,mg

],.

4

- -~-

'~'

$h?

q:

4 c

h,* :

g,

,a 9.e I

i 0FTRAliNGDATAREP07,1 1

f DOCLET WD-50-369 ' _

'l f>

DATEJanuary 15, 1990 i

p

' opt MTING $iATUS COMPLETEDBY R.A. Williams TELEPHONE 704 373-5987

't.Unithace:McGuire1

2. Reporting Period December 1, 1989-December 31,1989

'I

13. Licensed Thereal f%er (Mth 3411.

l

' 4.' Nameplate Rating (6ross Meh 1305a '

Notes 'Naseplate Rating.

L5. Design _flectrical 8tating (het We):

1180 (6ross Nel calculated as.

6i Martsue Dependable Capacity (Stess M eli 1171 1450.000MW1s.90 power W
7. Matteus Dependable Capacity (Net Ne) :

1129 factorperPage'111, B. If Changes Occur in Capacity Ratings (!!ess Nueber 3 Through 7) Since Last NURE6-0020.

Repart.-31ve Reasons 9, Power Level To Which F.estricted, If Any (Net Me):

10. Reason For Restrictions, If any

~

A a

i i

This Month Yr.-to Date Cumulative.

)f

11. Hours in Reporting Period 744.0 8760.0

.70872'.0 l

12. Number Of Hours Reactor lias Critical 744.0 7210.B 50850.1 n
13. Reacter Reserve Shutdown.H9urs

--0--

--0--

--0--

o '

14. Hours Generator On-Line '

744.0 7109.0 50298.9

'i 15.UnitReseryeShutdownHours

--0--

--0--'

s 16.StessThersaiEnergyGenerated(NH) 2530503 23777200 151600733

17. BrosiElectrical Energy Generated (NH)

B009Y7 9128720 52227677_

+

IB.iNetElectricalEnergyBenerated(NH) 649690 l7800959-49006383 19.UnitServiceFactor 100.0 02.1 71.0 i

20. Unit Availability Factor.

100.0-62.1 71.0,

j

' 21. Unit Capacity Factor (Using MDC-Net)

22. Unit Capacity Factor (Using DER Net).

101.0 78.9

~60.7:

q 96.7

' 75.5 -

59.7' t

+

23.1 Unit Forced Dutalt Rate' O.0 17.9 12.3 s

24. Shutgown 5tjefng Orgt Next 6 Months (T pe, Date, and Duration of Eachh

?

uled t

efue

.. arch 28,c199 - 12 weeks g

. 25. If Shut Denn At End Of Report Period. Estisated Date of Startup

'[

26. Units In Test Status'(Prior to Cossercia Operation):

Forecast Achieved t

INITIAL CRIT!rALITY INiilALELECTRICITY b

COMMERCIALOPERATION

t i

B i

L a

mm

4-

.e l

0FERA11NSDATAREPORT DDCLET WD 50-?69 UNii M ulte 1 DATE k neaty 15,,1990 COMPLETEDBy R.A. Williens TELEPHONE 704 373-5907 M0KTH Detester,1999 El AVERABE DAILY PDWER LEVEL El AVERABE DHILY FtWER LEVEL (MWe-Neil (MWe-Net) 1 1141 17 1139 2

_1141 10 1141 3

1143 19 1141 4

!!43 20 1139

]

4 5

1145 21 1143 6

1145 22 1139 7

1142 23 1138 E

1134 24 1130 9

1135 25 1138 10

!!39 26 1142 11 1140 27 1142 12 1141 26 1143 13 1140 29 1143 14 1142 30 1143 15 1143 31 1141 16 1139 e

g gy 9 -

L.y

. g.39[ _y3-y_s ge - -s n

. :g ',

.x wqyy ngym c3,

q&' * '

3~,

p.,;pgp;:rgy

,4y p.

y'

,.. _.: 7;

-, yy. %;.-

.3

'T b-p: gi:f~p;:rg;

,w l

'.l:4 g

7;:'

a'

g p; T "

7 3. ' ; A q

]gi

  • ^

n e

g.

_.UNITiSHUTDOWNS AND: POWER: REDUCTIONS-DOCKET?NO.o 50-369------------a-- -.7, n

.c

.e

~

p...

