I COP 3Um8FS PcWer James W Cook Vice President - Projects, Engineering and Construction General offices: 1945 West Parnali Road, Jackson, MI 49201 * (517) 788 0453 June 30, 1981 Mr Victor Stello Director of Office of Inspection and Enforcement US Nuclear Regulatory ommission Wrzshington, DC 20555 MIDLAND NUCLEAR PLAITT - ALAB-106 QUARTERLY REPORT DOCKET NOS 50-329 AND 50-330 FILE:

0.4.6 UFI:

07.01 ALAB*QT SERIAL:

12033 Pursuant to the second and third conditions of the Memorandum and Order ALAB-106 dated March 26, 1973, and Amendment.No 1 to the Midland Plant Construction Permits, we are submitting ten (10) copies of our thirty-fourth

( 3hth) report covering the period July 1 through September 30, 1981.

m

4. lad WRB/lr CC: RJCook, USNRC Resident Inspector Midland Nuclear Plant JGKeppler, USNRC Region III l
  • db hf' e

f d'cV. ~h s l

l ss u _s_

y JUL G 71981

  • g 5 \\

o... wey. naum

-1 l

?

= = ' " *

  • q/

,Q,

</

i

.. ('s f2 8107000241 810630 PDR ADOCK 05000329 II I

E>R d

PDR l

l

Y 6

CONSUMERS POWER COMPANY Rei <% f34, June 30, 1981 Pursuant to Conditio-FB and 2 FC of Construction Permits CPPR-81 and CPPR-82, the following report covers the period July 1,1981 through September 30, 1981.

A.

Construction work to be performed during the period:

See Attachment A B.

Personnel with quality related duties who were assigned to the Midland Project during the period April 1 through May 31, 1981 and who are expected to be on site through June 30, 1981 and who will be trained as necessary to perform the functions required of them are as follows:

1.

Midland Project Quality Assurance W Agerter - MPQA G Anderson - Fluids / Mechanical IE&TV J Busby - MPQA M Butterfield - Civil QAE M Curland - MPQA R Davis - Welding / Mechanical IE&TV J Decker - Welding / Mechanical IE&TV J Dittenbir - MPQA W Doig - Fluids / Mechanical IE&TV A Francis - MPQA D Goldstein - MPQA

v 4

2 1.

Midland Project Quality Assurance (Cont'd)

H McGrane - MPQA J Obermeyer - MPQA E Oswood - Electrical IE&TV H Perrine - Electrical ('AE A Schlaifer - Civil QAE J Smith - MPQA M Verderosa - Fluf

/ Mechanical QAE 2.

Bechtel Quality Assurance / Quality Control R Aubert - Quality Control Mechanical / Piping L Berestovetsky - Quality Control Civil R Bersch - Quality Control Mechanical / Piping J Black - }uality Control Supervision J Brownell - Quality Control Mechanical / Piping J Clark - Quality Control Mechanical / Piping R Clark - Quality Control Civil C Cross - Quality Control Mechanical / Piping R Danbury - Quality Control Electrical W Fedorow - Quality Control Electrical C Groat

-Quality Control Civil T Hahn - Quality Control Electrical J Hannah - Quality Control Mechanical / Piping W Havrilchak - Quality Control Civil R Hayes - Quality Control Mechanical / Piping l

I--

p, v

G 3

o 2.

Bechtel Quality Assurance / Quality Control ( Cont'd)

A Heikkinew - Quality Control Mechanical / Piping J Herbert - Quality Control Mechanical / Piping B Hines - Quality Control Mechanical / Piping J Howard - Quality Control Electrical M Kale - Quality Control Civil T King - Quality Control Civil R Kozak - Quality Control Electrical D Kremarik - Quality Control Electrical K Krug - Quality Control Civil A Martin - Quality Control Civil J Mattioli - Quality Control Civil D McCorkle - Quality Control Mechanical / Piping W McCoy - Quality Control Civil L McGonical - Quality Control Mechanical / Piping W Peery - Quality Control Electrical L Peterson - Quality Control Electrical J Porebski - Quality Control Electrical l

S Revich - Quality Control Electrical A Rigoni - Quality Control Electrical R Schaut - Quality Control Electrical i

R VanDenBosch - Quality Control Welding F Wood - Quality Control Civil 3.

B&W Contruction Company No Additions l

l l

L 4

4 4.

Project Management Office AJ Tsr.iepis - Coating Specialist (corrected copy of Resume submitted in ALAB Report #33)

C.

Quality Assurance qualifications of supervisors and engineers listed in B above are attached to this report.

D.

Changes The following personnel no longer are performing quality-related tasks at the site:

1.

Midland Project Quality Assurance R Davis - Civil IE&TV E Jones - Electrical IE&TV G Kasparek-Civil QAE P Metcalf.- Fluids / Mechanical IE&TV 2,

Bechtel Quality Assurance / Quality Control N Ainsworth - Quality Control Electrical C Coy - Quality Control Electrical i

J Cruz - Quality Control Mechanical / Piping i

l K Deitz - Quality Control Mechanical / Piping S Gilnett - Quality Control Civil P Lahott - Quality Assurance R Murdock - Quality Control Civil J Musser - Quality Control Civil i

r U

5 2.

Bechtel Quality Assurance / Quality Control (Cont'd)'

J Rheinhardt - Quality Control Mechanical / Piping S Smith - Quality Control Electrical C Spinks - Quality Control Electrical 3.

B&W Construction Company Attachment B shows the present B&W Q.C. organization at the Midland site.

Further additions and deletions to the list of personnel with quality-related duties will be noted in the next quarterly report.

4 l.

l l

1.

t h

ATTACHMENT A QUARTERLY REPORT JULY 1981 THROUGH SEPTEMER 1981 PROJECT WORK SCHEDULE 1.

Complete the installation of missile shielding on the Auxiliary Building roof.

2.

Continue the installation of piping, hangers, and raceway throughout the Auxiliary Building.

3.

Start fire-proofing in the Control Access Area of the Auxiliary Building.

4 Complete hydro for the new and spent fuel pools in the Auxiliary Building.

5 Complete fuel pool steel and concr *te work in Containment 2.

6 Complete fuel handling mast and upending cars in Containment 1 & 2.

7.

Complete reactor vessel closure head less head set in Containment 1 & 2.

8 Complete motor tubes and stator for CRDM's in Containments 1 & 2 9.

Continue the installation of piping, hangers, and raceway in Containments 1 & 2

10. Start fire-proofing in Turbine 1 & 2
11. Continue the installation of piping, hangers, and raceway throughout the Turbine Building.

12 Complete fire-proofing in the Evaporator.

13 Complete HVAC in the Evaporator.

14 Continue installation of piping, hangers, and raceway throughout the Evaporator Building.

15 Complete Dow Pumphouse superstructure, i

16 Complete Condensate, steam pipe, and bridges.

(

17.

Initiate valve pit surcharge.

18 j

Complete large pipe installation in the Diesel Generator Building.

l

19. Complete Guardhouse superstructure and continue piping, hanger, and raceway installation.
20. complete Calibration Facility superstructure.

21. Continue piping and raceway in the Calibration Facility.

22 Start Unit 1 Transformer Deluge System.

k

QUARTERLY REPORT PROJECT WORK SCHEDULE JULY - SEPTEMBER 1981 PAGE 2

23. Complete small pipe and hangers in the Circ Service Water Building.

24 Start Pond Blowdown Facility.

i 4

1 r

I f-l l

1

(

>h gy E

n V

na I S av TT i o AN cn RA oo TT D D SS I I t

NS JR I S i

MA D

i S

A 1 2 i

1 1

J O

R l

U N

A.

l

)

l l

M R

dn a

O V

n l

S P

l a

zl I

c U

T E

mt n e l

V e

S s

V l

N t t el A

R b

i P

e N

s ol C E

l v

U w

O a c a c u

C.

d S

ESCM a

S lu a

D a

R S

T Q

E e

E N

D r

P DRRH T

H T

O C.

S T

E S

D

,Q S

R I

T A

H 1 234 A

Z I

N A,.

G R

O-C Q.,

i t

l t

E l a N

rl r V

H ne on P

n O

ek ri e U

w S

wo r e n S

o R

ooal a r

E BB CKK B

P P

S CVKAT N

R P

I S

N I

1 2345

S MIDI.AND PROJECT QUALITY ASSURANCE 1

e i

I

Attechmint to ALAB-106 Quarterly Raport Quality Personnel Resume Organization:

MPQA Name:

AGERTER, William (last)

(first)

(I)

Date:

6/8/81 m

Education:

1943-1947:

Central High School, Lima, Ohio 1947-1951:

U.S. Merchant Marine Academy, Kings Point, New York, Marine Transpurtation other:

Miami University, Oxford, Ohio, Math, History Other:

University of Pittsburgh, Graduate School, Pittsburgh, PA Management Program for Executives Work Histopr:

12/76 - 06/81: Project Assistance Corporation, Vice-President and Chairman of the Board of Directors 100 N. Winchester Blvd.

Suite 260 San Jose, California 95135 Direct the business affairs of the company.

Provide consulting services to utilities, architect engineers,,

and' other clients in the design, construction and operation of nuclear and fossil fired power plants.

03/73 - 12/76: Nuclear Services Corporation, QA Manager and Senior QA Tgineer 1700 Dell Avenue Campbell, CA 95125 Direct the efforts of the companies Quality Assur-ance Department.

Provide consulting assistance in QA to utilities, architect engineers and other clients.

02/62 - 03/73: General Dynamics, Chief of Quality Engineering, Chief of Quality Audits, Chief of Procurement QC, Chief Inspector, QA Engineer Electric Boat Division l

Eastern Point Road l

Groton, Conn. 06320 Direct and manage Quality Assurance efforts related to the reactor and associated systems in nuclear powered submarines during their construction, overhaul and refueling.

l 02/55 - 02/62: Westinghouse Electric Corporation, Field Engineer Wall Street New York, New York Direct the installation, overhaul and repair of both stationary and marine power plant equipment, primarily turbines and generators.

l l

Attachment to ALAB-106 Quarterly Report Quality Personnel Resume Page 2 William Agerter 02/53 - 02/55: U.S. Navv, Lieutenant Ships officer.

03/52 - 09/52: Ore Steamship company, Third mate Baltimore, MD Ships officer ~ S.S.

Santore 1

l t

Attrchment to ALAB-106 Quartsrly R;p3rt Quality Personnel Resume Organization:

MPQAD Name: ANDERSON. C ema (last)

(first)

(11 Date: 4/27/81 Education:

1974-1974: Mariner High School, hhite Bear Lake, Minnesota 1975-1977: 916 Vo-Tech Institute, hhite Bear Lake, Minnesota, Quality Control Certificate Work History:

04/79 - 04/81: Yankee Atomic Electric Cortpany, Associate Engineer 1671 Worcester Pd.

Framminghan, MA In-plant audits for Maine Yankee, Vernent Yankee, and Yankee Rowe.

Provide QA coverage for refueling outages. Verxior evaluations.

Vendor surveillances. Provided QA coverage for W 'Ibrus modification.

Procurement document reviews. Design change reviews. Provide QA-coverage for spent fuel nodule fabrication (W, W, YR & Pilgrim I).

Print reviews. Nonconformance reviews. Maintain welder qualificatioris for the operating plants and NEPS Co. welders.

05/78 - 04/79: Progranmed & Remote Systems Corp., Quality Assurance Engineer 3460 N. Lexington Ave.

St. Paul, Minnesota In-house audits. Project audits. Vendor surveillances. Procure-ment document reviews. Customer interface & specification review.

12/76 - 05/78: Programmed & Renote Systems Corp., Inspector 3460 N. Iexington Ave.

St. Paul, Minnesota Welding inspection. Receipt inspection. In-process inspection.

Final inspection. bbnthly calibration of inspection tools.

