ML20005A218
| ML20005A218 | |
| Person / Time | |
|---|---|
| Site: | Point Beach |
| Issue date: | 06/17/1981 |
| From: | Clark R Office of Nuclear Reactor Regulation |
| To: | Burstein S WISCONSIN ELECTRIC POWER CO. |
| Shared Package | |
| ML20005A219 | List: |
| References | |
| TASK-2.K.1, TASK-TM IEB-79-06A, IEB-79-6A, NUDOCS 8106300055 | |
| Download: ML20005A218 (2) | |
Text
'
- erp
,, Y k
'." !T Er' !? ATGS i 'im.-u8 e NUCLEAR R GULATORY COMMISSION
%.'EN ~
k W ASHINGTON. D. C. 20555
[
JUN 171981 e
sn Docket Nos. 50-266 4
and 50-301 4
C' E
- d. 6 1 JW 2 2 M *
-8 Mr. Sol Burstein 2
Executive Vice President u.s. g *j7## [/
if Wisconsin Electric Power Company 231 West Michigan Street p
N Milwaukee, Wisconsin 53201 g
=
Dear Mr. Burstein:
We have completed a review of the information you have provided in letters dated April 19, April 27, August 23, September 20, and September 26, 1979 in response to IE Bulletins 79-06A, and 79-06A Revision 1 for the Point Beach Nuclear Plant, Units 1 and 2.
The enclosed Safety Evaluation addresses the completeness and acceptability of the responses.
Your responses to IE Bulletin 79-06C, regarding the operation of the reactor coolant pumps following a loss-of-coolant accident will be reviewed separately as part of Task Action Plan Item
..K.3.#,
The issuance of this evaluation completes Item II.K.1, IE Bulletins, for your facility.
Sincerely, l y ).k C"
Robert A. Clark, Chief Operating Reactors Branch #3 Division of Licensing
Enclosure:
Safety Evaluation cc w/ enclosure:
See next page O
8106s000g'S
9, Wisconsin Electric Power Compan/
CC:
Mr. Bruce Churchill, Esquire Mr. William Guldemond Shaw, Pittman, Potts and Trowbridge USNRC Resident Inspectors Office 1800 M Street, N. W.
6612 Nuclear Road Wcshington, D. C.
20036 Two Rivers, Wisconsin 54241 Joseph Mann Library 1516 Sixteenth Street Two Rivers, Wisconsin 54241 Mr. Glenn A. Reed, Manager Nuclear Operations Wisconsin Electric Power Coapany Point Beach Nuclear Plant 6610 Nuclear Road Two Rivers, Wi'sconsin 54241
' Mr. Gordon Blaha Town Chairman Town of Two Creeks Route 3 Two Rivers, Wisconsin 54241 Ms. Kathleen M. Falk General Counsel Wisconsin's Environmental Decade 302 E. Washington Avenue Madison, Wisconsin 53703 Director, Criteria and Standards Division Office of Radiation Programs (ANR-460)
U.S. Envi ronmental Protection Agency Washington, D. C.
20460 U. S. Environmental Protection Agency Federal Activities Branch Region V Office
~
ATTN: EIS C00RL dATOR 230 S. Dearborn Street Chicago, Illinois 60604 Chairman Public Service Commission of Wisconsin i
Hills Farms State Office Building Madison, Wisconsin 53702
_