ML20004F608

From kanterella
Jump to navigation Jump to search
Responds to NRC 810526 Ltr Re Violations Noted in IE Insp Repts 50-508/81-07 & 50-509/81-07.Corrective Actions Re Unqualified Welds Under Investigation
ML20004F608
Person / Time
Site: Satsop
Issue date: 05/29/1981
From: Leddick R
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To: Faulkenberry
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20004F607 List:
References
GO3-81-2057, NUDOCS 8106190199
Download: ML20004F608 (2)


Text

.~>J-Washington Public Power Supply System eox 1223 Elma. Washington 98541 (206)482 4428

~

May 29, 1981 G03-31-2057 4

~) '

ny Nuclear Regulatory Commission, Region V JUn' 2 ;C31 :

Suite 202, Walnut Creek Plaza c'.c1 v -

1990 North California Boulevard \

Walnut Creek, California 94596

$Ec M ^' -

s Attention: Mr. b. H. Faulkenberry Chief, Reactor Construction Projects Branch Gentlemen:

Subject:

PROJECT NOS. 3 AND 5 NRC INSPECTION OF WNP-3 AND WNP-5 DOCKET NUMBERS 50-508 AND 50-509

Reference:

Letter, G03-81-2046, R. S. Leddick t.o B. H. Faulkenberry, same subject, dated May 26, 1981.

The reference letter transmitced the Supply System's response to a Notice of Violation containec in your letter dated April 29, 1981.

We would like to take this opportunity to correct information supplied to you in our letter of May 26, 1981. In this letter we stated in the " Corrective Steps Which Have Been laken To Avoid Further Violation", Item 2, that between April l'and April 21, 1981 no unqualified welds were performed. Contrary to this, unqualified welds were performed during this period on supports released to the field for installation. This matter is presently ur. der investigation. Upon completion of this investigation the _

subject unqualified welds will be ider.tified and reported on an NCR, as per Item 4 of " Corrective Steps Which Have Been Taken."

All other statements in our response are correct as stated.

Every effort is made to respond to NRC letters and questions factually.

We sincerely regret this error and we shall increase our efforts to ensure accuracy of future responses. We hope this exaplanation will 1 sa*.isfactorily answer any questions which may have occt.rred.

Vergtrulyyours, R. S. Leddick Program Director, WNP-3/5 cc: D. Smithpeter - BPA Ebasco - New York WNP-3/5 Files - Richland t

. 8106190 M ,

C/-/5 e

m.. ,

R. S. LEDDICK, Being first duly sworn, deposes and says: That he is the Program Director, WNP-3/5, for the WASHINGTON PUBLIC POWER SUPPLY SYSTEM, the applicant herein; that he is authorized to submit the fore-going on behalf of said applicant; that he has read the foregoing and-knows the contents thereof; and believes the same to be true to the

-best of his knowledge.

DATED '77l %u cR7 i

, 1981.

i t s r

R. S. LEDDICK STATE OF WASHINGTON . ._ ) . _ _ . _ _ _ _ _. _ _

) ss ,

COUNTY OF GRAYS HARBOR )

On this day personally appeared before me R. S. LEDDICK to me known to be the individual who executed the foregoing instrument and acknowledged that he signed the same as his free act an,( deed for the uses and pur-poses therein mentioned. 11.

/)>

GIVEN under my hand and seal this c29 day of , 1981.

,\d c n :

f\ pj[f w'\fS,' . "

b) b y Notary Public in and'for the Stpte I

of Washington Residing at A b4ch 1

I l

l

._ -. _ _ - ... _ _ - -