Proposed Tech Specs Table 3.5-1 Re Instruments Operating Conditions
ML20009H448
Person / Time
Site: Crane 
Issue date: 08/04/1981
From:
METROPOLITAN EDISON CO.
To:
Shared Package
ML20009H447 List:
References
NUDOCS 8108100125
Download: ML20009H448 (5)


Text

-.

-imm Os =

23 o in TABLE 3.5-1 RR

n u INSTRUMENTS OPERATING CONDITIONS oum o8 (A)

(B)

(C)

30$ -

Minimum Operable Minimum Degree Operator Action if Conditions Q &'

Functional Unit Channels of Redundancy of Column A Cannot be Met A.

Reactor Protection System 1.

Manual pushbutton 1

0 Maintain hot shutdown 2.

Power range instrument 3(a) 1(a)

Maintain hot shutdown channel 3.

Intermediate range 1

0 Maintain hot shutdown (b) instrument channels y

4.

. Source range instrument

.l' 0

Maintain hot shutdown (c) y channels 5.

Reactor coolant temperature 2

1 Maintain hot shutdown instrument channels 6.

Pressure-temperature 2

1 Maintain hot shutdown instrument channels 7.

Flux / imbalance / flow.

2 1

Maintain hot shutdown instrument channels 8.

Reactor coolant pressure a.

High reactor coolant 2

1 Maintain hot shutdown pressure instrument channels b.

Low reactor coolant 2

1' Maintain hot shutdown pressure instrunent channels

TABLE 3.5-1 -Continusd INSTRUMENTS OPERATING CONDITIONS (A)

-(B)

(C)

Minimum Operable Minimum Degree Operator Action if Conditions Functional Unit Channels of Redundancy of Column A Cannot be Met A.-

Reactor Protection System (con't.)

J9. ' Power / number of pumps 2

1 Maintain hot shutdown instrument channels

10. -High reactor building 2

1

. Maintain hot shutdown.

pressure channels (a) Forfchannel testing, calibration, or. maintenance, the minimum number of operable channels

.may be two and a degree of' redundancy of one for a maximum of four hours.

u (b).When.2 of 4 power range. instrument channels are greater than 10 percent full power,

.h.

hot shutdown is not required.

-10 (c) When 1 of 2 intermediate range instrument channels is greater than '10 amps, or 2 of 4 power range instrument channels are' greater than 10 percent full power, hot shutdown is not required.

B.

Other Reactor Trips 1.

. Loss of Feedwater 2(a) 1(a).

Maintain less than 7% indicated power 2.

Turbine Trip 2(b) 1(b)

Maintain less than 20% indicated power (a) Bypass of the:feedwater pump trip signal may be placed in effect when indicated reactor power is less than 7%.

The bypass will be removed when reactor power. is raised above 7%.

(b) The main turbine trip bypass may be placed in effect when indicated power is less than 20%.

.The bypass.will be removed when the reactor power is increased above 20%.

TABLE 3.5-1 Continued

-INSTRUMENTS OPERATING CONDITIONS Functional Unit.

(A)

(B)

(C)

Minimum Operable. Minimum Degree of_

Operator. Action if Conditions C.

Engineered Safety Features Analog Channels Redundancy of Column A and B Cannot be Met (a) 1.

Makeup and Purification System (high pressure injection mode) a.

Reactor Coolant Pressure 2

1 Hot Shutdown Instrument Channels b.

Reactor Building 4 psig 2

1 Hot Shutdown Instrument Channels c.- Manual Pushbutton.(b) 2 1

Ilot Shutdown u

2.-

Decay Heat System (low pressure injection mode),

a.

Reactor Coolant Pressure 2

1 Ilot Shutdown Instrument Channels b.

Reactor' Building 4 psig 2

1 Ilot Shutdown Instrument Channels c.

Reactor Coolant Pressure 1

0 Open circuit breaker D.H. Valve Interlock at MCC for Dil-V1 or Bistable-

' Dil-V2 with the affected valve in the closed position or. maintain R.C. pressure less than 350 psig.

my-

m LTABLE 3.5-1 Continued 9

INSTRUMENTS OPERATING CONDITIONS Functional' Unit (A)

(B)

(C)

Minimum Operable Minimum Degree of Operator Acti.)n if Conditions C..

Engineered Safety Features con't.

Analog Channels Redundancy of' Column A and B Cannot'be Met (a).

3.

Reactor Building Isolation

~

and Reactor Building Cooling System a.

Reactor Building 4 psig' 2

1 Hot Shutdown Instrument Channel

b. _ Manual Pushbutton 2

1 Hot Shutdown c.

RPS Trip 2

1 Hot Shutdown d.

Reactor Building 30 psig 2

1 Hot Shutdown Y~

RCS Pressure less than'1600 psig' 2 l'

Hot Shutdown e.

g.

4.

Reactor Building-Spray System a.

Reactor. Building 30 2(d) 1 Hot Shutdown psig Instrument Channel b.

Spray Pump Manual Switches (c) 2 1

Hot Shutdown 5.

.4.16KV ES Bus Undervoltage Relays a.

Degraded Grid Voltage Relays 2

1 (e)

.b.

Loss of Voltage Relay 2

1 (e) 6.

. Emergency Feedwater System Loss of Feedwater or RC Pump ~

2; 1

Hot Shutdown.

(all four) - Start Motor and Turbine-Pumps a

_.._,..,%i.

I L

TABLE 3.5-1 Continued INSTRUMENTS OPERATING CONDITIONS Functional Unit C.

Engineered Safety Features (con't.)

c (a) 'If minimum conditions are not met within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, the unit shall then be placed in a cold shutdown condition.

(b). Also initiatus Low Pressure injection.

1 (c)i. Spray valves opened by manual _ pushbutton listed in item 3 above.

{

(d) Two out of three switches in each actuation channel operable.

(e).If a relay fails in the untripped state, it shall be placed in a tripped state within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> to obtain a. degree of redundance of 1.

The relay may be removed from the trippend state for up to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> for. functional testing pursuant to Table 4.1-1.

Y