05000277/LER-1981-010-03, /03L-0:on 810127,drywell Radiation Monitor Found Out of Svc During Full Operation.Caused by No Sample Flow Through Sys Due to Manual Sample/Purge Valve Dislodged from Normal Sample Position.Valve Returned to Position

From kanterella
(Redirected from ML20008E956)
Jump to navigation Jump to search
/03L-0:on 810127,drywell Radiation Monitor Found Out of Svc During Full Operation.Caused by No Sample Flow Through Sys Due to Manual Sample/Purge Valve Dislodged from Normal Sample Position.Valve Returned to Position
ML20008E956
Person / Time
Site: Peach Bottom 
Issue date: 03/02/1981
From: Cooney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20008E955 List:
References
LER-81-010-03L, LER-81-10-3L, NUDOCS 8103100626
Download: ML20008E956 (1)


LER-1981-010, /03L-0:on 810127,drywell Radiation Monitor Found Out of Svc During Full Operation.Caused by No Sample Flow Through Sys Due to Manual Sample/Purge Valve Dislodged from Normal Sample Position.Valve Returned to Position
Event date:
Report date:
2771981010R03 - NRC Website

text

I anC ronu s s o a.auetuaaaccuL,uolic w x.n..sivu 1 11) f Nit 2 LICENSEE EVENT REPORT Report No. 2 10/3L J

CONTROL BLOCK: l l

l l

l l

l (PLEt.SE PRINT OR TYPE ALL REQUIRED INFORMATION) i e

iTilivIAlP!B lS I 2 l@l Ol 0l -l0 l 0l 0l Ol 0 l -l Ol O l@l 411 l 1 l 1l 1 l@l l

l

'AT 39 @

d

'J LICENSEE CODE 14 15 LICENSE NUM0ER 25 26 LICENSE TYPE JO 51 CON'T 0Iti S$"CE l L l@l0 l 5 10l -l Ol2 17 l7 !@l9l112 l7 l3 l1 l@l013l^!2l^!Il@

6 60 61 DOCKET NUVSEH 68 t9 EVENT O ATE 74 15 REPORT D AT E d3 EVENT DESCRIPTION ANO PROSABLE CONSEQUENCES h o121l With the unit operatin; =: full t o rer t' e drreell radiation i

o ;3; I monitor was found to be out of service due to lack of sample flow. No I

o l.i j l increased dr.~.rell leakage was observed durin-the period when the l

o Isi I rad monitor was out of service. Applicable Tech. Spec. is 3.5.c.

I o is i l l

Ol7l l l

o la i l I

8 9 SO SYSTE M

CAUSE

CAUSE COMP-VALVE CODE CODE SUSCODE COMPONENT CODE SU8 CODE SUSCODE o191 l S lE lh Wh l Z l@ l Vl Al Ll Vl El Xl@ lX l@ lD l@

8 9

to 11 12 13 id 19 20 SEQUENTIAL QCCURRENCE REPORT REVISiCN LER EVENT VEAR REPORT No.

CODE TYPE N O.

h,agg/Ro I8111 1-l 10 1110 I 12 1013I IL I l-l 10 l

_ 21 22 23 24 26 27 28 20 30 31 J2 K

A O

o LANT MET HOURS 22 S8 iT FOR4 US.

SLPPLI MAP FACT RER [1_]@(.G_j@

W@

l Z lh l0 l0 l0 l0 l l Yl@

lY]@

l A l@

l A l5 l3 l5 l@

33 34 35 3G 34 40 di 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h iioll The dryell rad monitor uas observed to have no sample flow throu*h I

ilil l the system due to a manual semOle/rurce valve being dislodTed l

,i,,l from its normal sample position durin; a surveillance test. The valve i

,i,il was returned to the sample position, restoring the l

i ;4 l l rad monitor to service.

l 8 9 80

$A S

% power OTHER STATUS 01S 0 Y

discovery OESCRtPTiCN iIsllEl@ l1l0l0l@l NA l

lAlgl Technician observation l

ACTIVITY CO TENT AMovNTor ACTIVITY h l LoCAfios os RELEASE h af te4SEn cr aELEASE

' i 16 l IZ l h l Zl@l l

NA l

NA 8

9.

10 31 44 45 80 PERSCNNEL EXPOSURES NUMOEH TYPE DE SCRIPTION 1 I 71 l0 l0 l0 l@lZl@l NA l

PERSONNEL INJURIES NUV8ER DESCRIPTnON ibil0l0101@l I

4 9 11 12 80 LOSS OF OR DAMAGE To FACILITY Tvet CESCRIPTICN iI9i LZ_J@l NA -

I G 9 10 80 6SSUE OE CRIPTeoN 21oib_[81 NA

%u l

lII!IIl!IIl!l5 81031004#6 i NAME OF PREPARER ~

/ 6 cooney [215E841-5020 l

. ^

PHONE: