000368/LER-1981-024-03, /03L-0:on 810627,containment Pressure,Air Temp & Relative Humidity Were Outside Acceptable Tech Spec Stds. Caused by Main Chiller Tripping

From kanterella
(Redirected from ML20010C322)
Jump to navigation Jump to search
/03L-0:on 810627,containment Pressure,Air Temp & Relative Humidity Were Outside Acceptable Tech Spec Stds. Caused by Main Chiller Tripping
ML20010C322
Person / Time
Site: Arkansas Nuclear 
Issue date: 07/27/1981
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20010C319 List:
References
LER-81-024-03L, LER-81-24-3L, NUDOCS 8108190349
Download: ML20010C322 (1)


LER-1981-024, /03L-0:on 810627,containment Pressure,Air Temp & Relative Humidity Were Outside Acceptable Tech Spec Stds. Caused by Main Chiller Tripping
Event date:
Report date:
3681981024R03 - NRC Website

text

.

Nec r08tM 364 U. S. NU"LE AR REGULATORY COMMissaOag (F 77)

LICENSEE EVENT REPORT EXHIBIT A CONTRo, etoCx: l l 1 l I l l@

ieteAsc en NT on Tyre ALL atoutato NronMATiomt l Al R l A l Nj o l 21@i,l 0 l0 l -l0 l0 l 0l Oj 0 l-l 0 j0 jgl4 l1 l 1l1 l 1lgl l l

,, uf. g o i oo. coo.

m.,s....

n 2.

o n s.

,v,.

CON *T Q

O [1.j@!0 l 5 p 10101316 I 81@f o i 6121718111@l017121718111@

Go 68 ooCallTNuna01R 68 m

(vtNT OATE 24 75 ME,oRToATE 80 evtur cascairnow ANo esosAsts CoNscourNCcs @

l During Mode 3 operation, the combination of Containment pressure. average I o 2

- l air temperature, 6 relative humidity was determined to be outside the i

l region of acceptable operation as defined by T.S. Fj uure 3.6-1 on the 1

o.

o s i following dates: 6/27/81, 6/28/81, and 7/4/81.

Requirements of Action l

os I Statement T.S.

3.6.1.4 were met.

Thein hnvn been nn simi l nr necurren ces. I l Reportable per T.S. 6.9.1.9.b.

I o

lolol l I

es i

CC E suSC E LoM,0NENT COut mph a ut 5

oof 8,

,I A l Al@ [Ej@ [ A_j@ ll! IT l E l X I Cllil@ W@ W @

,2 2.

Li n.no EvtNTvtAR mt Y o E

h

@,53; 18111 L-J 1 01214 1 ld, 10131 LLJ l-1 t o_I

~

21 22 23 24 26 2

28 29 20 31 32 1

N ACT O T

MET HOURS

&S T o

,OR UIe L R MAN

,A Y ER [A_j@[2_J@ [JJ@

LZ j@

l 0101010 l [N_j@

[Nj@ [Aj@ l C l2 l 9l8 l@

33 34 JS 36 33 ao 48 42 43 44 4,

CAUSE DESCRIPTION ANo CORRECitVE ACTIONS h IContainment temperature increase was due to Main Chiller, 2VQi-1B, trip-r i o l ping, causing an elevated chilled water temperature supplying the con-i i

g Itainment coolers.

He "A" Main chiller was~ out of service for maintenancq.

g 1%e 6/27 trip was caused by a motor winding internal temperature sensor l

@ l failure, 6/28 trip by a control transformer failure, 6 7/4 trip by a clogt

',IDius, Ocre*boNetegl Problemkre14.sCoven,teg,to containment temperature increase o.scovin, o,sen.,no,. @

sr oo ia oTura sTafus (3o) o (fGj@ l Jl 0l Ol@l NA

! [Aj@l Operator Observation l

i s a gn,,,,,

g,,,,,

u o

a a

.. To,.cmnv @ l toc.,,0o,,,,u.3,@

.,u.s. o o,..u.s.

LIJ @ Iz_1 @ s u l

NA l

l NA i s

,,u.... d n,o.

onC.. T,o @

... so,,,,'

=

n,.

lo l 01 ol@[z_J@l NA l

i >

' ',,,,so. Nu','.u

=a on:. Tiv.@-

=uo.c.

101 0101@l NA l

i n n

u 1 (

of M 108, [J.j@l NA l

i o

,b,u,l@$[.','c.,,,,o @

~

Nac usc oNLv i

l NA 1 lllllll((l((I

> a niosi,oa, e,ohg~"ac Aaca Chris NJ Shively SN/968-2519

,ggy,;

{DRADOCK 05000368 PDR