Attrchment to ALAB-106 Qui:rtsrly R:psrt Quality Personnel Resume Organization:

HVAC QA/OC Name:

nnc:RY, John (last)

(first)

(I)

Date:

5/4/81 Education:

1966-1970: Westbury High School, Houston Texas UTHER:

Cona#Ccmbustion Engr./ Brown & Root-ASbE/NDP, Welding Courses

~

Certifications-Ur II, Mr II, Pr II, Visual II, RP I, Mech / Fab II Weri History:

01/81 - 05/81:

C.L.E.O., Inc., QA-Oc Inspector 3250 W. Big Beever Troy, Michigan Performing visual inspections of HVIC Systems. Verifying materials work are in accordance with applicable codes.

10/80 - 12/80: Lehigh Design, Welding Inspector P.O. Box 883 Idaho Falls, Idaho Vendor surveillance - Responsible for material control, fabrication and incpection of an oxygen vapor system for Dept. of Energy.

'.:/80 - 10/80: Brown & Root, Comanche Peak Pwr. Station, QC Inspector Glen Rose, TX NDP inspection - Responsible for inspection, fabrication, and documentation of Class I Piping Systems utilizing UT, MP, PT, VT.

l 05/77 - 02/80: Sonic Systems, NDr Technician l

Houston, TX Performed Inservice /Preservice inspections at various nuclear plants in U.S. and abroad.

12/74 - 05/76: Southwestern Iaboratories, QC NDP Technician Houston, TX Performed as Iavel II on various rield and shop assignments. Exten-sive Utrasonic work per ASSE, AN3, ASIM, ABS and Naviship's.

06/74 - 12/74:

Inspection Engineers, NDT Technician Houston, TX Vendor surveillance - Performed as Invel II (VP, MP, PT) and Level I RT on various field assignments.

l

Attachment to AIAB-106 Currterly Report Quality Personnel Resume Page 2

' John Busby 01/74 - 05B4: Fischbach-Onan,' Welding Inspector Kajakai, Afghanistan NDT - Responsible for the inspection, repair and documentation of the penstock piping and the turbine spiral cases on the Kajakai Hydro-electric Plant. Supervised 6 men.

03M 3 - 12B3: Conbustion Engineering, Ultrasonic Technician Chattanooga, 'IN Performed as Ievel II in the vald, plate and layout inspection of various nuclear pressure vessels, steam generators and pressurizers as per ASME code.

08/70 - 02M 3: Conam Inspection, NDT Technician Houston, TX Performed ultrasonic inspection of Pratt-hhitney Aircraft turbine parts utilizing imnersion technique. Worked in various refineries conducting on stream corrosion surveys of piping systems and storage tanks. Also performed as Ievel I Radio grapher.

.-=

ei A

-g*++-.--+

E

+-

,42-

.-m+

e

__Am a

, l av Attachn nt to ALAB-106 Quarterly Report Quality Personnel. Resume.

i.

Organization:

MPQAD Name: BUTTERFIELD, Mark C (last)

(first)

(I)

Date:

3/17/81

-Education:

1968-1972: Bay City Central High School, Bay City, Michigan 1972-1976: University of Michigan, Ann Arbor, Michigan - BS Civil Engineering Work History:

06/76 - 02/81: Ayres, Lewis, Norris & Nhy, Inc., Assistant Engineer Consulting Engineers & Architects Ann Arbor, Michigan Provided resident inspection on various municipal projects, both water and wastewater treatment plants. Performed various engineering tasks, ie, density tests, concrete spe-ciman preparation, survey work and field reports. Also, some contract administration and drafting.

05/75 - 08/75: Hazelett & Erdal Consulting Engineers (summer employment) 05/74 - 08/74 Commerce Building Louisville, Kentucky Performed inspection work on basculo span bridge and approaches.

08/74 - 04/75: Univerisity of Michigan, Assistant

'08/73 - 04/74 Engineering Department 08/72 - 04/73. Ann Arbor, Michigan Assisted Ph.D. candidates in making and testing concrete specimens for earthquake Jamage and rehabilitation.

q

-n w -

  • ys

--e.----e g-

-,gy

---w.,w--,,----, -,,- -,ve n~w.,,e,m,n.,n,n,.-w,.,a.,.m,-n,,._-n,n,,,,

v Attrchment to ALAB-106 Qu rtarly R prert Quality Personnel Resume Organization:

MPQAD Name: CURLAND, Marvin (last)

(first)

(I)

Date: 5/19/81 Education:

Mr. Curland attended Texas A & M and earned a B.S. degree with Distinction in Mechanical Engineering frm the University of Connecticut. He cmpleted graduate level courses in Nuclear Engineering, Mathematics, and Management. He is a Registered Professional Engineer; a Certified Quality Engineer; a senior member of the Americar.

Socieyt for Quality Control; a menber of the American Society of Mechanical Engineers and American Society for Nondestructive Testing.

Work History:

Mr. Curland brings over 30 years of business and industrial experience to Project Assistance Corporation.

Prior to 1951 he was engaged primarily as a fuels engineer in international marketing and transportation of coals and coke.

From 1951 through 1973, Mr. Curland successfully conpleted a broad spectrum of tech-nical, administrative and management assignments in the business of designing and constructing nuclear powered submarines. Starting as a Junior Engineer in the Electrical Design Department of General Dynamics / Electric Boat Division, his path of increasing responsibility included Supervisor of Nuclear Project Control, chief reactor plant test engineer, nuclear project manager, nuclear quality manager, Director of Management Engineering, Deputy Director of Operations, and Trident prototype site Program Manager.

In 1974, Mr. Curland was called on to make yet another breakthrough in management of a high technology area. Pronoted to the General Dynamics Corporate Office, he developed the first evaluation and analysis techniques for measuring the performance of their Data System.

Since 1974 he has provided Quality Assurance and Management Consulting Services to industry with a primary focus in the electric power generation area.

Typical significant acconplishments in Mr. Curland's career to date are:

-Developed and conducted Quality Engineering training courses at the University of Sae Paula, Brazil and in the USA.

-Developed and inplemented quality and output performance indicators for a net-Wors of data system service centers.

-Developed the shipbuilder's power plant test program and procedures for the first nuclear submarine and subsequent S5W reactor plant equipped ships.

-Established and directed the inplementation of a shipbuilders total quality assurance program for procurement, construction and test of 20 nuclear plants.

Attachment to AIAB-106 Quart:rly Report Quality Personnel Resume E1l396ifiCurland

-Organized the project and provided overall direction as General Contractor for construction of a nuclear plant and facilities under Naval, NRC, and ASME requirements.

-Developed quality programs for w:t ifacturers, fabricators, and suppliers to obtain ASME Code certification.

-Managed consolidation of multiple h ta processing organizations and facilities into one system with inproved perfonnance and audited savings of millions.

-Established and inplemented successful advanced management development, pro-ductivity inprovement and industrial engineering methods in a high technology, labor intensive, heavy construction industry.

-Developed and inplemented techniques or " vehicles" for ensuring that an alert work force (technical and craft) is maintained.

l l

,., +

Attechncnt to ALAB-106 Qu rtsrly Riport Quality PerJonnel Resume Organization:

MPOAD Name: DAVIS, Ibbert D.

(last)

(first)

(I)

Date: 3/5/81 Education:

1965-1969: " Monroe High School, bbnroe, Michigan 1969-1970:

Ferris State College, Big Rapids, Michigan, Heavy Equipnent and Diesel Repair, (Completed 1 year of 2 year course) 1971-1973: Navy Nuclear Power Schools Work History:

04/80 - 02/81: Newport News Reactor Services, QC Inspector Idaho Falls, ID NDT Ievel II IAW Navships 250-1500-1 (bff, PT, RT, UT); Reactor refueling and plant support Quality Control surveillare.

04/71 - 04/80:

U.S. Navy, Nuclear Propulsion Plant Operator, Ship's Emergency Welder / Ships Senior Machinist /QC Inspector / Engine Rom Supervisor Performed as qualified nuclear pipe welder; involved in fabrication /

refurbishment of machinery parts; WIIevel II in accordance with IAW Navships '50-1500-1 (bfr, PT, RP);, plant maintenance QC surveillance; Ur IAW MIL-STD-271E.

J 4

y w

.-.n n

r a

Attachment to ALAB-106 Qunrterly Rspart Quality Personnel Resume Organization: MPQAD Name:_ DECKER, John R.

(last)

(first)

(I)

Dat.e : 4/2/81 Education-1961-l % 5: ' Washington & Lee, Arlington, VA Other:

Georgetown University, W::shington, D.C., Business Adninistration Work Histo n:

03/77 - 03/81: General Electric Co. A.S.B.D., N.D.T. Spacialist 5035 Peachtree Ind. Blvd.

Cliamblee, Georgia 30341 Ievel III for I.S.I., P.S.I. and Vessel modification, training and certification on NDP Level I & II personnel. NDT Ievel III for the southern region ASBD 12/74 - 03/77: Nuclear Energy Services, Field Supervisor Conam Insp. 5391 Otto Avenue Rosemont, Illinois NDT Level II in RT, UT, MP, PT. Supervisor at various J.S.T. inspec-tion and other field locations.

04/71 - 11/74: Midstate 'Ibsting Lab, Production Manager 3846 Indianapolis Blvd.

East Chicago, Indiana Level II in RT, UT, MP, and PT.

Supervision of field activities at midstate certification and training of NDP personnel.

,e c

mw e

v-~

+,

et ---

Attachmint to ALAB-106 Qunrtsrly Rsport Quality Personnel Resu=e Organization:

HVAC/QA Name: DITTENBIR John K.

(last)

(first)

(I)

Date: 5/5/81 Education:

1970-1974: Midland High School, Midland, Michigan Other:

Dow Chemical Welding Celter, Midland, Michigan, Welding Certification in accordance with the ASNE code.

Delta University Center, Auburn, Michigan, Industrial Blueptint Reading Work History:

11/80 - 05/81: Zack Cmpany, lead Quality Control Inspector, Ievel II Midland, Michigan Supervised staff of 11 Level I/II inspectors. Provided training to QC trainees and CC Inspectors level I/II. Assigned, evaluated and approved inspection reports. Coordinated with the general con-tractor and utility in all aspecrs of Quality Control.

01/80.- 11/80: Zack Cmpany, Quality Control Inspector,rievel I Midland, Michigan Provided inspection on HVAC equipment, hangers, and ducts in relation with procedures, drawings and contract requirements. Visual in-spection of weldments to contract requirerrents.

04/79 - 11/79: Valley Welding & Boiler, Fitter 1533 Water St.

Bay City, Michigan Fabricated gear boxes, autonotive equipment in conpliance with blue-prints and specifications. Welding experience in SMAW and MIG.

10/78 - 02/79: 'Ihree Rivers Construction, Welder and Fitter 3405 E. Wackerly j

Mi'dland, Michigan Pipefitting and welding in accordance with manufacturer's bluep.rints.

Welder certified in accordance with ASbE Pressure Vessel Codel 02/78 - 10/78: Amtel Construction, Welder and Fitter l

110 N. Market Wichita, KA Fitter / Welder for industrial (oil and chemical) plants during shut-downs. Repaired pipes, set pumps and performed general maintenance i

work.

l l

07/76 - 05/77: bbndy Construction Co., Welder Houston, 'IX Fabrication shop, fitting schedule 40 and 80 pipe (2" - 8").

Welder certified in accordance with ASbE Pressure Vessel Code.

t

Attachment to AI.AB-106 Quarterly Report Quality Personnel Resure Organization:

MPQAD Name:

DOIG, William A.

(last)

(first)

(I).

Date:

3/25/81 Education:

1961 - 1964,Menphis High School, Memphis, Michigan 1964 - 1965 Hillsdale College, Hillsdale, Michigan 1 % 5 - 1969 US Naval Academy, ~ B.S. Chemistry Work History:

j 08/77 - 03/81 GK Truck & Coach Division Pontiac, Michigan -

03/80 - 03/81 Superintendent., Quality Control, medium duty trucks - Responsible for all quality areas of two product lines and several sub-assenbly areas. Directly supervised 2 general supervisors, 2 quality en-gineers,10 supervisors and an hourly work force of 225 line and receiving inspectors. Responsible for all daily quality product line decisions, development of product quality programs, adminis-tration of budget and purchase of departmental equipnent.

