t APPENDIX A NOTICE OF VIOLATION Georgia Power Company Docket Nos. 50-424 Vogtle 1 License Nos. CPPR-108 As a result of the inspection conducted on June 2-6, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7,1980), the following violation was identifiea.

10 CFR 50, Appendix B, Criterion V requires that activities affecting quality shall be prescribed by documented procedures and instructions and shall be accomolished in accordance with these procedures and instructions:

Procedure CD-T-02, " Concrete Quality Control", paragraph VI.E.7 requires the spacing of concrete vibrator insertions to be approximately 18 inches apart.

Contrary to the above, in the lower one-third of the concrete placement in pour number A-088-049, vibrator insertions were made through openings in the forms spaced three to five feet apart.

The size of the openings and congestion did not allow the yacing of concrete vibrator insertions to be made at the required 18-inch spacing.

This is a Severity Level V Violation (Supplement II.E).

Pursua'it to the provisions of 10 CFR 2.201, you are hereby required to submit to this office within thirty days of the date of this Notice, a written statement or explanation in reply, including: (1) admission or denial of the alleged viola-tion; (2) the reasons for the violation if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved. Consideration may be given to extending your response time for good cause shown. Under the authority of Section 182 of the Atomic Energy Act of 1954, as amended, this response shall be submitted under oath or affirmation.

Date: JU N 191981 W

8108110515 810731 3 PDR ADOCK 05000424 O

PDR