Containment Leakage Rate Testing,Zion Units 1 & 2, Technical Evaluation Rept
ML20008G041
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 06/08/1981
From: Delgaizo T, Kaucher J
Franklin Research Ctr, Franklin Institute
To: Huang Y
Office of Nuclear Reactor Regulation
Shared Package
ML20008G042 List:
References
CON-NRC-03-79-118, CON-NRC-3-79-118, TAC 08862, TAC 08863 TER-C5257-057-5, TER-C5257-057-58, TER-C5257-57, TER-C5257-57-5, TER-C5257-57-58, NUDOCS 8106110449
Download: ML20008G041 (16)


Text

TECHNICAL EVALUATION REPORT I CONTAINMENT LEAKAGE RATE TESTI.NG COMMON'dEALTH EDISON COMPANY '

ZION STATION UNITS 1 AND 2 NRC DOCKET NO. 50-295/304 N RC TAC NO. 08862/08863 FRC PROJECT C5257 NRC CONTRACT NO. NRC43-79-118 FRC TASKS 57, 58 Prepared by Franklin Research Center Author: J. E. Kaucher T. J. DelGaizo The Parkway at Twentieth Street Philadelphia, PA 19103 FRC Group Leader:

T. J. DelCaizo Prepared for l

Nuclear Regulatory Commission Washington, D.C. 20555 Lead NRC Engineer:

Y. S. Huang.

l June 8, 1981 l

This report was prepared as an account of work sponsored by an l

agency of the United States Government. Neither the United States I

Government nor any agency thereof, or any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for any third party's use, or the results of such use, of any information, apparatus, product or process disclosed in this report, or represents that its use by such third party would not infringe privately owned rights.

d Franklin Research Center A Division of The Franklin Institute

/-

  • * " " ~ ' " " * " ' ' " " " ~ ' ' " " ' " ' " * *

?IoClIbW{u m

TER-C5257-57/58 CONTENTS Section Title Page 1

Bl.CKGROUND 1

2 EJALUATION CRITERIA 2

3 TECHNICAL EVALUATION 3

3.1 Request For Exemption Frem the Requirements of Appendix J 3

3.1.1 Exemption From the Required Sequence of Conducting Type A and Type C Tests 3

3.1.2 Exemption Frem the Required Pressure for Testing Containment Airlocks 4

3.1.3 Exemption Frem Type C Testing Requirements for the Component Cooling Water Return valve 5

3.1.4 Exemption From Type C Testing Requirements for the Nitrogen Line Valves to the Pressurizer Relief Tank 7

3.1.5 Exemption Frem Type C Testing Requirements for the Nitrogen Line Valve to the Safety Injection Accumulators 9

3.1.6 Exe:ption Frem Type C Testing Pequirements for the Fire Protection Header Containment l

Isolation valve.

11 3.1.7 Exemption From Type C Testing Pequirements for the Residual Heat Remcval System Suction Line valves 12 14 4

CONCLUSIONS 5

REFERENCES 15 l

O iii 0000 Franklin cessarch Center Am umvo m 9

e k

TER-C5257-57/58 Cu N-1.

BACKGROUND On August 5, 1975 [1], the NRC request.ed Commonwealth Edison Company (CWE) to review the containment leakage testing program for Zion Station Units 1 and 2 (Zion 1 and 2) and to provide a plan for achieving full compliance with 10CFR50, Appendix J, including appropriate design modifications, changes to technical specifications, or requests for exemption from.the requirements pursuant to 10CFR50.12, where necessary.

CWE responded to the NRC's request in a letter dated September-26, 1975

.e

[2], in which two requests for exemption from the require $ents of Appendix J were listed for Zion 1 and 2.

The NRC, in a letter dated November 23, 1976

[3], asked CWE several questions regarding this submittal..

In a letter dated January 31, 1977 [4], CWE replied to the questions in Reference 3 and also provided a preposed method of monitoring for airlock seal 4

leakage using the penetration pressuri::ation system.

on May.11,*1977.['5],'CWE requested additional exemptinns that would omit i

six valves from the Type C testing requirements of Appendix J, and on July 7, 1980 [6], CWE for.<arded additional information in support of previously submitted requests.

The purpose of this report is.to provide technical evaluations c,f the l

outstanding submittals regarding the implementation of the requirements of i

10CFR50, Appendix J at Zion 1 and 2.

Consequently, technical evaluations of the exemption requests submitted in References 2 and 5 are provided.

l-I A

i l

l q

+

LCDUr.nu2inaes..,chcente, A Osassen af N Frannha kwamme h

~ _

)*

s

' t.

