05000318/LER-1981-027-03, /03L-0:on 810602,during Surveillance Testing,Hpsi Pump 23 Failed to Start.Caused by Failure of Control Time Delay Relay.Relay Replaced

From kanterella
(Redirected from ML20009A691)
Jump to navigation Jump to search
/03L-0:on 810602,during Surveillance Testing,Hpsi Pump 23 Failed to Start.Caused by Failure of Control Time Delay Relay.Relay Replaced
ML20009A691
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 07/02/1981
From: Junge M, Rizzo P
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20009A689 List:
References
LER-81-027-03L, LER-81-27-3L, NUDOCS 8107130477
Download: ML20009A691 (1)


LER-1981-027, /03L-0:on 810602,during Surveillance Testing,Hpsi Pump 23 Failed to Start.Caused by Failure of Control Time Delay Relay.Relay Replaced
Event date:
Report date:
3181981027R03 - NRC Website

text

f NRC FORM 366 50 M M OC'TN N (7 7W

~~

LICENSEE EVENT REPORT CONTRCL BLOCK:

l l

l l

l (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 10 l 1 l l Ml Dl Cl Cl Nl 2 l@l 0 l 0 l -l 0 l 0 l 0 l 0 l 0 l - l 0 l 0 l@l 4 l 1 l 1 l 1 l 1 l@l l l@

8 9 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE JO 57 CAT 58 CON'T SYRSlLl@l0lSl0l0l0l3l118J@l01610l2l811l@l0l7l012l8l1 l@

IOI1I 7

8 60 61 DOCKET NUM8ER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h 10121 l At 1800 during surveillance testina. #23 HPSI Pumo failed to start on e I

iO iai l SIAS "B-2", but pump did start satisfactorily from the Control Room I

1014 I I (T.S. 3.5.2a). #21 HPSI Pump remained operable during this event. A I

FOTs1 I relay was replaced, #23 HPSI Pump was tested and returned to service at I

iO is i I 0030 on 06-03-81. No similar events have been reported.

l l 017 l l l

I 101811

^

CODE CODE SU8 CODE COMPONENT CODE SU8C dE S

E 8

lE IB l@ l E l@ l A l@ l R l E l L l A l Y l X l@ l Hi@ LZ_; @

7 8

9 10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT F EVISION LER EV ENT YE AR REPORT NO.

CODE TYPE NO.

@,ag/RO 1811]

l--J l01217l l/l 10 l3 l lLl l-l 10 l

_ 21 22 23 24 26 27 28 29 30 1

32 K N AC Of ON PL NT ET HOURS 22 SB i FOR 5 8.

SUPP IE MANUF CTURER ICl@lZf@

lZl@

lZl@

l0 l0 l0 lu l lN l@

l Yl@

l Al@

l A l1 l019 l@

33 J4 35 36 37 40 41 4,

43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h 1 1011

  1. 23 HPSI Pumo Motor Breaker would not close due to the failure of con-I li lii I trol time delay relay 2/SB2 ( Aaastat #7012PB).

The relay's normally noen I

i, i2i i contact would not close, and it was reolaced with a like snare. Because I

mI this has not been a repetitive event. no oreventive action is deemed I

ii14i l necessary.

I 7

8 9 80 ST S

% POWER OTHER STATUS dis O RY DISCOVERY DESORIPTION

[_Ej@ l 110 l 0 l@l NA l

l B l@l Surveillance Testina l

i s A TP,lTY CO Tern ret 2ASED Cr RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE W LZj @ [Z_j@l NA l

l NA l

7 8 9 10 11 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE

DESCRIPTION

I1171 l O! 0l 0l@l Zl@l NA l

PERSONNELIN.U IES NUMBER

DESCRIPTION

y l0l0l0l@l NA l

7 8 9 11 12 80 TY E DESCR P ON J @l NA l

I 9 PUBLl$TY 8107130477 810702 NRC USE ONLY i 3UED DESCmPTION DR ADOCK 05000318 ITITl :[ Njhl NA FDR

] lllllllllIIll%1 3

7 8 9 10 68 69 80 g NAME OF PREPARER PHONE: