05000237/LER-1981-038-03, /03L-0:on 810609,vacuum Breaker Found Binding During Suppression Chamber to Drywell Vacuum Breaker Operability Test.Caused by Improper Clearance on Shaft Seals.Seals Adjusted

From kanterella
(Redirected from ML20009B945)
Jump to navigation Jump to search
/03L-0:on 810609,vacuum Breaker Found Binding During Suppression Chamber to Drywell Vacuum Breaker Operability Test.Caused by Improper Clearance on Shaft Seals.Seals Adjusted
ML20009B945
Person / Time
Site: Dresden 
Issue date: 07/07/1981
From: Zirwas K
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20009B941 List:
References
LER-81-038-03L, LER-81-38-3L, NUDOCS 8107200058
Download: ML20009B945 (2)


LER-1981-038, /03L-0:on 810609,vacuum Breaker Found Binding During Suppression Chamber to Drywell Vacuum Breaker Operability Test.Caused by Improper Clearance on Shaft Seals.Seals Adjusted
Event date:
Report date:
2371981038R03 - NRC Website

text

j IM 384,

.LLS. NUCLEAR REGULATORY COMMISS!!N _ _.

LICENSEE EVENT REPORT CONTMOL BLOCK: l l

l l

l l

lh (PLEASE PRINT OR TYPF ?

  • 1. REQUIRED INFORMATION) 1 6

l Il Ll Dl Rl Sl 2 l@( 0 l 0 l - 10 l 0 l 0 l0 10 l-l 0 l 0 l@l 4 l 1 l 1 ! 1 l 1 l@lsi CAT s, @

l l

9 uCENsEE Coce i4 s

uCENsE NumeEs 25 2e uCENsE TvPE 40 Mu',%lL l@l 0l 5101010 l 21317 @l 0! 6l 0 l 9 l 8 l 1 l@l 0 l 7 l 0 l 7 l 8 l1 l@

60 61 QQCKET NUMBER 68 69 EVENT DATE 74 s

REPORT DATE SO EVENT DESCRIPTION AND PROBABLE CONSECUENCES h

- l Durine s,m m esi~, chamber to drvweil vacuum breaker coerability test < DOS 1600 0 I
l vacuum breaker 2-1601-32C was found binding.

It was chained closed oer T.S.

3.7.A.4.bj

,l Public health and safety was not jeopardized since 2-1601-32C was closed prior to l

l surveillance, and 11 of the 12 vacuum breakers were still Operable (9 required). Last l l previous event:

R.O. 50-237/79-64.

l ll I

I

,I 80 9

0E OE SL C E COMPONENT CODE SUS ODE SU 00E l Sj Al@ lE l@ l5 l@ l V l Al L lV lE lX l@ l Cl@ l Cl@

l 9

to 11 12 13 18 19 20 SEQUENTtAL OCCURRENCE REPORT REVISION EVENT YEAR REPORT NO.

CODE TYPE N O.

l @ lLER/RO l218 l1 l l-l l 013l 8l lA 10 l 3 l ltl l-l l0l

,gg 22 23 24 25 27 28 29 30 31 32 N

O P T

MET WOURS S8 POR 8.

E MANUP RER _

i l E l@l Z l@

l2l@

l Zl@

l 0l 0l 0l 0l lNl@

lY l@

lNl@

l A l 5 l 8 l 5 l@-

as u

3s 36 27 40 4

42 43 44 47-CAUSE DESCRIPTION AND CORRECTIVE ACTICNS h l The cause of the binding was imoroper clearance on the shaft seals. The seals were I

l adjusted and tested satisfactorilv. DOS-1600-9 will continue to be run monthlv.

I I

I I

I I

f 80

,9

'.k

% POWER OTHERSTATUS Ot RY DISCOVERY CESCRIPTION llE l@ l 0 l 4 l 5 l@l N/A l

lBl@l Routine Surveillance I

t 12 is 44 de as a0 g

eg y AMOUNT CF ACTIVITY LOCATION OP RELEAJE a.EASEo@OF RELEASE lZl@l N/A l

l N/A l

ll9Zl 10 11 44 46 80 i

PEASONNEL EXPOSURES CESCRIPTTON NUM8EA TYPE @l l

N/A l

ll010l0l@lZ 2

,eRSON~.Nu'Ri ES l

Nuussa OESCRiPTicN j

l ll0l0l0l@l N/A 80 I9 11 12 l LCSS OF On OAMAGE To FACIUTY 43

' TYTE @lDESCRi> TION lZ l N/A l__

PususTY 8107200058 810708 NRC USE ONLY 45 PDR ADOCK 05000237 t

l 1SSgo@lOESCRIPTtON PDR l

III!IIIIIIIIII l

l N/A S

I 68 69 80 5 9

10 l~

K. Zirvas 942-2920 Ext. 422 0

1 i

AwnN S-l

?JAME CF PAPP ARC A

b-2)

DEVIATION REPORT s

~

y DVR NO.

1 Commonwealth Edison STA UNif YEAR N O.

D 2 62 OCCU RRED past il TI TLE OF DEVI ATION A/9/81 1-047e

- TIJ' t'~

Tscuum Breaker 1601-32C Binding T E511NG SYSTEM AFFECTED 1600

PLANT CONDITIONS

C Primary Containment Run 1150.6 318.9 MODE PwR(vwT)

, LOAD (MWE)

YES NO DESCPIPTION OF EVENT DOS 1600-9, vacuum breaker i

suopression chamber to drvrell vacuum breaker -perability test u 2g _ ng

2-1601-32C was binding. Checked shaft seals, grrased, no change.

DESCRIPTION OF CAUSE

. Unknown 6~THER APPLICABLE INFORMATION

~

Vacuum breaker chained closed.

EQUlrMENT C YES DR NO.

WR NO.

R. Weidner 6/9/81 FAILU RE C NO N/A 14115 eEspONsiste suprevisOR OATE PART 2 l OPERATING ENGINEERS CCMMENTS Tha remaining vacuum breakers were operable. The vacuum breaker will be repaired during the ntxt unit outage.

SAFETY-TYPE OF CEVIATION EVENT OF POTENTIAL TECH SPEC NON-REPCRTABLE ANNUAL RELATED REPORTABLE CCCURRENCE PUBLIC INTEREST VICLATION CCCURRENCE REPCRTING WR ISSUED YES ]

YES 10CFR2f 14 DAY NO NO AT' N 30 CAY NO{I FI REPORTABLE CCCURRENCE ACTION ITEM NO.

PROMPT ON-SI TE NOTI FI CATION 6/15/81 0930 NUMBER R. M. Ragan j

TITLE DATE TIME

'eot 81-38/03L-0 TITLE CATE TIME 24-HOUR NRC NOTIFICATION (Courtesy)

PROMPT OFF-SITE NOTIFICATION b

TPH Mike Jordan 6/9/81 S 1200 hrs F. A. Palmer 6/15/81 11:38 REGION lil CATE TIME TITLE DATE TIME L

TGM REGION lli & COL-CATE TIME TITLE CATE TIME RESPONSI BLE COMP ANY OFFI CER INFORMED OF 10CFR21 JATE IsMt TITLE CONDIT'ONS AND THEIA DEDO AT TO N PC

. John Wuici22 6/12/81 REVI EW AND COMPLETED OPER AT !NG ENG NEtH DATE CP BY STATION REVIEW gg gg{

7 I

7'7'UA DATE

/724-4,

RESOLUTION APPROVED AND AUTHORI ZED FOR DI STRI BUTION

/ITATION SUP INTENCENT CATE 86*S17' t0*??

( FO Res 15**2**)

I I