\\

.~

TER-CS257-57/58 p

s

2. - EVALUATION CRITERIA 7.

Coder Af Fedecal Regulations, 'Tih.le 10, Part 59 (10CFR50), Appendix J,_

j Conte,inraent Leakage Tecting, was specified by the NRC as containing the cri-teria for the eyeluations. Where applied to the evaluations in this report, the criteria are either referenced or briefly stated,'where necessary, in

~

support of the determinationr.

Furthermore; in recognition of plant-specific conditions that could lesd to requests for exesption. not explicitly covered by

~

the regulations,Tche NRC directed that the technical review constantly cephasize the intent of Appendix d, that potent.ial containment atmospheric

' leakage paths be identified, monitored, and maintained below established limits.

,s

(

/-

4

  • ._ l a

1 y

i ~

~

r

\\

\\

r s

I A

e 8

T

\\ -

o i.

f' 1

i 1

4,

2-hd Frank 5n Research Center A:>.s.anarne p n n me 1

I TER-CS257-57/58 3.

TECHNICAL EVALUATION 3.1 REQUESTS IVR EXEMPTION FROM THE REQUIAEMENTS OF APPENDIX J 3.1.1 Eyeeption Prem the Recuired Sequence of Conductino Tvpe A and Type C Test Section III. A.l(a) of Appendix J requires that the Type A test be per-formed as close to the "as is" condition as practical. 'When excessive leakage paths are 18entified during the Type A test, Appendix J requires the test to bc1 terminated and leakage through such paths to be measured by local leakage rate piccedures.

After repairs,or adjustments are zacer a subsequent Type A test is performed. The corrective action taken, change in leak rate deter-mined from the tests, and the overall integrated leakage determined from the local and Type A tests are reported to the NRC.

s In Reference 2, 'OT stated its view concerning this requirement as follows:

Our plan has been *.o conduct local leak rate tests during the first part,of anicutage. We then conduct an integrated leak rate test close to tLe end of the outage. The results of the integrated leak rate test are then corrected back to determine conditions that existed at the bigin'nin_g of the cutage using local leak rate test results.

In, Reference 3,.the NRC indicated to CNE that this procedure would be accept-able provided ti:at in back-correcting the results of the integratad test, a consrervative assumption is applied that the measured, local leakage rate is in a di:ection out of the containment.

In Reference 4, CWE agreed that all local

' leak rate t'ests would be conducted using the. conservative assumption that the 2 - total reasured local leakage rate is in a direction out of the containment.

Etaluation The intent of Sectio n III.A.l(a) is to ensure that the containment is tested as close to an "as is" condition as possible. The "as is' condition is significant la determining the required frequency of future Type A testing.

j/

Wherec).cessivecleakageisdetectedandccerectedbylocaltestingprocedures n"

prior to performing the Type A test, the "as is" condition is icst, and the nk!!n Researth Center A Onewaf The Fmmhn huamar

.~ _-

=. _ _

._ =.

TER-C5257-57/58 subsequent Type A testing irequency may be inadvisably extended based upon unjustified confidence in past containment perfort:ance. However, w.ith the conservative assumption that all local leakage is in a direction out of the containment when back-correcting the results of a Type A test, the.

back-corrected results will actually be conservative relative to measured leakage from a Type A test performed prior to the local tes*.ing.

This is a

because a large amount of measured local leakage may not be actual out-leakage Consequently, there is no possibility of an inappropriate extension of Type A testing frequency where this conservative procedure is used.

In view of the above discussion, CWE's propcsal to conduct local leakage rate tests prior to the Type A test and to back-correct the results using the conservative assumption that all measured local leakage is in a direction out of the containment is an acceptable exemption to the requirements of Section i

III. A.l(a).

4

  • 3.1. 2 Fxereption From the Required Pressure for Testing Containment Airlocks - -

In keference 2, CWE requested an exemption from Type B testing require-ments of Appendix J to permit airlock door seal testing at reduced pressure (3 psig) using the penetration pressurization system in lieu of testing at peak calculated containment pressure (Pa) for cirlocks which are cpened during the 6-month interval between required tests. CWE stated that the airlock door seals are continuously pressurized to 3 psig and monitored for leakage through the penetration pressurization system. CWE further indicated that the existing high flow alarm was not sensitive enough to provide indication of door seal failure before exceeding the technical specification limit on allowable leakage. CWE stated that a ::calification would be completed to install a flowmeter with a high flow alarm which would be suf ficiently sensitive to detect a high leakage condition on the seal.s well before reaching the technical specification limit.