,,w 4

,; g us s.

l'-M*

c

_~

UN I T : NAME __f1CQQIRE_L___;,-KN

~

-- /15/90-M'

. 'DATE:

01

  • y.

IREPORT/ MONTH d 1 December 1 0 9 9 '-

COMPLETED.BY,..gSj_Wi_ M R 2 ; j TE.LEPHONE^-(704)-273 S76,2 z'

~

~~

~

E.

R' MET-(1)

(2)

(3)

(41-

. 5)

(

1 E :-

l'0D1

~~

T' A - - } OF..

LICENSE.'

l

. s i.

-N y:

S.

SHUT EVENT-GYS-

- CAUSE AND : CORRECTIVE '. _..

f

' i:f D --

P DURATION O'-

DOWN REPORT TEM COMPONENT.

~ ACTION TO r..

DATE..

E HOURS N

R/X NO. -

CODE CODE

. PREVENT ' RECURRENCE 1 NO SHUTDOWNS OR REDUCTIONS

]

~

K-i A,

J w _:

.E s.

i e

1 1

1 l

. l..

l,.

I f

i (1)

(2)

('3 ) "

(4):

F' Forced-Reason:

'Nethod:

ExhibitiGi-: Instructions LS. Scheduled

.A-Equipment Failure (Explain).

L1-Manual-.

for Preparation of Datai B-Maintenance or test-2-ManualiScram; Entry Sheets For License 4

,C-Refueling: Automatic Scram:

EventLReport-(LER)

D-RegulatorylRestricticn.

LA-Other'(Explain)-

FileJ(NUREG-Ol61')

'E-OperatortTraining" 8. License Examination -

s

~ F-Admini stra*.i v. e '

'(5)=

~

G-Operator (Error;(Explain)...

~,. _

.ExhibitEI

..Same? Source::

^

^

~-

l: -

2 H-Other :i(Explain);

e-

_y y

~

~

J.

.,,6.. h,.a s. -

NE u.

f

_. _ - ~

i 4-j

. '. -=

R'

~

pp DOCKET NO:. 50-369 v

i i

UNIT: McGuire 1

{. -- < _

+

DATE:

01/15/90 j

j F

. i NARRATIVE SUP94ARY

<j 1

l T

Month: December 1989 McGuire Unit 1 began the month of December operating at 100% full power. The-1 l

' c

[

unit operated the entire month with no significant reductions in power,'and ended the month operating at 100% full power.

i t

i i

h i

{

r

b, '

. s i

Prepared by: S. W. Moser 704-373-5762 Telephone: _

I 1

s i

f y

.r...

-,-,-4

,. ~

,+.,sa.,s.,-wa.r.--,--,an.~.

,r.,.ee-e,

,aw,p

,.w, r..

sm,

S t

+-

{-

i n

l MONTHLY REFUELING INFORMATION REQUEST L

s l

' 1. - Facility name: McGuire. Unit 1

[

2.

Scheduled next refueling shutdown: March 1990 3.

Scheduled restart following refueling: June 1990 4.

Will refueling or resumption of operation thereafter require a technical specification change or other license amendment? fLo If yes, what will these be?

If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unroviewed safety questions? N/A j

5.- Scheduled date(s) for submitting proposed licensing action and supporting information: N/A 6.

Important licensing considerations (new or different design or supplier, I

unreviewed design or performance analysis methods, significant changes in design or new operating procedures).

7.

Number of fuel assemblies (a) in the core:

193 i.

(b) in the spent fuel pool:

369 l

i 8.

Present licensed fuel pool capacity:

1463 Size of requested or planned increase:

9i, : Projected date of last refueling which can be accommodated by present licensed capacity: October. 2004 l-l DUKE POWER COMPANY DATE:

January 15, 1990 Name of

Contact:

J. A. Reavis' Phone:

704-373-7567

O

,}*,

?

v.

ti s

u r

5 o

OPERATING DATA REPORT

. DOCKET ND

'50-370' a

DATEJanuary 15 1990 s

OPERATIN6 STATUS.

