e m

y#

UNITED STATES

%,'i

[*

NUCt. EAR REGULATORY COMMISSION REGloN IV g

k^b, N 'f

$11 RYAN PLAZA DRIVE. SulTE *0C0 ARUNGToN, TEXAS 76011

!/.*J 0 4 g,

MEMORANDUM FOR: Those Listed Below FROM:

G. L. Madsen, Chief, Reactor Projects Branch, RIV

SUBJECT:

IE INFORMATION NOTICE NO. 81-04 Subject IE Infomation Notice has been sent to the following licensees. A copy is attached for your infomation.

Arkansas Power & Light Company ANO-1 & 2 (50-313, 50-368)

Nebraska Public Power District Cooper Nuclear Station (50-298)

Omaha Public Power nistrict Ft. Calhoun Nucl u r Station (50-285)

Public Service Company of Colorado Fort St. Vrain (50-267)

&lfifgh & '

'G. L. 4.adsen, Chief Reactor Projects Branch

Attachment:

As stated DISTRIBUTION:

IE FILES MPA/DTS CENTRAL FILES

\\ P f r6N

<rri A

S gg,1-<

.K G

?

MJ g g

R P P. 0 3 1g g g n =

E k T. w,a

-r... i4,1:

3.

8106220 msg R

SSINS No.: 6835 Accession No.:

8011040265 UNITED STATES NUCLEAR REGULATORY CCMMISSION OFFICE OF INSPECTION AND ENFORCEMENT

'4ASHINGTON, D.C. 20555 IE Information Noticc 'lo. 31-04 February 27, 1981 Page 1 of 2 CRACKING IN MAIN STEAM LINES Descriotion of Circumstances:

The Virginia Electric Power Company promotly notified the NRC on Feoruary 23, 1981 that a radiography examination, during the ongoing steam generator replacement outage at Surry Unit 1, had revealed a lengthy crack indication in tne I.O. countercore area of a welcment on the in-line "T" fitting which connects the vertical run of 30-inch piping to the safety relief valve header and 30-inch main steam line of Steam Generator "A."

This piping ccnnection is located outside the containment penetration f aneciately uostream of the main steam isolation valve as shown in the attached sketch.

A visual and dye penetrant examination on the pipe I.D. surface of the weldment nearest the containment penetration established that the cracking extended about 120 F around the fitting counterbore between the 4 o' clock to 3 o' clock position.

Cracking was also observed in the weld countercore at the opposite end of the T-fitting during visual examination of the piping interior.

Radio-

. wmc examination of "3" and "C" main steam line T-fitting welds disclosed crack indications at similar locations.

Metallurgical specimens of the cracking were trepanned from the T-fitting of the "A" main steam line for analysis.

Controllec excavation and deptn measurements of the crack at its mid-length indicated a crack depta of about 0.090" in this location.

The cause of cracking has not yet been established.

VEPCO has planned an ultrasonic examination of similar welcments in surry Unit 2 main steam lines utilizing " Hot Piping" ultrasonic tecnnicues.

Precarations are also being mace to ultrasonic examine similar welcments at North Anna Unit 1, currently in cold snutcown for refueling.

Recommencation to Licensees:

$de 44mtion is crovided as an early notification of a significant safety g? 5 t 9/ 7 m : '

7;,

or possible acclicacility to Oneir

~

- NRC staff.

It is exoected tnat m

.-x gf',

main steam line configurations wnica h

DUPLICATE DOCUMENT t recair outage, it is rec:mmenced I'

amination of :ne tnree welcs anc f"

Entire document previously

erformec aefore rescotion of p

entered into system under:

3r assurance of oicing integrity 30ll N o Q 7 ANo No. of paces:

//

tik TshWhLiQ 7,[

,