12/78 - 03/80 General Supervisor, Quality Control, heavy duty trucks - Responsible for overall quality of one product line. Supervised 5 salaried supervisors and a work force of 100 line inspectors. Duties in-cluded development of quality plans and standards for the product line, review and write department inspection procedures, administer consistent labor _ relations policy and control both direct and in-direct labor budgets.

i 08/77 - 12/78 Supervisor, Quality Control, heavy duty trucks - Directly supervised 20 to 30 hovely line inspectors. Duties included enployee procedure training, investigation and research of line quality problems, first level administration of the local labor agreement and to carry out health and safety training requirements.

06/69 -- 09/77 US Marine Corps, pilot Flew jet aircraft; additional duties included work as Avionics Officer, QA Officer, Safety Officer and Line Division Officer.

Attcchm:nt to ALAB-106 Quartcrly Rsport Quality Personnel Resume Organization:

MPQAD Name: FRANCIS, Arthur E.

(last)

(first)

(I)

Date: 5/19/81 Education:

Mr. Francis has a B.S. Degree in Mechanical Engineering from Stevens Institute of Technology and M.S. Degrees.in Naval Construction and Engineering and in Nuclear Physics'from M.I.T.~ He coupleted the Harvard Business School Advanced Management Program. He is a certified Iead Aeditor in accordance with ANSI /ASME N45.2.23 require-ments. He was also awarded the honorary degree of Doctor of Engineering by Stevens Institute of Technology for his significant contribution to the naval nuclear pro-pulsion program.

[

Work History:

c d

Mr. Francis has' extensive experience in design, construction, testing, overhaul and i:

refueling of nuclear power plants. He retired from a twenty-seven year' Engineering Duty naval officer career in 1%8 and was a Civil Service' employee with the Naval l

Reactors Division of the U.S. Department of Energy (DOE, formerly AEC) for the next eleven years. - He has been directly associated with naval submarine nuclear propulsion plants for the last twenty-nine years. Among his many acconplishments, s.

j Mr. Francis:

1 i

-Represented DOE on nuclear submarine' power plant engineering and design work i'

-(primarily Trident missile subnarine) ~at Electric Boar Shipyard.

4 i

-Formally monitored, for DOF/ Navy, nuclear propulsion plants in comissioned submarines noored in Groton, CT area fur adherence to nuclear reactor plant safety requirements and good engineering practices.

7

[

-Coordinated program among shipyard, Naval Sea _ Systems Comand, Navy Forces 1

Afloat and'oth

-effectiveness,er production support activities to ensure maximum operational and readiness of U.S. Navy nuclear powered deep submergence research ship NR-1.

-Assisted with establishment and initial operation of Electric Boat satelite structural manufacturing facility at Quonset Point, RI.

/.

-bbnitored contractor performance at Knolls Atomic Power Laboratory, Schenec-tady, NY, on design and development of nuclear propulsion plants for naval ships and AEC sponsored land based prototypes.

-Supervised, as.first Nuclear Power Superintendent, establishment of capabi-4

'lity at Pearl Harbor Naval Shipyard for overhauling and refueling nuclear submarines - Supervised initial nuclear subnarine overhaul / refueling.

-SJpervised AEC/ Navy responsibility for installation, testing, overhaul, refuel-

'ing and conversion of. nuclear propulsion plants in submarines at Electric Boar - Developed formal program and written procedures for joint participation of different activities required for testing submarine nuclear propulsion plants '- Was on-board technical representative during initial sea trials of early nuclear submarines.-

l

---, _ _ ~

_.,_.e,,,_.._,...,__,,.....____._._..

Attachment to AIAB-106 Quarterly Report Qualitf Personnel Resune Page 2 Arthur E. Francis

-Was AEC/ Navy Headquarters Project Officer for power plants in first nuclear sutmarines, Nautilus and Seawolf and their land based prototypes - Represented AEC/ Navy in connection with first reactor refuelings for Nautilus and its land based prototype.

-Has had hands-on experience in the areas of Water Chemistry, Radiological Controls, Metallurgy and Administrative Controls.

'e s

/

h

Attachment to ALAB-106 Qusrtsrly Rsport Quality Personnel Resume Organization:

MPQAD Name: mrriqTRTN. Donald A.

(last)

(first)

(I)

Date: 5/19/81 Education:

Dr. Goldstein has a B.B.A. from C.C.N.Y. and an M.S. and Ph.D from Penn State. He has over 50 publications in quality assurance, human factors, industrial engt eering and management topics; and presented numerous talks on these subjects. He it, a member of APA, AMA, and AIIE.

Work History:

Vice-President,' Executive Consultant of Project Assistarce Corporation

-Dr. Goldstein brings over 20 years of technical and managerial experience to Project Assistance Corporation.

Starting as a human factors engineer with the Electric Boat Division of General Dynamics Corporation-in 1%0,' he later served as Project Manager for EBM Ship Control Simulation Studies, Staff Engineer-in' Quality Assurance, Manager of the Int.ernal Management Consulting Group, and Director of Industrial Engineering. In 1976, Dr.

Goldstein left General Dynamics and for the next year was an' independent management

~

consultant to a variety of equipment manufacturers. 'Ihen in' 1977, he joined a large engineering consulting firm where he served as Director of Administration and client Staff Consultant. He also _ spent eight months as General Manager of 'a manufacturing and services subsidiary during the initial transition period following acquisition by the ccupany.

In January 1981, Dr. Goldstein joined PAC where he has technical and managerial

-. responsibility.for all general consulting functions including client management ser-vices, industrial. engineering, human factors; and training.

Among his nost noteworthy acconplishments to date, Dr. Goldstein has:

-developed and validated equipment configuration design criteria for sub-marine connand and control stations; and established feasibility of a visual alarm system for activation of emergency shipboard operations

-developed and validated aptitude. test battery for selection of inspectors and developed and implemented guidelines for visual surveillance, ultrasonic, and plan-reading training

. -developed and conducted numerous -training courses on planning, cost control, project and'line management

-performed systems analysis _ on project management activity for a major engineer-ing firm resulting in marked inprovement in cost and schedule performance.

-developed and helped implement productivity inprovement programs for various manufacturing and plant maintenance operations without use of incentives or conflicts with union

Attachment to ALAB-106 Quart:rly Report Quality Personnel Resume Page 2 Donald A. Goldstein

-developed plans and assisted management in inplementation or organizational changes to inprove performance and reduce costs of manufacturing, design engineering and material management functions

. -developed operating procedures to inprove schedule and quality performance at several diesel repair facilities of a major railroad; trained operating ard managenent personnel to facilitate acceptance and inplementation of these changes.

.--m-..~--

Attschment to ALAB-106 Qu;rtsrly Rxport Quality Personnel Resume Organization:

MPQAD Name: FCGRA?E, Howard E.

(last)

(first)

(I)

Date: 5/18/81 Education:

1932-1936: Hartford High School, Hartford, Conn.

1948-1950: Geneva' College, Beaver Falls, PA

~

Other:

Courses in QC Management, Quality Audit & Administration QA for the Nuclear Ibwer Industry Work History:

02/81 - 05/81: EES, Inc., Auditor Boston, Mass.

Assigned as auditor at Arkansas Nuclear One, Russellville, Ark.

Conducted audit / surveillance of site contractor activities during cutages of Unites 1 & 2.

11/79 - 2/81: Project Assistance Corp., Quality Control Inspection Planner San Jose, California Assigned as Quality Control Inspection Planner at Potomac Electric Power Co., Chalk Point Units 1, 2, 3, & 4.

Identified and preplanned all construction Q.C. inspection tasks and activities for plant construction, modification, and repairs. Scheduled all construction Q.C. inspection tasks and activities.

11/79 - 11/80

'Sr. Q.A. Engineer Assigned as Sr. Q.A. Engineer at Northern States Ibwer Co., Prarie Island Nuclear Generating Station. Performed internal audits, or-iginated and revised Administrative Control Directives and Section Work Instructions. Participated in the developement of the station Records Management Program and Document Control System.

01/70 - 07/79: 'Ihe Kerite Company, Q.A. Manager Seynour, Conn.

Assigned as Q.A. Manager. '/erformed a wide variety of quality assurance duties involving a knowledge of engineering and manu-facturing policies and procedures and their application to problems.

Developed product quality specifications and determined the probable effect of deviations. Made quality decisions within the limits of custaner specifications, and conpany policy. Prepared and super-vis(d the implementation related to the quality # unction. Had extensive outside contacts involving company po] tcy, confidential data, and proprietary test data and problems. ifad frequent inter-face with customers engineering persormel. Represented conpany by menbership in professional societies..nd on National Standards Committee.

-Attachment to AIAB-106 Quarterly Report Quality Personnel Resume Page 2 Howard E. McGrane 12/63 - 01/70: W e Kerite Conpany, Manager of Test & Inspection Dept.

Seynour, Conn.

' Assigned as' Manager, Test and Inspection Dept. Performed diver-sified duties as supervisor of the departsnent performing testing and inspection of insulated wire and cable. mis required a empre-hensive knowledge of electrical and physical testing and inspection of wire for the utility and railroad field. Supervised, trained, and instructed subordinates as to schedules, techniques, and standards of performance. Prepared procedures for test and inspec-

- tion activities.

10/66 - 12/63: Iewis Engineering Co., Foreman of Inspection Dept.

Wire Division Naugatuck, Conn.

Assigned as Foreman, Inspection Dept. Supervised inspection, testing, and laboratory testing of insulated wire and cable for aerospace and military applications. Specialized skills in the testing and calibration of thernmouple materials.

a l

~,

.+--~re e-e e,-

,,v

-,--r,~-

Attachm:nt to ALAB-106

-Qumrtarly Riport Quality Personnel Resume Organization:

HVAC/QA Name:

OBERMEYER, G. James (last)

(first)

(I)

Date:

5/13/81 Education:

1 % 8-1972: " Port Richnend High School, Staten Island, New York Other:

Staten Island Comnuni, Staten Island, New York

-.NDP Courses in Ultra-Westinghouse NSD Schoo, Staten Island, New York Krautkramer Branson Schools, Staten Island, New York smics, @ htrant, General Dynamic Schools, Staten Island, New York Magnetic Particle, Sonic Systems Schools, Staten Island, New York.

sul InsWm Work History:

11/80 - 02/81: Sonic Systems Int'l, NDE Technician, UT Level II, PT Level II, Mr Level I, VI Ievel II 9720 'Ibwn Park Houston, 'Ibxas 77036 Inservice and preservice inspection in various nuclear power plants in the U.S. and abroad.

08/80 - 11/80: Boddar NDT, NDE Tech., UT Ievel II P.O. Box 773 Dubai, United Arab Emirites Inspection of Structual components of off shore platforms.

09/78 - 08/80: Sonic Systems Int'l., same as above 07/78 - 09/78: Conam Inspection, NDP Tech., UT and RT 1385 Weatherspoon St.

Rahway, New Jersey Weld inspection in local fabrication shops and oil refineries.

04/78 - 07/78: Harris Steel, QA/QC Inspector 1640 New Market S. Plain Field, New Jersey Visual Inspection, paint inspection. Verified documents.

02/75'- 06/75: General Dynamics, NDr Tech., UT and RT 97 E..Howard St.

Quincy, Mass.

Weld inspection of LNG Tankers using ultrasonic and radiography.

p--,--

~m, e,

--seen-

a-Attachmint to ALAB-106 Quarterly Report Quality Personnel Resume Organization:

MPQAD Name: OSWOOD, Eric (last)

(first)

(I)

Date: 4/28/81 -

Education:

1961-1965:

Mn Marcos High School, San Marcos, California 1965-l % 7: Palomar College, San Marcos California, Technical Electronics, A.A.

U.S. Navy, EM ' A',

D1

'B', Instrtznent Controllers, Nuclear Power, Prototype, 3 M.

Work History:

08/80 - 04/81: Newport News Reactor Services, Mechanical Associate Engineer Idaho Falls, Idaho Followed plant support work, wrote turmvers. In charge of turnover inspections, wrote plant support procedures. Issued on he spot changes. Authored change requests and advanced plan revisions.

01/68 - 09/80:

U.S. Navy, Electricians Mate, Chief Petty Officer (E-7)

Leading Electrician (Sub/AIW prototype)

Train. Coordinator, Engineer-ing Officer of the Watch. Nuclear Instructor.

07/67 - 04/68: Commander Labs, Quality Control 'Ibch./Hydralic Press Operator Escondido, California Performed electronic and mechanical measurements on piezioelectric transducers. Fabricated transducer bodies.

I i

l I

i

Attachmint to A1.AB-106 Quarterly Report Quality Personnel Resume Organization: MPCAD Name: pFRRTNF. Marrv J.

(last)

(first)

(I)-

Date: 5/15/81 Education:

1956-1960:

, oodward High School, 'Ibledo, Ohio W

1960-1968: University of 'Ibledo, 'Ibledo, Ohio, BSEE Other:

Cleveland Institute of Electronics, Cleveland, Ohio, Electronics Work History:

08/80 - 04/81: Guardian Industries, Maintenance Supervisor Carleton, Michigan Supervised 15-20 maintenance personnel, Monitored work performed, Selected job priorities, Responsible for entire plant maintenance.

03/80 - 08/80: FC Iouth Steel, Electrical Maintenance Supervisor Gibralter, Michigan Supervised 15 crane operators and 8-12 electrical personnel. Trouble shot breakdowns, Responsible for entire plant electrically.

05/72 - 01/80: AbC Jeep, Senior Plant Electrical Engineer

'Ibledo, Ohio Responsible for entire plant electrically. Approved all new projects and nodifications to existing equipment. Design electrical circuits.

01/68 - 05/72: Owens Corning Fiberglas, Corporate Electrical Engineer

'Ibledo, Ohio Design, specify, and purchase materials for project installations.

Travel to plants and oversee project installations.

03/64 - 01/68: Dura Corp., Contract Engineer

'Ibledo, Ohio Tested and evaluated D.C. motors and regulators to Ford Motor Co.

specifications 02/62 - 03/64: Patton Detective Agency, Private Investigator Toledo, Ohio Suiveilance of people, plants, homes, etc.

Attichment to ALAB-106 Quartsrly R1 pert Quality Personnel Resume Organization:

MPCAD Name: SCHIAIFER, Arthur E.

(last)

(first)

(I)

Date: 5/14/81 Education:

1936-1940: Frirfax High School, Los Angeles, California 1942-1955: University of California, Berkeley, California - BS Civil Engineering (Intermittent) 1948-1 % 0:

U.C.L.A. Extension, Los Angeles, California (Intermittent) - Engineering Math, Business Administration 1969-1973: California State University, Ios Angeles, California (Intermittent) -

Civil Engineering, including Soil Mech.

Work History:

01/81 - 03/81: Boston B3ison Co., Nuclear Licensing Engineer 800 Boylston St.

Boston, MA Assisted in attacking a backlog of NBC commitments, including NUREGs, inspections', bulletins, notices, etc. Worked with project and task engrs. on Pilgrim I assignment.

03/78-12/80: Brown & Root, Inc., Nuclear Quality Assurance Engr., So. Texas Project.

P.O. Box 399 Bay' City, TX 77414 Established and followed up written QA program elements responding to 10 CFR 50 App B.

Developed inspection plans.

Participated in nonconformance resolutions. Was a QC inspector. Reviewed doc'ts.

06/73 - 04/77:

So. California Edison Co., Construction Mgt. Engr., QC Engineer, Nuclear QA Engineer P.O. Box 700 Rosemead, California 91770 Worked in Construction Mgt., QC, and QA departments. Responsible for OA of Civil & Structural activities at-San Onofre 2 & 3 jotsite.

l Preparation of QC Manual. Vendor pre-qualifications.

08/71 - 06/73: Advanced Foundation Engineering Co., Soils and Foundation Engineer Airport Way Iong Beach, California l

Responsible for foundation and soils analyses and investigation

(

reports. Consultant to clients. Directed field and lab work and coordinated the work.

l 12/70 - 03/71: Pacific Foundation Engineers, Inc., Soils & Foundation Engr. Trainee Riverside Blvd.

Bloomington, California Conducted lab and field investigatioru, performed analyses. Wrote l

some investigation reports.

l i

~. -

Attachssnt to ALAB-106 Quarterly Report Quality Personnel Resume Organization:

Bechtel Quality Control Name: KOZAK Rania11 J.

(last)

(first)

(I)

Date:

3/11/81 Education:

1960-1964 Bay City Central High School, Bay City, MI.

1964-1966 Delta College, Saginaw, MI. (Associates in Science -Math / Chemistry) 1966-1968 Central Michigan Univeristy, Mt. Pleasant, MI. (BS - Mathematics and Physics)

Detroit Insititue of Methods and Time Study Work History:

11/77-2/81 Ferro Manufacturing, Mt. Pleasant, MI.

Production Foreman Senior Assembly Supervisor dealing with construction for Ford Motor power seat tracks.

11/76-1/77 Clair Plastics, Inc., Clare, MI.

Manufacturing Manager Duties included planning and lay-outs of jobs, purchasing of special parts and expedition of finished products.

7/72-5/76 Essex Wire, Clare, MI.

Industrial Engineer / Quality Control Established methods and work habits of production personel.

Worked as chief inspection for two years in the construction and quality of finished auto wire assembly harnesses.

9/68-8/69 All Saints High School, Bay City, MI.

Math and Science Teacher Taught senior math and science courses along with drafting.

l

Atttchms..t to ALAB-106 Qutrtsrly Raport Quality Personnel Resume Organization:

Bechtel Quality Control Name:__gRCMARIK Donald (last)

(first)

(I)

Date:

5/5/81 1

Education:

1975 Churchill High School, Livonia, Michigan (College Prep)

May 1981 Univeesity of Michigan /

Dearborn,

Dearborn,

Michigan (Major-Electrical

  • Engineering)

Work History:

/C;

  • /10 Massey Ferguson, Inc., 12780 Levan Rd., Livonia, Michigan

~

Engineering Intetn Instrumentation design, set up and repair.

9/79 - 12/79 Massey Ferguson, Inc., 12780 Levan Rd., Livonia, Michigan Engineering Intern Laboratory testing and instrumentation design.

1/79 - 4/79, Massey Ferguson, Inc., 12780 Levan Rd., Livonia, Michigan Engineering Intern Field test technician: Monitored, documented and maintained a field endurance test.

5/78 - 8/78 Motor Wares, Inc.,

Dearborn Heights,

Michigan Driver Filling orders, restocking shelves, and delivering parts to auto parts storce.

5.77 - 8/77 Fisher Body, Inc., Plymouth Road, Livonia, Michigan Checker / Packer Packing automobile seats in boxes and assigning shipping labels.

Attachment to ALAB-106 Quarterly Raport Quality Personnel Resume

).

Organization: Bechtel Quality Control

'Name: KRUG.

Kenneth S.

(last)

(first)

(I)

Date:

5/4/81 Education:

Bad Axe High School, Bad Axe, MI. (General) 1974 Peerless Cement, Detroit, MI. (Concrete Testing / Certificate)

-Work History:

i 10/79-4/81 Soil & Materials, Inc., Bay City, MI.

Senior Technicial, Level II Various inspections on concrete, soil and steel in ene tri city area.

1/77-10/79 Bechtel Power Corp., Midland, MI.

Batch Plant Inspector / Level II Inspection of the batch plant and test lab surveillance at the-Midland Power Plant.

6/75-1/71 U.S. Testing, 1415 Park Avenue, Hoboken, NJ.

Lab. Tech. II, ANSI Level II l

Concrete &, steel inspector on San Onofre, CA. Power Plant.

7/74-6/75 Unemployed 6/73-7/74 Technical Services, Inc., E 11 Mile Rd., Detroit, MI.

QC Inspector, ANSI Level I Concrete and soil inspection.

J e

t m.

Attachment to ALAB-106 Quarterly Rsport Quality Personnel Resume Organization: Bechtel Ouality Control

'Name:

MARTIN.

Aline (last)

(first)

(1)

Date:

5/3/81 Education:

May 1965 Watson High School, Watson, AR. (Business Major)

May 1975 Cayuga County Community College, Auburn, NY. (Computer Science)

May 1980 Columbia Basin College, Pasco, WA. (Drafting) t Work Historv:

1/81-Preernt L. K. Comstock (Bechtel Power), Midland, MI.

Clerk As-built walk downs, document electrical support locations, update QC rollouts.

2/80-6/80 Fischbach/ Lord Electric, Purchasing Dept., Pasco, WA.

Clerk Sorting and reorganizing purchase order files.

9/78-3/79 Grunau Co., Auburn, NY.

Engineering Clerk Audit purchase orders and file drawings.

2/78-8/78 McGhee Sheet Metal, McGehee, AR.

Secretary / Clerk Genercl office duties for one girl office.

l I

i l

I 14

., _ ~ - -

Attachmtnt to ALAB-106 Quarterly Report Quality Personnel Resume Organization:

Bechtel Quality Control Name: MATTIOLI John (last)

(first)

(I)

Date:

4/23/81 Education:

1975 Weirton High School, Weirton, W. Va.

12/80 West Virginia Northern Community College, Weirton, W. Va.

(Industrial Supervision & Management)

University of Steubenville, Steubenville, Oh, (Business Administration)

Jefferson Technical Institute, Steubenville, Oh. (Related courses)

J Work History:

11/75-4/81 Towndend & Bottum, Inc., Shippingport, PA.

Material Control Coordinator Supervise cragts, review and analyze purchase orders, and tech-nical assistance.

3/74-11/75 Pinkerton Security, Bruce Mansfield, Plant, Shippingport, PA.

Guard Carry out administrative policies, and perform the necessary paperwork.

1/74-11/74 Weirt n Daily Times, Weirton, W. Va.

Compos 4ng Room Clerk Perform all duties necessary to publish a newspaper.

l l

n

Attachment to ALAB-106 Qucrterly Report Quality Personnel Resume Organization:

Bechtel Quality Control Name: McCorkle David (last)

(first)

(I)

Date:

5/11/81 Education:

Montville High School, Oakdate, CT. (Liberal Arts) t 4

" Work History:

9/79-9/80 L.K. Comstock, Richland, WA.

Field Engineer Supervise craft installing hangers. Retro-fit, redesign hangers.

6/79-9/79 Bechtel Power Corp., Midland, MI.

Pipe Designer / Draftsman Walkdown small bore pipe. Drafted redline drawings.

4/79-6/79 Commonwealth Edison, LaSalle, IL.

Pipe Support Draftsman Drafted and walked down hangers.

8/78-4/79 Daniel International, Monroe, MI.

Jr. Engineer Samil bore piping layouts, hanger loc ation and material take offs.

Final walkdowns.

l l

Attechment to ALAB-106 Qusrtarly Report Quality Personnel Resume Organization: Bechtel Quality Control

'Name: MC C0Y, Wanda (last)

(first)

(I)

Date:

5/8/81 Education:

1967-1970 Theodore Ahrens High School, Midland, KY.

1972 Alice Lloyd, Pippa Passes, KY.

(AA) 1977 University of Pittsburgh, PA. (Accounting - % yr.)

1978-1980 Saginaw Valley, Saginaw, MI. (Accounting - 1% yr.)

Work History:

1/77-12/78 Pie Tree, Inc., Rt. 19, Canonsburg, PA.

Admin. Assistant Procurement for product material. QA finished product and inventory control.

4/76-1/77 A. C. Dellovade, Inc., Rt. 19, Canonsburg, PA.

Admin. Assistanc Take offs on drawings; procurement siding & tools; assist in bid evaluation and site inspection.

1/72-11/73 So. Central Mech., Inc., Bordstown Rd., Louisvill, KY.

Warehousing & Supply Technician Inventory control, purchasing, side material control, and assist in bids.

9/69-6/70 Jones Apothecary, E. Parkway, Louisville, KY.

Clerical Clerical i

$5

6 Attcchment to ALAB-106 Qurrterly Raport Quality Personnel Resume

-Organization:

Bechtel Quality Control Name: MC GONICAL. Lcrry J.

(last)

(first)

(I)

Date:

3/16/81 Education:

1966-1970 Danville Community High School (College Prep) 1970-1972 Purdue University (AAS) (Hisc., short duration, courses taken on coatings, welding, and cadwelding inspections)

-Work Historv:

5/80-3/81

' Construction Engineering Consultants, Inc., Middletown, PA.

Civil Structural Lab Supervisor Testing of civil structural materials and civil structural inspection.

8/77-5/80' Townsend and Bottum, Inc., Ann Arbor, MI.

QC Engineer / Inspector Civil Lead civil structural inspector on projects in Pennsylvania and Michigan.

4/75-8/77 Peabody Testing Services, Byron, IL.

Civil Structural Lab Supervisor Testing of civil structural materials and civil structural inspection.

8/74-4/75 Ostrander Drilling, Decatur, GA.

Drilling Foreman Geotechnical drilling and coal exploration.

4/72-8/74 American Testing & Engineering.. Indianapolis, IN.

Inspector / Drilling Superindendent Civil structural inspection, geotechnical drilling and coal exploration.

4/70-4/72 Walter Land Contractors-Engineers, Danville, IN.

Technicial Civil structural inspection and surveying.

Attechment to ALAB-106 Quarterly Report Quality Personnel Resume Organization: Bechtel Quality Control Name: prpny, william (last)

(first)

(I)

Date:

5/13/81 Education:

1944 Arkadelphia High School, Arkadelphia, AR. (Major-Math)

-Work History:

3/65-5/81 Gilbert-commonwealth Assoc., 209 E. Washington, Jackson, MI.

Asst. Project Representative Assist project manager with his duties, perform field inspections on concrete, steel and electrical installations on EHV transmission lines.

Inspect concrete, make test:

slump, air, temperature and break.

Inspect steel: drawings, assembly and erection of structures.

Inspect installation of conductors on all types of EHV lines and substations from 138 kV to 500 kV.

l l

Attechment to ALAB-106 Qusrterly Rsport Quality Personnel Resume Organization:

Bechtel Quality Cont 91 Name: PETERSON.

Lund (last)

(first)

(I)

Date:

6/2/81 Education:

1932 Manual Arts, Los Angeles, CA. (College Prep) 1939 University of Southern California, Los Angeles, CA.

(Civil Engineer)

Work Historv:

2/79-2/81 Carl Walker & Assoc., 920 Davis Rd., Elgin, IL.

Engineering Inspector Inspection of post tensioning systems, concrete quality control placing and finishing. Also, inspection of associated trades involved in construction of turnkey post tensioned garages.

11/72-1/79 Inryco, Melrose Park, IL.

Superintendent Supervision of installation of post tensioning systems in nuclear and commercial work.

3/46-10/72 Various Contractors (Inc.) - Healitty Mid-Continent, Sumner Sollitt Co., Walsh Construction Co., all of Chicago, IL.

Superintendent Supervision of tur '.ey projects, varing in range of $100,000 to $10,000,000, plus.

O v

w e-

-,v.

-p-,

3 w

--e.-

Attcchment to ALAB-106 Qusrtarly Raport Quality Personnel Resume Organization: Bechtel Quality Control Name: REVICH.

Semyon (last)

(first)

(I)

Date:

4/8/81 Education:

1940-1949 Chepovichi High School, USSR 9/1949-9/1953 Electromechanical College, USSR (BSEE-Equivalent) 9/1963-6/1969 Polytechnical Institute, USSR (MSEE-Equivalent)

-Work History:

8/79-2/81 United Electric Motor Service, Inc., Detroit, MI.

Engineer, Production Supervisor Diagnostics, QC and test of the electromotors; responsible for the equipment and instruments; planning and startup shop at a new plant; solving technical problems within repair process; and drawing sketches, graphs, and schemes.

5/76-8/78 Industrial Project & Design Co., Vilnius, USSR Sr. Project Engineer Startup of new and reconstructed radioelectronic plants, test, quality control, solving technical-economical problems within moounting, revealing and elimination of defects in designing, correction of drawings; indistrial design and specification of new and reconstructed radioelectronic plants; plant layout, equipment arrangement, preparing assignment and instrumentation diagram for QC and instrumentation departments; research, design and project development of equipment for material handling sys-tem and workers stations at the different departments, decign, specification, checking of drawings and circuit dimensions, test, and startup.

9/53-4/67 Radioelectronic Plant, Vilnius, USSR l

Engineer Metrological and QC, testing, startup of radioelectronic appa-ratuses and devices; production management; production moder-nization and design, exploration and implantation of new product, control testing, revealing and elimination of defects in designing, correction of drawings; industrial engineering, solving technical-economical problems within production, in charge of in-coming technical documentation for manufacturing new devices.

~

l Attcchment to ALAB-106 Qusrterly Rspcrt Quality Personnel Resume Organization: Bechtel Quality Control Name: RIGONI.

Albert J.

(last)

(first)

(I)

Date:

4/7/81 Education:

1939-1943 Iron Mountain High Grad., Iron Mountain, MI.

1942 Sumner course NYA Radio Tech. School, Houghton Collete of Mining Engineering, Houghton, MI.

1943 Marine Corps communications and material schools.

Work History:

1980-1981 G-Commonwealth with So, Carolina Public Service Authority, Moncks Corners, S.C.

Transmission Construction Consultant Inspection of EHV transuission lines-deep caisson foundations, steel pole structures conductor stringing tensioning.

Consul-tant to in-house QC team.

1978-1979 Self-employed - Alaska Commercial Salmon Fishing Operation Uakutat AK.

1977-1978 G-Commonwealth with Cleveland Cliffs Iron Co., Ishpeming, MI.

Materials Coordinator - Transmission Inspector Material control and inspection of transmission lines and substations.

1976-1977 G-commonwealth with U.S. Army Corps of Engineers, Juneau, AK.

Conscruction Consultant

-Inspection and consultant - aerial construction of trans-mission line relocation.

1975-1976 G-Commonwealth with Bangladesh Water and Power Development Authority, Dacca, Bangladesh Construction Consultant Direct and inspect transmission projects with native labor, under AID loans.

1975-1975 G-Commonwealth with Edison Sault Electric Co.,

Sault St. Marie, MI.

Construction Inspector Inspection 138 kV submarine cables installation at Straits of Mackinac.

G-Commonwealth with U.S. Army Corps of Engineers, Juneau, AK, Clerk of Works, Consultant Survey of proposed transatssion line relocation.

Atttchment to ALAB-106 Qucrtarly Rsport Quality Personnel Resume Organization:

Bechtel Quality Control Name: RIGONI.

Albert J.

(last)

(first)

(I)

Date:

4/7/81 Education:

Work History:

(Continued) 1973-1974 G-Commonwealth with Detroit Edison, Detroit, MI.

Transmission Construction Inspector Inspection of deep caisson foundations and steel structures for 345 kV lines.

1972-1973 G-Co.mmonwealth with Consumers Power Co., Jackson, MI.

Construction Inspecter Inspection of 345 kV transmission lines.

1969-1971 G-Commonwealth with Turkish Electric Authority, Ankara, Turkey Consultant - Clerk of Works Consultant and direct Turkish staff or surveyors and inspectors for U.S. A.I.D. and world bank financed E.H.V. system.

1967-1969 G-Commonwealth with Consumers Power Co., Jackson, MI.

Materials, Receiving, Inspection & Inventory Control Inspector Material handling for 345 kV transmission projects.

1967-1967 G-Commonwealth, Jackson, MI. office Transmission design.

1965-1966 G-Commonwealth with Arkansas Power & Light, Little Rock, AR.

Transmission Construction Inspector Inspection of 500 kV transmission lines.

1964-1965 G-Commonwealth, Jackson, MI. office Transmission design.

3

, _~

At tachment to ALA3-106 Quarterly Raport Quality Personnel Resume Organization:

Bechtel Quality Control

-Name : SCHAUT.

Richard (last)

(first)

(I)

Date: 1/13/81 Education:

Holy Name High School, Escanaba, MI.

Univeristy of Michigan, Ann Arbor, MI. (Engineering /l yr.)

Wayne State University, Detroit, MI (Engineering /l yr.)

U.S. Navy, Nuclear Power School, Vallejo, CA.

U.S. Navy, Nuclear Power Plant Operations, West Milton, NY.

-Work History:

1/74-1/81 Townseud & Bottum, Inc., State Street, Ann Arbor, MI.

Pre-Op Engineer (General)

Test 7 startup systems and equipment at fossil fuel power plant general facilities.

Asst. Field Superintendent Erection of piping systems, insulation & lagging, hoppers on precipitator conversion project.

Night Shift Superintendent Maintainance on SO2 system as required on fossil fuel power general facility.

Quality Control Inspector Audit electrical contractor QC program. Weld inspection Level I LP eystem verification inspections, calibration of measureing & test equipment. Audits of company programs, and Class A mechanical inspector.

1971-1974 The Duquesne Light Company, Shippingport Atomic Power Station, Shippingport, PA.

Instructor / Plant Operator Attend 1 year refresher course in Nuclear Power Theory &

operation. Operation of nuclear power reactor and turbine plant.

Instructor for 1 year at the Duquerne Light Co.

school.

1964-1971 U.S. Navy, U.S. Naval Submarine Base, Groton, CT.

Machinists Mete 1st Class (SS)

Operate and maintain nuclear and non-nuclear systems on nuclear powered missile firing submarine. Lead engineering lab technician responsible for all chemistry and radiation control on the reactor coolant system, secondary steam plant, and all areas of the nuclear submarine.

Instructor-Train and qualify machinists mates in the operation and main-tenance of nuclear and non nuclear systems, equipment and theory. Train personnel in theory and practical aspects of reactor plant and steam plaat water chemistry control. Train personnel in theory and practical aspects of radiation monitoring.and control.

--s Attachment to ALAB-106 Qusrterly Raport t

Quality Personnel Resume Organization:

Bechtel Quality Control

'Name: VanDenBosch Richard J.

Ilast)

(first)

(I)

Date:

3/5/81 Education:

1970-1973 Midland High School, Midland, MI.

1973-1974 Naval Training Center, San Diego, CA. (Welding Tech.)

1976 Naval Training Center, San Diego, CA. (N.D.E. Tech.)

-Work Historv:

3/81-Present Bechtel Power Corp., Midland, MI.

Welding QC Engineer 3/80-2/81 Bechtel Power Corp., San Onofre, CA.

QC Welding Engineer Installed and repaired piping srstems, pressure vessels in accor-dance with ASME Section III NBBI, and VIII, and also installed and repaired structural steel in accordance with AWS Dl.1/all the above work also in accordance with Bechtel work plan procedures and Quality Control Instructicus.

1/77-11/79 United States Navy (USS Ajax - Repair Ship), San Diego, CA.

N.D.E. Inspector / Certified to SNT-TIA Level I & II Installed and repaired high pressure piping systems in accordance to Navy standards. Also, repaired work to ships hulls and internal structure in accordance with Navy standards.

2/74-12/76-United States Navy (USS Barbey - Destroyer Escort), San Diego, CA.

Welder and Fitter - Firefighter Fit up HP and LP piping systems / welder for non-code items, i

I

.m a

Actschment to ALA2-106 Quarterly Raport Quality Persorael Resume Organization:

Bechtel Ouality Control-Name: Wood.

Fred C.

(last)

(first)

(1)

Date:

5/20/81 Education:

.1979 Meridian High School, Meridian, ID.

1979-1980 Boise State University, Boise, ID. (Engineering /No degree) 1980-1981 Columbia Basin College, Pasco, WA. (Engineering /No degree)

Work History:

2/80-3/81 W.B.G., Richland, WA.

Jr. Engineer Responsible for large bore hanger retro-fit status reports.

As-built drafting, group consisted of writing work requests and review of documentation and drawings, and responsible for hanger status in put to computer printout.

t h.

A J

PROJECT MANAGEMENT OFFICE l

1 I

  • Corrected Copy Attachmont to ALAB-106 Quarterly Report Quality Personnel Resume NAME:

Tseleois Arthur

_t DATE:

2/18/81 (Last)

(First)

(I)

ORGANIZATION:

PROJECT MANAGEMENT OFFICE EMPLOYEE NO.:

N/A (COATING CONSULTA'rI)

EDUCATION:

1972 - 1974:

Parkway West Ares Technical School, Oakdale, PA - Graduated with a Certificate of..chievement in Research Laboratory Technoiogy.