CDMPLETED BY R.A. Willines g

TELEPH3NE 704-373-5987 4'

!. Unit Names McGuire 2-s

,l

2.ReportingPeriod
December 1,1989-December 31,1989
3. Licensed Thereal Power TWth' 3411 i

.4i Naseplate Rating (6tess Me):

13054-J:5.' Design Electrical Rating (Net We).

!!00.

Notes eNaseplate Rating-

-(

(6ross MWel calculated asi

?

6. Marisue Dependable Capacity (6 toss MWeh

!!71 1450.000 WA t '.90 power b

17J Marious Dependable Capacity TNet Neh

~ !!29 factor per Page lit,

~. If Changes Occur.In Capacity Ratings-(itees Number 3 Through 7) Since Last NUREG-0020.

O 8

' Repert. Elve Reasonst' jh

9. Power Level Te Which Restricted, If Any (het MWe):

J I

10.ReasonForRestrictions,Ifany:

b V

a p

f g

3c y

This Month Yr.-to-Date

.Cueulative 11.HbursinReportingPeriod 744.0 -

6760.0 51168.0 k

  1. 12. Number Of Hours Reactor Was Critical 744.0

~ 943.4 38702.0 i

6 113. Reactor Reserve Shutdown Hours

--0--

--0--

--0 J' Ii il4. Hours 6enerator On-Line 744.0 6869.2 37928.0 i

J15.-UnitReserveShutdownHours

--0--

--0---

'.--0--

16. 6 toss.Thereal Energy Generated IMH) 2469574 2194B166 123261270
17. Gross Electrical Energy 6enerated (WHL 864547 772B779

-431826611 ti 218. Net Electrical. Energy Generated (WHL B52436 7412762 41402297-

=19.UnitServiceFactor In0.0 78.4-74'.1 120iUnitAvailabilityFactor' 100.0 78.4 74.1 21.. Unit Capacity factor (Using M C Net) 101.5 75.0-70.2' 122i Unit Capacity Factor (Using DER Net) 97.1 71.9

.68.6'

23.UnitForcedOutageRate 0.0 0.9 10.2 l24. Shutdown.ScheduledOverNext6 Months (Type,Date,andDurationofEach)

~None" n..

s 3.-

.,25. !f. Shut Denn At End Of Report Feriod. Estimated Date of Startup -

26 Units in Test Status.(Prior to Coseercial Operationh Forecast Achieved INITIALCRITICAlliy-INiilAL' ELECTRICITY

- COMERCI AL OPERATION j

c.'

j 8

i ', A

m, =+

s.

.; m' c,,

.. 3;;,c.

^

w

-r s.

n

" (&;q,

f, ' pM : ( _,

,, ~ ~

c 1

e 2%X l; Lf-J

s/

T-

.l '

y f_

~

1 3R c?gh g

<.m

.jg

, W'

.b,, f-7 4

~ 'C t.. '

z.

m.

-)

M J...

OPERATIN6 DATA REPORT yw3 i

r s

.t.

r DOCKET ND' 50470 uni? -

McBulte 2 DATE January 15. 1990 EOMPLETEDBY R.A. Williner.

l

-TELEPHONE 704-373-5987 i

p'

L V-t.. g yy:

~ December 1999-3, w

,aw

. E, AVERA6 EDA!LYPOWER'EVEL-E AVERAGE DAILY PDWER LEVEL-L a

UtWe-Net)~

(MWe4t t) -

?

.t

li 1127-17 1159 2

1121 18 1159-

.t

' 3' 1157 19 1160 e

4q

'1157 20 1160

_ 5:

1138 21'

~ 1160 j

6:

2115B -~

22

'!!60 f

7.1 1150~

23 ~

1160

)8.

- 1120 '

- 24 '

1151 -

i

,c.g

+

j 3

9.'

1114 25 -

'1160 l

~

1157-.

26 '.

1161 1

10

'1150 27 1160

_q

- 12 1!59 :

28.

'!161 x

i 13

- 1150 -

- 29 1162 m

i 14~

1159-30 107B' N

15.:

1159-31 1011-t

'llh)I

?

4 s

4

--5' n.

g

+

?gq:yg}w)[y.:v,[Q47 $%[W;$~;

mpp - y3:pc:

yx=,

/

gy-

~

an,

.m

- g e

y M,9.,~.M~', ~

.d%.d I ~ ' _

-]J 9[ N

%7

. [W M - IGE

+

.l'n,

.Lf2

~r I.if

,f

~',

eQ, j,[

};

"r

'1 I

II[.