In Reference 6, this mcdification was reported to have been completed.

In Reference 4, CWE described its method of extrapolating seal testing at reduced pressure to full pressure test results. CWE prcposed to use the ON Ohhd Franklin Research Center A bes.en of The Frenska Irummens

,,___---~-y:

~. -,

TER-C5257-57/58 formula provided in the paper " Conversion of Leak Flow-Rates fer Various Fluids and Different Pressure Conditions," by J. Arrest [7] :

2_1 i

Li P1 L2 P2

~1 where Li = leakage rate at pressure P1 (SCFH)

L2 = leakage rate at pressure P2 (SCFH)

P1 = pressure in areas where leakage rate is L1 (atmospheres)

P2 = pressure in areas where leakage rate is L2 (at=ospheres).

Evaluation The requirements for periodic testing of centainment airlecks are set forth in Sections III.B.2 and III.D.2 of Appendix J.

Section III.D.2 was recently revised by the NRC, effective October 22, 1920. Subparagraph [b][lii) of the revised Section III.D.2 reads as follows:

Airlocks opened during perieds when containc.ent integrity is required by plant's Technical Specifications shall be tested within 3 days after being cpened. For airlock doors opened =cre frequently than once every 3 days, the airlock shall be tested at least once every 3 days during the period of frequent cpenings.

For airlock doors having testable seals, testing the seals fulfills the 3-day test require =ents.

In the event that the testing for this 3-day interval cannot be at Pa, the test pressure shall be as stated in the Technical Specifications. Air-lock door seal testing shall not be substituted for the 6 -cath test of the entire airlock at not less than Pa.

Since this revision provides for reduced pressure testing of airlock door seals, CWE's requtst for exemption f rc:n the requirenents of Appendix J is to longer necessary. CWE should ensure that its airlock testing program is in accordance with all the requirements of the revised Appendix J.

FRC has also reviewed CWE's method of extrapolating the results of air-lock testing at 3 psig to Pa (47 psig) provided in Refererne 4.

This extrapolation provides a conservative correlation between leakage rate at low pressure and full pressure leakage rate and is therefore acceptable.

. 4 Wbdtan'rEn Research Center A b ef The Frannet vessime

TER-C5257-57/50 3.1.3 Exemption From Type C Testing Requirements for the Component Cooling Water Return Valve In Reference 5, CWE requested an exemption from the Type C testing requirements of Appendix J for the coeponent cooling water return line valve (AOV-CC9437) from the excess letdown heat exchanger. CWE's basis for this request is that this valve is a normally closed valve located in a closed system inside containment which does not communicate directly with the reactor coolant system pressure boundary or the containment atmosphere.

In Reference

?

6, CWE stated:

l This centsinment isolation valve on the component cooling water return line from the excess letdown heat exchanger isolates a closed system within the containment. The closed system does not communicate directly with the reactor coolant system (RCS) pressure boundary or the containment atmosphere. A portion of the system piping and equipment is inside the missile barrier and a portion is outside the missile barrier. The cutside portion is missile protected by the barrier and I

the inside portien is also shielded from missiles because of its i

enclosure within concrete walls as can be seen on the attached i

drawings, M-12e and M-137.

As indicated in Reference (c), the component cooling water system pressure of 100 psig is well above the containment post accident peak pressure of 47 psig, and thus any leakage past valve A0v-CC9437 and a ruptured cesponent cooling line wou'd be into the containment and not out.

Therefore, no safety A

implications are involved. Since the valvt is normally in the closed position, no provisions for leak testing are provided, nor required for the above reasons.

Evaluation l

Section II.H of Appendix J requires Type C testing o;' a normally shut valve such as Ac7-CC9437 when it can provide a direct connection between i

inside and outside containment atmosphere.Section III.Ael.(d) of Appendix J requires Type C testing of this valve if the component ' cooling water system communicates directly with the reactor coolant system or if the component cooling water system ruptures as a result of a loss-of-coolant accident (LOCA).

i The component cooling water system inside containment is a closed system inside containment which does not communicate directly with either the reactor coolant system or the containment atmosphere. The heat exchanger is a Seismic i

A Obd Frank:in Research Center j

A Chuusenef The Fmuen Insense l

1 i

TER-C5257-57/58 The closed sy' tem is protected from internally Category I component.

s generated LOCA missiles by either the missile barrier or other concrete walls. Consequently, this system is not liable to rupture as a result of a LOCA.

