05000366/LER-1981-035-03, /03L-0:on 810413,during Steady State Operation, Reactor Bldg to Torus Vacuum Breaker Isolation valve,2T48- F310,failed to Open Due to Failure of Differential Pressure switch,2T48-N210.Mechanism Cleaned.New Switch Ordered

From kanterella
(Redirected from ML20008F947)
Jump to navigation Jump to search
/03L-0:on 810413,during Steady State Operation, Reactor Bldg to Torus Vacuum Breaker Isolation valve,2T48- F310,failed to Open Due to Failure of Differential Pressure switch,2T48-N210.Mechanism Cleaned.New Switch Ordered
ML20008F947
Person / Time
Site: Hatch 
Issue date: 05/05/1981
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19345H295 List:
References
LER-81-035-03L, LER-81-35-3L, NUDOCS 8105120383
Download: ML20008F947 (2)


LER-1981-035, /03L-0:on 810413,during Steady State Operation, Reactor Bldg to Torus Vacuum Breaker Isolation valve,2T48- F310,failed to Open Due to Failure of Differential Pressure switch,2T48-N210.Mechanism Cleaned.New Switch Ordered
Event date:
Report date:
3661981035R03 - NRC Website

text

y c

LICENSEE EVENT REPORT p

CONTnol DLOCK: )

l l

l l

l (PLEASE PRINT OR TYPE ALL HEcOIRED INFORMATl!N) v 1.G l A T E lI lH l 2 l@l0 l0 l-10 10 10 l0 l0 l-l0 l0 l@l 4 l 1 l 1 l 1l 1l@l l

l@

1 o i 7

8.

ucoNsu coot i4 is act~se Nue.tn a

w uct~st nrE o

,7 u i sa 3g"c Ql0 l5 l0 l0 l0 l316 l6 l@l 0l 41 Il 3l 811 l@l 015 ! 0 ! 5 l 8-l 1 l@

'L T

o od 6')

EVENT DATE 14 th Hk PGA T DAT E 1i0 60 61 DOCKL1P.UYdEH 7

8 EVENT DESCRIPTION ANo pro 8 ABLE CONSEQUENCES h While the plant was in steady state operation at 2282 kit. Reactor Buildinq

[

O 2 l to Torus Vacuum Breaker Isolation Valve, 2T48-F310, failed open. Tech

[

O 3 l Specs 3.6.3 requires that primary containment isolation valves be operable.

I IUTl l Redundant Reactor Building to Torus Vacuum Breaker Isolation Valve, 2T48-j l

O s i O s I F311, was operable.

Plant operation was not affected as a result of this l

event. The health and safety of the public was not affected. This is a

[

10171 I f

50-366/1980-96.

l repetitive event as reported on Reportable Occurrence Report O s l 80 DE CODE SUSC E COMPONENT CODE SUSC dE E

Q lS lD j@ y@ lE l@ lIl Nl Sl Tl Rl V[@ W@ W@

7 8

9 IO 31 32 la 18 19 20 REVISION SEQUENTI AL OCCURRENCE REPORT EVENT vE AR REPORT NO.

COOE TvPE NO.

@,agg/RO18111 l-l l0131SI (d]

1013I IL l

[-]

[0j LER

,,_2 t 22 23 24 26 27 28 29 30 38 32 KEr ACT ON O PLANT

  • ETH HOURS S BP IT FORf1 8.

$ PLIE MANUF. TuRER l E]gl Zl@

l Z]@

l Zl@

l 010l Ol 01 LY_j@

lNi@

lAl@

lSl3l8l2[@

33 34 35 36 3/

40 41 42 43 44 47 CAUSE DESCRIPTloN AND CORRECTIVE ACTIONS h I

The cause of the event has been attributed to Reactor Buildina to Torus 1i101l i

Differential Pressure Switch, 2T48-N210. The failure was due to too creat i i l

I of a reset span possibly caused by a sticking switch mechanism. The mech-TTTF1 I anism was cleaned with a cleaner lubricant and the switch exercised several I

l,131 l l

times and returned to service. A new switch has been ordered.

i 4 l

OTHERsTATus bS'se"O S0v' OisCOvEnv oEscaiPriON

'stSEs*

c l

r, POwE R li Ib l [E_J@ l 0l 914 l@l NA 1

LA_l@l Operator observation f

8'

'S A!rivity COTTtN1 LOCATION OF RELEASE l

NA l

l NA l

AELE ASED OF RELEASE AVOUNT OF ACTIVITY [Z_j @ [ Zj @ M ts i c

' etnsONNti rxros DE scetiPriON @

l Nuenen tveE NA [0 l 0 l 0 l@l Z l@l i 7 etnsONNE t iN;u'iiits otsen.eriON@

l NuenE n NA l 0 l 0 l 0 j@l i a 80 7

8 9 11 11 l

TvPE JESCT PIION NA [119 lZ_j@l 80 7

8 9 10 unc usE oNLY issud["@I'tscnierioN g HA I

IIIIIIIIIIIII2 [f

l bb-m f

2 o B*1'051'gu R. T. Nix, Supt.of ttaint.

pnouc; e

non m

LER No.: 50-366/1981-035 Licensce: Georgia Power Company facility: Edwin I. itatch Doc ke t - No. : 50-366 N0rrative Report for LER No. 50-366/1981-035 '

On April I',1981, while the plant was in steady state operation at 2282-Milt, Reactor Building to Torus Vacuum Breaker Isolation Valve, 2T48-F310, failed open. Tech Specs Section 3.6.3. requires that primary containment isolation valves be operable. Redundant Reactor Building to Torus Vacuum Breaker Isolation Valve,-2T48-311, was operable. Plant operation was not.

affected as a result of-this event. The health and safety of the public was not 'affected. This event is repetitive as last'-reported on Reportable Occurrence Report No. 50-366/1980-96.

The cause of the event has been attributed to Reactor Building to Torus Differential Pressure Switch, 2T48-N210. The failure was due to too great of a reset span possibly caused by a sticking switch mechanism. The mech-anism was cleaned with electrical contact lubricant cleaner, then' exercised

~

several times and checked for correct operation. The switch was then recalibrated per !!NP-2-5240, Static-o-ring Pressure Switch Calibration, and returned to service.

A new switch has been ordered to replace the existing switch.

A generic reveiw revealed no inherent problems with this switch for this particular application.

Unit I does not use this type switch for this application.

M