ML20009E425

From kanterella
Jump to navigation Jump to search
Proposed Temporary Change to Tech Spec 3.6.1.5,involving Revision to Containment Average Air Temp for Period of 120 Days,Effective 810723.Justification for Proposed Change Encl
ML20009E425
Person / Time
Site: Sequoyah 
Issue date: 07/23/1981
From:
TENNESSEE VALLEY AUTHORITY
To:
Shared Package
ML20009E421 List:
References
NUDOCS 8107280191
Download: ML20009E425 (2)


Text

.

ENCLOSURE 1 CONTAINMENT SYSTEMS AIR TEMPERATURE LIMITING CONDITION FOR OPERATION 3.6.1.5 Primary containment average air temperature shall be maintained:

a.pc-a.

between 85 F* and 110*F ir the containment upper compartment, and

.a.c b.

between 100 F* and 120 F in the containment lower compartment.

APPLICABILITY: MODES 1, 2, 3 and 4.

ACTION:

With the containment average air temperature not conforming to the above limits, restore the air temperatJ.e to within the limits within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE RE0CiREMENTS 4.6.1.5.1 The primary containment upper compartment average air temperature

f. :

shall be the weighted average ** of all ambient air temperature monitoring stations

(

located in the upper compartment.

As a minimum, temperature readings will be obtained at. least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> from the following locations:

Location a.

Elev. 743 ft.

b.

Elev. 786 ft.

c.

Elev. 786 or 845 ft.

4.6.1.5.2 The primary contair.nent lower compartment average air temperature shall be the weighted average ** of all ambient air temperature monitoring stations located in the lover compartment. As a minimum, temperature readings will be obtained at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> from the following locations:

Location a.

Elev. 722 ft.

b.

Elev. 700 ft.

c.

Elev. 685 or 703 ft.

Lower limit may be reduced to 60 F in MODES 2, 3 and 4.

    • The weighted average is the sum of each temperature multiplied by its respective containment volume fraction.

In the event of inoperable temperature sensor (s), the weighted average shall be taken as the reduced total divided by one minus the volume fraction represented by the sensor (s) out of service.

.e.

Mt upper //n/l E /,OS"F s', f4e uger c ris/a ssineitf ad s'ZS"F* k SEQUOYAH - UNIT [ UJ12LNmetri a ff (0erirriYW 'O/* tt /2 0 He /. n s-c 3/4 6-effec % e 7.,73'7

~

8107280191 810723 PDR ADOCK 05000327 P

PDR

s ENCLOSURE 2 JUSTIFICATION FOR PROPOSED CHANGE TO SEQUOYAH NUCLEAR PLANT UNIT 1 TECHNICAL SPECIFICATIONS The existing containment rir temperature upper limits are based on (1) FSAR chapter 15 emergency core cooling system (ECCS) analysis and (2) equipment protection and anticipated operating conditions.

In regard to item 1, Westinghouse Electric Corporation has reviewed the applicable analyses and concluded the following.

A.

The maximum predicted peak F for the duration of this cycle is 2.07 n

due to burndown of peaking fletors. Since the 10 CFR 50.46 loss of coolant accident (LOCA) analysis was done with a maximum F of g

2.237, the value of 2.07 for the remainder of the cycle ensures additional margin to the limit of 2,200 F in calculated peak clad temperature.

B.

The 10 CFR 50.46 ECCS performance analysis for Sequoyah Nuclear Plant unit 1 is based on a containment back pressure transient which assumes temperatures in the containment upper and lower compartments of 110 F and 120 F respectively.

In order for this analysis to be unaffected by an increase in either the upper or lower compartment temperature, the total containment air mass must remain unchanged. This can be accomplished by restricting the temperature in the unaffected compartment to offset the affected compartment's higher temperature.

For the specific case existing at Sequoyah unit 1 where a high temperature exists in the lower compartment, Westinghouse recommends a degree for degree trade off up to a maximum temperature limit of 125 F g

in the lower compartment. The effect of back pressure ou making this trade off is actually favorable since the upper compartment has a larger volume than the lower compartment, so the total air mass will g

increase. With a lower compartment temperature of 125 F, upper compartment temperature must not exceed 105 F.

In regard to item 2, considering that in containment equipment has been qualified to postaccident conditions, TVA believes that the integrity of such equipment would not be jeopardized due to this slightly elevated normal temperature.

In addition, TVA has determined that the average temperature for the areas in containment which contain equipment required to be qualified in NUREG-0588 is several degrees less than the overall containment average temperature. Both TVA and Westinghouse conclude that the slightly elevated temperatures in the lower ccmpartment will have negligible affect on equipment.