The component cooling piping inside containment services no essential 4

post-accident loads; therefore, this piping is automatically isolated from the j

system at the start of the accident. Even if this piping were to rupture during the post-accident period (e.g., due to an intervening seismic event),

the containment penetration would be water scaled by the component cooling system outside containment, which is designed to continue servicing vital loads outside containment. The water seal is sufficient to remain effective I

throughout the post-accident period since there are ample safeguards to ensure that the system's water inventory is maintained throughout the entire period.

This is provided by two surge tanks (each of 2000 gallons), which are each capable of being refilled, if necessary, from two independent sources - the primary water sys9em mod the demineralized water system.

Consequently, valve A0V-CC9437 need not be Type C tested because it isolates a closed system that is not likely to rupture after an accident, and even in the event of a rupture, it is not relied upon to prevent atmospheric leakage because of a water seal by the operating cooling system. No exemption from the requirements of Appendix J 13 necessary because testing of this valve is not required by Appendix J.

i I

3.1.4 Exemptien From Type C Testing Requirements for the Nitrogen Line Valves to the Pressurizer Relief Tank (PRT)

In Reference 5, CWE requested exemption from the Type C testing require-ments of Appendix J for valve ACV-RC8733, the nitrogen supply line isolation f

valve to the pressurizer relief tank. CWE's basis for this request is that the valve isolates a closed system within containment. CWE stated that the system does not communicate directly with the RCS pressure -boundary, since the pressurizer safety and relief valves constitute the RCS pressure boundary as demonstrated by the system design classification change downstream of these

)

1% Mil Franklin Research Center 4 b af The framedwiinsomme

- - - :.L

._..:.:=..--._.L..-_,.,

e TER-CS257-57/58 valves, nor does it communicate directly with the containment atmosphere. The system piping and equipment are located outside the missile barrier and are therefore missile protected. The nitrogen system pressure of 100 psig on the line to the PRT is well above the pcst-accident containment peak prassure of 47 psig; thus, any leakage past valve ACV-RC8033 would be into the containment and not out.

Therefore, CWE stated that no safety implications are involved, and since the valve is normally closed, no provisions for leak testing are provided or required.

Evaluation Section II.B of Appendix J requires Type C testing of a normally shut valve such as ACV-EC8803 when it can provide a direct connection between inside and outside containment atmospheres.Section III.A.1(d) of Appendix J requires Type C testing of this valve if the nitrogen system communicates directly with the reactor coolant pressure boundary or the containment atmosphere or ruptures as a result of a LOCA.

CWE's basis for the exemption request is that the nitrogen line to the pressurizer relief tank (PRT) does not communicate directly with the reactor coolant system or the containment atmosphere, does not rupture as a result of.

LOCA, and therefore does not provide a direct connection between inside and outside containment atmospheres. CWE also maintains that any leakage through this penetration wil3 be into containment because of the 100-psig nitrogen source outside of the containment.

The 100-psig nitrogen source cannot be relied upon to perform a post-accident sealing function, however, since it is not safety-related or designed *to other higher reliability standards.

In a post-accident condition, this source must be considered unavailable. Also, this line cannot be con-cidered to be a closed system inside containment since it is connected to the pressurizer relief tank. Operation of either the pressurizer relief / safety valves or the tank rupture disc connect ~ this line directly to the reactor coolant system or the containment atmosphere, respectively. While for N

ranklin Research Center A theen af The herahn kwamme

TER-C5257-57/58 t

certain accident scenarios this line will be part of a closed system, it does not follow that it will always be a closed system under accident conditions.

Finally, with regard to the contention that the system does not rupture after an accident, FRC concurs that the line is not likely to rupture since it is protected from LOCA missiles.

It should be noted, however, that ANSI N271-1976 requires a closed system inside containment to be designed to Seismic Category I standat in order to take credit for the piping system as an isolation boundary. While ANSI N271-1976 addreases containment isolation provisions, the concept is similar. The nitrogen line to the PRT is not a Seismic Category I line and therefore its integrity through'out the post-accident period is not guaranteed.

~

Taken altogether (non-safety-related nitrogen source, direct connection to the FRT, and non-seismic design), there is insufficient justification for concluding that this line will not be a source of pctential containment atmospheric leakage throughcut the post-accident period. Consequently, an exemption in this case is inappropriate and valve ACV-RC8803 should be tested in accordance with Section III.A.l. (d) of Appendix J.