1974 - 1976:

Pennsylvania State University, Beaver, PA Campus - Majoring in Chemistry.

1976 - 1978:

University of Pittsburgh - Majoring in Chemistry (Degree incomplete)

WORK HISTORY:

Prior to employment with KTA in August 1978, Mr Tselepsis worked as an Intermediate Laboratory Technician in the Coatings Division of Mobil Chemical Corporation (May 1976 to August 1978). This provided him with a substantial background in protective coatings.

As a KTA employee, Mr Tselepis has gained considerable experience in the inspection of coatings applied to nuclear and non-nuclear facilities as follows:

Nuclear:

August 197 8*- April 1979: Shoreham Nuclear Station, Wading River, NY Oct 1979 - Feb 1980: Beaver Valley Unit II, Shippingport, PA Feb 1980 (1 week): Enrico Fermi, Monroe, MI Feb 1980 - Present: Shoreham Nuclear Station, Wading River, NY Mr Arthur Tselepsis was certified at a Level II coatings inspection capability in accordance with ANSI N45.2.6 on October 5, 1979.

Non-Nuclear:

May - June 1979: Ormet Aluminum Co, Hannibal, OH June, Aug 1979: Standard Pipe, Pearny, NJ July 1979: Monroaville Park Tank, Monroeville, PA July 1979: Intercontinental Terminals Co, Houston, TX Aug - Sept 1979: Republic Steel, Cleveland, OH

  • This resume was originally submitted with the thirty-third AIAB-106 report covering the period April 1 through June 30, 1981 sent on March 31, 1981.
,,0.C. ORGANIZATION AT MIDLAND PROJECT SITE O.C. SUPERVISOR S. Taulbec E

J t

=

s i

4 ASST. Q.C. SUPV.

T. Davis INSP. SUPV.

NDE SUPV.

ADMINISTRATIVE ASSISTANTS R. Brown R. Treadwell 1.

J. Bocian

,2.

R. Donovan l

INSP. PERSOriNEL NDE PERSONNEL 1.

C. Bowen 1.

II. Eastman 2.

V. Ilooker 2.

R. Scott 3.

K. Carroll 3.

R. Calenz 4.

A. Kleinrath 4.

11. PicClelland 5.

T. Kane

~

OUARTERLY rep 0RT JULY 1981 THROUGH SEPTEMBER 1981 PROJECT WORK SCHEDULE 1.

Complete the installation of missile shielding on the Auxiliary Building noof.

2.

Continue the installation of piping, hangers, and raceway throughout the Auxiliary Building.

3 Start fire-proofing in the Control Access Area of the Auxiliary Building.

4 Complete hydro for the new and speat fu~el pools in the Auxiliary Building.

5 Complete fuel pool steel and cor crete work in Containment 2.

6 Complete fuel bandling mast and upending cars in Containment 1 & 2 7

Complete reactor vessel closure head less head set in Containmant 1 & 2.

8.

Complete motor tubes and stator for CRDM's in Containments 1 & 2.

9.

Continue the installation of piping, bangers, and raceway in Containments 1 & 2.

10 Start fire-proofing in Turbine 1 & 2.

11.

Continue the installation of piping, hangers, and raceway throughout the Turbine Building.

12. Complete fire-proofing 'in the Evaporator.

13 Complete HVAC in the Evaporator.

14.

Continue installation of piping, hangers, and raceway throughout the Evaporator Building.

15 Complete Dov Pumphouse superstructure.

~

16.

Complete Condensate, steam pipe, and bridges.

17. Start settlement test in the Tank Farm.

18 Complete large pipe installation in the Diesel Generator Building.

19.

Complete Guardhouse superstructure and continue piping, hanger, and raceway installation.

20. Complete Calibration Facility superstructure.

21 Complete piping and raceway in the Calibration Facility.

22 Start Unit 1 Trans former Deluge System.

6 l

L

i QUARTERLY REPORT PROJECT-WORK SCHEDULE r

. JULY - SEPTEMBER 1981 PAGE 2 4

i i

l

23.. Complete small pipe and hangers. in the Circ Service Water Building.

24 Start Powd Blowdow. Facility.

i i

I 4

4 i

i.

I e

J 9

f i

. *J

)

t 1

k i

i I

I i

P A

i

, - - -.. - -. ~ -

.. - - ~.

Attachment to AIAB-106 Quarterly Report Quality Personnel Resume Page 2 Arthur E. Schlaifer 07/69 - 09/70: Tridea Electronics, Structures Specialist 1818 Huntington Dr.

So. Paradena, CA 91030 Besponsible for conpliance with specifications and contractual requirements.

Analytic efforts were in the fields of stress, vibration, and heat transfer, design and product support.

07/65 - 06/69: ItDonnell Douglas Corp., Senior Engineer - Scientist Bolsa Avenue Huntington Beach, CA Responsible for structural analysis ead design support for aero-space and missile projects, including ground support items.

July - June 1963 - 1 % 5:

North American Aviation, Senior Structures Engineer 12214 Iakewood Blvd.

Downey, CA Eesponsible for structural analysis and design support for Apollo Project flight vehicles.

03/59 - 06/63: Aerojet General Corp., Senior Developnent Engineer P.O. Box 993 Azusa, CA Structural analysis of liquid propulsion flight vehicles and boost 3rs. Pressure vessel analysis. Project engineering for devel;pment of structural plastics components of solid propellant vehicles; proposal and developnent efforts for reinforced plastics flight structures and pressure vessels.

03/57 - 02/59: Minnesota Mining & Mfg. Co., Reinforced Plastics Div., Structures Research Engineer 1600 W. 135th St.

Gardena, CA Responsible for plastic laminate and sandwich construction develop-ment for radanes and other flight structural canponents. Analytic support of design and laboratory develognent work. Consultant to sales department.

01/47 - 02/57: State of California, Div. of Highways, Associate Highway Engineer 120 So. Spring St.

i Los Angeles, CA 90012 Engineering assignments in the planning, engineering and con-struction of major highway and freeway projects.

Attach cnt to ALAB-106 Qunrtcrly Rsport Quality Personnel Resure Or anization: HVAC QA/OC Name:__ m ITH. Johnny s

(last)

~(first)

(1)-

Date: 5/5/81 Education:

1964-1968: Surgoinsville High School, Surgoinsville, Tennessee 0.her:

lban State Comunity College, Harriman, Tennessee 1977:

Training and Technology, Oak Ridge, Tennessee, Nondestructive Testing Tennessee Valley Authority QA Training, Eartsville Nuclear Plant, Harts-i Werk E.istod lle, Tennessee, Magnetic Particle, Penettant, Testing, Visual Testing 4

02/81 - 05/81: Zack Co., QA/CC c/o Cleo Midland, Michigan Inspection of HVAC conponents 10/77 - 02/81: Tennessee Valley Aut:hority Watts Bar Nuclear Plant Spring City, Tennessee Phipps Bend Nuclear Plant Surgoinsville, Tennessee Engineering Aide, Welding Engineering Unite, QC Welding, Hanger Engineering Unit.

Performed Fr and PT as SNT-7C-IA Ievel II, Vt as TVA Level II, Welder and welding surveillance, maintained and operated welding material control center., Piping hanger inspection. Trained Level I' personnel. Cleared for unescorted access in a nuclear plant.

03/77 - 09/77: Training and Technology, Nondestructive testing.

l Oak Ridge, Tennessee l

12/76 - 03/77: Unenployed 03/74 - 12/76: Engineering Department, Engineering Aide City of Mansfield Mansfield, Ohio Assisted in Iand - Contruction surveys.

07/68 - 05/71:

U.S. Army, SSG

{

Airborn Infantry, Honorable Discharge i

06/64 - 07/68: Alex Armstrong, Engineering Aide l-Surgoinsville, Tennessee l

Assisted Civil Engineer in land and construction surveys.

(Par t-time during high school) l

Attachment to AIAB-106 Quarterly Report Quality Personnel Pesume Organization:

MPQAD Name: VERDEROSA, Michael A.

(last)

(first)

(I)

Date:

5/11/81 Education:

1963-1967:

Ebrdham Preparatory School, New York, New York 1967-1971:

Manhattan College, New York, New York, B.S.M.E.

1971-1972:

University of Illinois, Champaign, Illinois, M.S.N.E.

Work History:

09/80 -- 01/81:

Washington Public Power Supply System (WPPSS), Senior Quality Engineer, Richland, WA Reverification of Canpleted Safety Related Wrk (RCSW) Task Ebree-staff Engineer. Evaluate Task Ebrce findings. Implement QA pro-gram including personnel certification program to ANSI 45.2.6.

01/76 - 05/80:

Department of Energy (U.S. Gov't). Fast Flux Test Facility Project Office (FETFPO) Nuclear Engineer Richland, WA Review, evaluate, direct contractor activities related to design, construction, test, and operation of Fast Flux Test Facility.

09/75 - 01/76:

Department of Energy (U.S. Gov't), FETFPO Quality Assurance Liaison Richland, NA Audit contractor QA/QC program. Sole quality engineer in advance of government QA program.

09/74 - 09/75:

Westinghouse Hanford Co., Quality Assurance / Quality Cbntrol Engineer Richland, WA (Loan frcm D.O.E.)

Performed supplier audits.

nitored/ audited construction activities at FF"7 site. bbnitored/ audited fuel fabrication for FETF.

09/72 - 09/74:

Ar.:mic Energy Comission, Plant Systems Engineer Lashington, D.C.

bbnitored/ directed contractor efforts in design, fabrication and testing of fluid /:rechanical conponents (valves, pumps, etc.) for liquid metal fast breeder test facilities. Activities included reviev/ approval of contractor designs for such items.

y, x

-m..

u -. -.

--a-x--.

e t

4 9

b i

BECHTEL QUALITY ASSURANCE / CONTROL 4

I f

1 e

b l~._ ___.,.._ _.._,.-_. _._,...-._-._... _..._...._._.. _ -.. -..... _.,... -

Attachment to ALAB-106 Qusrterly Rsport

. Quality Personnel Resume Organization:

Bechtel Quality Control Name: Aubert Richard S.

(last)

(first)

(I)

Date:

April 1981 Education:

1976 Pioneer High School, Ann Arbor, MI.'(College Prep.)

1980 University of Michigan, Ann Arbor, MI.

(Mechanical Engineering BSE) i I-Work Hi1 tory:

7/80-8/80 U.S. Army Corp of Engineers, Detroit District Office, P.O. Box 1027 Detroit, MI.

Civil Engineering Technician Do';ies included surveying, water (river) flow measurement, data reduction and report writing. Extended periods of travel of ten required.

5/79-8/79 U.S. Army Corp. of Engineers, Detroit District Office,

-P.O. Box 1027, Detroit, MI.

Civil Engineering Technician j

Duties included surveying, river flow measurement, data reduction and report writing. Extended periods of travel often required.

5/78-9/78 U.S. Army Corp. of Engineers, Detroit District Office, i

P.O. Box 1027, Detroit, MI.

Civil Engineering Technicial Duties included surveying, river flow measurement, data reduction and report writing. Extended periods of travel often required.

i 7/77-8/77 U.S. Army Corp. of Engineers, Detroit District Office, P.O. Bxo 1027, Detroit, M1.

Engineering Aid Duties involved data reduction, and various office functions and odd jobs.

5/77-7/77 Sears, Roebuck & Co., Briarwood Circle, Ann Arbor, MI.

Automotive Stock Clerk Duties included pulling parts for the mechanics, charging batteries,

-inventory, maintenance, stocking sales floor, ordering parts, and arranging stock room.

t

4 Atttchment to ALAB-106 Qunrtcrly R: port Quality Personnel Resume 4

Organization:

Bechtel Quality Control Name: BERESTOVETSKY Leonid (last)

(first)

(I) 1 Date:

4/21/81 1

Education:

No. 25, Kiev, USSR i

Institute of Technology, Kiev, USSR Department of Civil Engineering (Civil and Industrial Construction)

Work History:

1973-1979 Main Directorate for Construction in the City, Kiev. USSR Head of the Central Welding Department Development and implementation of technological policy in the field of welding and assembly operation.

