Forwards Application for Withholding & Proprietary Rept WCAP-8687 Suppl 2,E22A.Also Forwards Revision 2 to Nonproprietary Rept WCAP-8587 Suppl 1,EQDP-ESE-22. Proprietary Rept Withheld (Ref 10CFR2.790)
ML20010A768
Person / Time
Site: Comanche Peak  
Issue date: 07/24/1981
From: Rahe E
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: John Miller
Office of Nuclear Reactor Regulation
Shared Package
ML19260J036 List:
References
NS-EPR-2481, NUDOCS 8108120199
Download: ML20010A768 (2)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _.. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

[m)

Westinghouse Water Reactor Nucley Techno!0gy Division Electric Corporation Divisions g.

Pittsburgh Pennsylvania 15230 NS-EPR-2481 July 24, 1981 cQt :m, N O

Y

  • 1\\ ]'

Mr. James R. Miller, Chief Special Projects Branch f,f.y B

Division of Project Management Nuclear Regulatory Commission Phillips Building g}G llNOIp l

Bet e a D

Dear Mr. Miller:

N q

Enclosed are:

1.

Fifteen (15) copias of a proprietary report WCAP,8687 Supplement 2, E22A entitled " Equipment Qualification Test Report Four Section Power Range Neutron Detector (Environmental and Seismic Testing)" (Proprietary).

2.

Twenty-five (25) copies of Revision 2 to iTAP-8587 Supplement 1 EQDP-ESE-22, " Equipment Qualification Data Package Four Section Power Range Neutron Detectors" (Non-Proprietary).

Also enclosed are:

1.

One (1) copy of Application for Withholding AW-81-19 (Non-Proprietary).

2.

One (1) copy of Affidavit (Non-Proprietary).

The enclosed information is being submitted in connection with the commitments made by Westinghouse in WCAP-8587, " Methodology for Qualifying Westinghouse WRD Supplied Safety Related Electrical Equipment." The generic qualification program described in WCAP-8587 is in accordance with Regulatory Guide 1.89 (IEEE 323-1974) and 1.100 (IEEE 344-1975).

It is referenced by a number of plants in Section 3.11 of the FSAa.

The enclosure contains copies of the completed proprietary and non-proprietary test reports describing environmental and seismic testing of the Four Section Power Range Neutron Detectors, gg(f gf%1 {t9pd A

J-p

, is h

QC.

1 ge@

SM l

$1 P i

0100120199 810724 k

PDR TOPRP ENVWEST C

PDR

  • This supplement contains proprietary information of Westinghouse Electric Corporation.

In conformance wit'. the requirements of 10CFR Section 2.790, as amended, of the Commission's regulatinr.s, we are enclosing with this submittal an application for withholding from public disclosure and an affidavit. The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission.

Correspondence with respect to the affidavit or application for withholding should reference AW-81-19 and should be addressed to R. A. Wiesemann, Manager of Regulatory and Legislative Affairs, Westinghouse Electric Corporation, P.O.

Box 355, Pittsburgh, Per.nsylvania 15230.

Very truly yours, M G -e m 7 s.

. P. Rahe, Manager 4

Nuclear Safety Department 9872A:1