3.1.5 Exemption Frem Type C Test-ine Recuirements for the Nitrocen Line Valve to the Safety Injection Accumulators In Reference 5, CWE requested an exemption from the Type C testing requirements of Appendix J for Valve ACV-SI8880, the isolation valve in the nitregen line to the safety injection accumulators.

CWE's basis for this request is that the valve isolates a closed system inside containment. The closed system does not communicate directly with the RCS pressure boundary, since the accumulator discharge line check valves constitute the RCS pressure boundary as demonstrated by the system design classification change downstream of these valves, nor does it comrunicate directly with the containment atmo-sphere.

The system piping and equipment are located outside the missile bar-rier and are therefore missile protected. The nitrogen system pressure of 600 psig in the line to the accumulators is well above the post-accident contain-ment pressure of 47 psig, and thus, any leakage past valve ACV-SI8880 would be t

_4. _ _

~

TER-C5257-57/58 into the containment and not out. CWE stated that no safety implications are involved, and since the valve is normally closed, no previsions for lesh testing are provided or required.

Evaluation Section II.H of Appendix J requires Type C testing of a normally shut valve such as ADV-RC8880 when it can provide a direct connection be' tween inside and outside containment atmospheres.Section III. A.l(d) of Appendix J requires Type C testing of this valve if the nitrogen system communicates directly with the reactor coolant pressure boundary or the containment atmosphere or ruptures as a result of a LOCA.

CWE's basis for the exemption request is that the nitrogen line to the safety injection accumulators does not communicate directly with the reactor coolant system or the containment atmosphere, does not rupture as a result of a

LOCA, and therefore does not provide a direct connection between inside and outside containment atmospheres. CWE also maintains that any leakage through.

this penetration will be into the containment because of the nitrogen source outside of the containment.

The nitrogen source cannot be relied upon to perform a post-accident sealing function, however, since it is 'not safety-related or designed to other higher reliability standards.

In a post-accident condition, this source must be considered unavailable. Also, this line cannot be considered to be a closed system inside containment since it is directly connected to the safety injection accumlators which are directly connected to the reactor coolant piping. The fact that there are two check valves in each line from the accumulators to the reactor coolant piping (which are not periodically pneumatically leak tested) is not a sufficient basis for establishing the nitrogen system as a closed system inside containment.

Finally, with regard to the contention that the system does not rupture after an accident, FRC concurs that the line is not likely to rupture since it is protected from LOCA missiles.

It should be noted, however, that ANSI ObFran; din Resecrch Center

%.m. r- -

TER-C3257-57/58 N271-1976 requires a closed system inside containment to be cesigned to Seismic Category I standards in order to take credit for the piping system as an isolation bcundary. While ANSI N271-1976 addresses containment isolation

~

provisions, the cencept is similar. The nitrogen line to the PRT is not a Seismic Category I line and therefore its integrity throughout the post J accident period is not guaranteed.

Taken altogether (non-safety-related nitrogen source, direct connection to the reactor coolant system, and non-seismic design), there is insufficient justification for concluding that this line will not be a source of potential containment atmospheric leakage throughout the post-accident period. Conse-quently, an exemption in this case is inappropriate and valve ACV-RC8803.

should be tested in accordance with Section III.A.l. (d) of Appendix J.

3.1.6 Exemption Frem Type C Testing Recuirements for the Fire Protection Header Isolation Valves In Reference 5, CWE requested exemption from the Type C testing require-ments of Appendix J for vrive FCV-FP08,-the isolation valve in the fire pro-tection supply header. CWE's basis for this request is that this valvt' iso-lates a closed system inside containment which does not communicate directly with the reactor coolant system pressure boundary or the containment atmo-sphere. The system piping and equipment is located outside the missile bar-rier and, the re for e, is missile protected. This valve is in a closed pcsi-tion, and any leakage past valve FCV-FTG8 would be into the containment and not out since the fire protection header pressure of 100 psig is well above the containment post-accident peak pressure. CHE stated that no safety impli-cations are involved, and since the valve is normally closed, no provisions for leak testing are provided or required.

Evaluation Section II.H of Appendix J requires Type C testing of a normally shut valve such as FCV-FP08 when it can provide a direct connection between inside and outside containment atmospheres.

Section III.A.l. (d) of Appendix J 6

  • UNU Franklin Research Center A D>esenaf The Fearwnism ansasuas

~~-

TER-C5257-57/58 requires testing of this valve if the fire protection system co=municates directly with the reactor coolant system or if the fire protection system ruptures as a result of a LOCA.

