ML20009G289

From kanterella
Jump to navigation Jump to search
LER 81-055/03L-0:on 810617,drywell Hydrogen Recombiner 2T49-C001B Failed to Reach 600 F within 60 Minutes Per Tech Specs.Caused by Breaker Feeding Heating Coils in Off Position.Breaker Reset
ML20009G289
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 07/21/1981
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20009G285 List:
References
LER-81-055-03L-01, NUDOCS 8108040096
Download: ML20009G289 (2)


Text

7 77)

  • LICENSEE EVENT REPORT (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

CONTROL BLOCK: l I

l l l l l lh 6

0 lil8 l9 G l LICENSEE A l ECUDE lI lH l 2 l@l 010 l- 10 14 15 l0 l0 l010 l- l010 LICENSE NUMBER 25 l@l 4l 26 Il IlTYPE LICENSE Il ll@l JO l

57 CAT 58 l@

CON'T 0111 sO[RC, I L J@l 0 l 5 l 0 l 0 l 0 l 3 l 6 16 l@l 0 16 11 17 l8 11 74 l@l 75 0 REPORT l 71211DATE l 81180 l@

8 60 61 DOCKET NUMBER 68 69 EVENT OATE EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h o l 21 l With the reactor operatina at 2253 MWt. the devwell hydrocen recombiner. I O i3; i 2T49-C001B, failed to reach a temperature of 600U F within the 60 minutes l I O 141 l as required by Tech Specs 3.6.6.2. The plant was placed in a 30 day 1.C0 l 1

io isl l as a esult. There was no effect on public health and safety. This is I j O is i i a repetitive event as last reported on Reportable Occurrence Report No. 1

[Ojij i 50-366/1980-073. ]

l i O ls i l 80 7 8 9 C DE CODE S SC E COMPONENT CODE SUSC DE JU E lOI91 8

l S l E l @ [X_J@ l12 Z l @ l Z l Z l Z l Z l Z l Z l@ [Z_J 9 to 11 13 18 19

@ l20Zl @

SEQUENTI AL OCCURRENCE REPORT REVISION EVENT YEAR REPORT NO. CODE TYPE NO.

LER RO O reg yU

_ l218 22l 1l {_-.J 23 l 0151 Sl 24 26 W

27 10l3l 28 29 l Ll 30 l-l 31 l0l 32 AK N AC O ON PL NT ME HOURS S8 I FO At B. SUPPLIE MANUFACTURER lX 33 l@l34 Zl@ l35 Zl@ l36 Zl@ l0l0l0101 31 40 l Yl@

41 lNl@

42 lAl@ l0l3l4l4l@

43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 111011 Investiaations revealed the breaker feeding the heating coils was in the I 1

l i l i l I off oosition. The breaker was reset and the svstem returned to spevica- 1 l

iii2i l The cause for the breaker beina in the off oosition is not known. l.

1 I

tilail l

l1 14 I I

2NIS ST  % POWER OTHER STATUS IS O RY DISCOVERY DESCRIPTION 11 I s l M l Ol 9 l Ol@l NA l lBl@l Surveillance l A TIVITY CO TENT RELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE liIsl[Z_j@lZl@l 17 8 9 to 11 NA 44 l l 45 NA 80 l

PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION NA l l 117 l 10 l 0 l 0 l@l Z l@l PE RSONNE L INJURIES NUMBER DESCRIPTION NA l l i l a8 l9l 0 l 0 l 011l@l12 7 80 LOSS OF OR DAMAGE TO FACILITY TYPE D ESCRIPTION NA l l1 191 *

  • l Z l@l 8 PUBLI TY 8108040096 810721 NRC UsE ONLY ,

I iSSuEo DESCRIPTION h PDR ADOCK 05000366 12101 l N l@l S PDR NA l llllllllll lllj 1 8 9 to 68 69 80 5 W FnFpnFpAAFA R. T. Nix, Supt. of Maint. gnom 912-36_7-7781 2

LER No.: 50-366/1981-055 Licensee: Georgia Power Company Facility: Plant E. I. Hatch Docket No.: 50/366 Narrative Report for LER 50-366/1981-055 With the reactor in steady state operation at 2253 MWt, the drywell hy-drogen recombiner, 2T49-C001B, failed to reach 6000 F within the 60 minutes required by Tech Specs 3.6.6.2. The plant was placed in a 30 day LCO. There was no effect upon the health and safety of the public.

The power breaker to the heating coils was found in the off position.

There was no apparent reason for the breaker to be in the off position.

The breaker was reset and the system returned to service.

The generic review revealed no inherent problems with this event. This is a repetitive event as last reported on Reportable Occurrence Report No. 50-366/1980-073.

This report is being submitted at a time beyond 30 days of the discovery date due to personnel error. The monitoring system has been reviewed and the appropriate personnel counseled to prevent future occurrences of this type.

-. .- - -- . - - - . -