Q.C. of welded joints at construc-tion sites and in the laboratory.

Collection, processing and analysis of statistical data, decision-raking aimed at the improvement of welding and assembly operations.

1969-1973 Hain Directorate for Construction in the City, Kiev, USSR Chief of Construction on the " Cybernetics Center" project Management of general construction operations and coordination of subcontractor activities, planning, financial aspects, inspection estimates, accounting, reporting, Q.C.

1960-1969 Construction Company, Kiev, USSR Superintendent, Senior Engineer for Q.C., Section Chief Supervision of different workers teams:

Steel frameworks, concrete, welding and brick works, assembly pre-fabricated reinforced concrete structures.

Q.C. steel frameworks, concrete, welding and assembly works.

1955-1960 Main Directorate for Construction in the City, Kiev, USSR Foreman, Superintendent Supervision of different workers teams and its Q.C.

Receiving of subcontractor products, evaluation of their quality.

w

Attcchm:nt to ALAB-106 Quarterly Report Quality Personnel Resume Organization: Bechtel Quality Control Name: BERSCH Randall (last)

(first)

(I)

Date:

5/26/81 Education:

~

1973

.Preble High School, Green Bay, WI.

(Architectural Drawing) 1976 Fox Valley Technical Institute, Appleton, WI.

(Certified, Electricity -

Basic Electronics) 1981 Nortteast Technical, Green Bay, WI.

(Assoc., Welding Technology)

Work History:

5/73-9/80 C.B.T. Manufacturi.ng, 970 Hinkle Rd., Green Bay, WI.

Department Supervisor Hired as techanical laborer, trained through ranks to head department supervisor. Supervised crew of eight and was responsible for all phased of production. Considerable time spent on blueprint reading, layout and fabricating sheet metal, piping and working to close tolerances. Also, responsible for maintenance of clectronic instrumentation equipment used for production, infre-red conveyor dryers, auto-mark digital die stamp, and hix automated heat pro-cessor. No further advancement possible within company. Left to finish technical training.

l f

I l

I o

l l

l

f Attechment to ALAB-106 Quarterly Report qualit.; Personnel Resume 0;gani..;1cn:

Bechtel Quality Control lhttme : BLACK.

Jerry L.

(last)

(first)

(I)

Date:

5/11/81 Education:

Central High School, Red Wing, MN. (College Prep.)

1965-1966 Univeristy of Minnesota /Winona, Winona, MN. (Business Admin-instration, no degree) 1976 Hennepin Tech. Center, Brooklyn Park, MN. (Powder Metallurgy, Certificate of Completion)

Work History:

8/78-12/30 L. K. Comstock Field Engineer Supervise craft for installation of large bore hangers, retro-fit, and redesign.

1/78-8/78 ITT Meyer Ind.

Checker / Draftsman Assist research and development for design of Hi-Rise service car.

3/76-12/77 Cherne Contracting Field Engineer /QC Inspector Lead test man for hydro and flush tests of as-built hangers and pipe.

Inspected steam generators.

l 1/71-9/74 National Valve & Mfg. Co.

I Purchasing Agent Purchased office supplies, hand tools, weld rod, pipe, fittings, valves, and equipment.

l I

i l

l l

l i

t Attachment to ALAB-106 Quarterly Report Quality Personnel Resume J

n Organization:

Bechtel Ouality Control

'Name: BROWNELL.

James A.

(last)

(first)

(1)

Date:

5/4/81 Education:

4 6/73 Grosse Pointe So. High School, Crosse Pointe, MI. (College Prep) i 5/78 Michigan Technological University, Houghton, MI. (Electrical Engineering Technology, Electromechanical Engineering Technology, AAS/AAS)

-Work His torv:

10/80-Present Bechtel Power Corp., Midland, MI.

Field System Engineer / Mechanical Startup Systems Respor.sibilities include: installation and inspection of large pipe, large pipe hangere, small pipe, small pipe hangers, mechanical equipment; verification of proposed designs; f

"as-building" designs; modifying of proposed designs to agree with specifications and to avoid redesigns; preparing all documents for QC review; correcting any discrepancies within i

l specifications; preparing systems for hydrotest; design field routed non-safety /non-critical piping and hangers; coordina-i tion of designs with other disciplines; resolving engineering problems with the design group; preparing turnover packages for j

functional turnover to the client; preparing " mini" construc-tion schedules; inputing into job status printouts; red-lining isometrics to add or delete welds, reroute pipe and hangers to avoid interferences 1 verification of tracibility on safety related items; verification of proper weld identification on safety related systems; writing Field Change Requests; reworking systems to meet client change requests.

2/79-10/80 Bechtel Power Corp., Midland, MI.

t.

Field Test Engineer Construction flushing and testing, including writing of pro-cedures to meet ASME and ANSI code requirements. Conducting of pre-test and pre-flush meetings with all phases of construc-tion to assure successful operations. All testing and flushing procedures are presented to the client and QC/QA for approval.

[

All engineering problems encountered during the. operation are l

also resolved. Upon successful completion, a review is cond-ducted to assure all code and client requirements have been met.

i

\\

.~

_. -,.. _. -. -. -,, - ~, _ _. - - _ -.

Attcchment to ALAB-106 Qucrterly Rsport Quality Personnel Resume Organization: Bechtel Quality Control

~Name: CLARK.

Jeffrev P.

(last)

(first)

(I)

Date:

3/16/81 Education:

1972-1975 Henry Ford High School, Detroit, MI. (College Prep) 1975-1979 Michigan Technological University, Houghton, MI. (BSME)

Work History:

12/79-2/81 Eaton Corporation, Advanced Electronic Instrunentation Div.,

Troy, MI.

Project Ergineer Design and development of new products, solving on-line production problems.

6/78-9/78 Ford Motor Co.,

Dearborn,

MI.

Draftsman Detailed new products for production.

e

Attechment to ALA3-106 Qucrtarly Raport Quality Personnel Resume Organization: Bechtel Ouslity Control Name: Clark Robert (last)

(first)

(I)

Date:

5/7/81 Education:

Midland High School, Midland, MI. (College Prep)

Work History:

8/80-12/80 Self-Employed, 1016 Eastman, Midland, MI.

Contractor Remodeled house to meet city building codes.

5/78-2/80 U.S. Testing Co., Miller Road, Midland, MI.

Tech. II Testing of raw materials (steel, concrete, soil, etc.) to ASTM specifications /Bechtel specifications.

10/54-1/75 Dow Corning Corp., Midland, MI.

Lab. Tech. (Many varied jobs, but_this was only QC related)

Testing of silicone rubber to ASTM specifications.

10/50-8/54 U.S. Navy, Construction Battalion i

Surveyor /3rd Class Petty Officer Layout and inspection of construction products.

8/48-10/50 Michigan State Highway Dept., Lansing, MI.

Inspector Inspection and testing of raw materials and finished construction.

AttEchment to ALAB-106 Quartsely Rsport Quality Personnel Resume Organization:

Bechtel Quality Control Name: CROSS.

Charles W..

Jr.

(last)

(first)

(I)

Date:

4/7/81 Education:

1971-1975 Tonganoxie High School, Tonganoxie, KS. (College Prep) 1975-1977 University of Kansas, KS. (Civil Engineering)

+979 Fayetteville Technical College (Welding Technology - 15 wks.)

1980 Lincoln Electric Welding School (10 wks.)

-Work History:

8/80-4/81 Bechtel Power Corp., Midland, MI.

Electrician Welder Welding of electrical supports.

3/77-3/80 U.S. Army Light Weapons Specialist, Engineer Maintenance and deployment of weapons systems.

Supervised use of explosive demolitions.

I e

?

Attcchment to ALAB-106 Qucrtcrly Rapsrt Quality Personnel Resume Organization: Bechtel Ouality Control

~Name: nAMRifDY Dirhard (last)

(first)

(I)

Date:

4/20/81 Education:

Montgomery High School, Montgomery, W. VA.

2/64 Statistical Q.C., Aurora, IL. (1 Yr.)

Work History:

8/75-4/81 Shawano Paper Mill, Shawano, WI.

Machine Tender Assure proper information is in computer and that paper meets requirements.

8/73-6/78 Chuck-Wagon Restaurant Owner Management of small business.

5/68-8/83 Burgess-Norton Mfg., Geneva, IL.

Final Inspector First piece inspection, and final acceptance of parts for sale.

2/63-5/68 DK Aero-Space, Batavia, IL.

Quality Control Coordinator Assure compliance of company procedures.

Attcchment to ALAB-106 Qucrtsrly Report Quality Personnel Resume Organization:

Bechtel Quality Control Name: FEDOROW.

Wesily (last)

(first)

(I)

Date:

3/9/81 Education:

1965-1968 Coshen High School, Goshen, IN.

1968-1972 Tri-State University, Angola, IN. (B.S.E.E.)

Work Historv:

Background includes over 9 years of training and experience in electrical engineering for overhead distribution systems and power plant projects including lighting systems, conputerized raceway and circuit routing systems, and miscellaneous plant electric systems.

3/80-3/81 Gilbert / Commonwealth assigned to Pennsylvania Power Company's Bruce Mansfield Power Plant Associate Engineer Responsible for tne design and layout of various plant elec-trical systems. Duties include the preparation of wiring and layout of wiring and layout drawings, material requisitions and bills of materila; writing circuits; sizing of cable and conduit; and review of vendor drawings.

7/76-3/80 Gilbert / Commonwealth with Consumers Power Co., Jackson, MI.

Associate Engineer Responsible for design and layout of the in plant lighting systems'and administering the computerized circuit routing program for the 800 MW coal-fired J.H. Campbell Plant, Unit 3.

Responsibilities included preparation of lighting calculations and layouts, and the assembly, organization and input of all circuit and layout data for computer output of circuit lists, pull slips and other data sorts.

12/71-7/76 Inana & Michigan Electric Company, Ft. Wayne, IN.

Electrical Engineer Responsible for the design and layout of distribution lines involving the preparation of estimates and work orders, calculation of voltage drops and the sizing of cable and transformers as we.11 as the field checking of completed projects.

Attcchment to ALAB-106 Qu rterly Raport Quality Personnel Resume Organization:

Bechtel Quality Control Name:

Groat Charles (last)

(first)

(I)

Date:

5/13/81 Education:

Palatine High School, Palatine, IL.

(General)

-Work History:

1/80-4/80 Eechtel Power Corp., Palisades Nuclear Plant, South Haven, MI.

QCE/ Piping-Mechanical Testing and documentation of anchor bolts for installed pipe hangers.

7/76-1/80 Bechtel Power Corp., Midland, MI.

QCE/ Piping-Mechanical Testing, documentation, and inspection of piping, mechanical, welds and pipe supports being installed.

5/75-5/76 Roberts Automatic Products, St. Paul, MN.

Machinist Set up and operate Acme Gridley automatic screw machines.

5/74-5/75 McPhillips, Roofing, Red Wing, MN.

Roofer Repair roofs wich tar and gravel.

5/70-5/74 National Valve & Mfg. Co., Pittsburgh, PA.

QC Inspector Testing, documentation, and inspection of piping, mechanical, welds and pipe supports being installed.

5/68-5/70 Screw Products of America, South Gate, CA.

Machinist Set-up and operate Davenport automatic screw machines.

1/67-5/68 Yale Engineering, Downey, CA.

Machinist Trainee To learn to set up and operate Davenport automatic machines.

3/65-1/67 U.S. Post Office, Arlington Heights, IL.

Postman Deliver mail.

Attachment to ALAB-106 Quartsrly Rapsrt Quality Personnel Resume Organization:

Bechtel Quality Control

'Name: Groat Charles (last)

(first)

(1)

Date:

5/13/81 Education:

Work History:

(Continued) 7/63-3/65 Imperial Eastman Corp., Skokie, IL.

Machinist Trainee To learn to set up and operate new Britan automatic screw machines.

7/61-7/63 U.S. Naval Reserve, Glenview, IL.

Mechanic Repair and tune-up prop. engines.

l l

l l

i i

D5 Attcchrnt to ALAB-106 Quarterly Report Quality Personnel Resume Organization:

Bechtel Ouality Control Name: unhn rhnm.

(last)

(first)

(I)

Date:

4/21/81 Education:

. Boys Tech. & Trade, Milwaukee, WI. (Electrical Technology)

Maryland Extension, Maryland (Electrical Technology)

South Division High School, Milwaukee, WI. (General)

Work History:

9/79-Present Gilbert / Commonwealth, Jackson, MI.

Senior Construction Inspector Interpretation of specifications.

Inspection of assembly / erection of steel poles and towers.

Inspection of conductor installation.

5/78-9-79 Thompson Electric, Hibbing, Minnesota General Foreman Supervision of construction crews in distribution, sub-station construction, and live line relocation.

2/77-5/78 Gilbert / commonwealth, Jackson, MI.

Senior Construction Inspector Interpretation of specifications. Inspection of assembly, and l

erection of steel poles and towers.

Inspection of conductor l

installation.

i 1/77-2/77 Donovan Construction, St. Paul, MN.

Foreman Supervision of construction on distribution system construction.

3/76-1/77 Hoosier Engineering Co., Dublin, OH.

Foreman Supervision of construction on EHV and distribution and wire installation.

5/75-3/76 Midland Construction Company, Dodge Center, MN.

Foreman I

Supervision of Construction on EHV, distribution and wire installation.

i

h Attechuwnt to ALAB-106 Qu:rterly Raport Quality Personnel Resume Organization: Bechtel Quality control Name: "FMNNAH.

James (last)

(first)

(I)

Date:

6/10/81 Education:

1960 City Public S.S., Glasgow, Scotland (Tech. Drafting, Maths, English) 1962 Shawlands Academy, Glasgow, Scotland (Tech. Drafting) 1965 Strathclyde University, Glasgow, Scotland (Technical Drafting)

Work Historv:

2/80-3/81 Kaiser Engineers, Perry, OH.

Level III Piping & Mechanical Inspector HVAC inspector in complete charge of all 2nd line inspection, tests and system turnovers.

7/79-1/80 U.S. Testing Co., Hoboken, NJ.

Lead Inspector on Turbines at Shut-downs Mechanical Level III lead inspector on turbines at shut-downs in Calvery Cliff, Maryland, and Palisades, MI.

5/78-7/79 Wesmer & Becker, Newport, MI.

Repair & Test Engineer Turbine repair and testing, plus all auxiliary machinery related to power plant organization.

4/70-3/74 Texaco Oil Co., London, England Test & Control Repair Engineer Involved in repair and testing of all Texaco tankers, engineering and auxiliary machinery.

~

l Attcchment to ALAB-106 Quarterly Report Quality Personnel Resume Organization:

Bechtel Quality Control

__'Name: HAVRILCHAK William M.

(last)

(first)

(I)

Date:

5/4/81 Education:

1974 Mid-Valley High School, Olyphant, VA. (General Academic) 1976 Keystone Jr. College, La Plum, PA. (General Science /AA) 1978 Wilkes College, Wilkes Barre, PA. (Environmental & Earth Science /BA)

Work History:

4/79-4/81 Oliver B. Cannon & Son, 5600 Woodland Ave., Philadelphia, PA.

Level Il Nuclear Coating Inspector In process inspection, documentation, receiving and final inspection of nuclear coating systems, in accordance with project requirements and national standards. Experienced in supervision and surveillance of other inspectors, setting up test methods.

Interpretation of test data and documentation, inspection and receiving of coating materials. Evaluation and disposition of nonconformaning items; complete knowledge and understanding of calibration standards and test instruments; identification of coating defects and determining corrective actions.

l l

l l

i l

l

Attachment to ALAB-106 Quarterly Report Quality Personnel Resume Organization: Bechtel Ouality Control Name:

HAYES Robert E.

(last)

(first)

(1)

Date:

4/22/81 Education:

1949

.Luling High School, Luling, Texas 1950-51 University of Houston, Houston, Texas (Special courses in detail takeoff blueprints, welding) 1951-53 Houston Vocational College, Houston, Texas (Welding - Piping, Math Drafting)

Work History:

10/79-4/81 Bechtel, R&C Division, Houston, Texas Area Superintendant Responsible for the direction and execution of Area B, Convent Chemical Plant, through to mechanical completion.

Assistant Area Superintendant Assisted Area Superintendant in all duties and responsibilities.

Piping Superintendant Responsible for Piping and Welding 7/77-1/79 Sants Fe Int. (A P) Orange, California / Saudi Arabia Superintendant of Commissioning Responsible for all phases of commissioning through Startup.

Area Superintendant Responsible for direction and execution of craf t superintendants.

I Piping Superintendant Set up and maintained fabrication shop.

2/77-7/77

' Brown & Root, Houston, Texas Shop Superintendant Responsible for fabrication shop for the construction of a Petro-Chemical plant.

l-6/76-2/77 Pona Construction, Houston, Texas Area Superintendant Responsible for directi'on and execution of all phases of construction of eight pumping stations.

r

Attechment to ALAB-106 Qucrtsrly Rapsrt Quality Personnel Resume Organization: Bechtel Quality Control Name: HEIKKINEW Andrew C.

(last)

(first)

(I)

Date:

4/13/81 Education:

1974-1978 Baraga High School, Baraga, MI. (College Prep.)

1978-1979 Michigan Tech. University, Houghton, MI. (Diesel Mechanics / Certified) 1979-1981 Ferris State College, Big Rapids, MI. (Welding Technology /AAS)

Work History:

8/79-9/79 Turvunen Construction, Star Route, Pelkie, MI.

Labor Operated ground compactor, also operated mulcher seeding machine.

6/78-9/78 Pettibone Michigan Corp., Baraga, MI.

Mechanic Tearing down axles and salvaging resueable parts.

e

~

At tcchment to ALAB-106 Quartsrly Raport Quality Personnel Resume Organization: Bechtel Quality Control Name: HERBERT James (last)

(first)

(I)

Date:

6/2/81 Education:

1975 Rockford West Senior High School, Rockford, IL.

1975-1977 Bradley University, Peoria, IL. (Major / Electrical Engineering Tech.)

1979-1981 Wayne State University, Detroit, MI. (Major /Elec. Engineering Tech.)

-Work Historv:

5/80-11/80 Forest City, Cowan Road, Westland, MI.

Warehouse Stock Clerk Receiving, checking in and stocking incoming materials and merchandise.

6/80-9/80 Cook Nuclear Plant, Bridgeman, MI.

Quality Control Inspector QC, Supervisor & Jr. Engineer in pipe hangers and systems, and anchor bolt testing.-

10/78-9/79 Insulation Consultant & Hanagement Services, Baroda, MI.

Quality Control Inspector Checked in new materials and checked fire penetration seals for proper installation.

1/78-8/78 Leco Corporation, St. Joseph, MI.

Electrical Technician in Research & Development Built prototype units and tested them against print specifications.

l l

f l

l l

L_

Attcchment to ALAB-106 Qusrterly Raport e

Quality Personnel Resume Organization:

Bechtel Quality Control Name: HINES.

Brian

~(last)

(first)

(I)

Date:

3/26/81 Education:

Redford Union High School, Detroit, MI. (College Prep)

May 1977 Lake Superior State College, Sault Ste. Marie, MI.

(B.S./ Industrial Education Tech.)

Aug. 1972 Henry Fords Community College, Detroit, MI.

(Trigonometry /3 credits with "B" in class)

Work History:

3/81-Present Bechtel Power Corp., Midland MI.

Quality Control Engineer QCE for installation of electric cables. Certify trainee in installation of conduit, boxes, supports, anchor bolts, cable terminations.

9/80-12/80 Rummel Builders, Sebewaing, MI.

Carpenter Performing residential construction, remodeling, additions, and cabinet making.

10/77-5/80 Unionville-Sebewaing Area Schools, Sebewaing, MI.

Industrial Education Teacher (Shop)

Taught class:

1. Welding (arc & gas, and metal fabrication);
2. Building Trades (basic residential construction);
3. Woodworking I & II (basic & cabinet making)
4. Drafting I (basic drafting)
5. Small Engines 9/77-10/77 Dow Chemical (Ziploc), Bay City, MI.

Technician Trainee Ziploc bag manufacturing work on ziploc bag assembly line, machine repair and quality of bags.

1/77-9/77 Sebewaing Light & Water Dept., Sebewaing, M1.

Apprentice Lineman Run power lines, electric services into homes, etc., and general lineman duties. Repair of electrical appliances.

Maintenance and repair of village water systems w

Attachment to ALAB-106 Quarterly Report O

Quality Personnel Resume Organization: Bechtel Quality Control

~Name: HOWARD, James (last)

(first)

(I)

Date:

6/10/81 Education:

June 1972 St. Bernards High School, Montville, CT.

a Work History:

1/80-8/80 Hartford Steamship Boiler Insurance & Inspection. Essex, CT.

Structural Steel Inspector To assure adherance to all codes pertaining to particular jobs.

12/78-11/79 The Boeing Co., Knob Noster, MO.

AWS Certified Weld Inspector To assure adherance to mil-standards in over-haul of missle silos.

10/72-10/78 Electroc Boat / General Dynamics, Groton, CT.

Welder / Welder Supervisor To maintain x-ray quality of welded hull sections of 25 man crew.

l'

Attrchment to ALAB-106 Quarterly R2 port

.o Quality Personnel Resume Organization: Bechtel Quality Control Name: KALE, Mohan (last)

(first)

(1)

Date:

5/12/81 Education:

6/67 St. Cabriels High School, Kazipet, India (Physical Sciences, English, Mathematics) 8/72 Maulana Azad College of Technology, Bhopal, India (Civil Engineering - E.S.C.E.)

Work History:

2/79-10/80 Buckau Wo.1 Engineering Co., Pimpri Poona, India Site Engineer Supervision of fabrication / erection of steel structures, drainage systems, roads, heavy machine foundations, cost analysis, quality control.

9/76-1/79 2AES Consulting Engineers, Mehr Shah Street #16, Tehran, Iran Road Resident Site Engineer Supervision of 30 mile lot of paved highway construction as per specifications, prepare / issue cross drainage work drawings, quantity take off, certify reports, bills with emphasis on quality control.

9/72-7/76 Centra 1 Designs Organization, Opposite Council Hall, Poona, India Jr. Design Engineer Design calculations of a section of hyuro-electric project, including cost analysis, techni:al drafting.

I r

{

l l

l i

v

Attachment to ALAB-106 Quartsrly Rsport Quality Personnel Resume Organization:

Bechtel Quality Control Name: KING.

Ted (last)

(first)

(I)

Date:

5/8/81 Education:

Jackson High School, Jackson, MI.

(College Prep.)

1952 (Night)

Toledo University, Toledo, OH. (Civil Engineer /No degree) 1958 (Night)

Jackson Community College, Jackson, MI. (Economics & Business Law /No degree)

-Work history:

10/77-6/80 Oxy Metal Industries Corp., 21441 Hoover Rd., Warren, MI.

Materials Coordinator Source inspection and expediting of equipment and materials for prcduction of metal finishing equipment.

9/75-4/76 Ralph M. Parson Co., 100 W. Walnut, Pasadena, CA.

Inspector / Expediter Source inspection and expediting of equipment and materials for oil, chemical process and electrical power projects.

2/74-8/75 Bechtel Corporation, 50 Beale St., San Francisco, CA.

Field Expediter Source expediting.

3/73-11/73 Northrup Expediting & Inspection Co., Brooklyn, MI.

Inspector / Expediter Resident inspector / expediter at SS foundry for nuclear valve bodies.

4/71-3/73 General Accessory Products Co., Williamston, MI.

Salesman Sold bicycles and accessories to retail outlets.

7/66-3/71 Commonwealth Associates, Inc., Jackson, MI.

Inspector / Expediter Source inspection and expediting of materials and equipment for electric power generation and transmission projects.

.