The fire protection does not communicate in any way with the reactor coolant system or the containment atmosphere. Further, since the system is entirely located outside the missile barrier, it is unlikely to rupture as a rcsult of LOCA.

If the piping were to rupture (e.g., because of an intervening seismic event), the penetration is effectively sealed by 100-psig water pressure f rom the fire protection system. While this water pressure source is not safety-related, as a fire protection system it is designed to meet certain reliability standards and is capable of providing this water pressure for the entire post-accident period.

The reliability of this system is provided by two Seismic Category I pumps rated at 2000 gpm, one motor-driven and one diesel-driven, each taking a cuction directly from the crib hcuse forebay. The motor-driven pump, which rcceives electrical power from the essential bus, starts automatically if fire protection header pressure falls to 110 psig.

If header pressure falls to 100 paig, the diesel-driven pu=p starts automatically. The diesel-driven pump is bnttery started and requires no external electrical power for cperation. With Lake Michigan as a water supply, the system can provide a water seal at the containment penetration throughout the post-accident period. With regard to valve FCV-FP08, therefore, the fire protection system ef fectively serves as a caal-water system in accordance with Section III.C.3 of Appendix J.

Consequently, valve FCV-FP08 does not require type C testing because the fire protection system is a closed system inside containment which is unlikely to rupture af ter an accident and should it rupture, the penetration is water caaled. Since a water seal can be maintained at 1.1 Pa for at least 30 days, no exe=ption is required because the require ents of Section III.C.3 will be met.

l ON M!l FranMin Research Center A Duvemen af The 8,armen Insehme

u e

TER-CS257-57/58 3.1.7 Exeretion From Type C Testino Recuirements for the Residual Heat Removal System (PHR) Suction Line Valves In Reference 5, CWE requested exemption from the Type C testing require-ments of Appendix J for valve MOV-RH8701 and MOV-RH8702, the outboard and in-board RHR p p suction line isolation valves. GE's basis for this request is that these suction line isolation valves would normally be closed and filled with water under post-accident conditions. Any leakage past these valves wculd be returned to the RHR pump suction and wculd remain within the closed REn system.

Evaluation Section III.A.l.(d) of Appendix J requires Type C testing of containment isolation valves in systeas that cennect directly to the reactor coolant system pressure boundary.Section II.B of Appendix J defines containment isolation valves as those valves relied upon to perform a containment isolation function. Since any leakage past MCV-RH8701 and MOV-RH8702 is returned to the suction side of the RHR pumps, there is no possibility for leakage of containnent atmosphere through this path since the suction side of the RHR purps in a post-accident condition is continuously water covered by the pressure head of the containment sump. Consequently, these valves are not relied upon to perform a contain=ent isolation function, and therefore, Appendix J does not require that they be tested. No exemption from Appendix J is necessary.

9,

_nk!i,n _Res earch._ Center

e TER-CS257-57/58 4.

CONCLUSIONS Technical evaluations of requests for exemption frori the requirements of Appendix J were conducted.

The conclusions of these evaluations are cummarized below.

-o CWE's request for exemption to p6tf6cm local valve leakage rate tests (Type C tests) prior to the integr'ted primary containment leakage rate test (Type A test) and to bac h ot:act the results of the Type A test with the results of the Type C tect, using the conservative assumption that all measured local leakage is in a direction out of the containment, is acceptable.

CWE's proposal to test containment airlock door seals at 3 psig, using o

the penetration pressurizatien system for the after-each-opening requirement of Appendix J, is no longer required because of the revision to Section III.D.2 of Appendix J effective Oc tober 22, 1980.

CWE should ensure that its airlock testing program cenplies with the revised requirements of Appendix J.

CWE's request to exclude ccmponent cooling water valve ACV-CC9437 from o

Type C testing is acceptable. No exemption from Appendix J is required.

CWE's request to exclude nitrogen line isolation valve ACV-RC8033 from.

o Type C testing is not acceptable. The valve should be tested in i

accordance with Appendix J.

1 CWE's request to exclude nitrogen line isolation valve ACV-SIB 880 frcm o

Type C testing is not acceptable. The valves should be tested in accordance with Appendix J.

CWE's request to exclude fire protection header isolation valve o

l FCV-FP08 from Type C testing is acceptable. No exemption from Appendix J is required.

l CWE's request to exclude RHR isolation valves MOV-RH8701 and o

MOV-RH8702 from Type C testing is acceptable. No exemption from Appendix J is required.

1 i

l l

l