ML20009A689

From kanterella
Jump to navigation Jump to search
Forwards LER 81-027/03L-0
Date released: 01/23/2020 Download: ML20009A689


LER 81-027/03L-0:on 810602,during Surveillance Testing,Hpsi Pump 23 Failed to Start.Caused by Failure of Control Time Delay Relay.Relay Replaced
ML20009A691
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 07/02/1981
From: Junge M, Rizzo P
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20009A691 (1)
Forwards LER 81-027/03L-0
ML20009A688
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 07/02/1981
From: Russell L
BALTIMORE GAS & ELECTRIC CO.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20009A688 (1)