U.14 -

[-

p.

u.i. -

P~

. 5

]f Q(, '

Of5 1

mo

~

DOCKET NO.D.'50-370

J r M - -Jf

'T

.UNITiSHU1 DOWNS AND: POWER' REDUCTIONS 1 t

~

g.

.. UNI TI NAME_~ M_C_G_U_I R_E__' 2_.-

_1 "w__.Y I

.g 1"DATE %O1(15LTO L ii n_4 w

REPORTcMONTH

. December 1989'

^. COMPLETED ' = BYj ;S. _%fi_, fmri.2M.,

~

- TELEPHONE?:_,1204 )-373 ;5_*7dj2_4

~

2+

W (l')

(2)

(3).

(4)-

(5):

.g R

MET-c:-

~

' ' ~ ^ ~

E-HOD '.

? -

n

~'

G-T-

A QF.

IICENEE" j

Y.

SL SHUT EVENT" SYS-

.CAUSE:AND-CORRECTIVEC m N ~-

.O1 P:

DURATION O-DOWN 4 REPORT-TEM COMPOfJENT1 ACTION'TO T.

DATE

.E1 HOURS N.

R/%

NO.;

CODE CODE...

PREVENT RECURRENCE <

NO

" SHUTDOWNS

.. OR REDUCTIONS

~

~

c pl a

- l.;

j '

.I

,~

l s..

I l

l_

r

'.[

I

-l-'

l i

I 41

=

7.y'

~ ( 1 )'

(2)

(3)

(4)

F Forced Reason:~

. Method:

_ Exhibit G~-~ Instructions 1-. Manual

~

~for Preparat, ion'off Data-

,5 Scheduled

A-Equipment-Failure?(Explain)

J B-MaintenanceLor test 2-Manual' Scram'

.. Entry. Sheets - ForJ License 4 *

-C-Refueling :

3-Automatic: Scram

. Even t-i Repor t 1 (LER ) L D-Regulatory Restriction:

4-Other =. (Exp la in) :

File-(NUREG-0161)1 E-OperatorFTraining'8. License! Examination

~

~

F-Administrativer (5)~

c

~

-t.-

' Exhibit IIi---SameLSourcee G-Operator, Error?(Explain);-

.. ~

H-Otherf.(Explain)D 9'-

=

^

.. u-

., ;.; a c[ '

A,..a T

s...

JI

^

'~

w -, ~..a w.; a.. - _.,.

--a,

,. m..

...--c

r

. r ;.

I f '*,

s' k.$

e DOCKET NO:

50-370 UNIT: McGuire 2 DATE:

01/15/90-p.

NARRATIVE

SUMMARY

Ln f

Month:

December 1989 b

'McGuire Unit 2 began the month of December operating at 100% full power. The 1

unit operated the entire month with no significant reductions in power, and

~

E ended the month ~ operating at 100% full power, f

L

\\

o I

i:.

I"

)

. l' t

E

' Prepared by: S. W. Moser LTelephone: 704-373-5762 1:

I' 1

e

,C MONTHLY REFUELING INFORMATION RE0 VEST 1.

Facility name: McGuire. Unit 2 2.

Scheduled next refueling shutdown:

September 1990 t

l-3.

Scheduled restart following refueling: November 1990 4.

Will refueling or resumption of operation thereafter require a technical specification change or other license amendment? No

-If yes, what will these be?

If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions? N/A 5.

Scheduled date(s) for submitting proposed licensing action and supporting information: N/A l

l 6.

Important licensing considerations (new or different design or supplier.

j unreviewed design or performance analysis methods, significant changes in l

l design or new operating procedures).

i.

7.

Number of fuel assemblies (a) in the core: 193 l

(b) in the spent fuel pool:

590 8.

Present licensed fuel pool capacity:

1463 i

Size of requested or planned increase:

i 9.

Projected date.of last refueling which can be accommodated by present licensed capacity:

July, 2002 1

i -

DUKE POWER COMPANI DATE:

January 15. 1990

-Name of

Contact:

J. A. Reavis Phone: 704-373-7567 4