Notice of Violation from Insp on 891127-1201.Violations Noted:General Area Dose Rates on Drywell Mezzanine Above 100 Mrem & Background on Scintillation Alpha Counter Operation in Use W/O Instrument Being Decontaminated
ML20005F196
Person / Time
Site: FitzPatrick 
Issue date: 12/29/1989
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20005F191 List:
References
50-333-89-21, NUDOCS 9001160038
Download: ML20005F196 (2)


Text

L r

)

i APPENDIX A NOTICE OF VIOLATION i

New York Power Authority Docket No. 50-333 James A. FitzPatrick Nuclear Power Plant License No. DPR-59 As a result of the inspection conducted on November 27 to December 1, 1989, and i

in accordance with the NRC Enforcement Policy (10 CFR 2, Appendix C), the i

following violations were identified.

to be made such(b) requires,(1) may be necessary for the licensee to compl 10 CFR 20.201 A.

surveys as are reasonable under the i

with the regulations in this part, and (2)diation hazards that may be circumstances to evaluate the extent of ra j

present.

while touring the reactor building on November 28 Contrary to the above,ted that the general area dose rates on the drywell i

1989, the inspector no mezzanine were above 100 millirem /hr. Access to this area was not j

and the area controlled in accordance with Technical Specification 6.31 (a)CFR was not osted as a High Radiation Area in accordance with 10 1989 20.203(c. The most recent survey of this area was dated November 3 and indi ated the general area dose rate to be 50 millirem /hr. The licensee resurveyed this area and determined the general area dose rate to be 280 millirem /hr.

This is a Severity Level IV Violation.

(SupplementIV) j i

B.

Technical Specification 6.11 " Radiation Protection Program" requires, in 1

part,dhered to for all plant operations.that procedures for personnel radia and a 1

Procedure RTP-23 " SAC-4 Scintillation Alpha Counter Operation and in Section 4.6.1 1

Calibration" dated November 23, 1987, requires, in part,inutes, then that if the background is greater than 3 counts per 10 m decontaminate the instrument. Section 4.8 of this procedure also requires notification of a Radiological and Environmental Services (RES) Supervisor j

if any problems are encountered that cannot be resolved through the use of j

this procedure.

Contrary to the above, from November 8 to 28, 1989 the background on the SAC-4 (No. 440) in use at the control point ranged from 15 to 42 counts per 10 minutes without the instrument being decontaminated or RES Supervision being notified.

This is a Severity Level IV violation. ( Supplement IV )

1 I: s

-. c.. u 4.A.a L, f g

.s 9001160038 891229-PDR-ADOCK 05000333 G

P N U.

L i..

APPENDIX A 2

l Pursuant to the provisions of 10 CFR 2.20) the Power Authority of the State of New York is hereby required to submit to tbis office within thirty days of the l

a written statement or date of the letter which transmitted this Notice (1)thecorrectIvestepswhichhavebeentaken explanation in reply, including:corrective steps which will be taken to avoid andtheresultsachieved{*[2)hedatewhenfullcompliancewillbeachieved.

further violations; and 3jt Where good cause is shown, consideration will be given to extending this response time.

-l

)

l 1

4

-