Distribution:
FEB 13 1981 NRC PDR 9
t Docket No. 50-293 ORB 42 rdg D. Eisenhut/R. Purple OELD 01&E (3)
T. Ippolito Mr. A. Victor Morisi, Manager M. Williams Nuclear Operations Support Department S. Norris q g,g' Boston Edison Company NSIC O
M/C Nuclear TERA 4
800 Boylston Street ACRS (16)
/
4G ys Boston, Massachusetts 02199 J. Heltemes, AE0D E
s,;p # *7 A
r
Dear Mr. Morisi:
9
/
[--
7
\\
A3
SUBJECT:
ATWS RPT/ARI DESIGN O
N Reference (a)
BECo 80-57, April 7,1980
'<g, [
We have completed our review on the subject and forward the enclosed safety evaluation for your infonnation.
The Technical Specifications of the enclosure were effected by Amendment No. 42 to your license. However, the evaluation also doctanents the telecon between our staff and BECo (Williams /
Fulton, Deacon,1/21/81) regarding installation / testing of the power supplies and inverters.
These items should be installed during the first prolonged outage (seven days) afte-April 1,1981 and, in any case, not later than your scheduled October refue' '1 outage.
No response to this let;e 1's necessary unless the above installation schedule is changed.
Thank you for your cooperation in this matter.
Sincerely.
Original Signe5 ggi 4 A.Ippoco Thomas A. Ippolito, Chief Operating Reactors Branch #2 Division of Licensing
Enclosure:
Safety Evaluation cc w/ enc 1:
See next page l
8108120001 y
9
$W'
~
- m ot :
ot:0aB42
> MIhl[iUms':ms tM-9 2/1 /81 2/jj/81
^,
~
~[
%,#^
UNITED STATES f
NUCLEAR REGULATORY COMMISSION y*
, j WASHINGTON, D. C. 20555 e
%%..,/
February 19, 1981 Docket No. 50-293 Mr. A. Victor Morisi, Manager Nuclear Operations Support Department Boston Edison Company M/C Nuclear 800 Boylston Street Boston, Massachusetts 02199
Dear Mr. Morisi:
SUBJECT:
ATWS RPT/ARI DESIGN Reference (a) BECo 80-57, April 7, 1980 We have completed our review on the subject and fomard the enclosed safety evaluation for your information. The Technical Specifications of the enclosure were effected by Amendment No. 42 to your license. However, the evaluation also documents the telecon between our staff and BEco (. Williams /
Fulton, Deacon,1/21/81) regarding installation / testing of the power supplies and inverters. These items should be installed during the first prolonged outage (seven days) after April 1,1981 and, in any case, not later than your scheduled October refueling outage.
No response to this letter is necessary unless the above installation schedule is changed.
Thank you for your cooperation in this matter.
Sincerely, A0 Q Qs A..PD Thoma ppolito, Chief Operating Reactors Branch #2 Division of Licensing
Enclosure:
Safety Evaluation cc w/ encl:
See next page r-
i Mr. A. Victor Morisi Boston Edison Company cc:
Mr. Richard D. Machon Pilgrim Station Manager Boston Edison Company RFD #1, Rocky Hill Road Plymouth, Massachusetts 02360 Henry Herrmann, Esquire Massachusetts Wildlife Federation 151 Tremont Street Boston, Massachusetts 02111 Plymouth Public Library North Street Plymouth, Massachusetts 02360 Resident Inspector c/o U. S. NRC P. O. Box 867 Plymouth, Massachusetts 02360 O
i e
e v